LNC LVRFUQJ507288C 3 Light Polished Gold and Crystal Beaded Strand Instruction Manual

June 15, 2024
LNC

LNC LVRFUQJ507288C 3 Light Polished Gold and Crystal Beaded Strand

LNC-LVRFUQJ507288C- 3-Light-Polished-Gold-and-Crystal-Beaded-
Strand

Product Information

Specifications

  • Item Number : A05072
  • Voltage : 120V
  • Maximum Wattage : Type B, Max 40W per bulb
  • Weight : Not specified

Product Usage Instructions

Step 1: Preparation

Before starting assembly and installation, make sure you have the following tools:

  • Ladder
  • Philips Head or Flat Blade Screwdriver
  • Electrical Tape
  • Pliers
  • Wire Cutter/Stripper

Step 2: Assembly & Installation

  1. Carefully remove the fixture from the carton and check that all parts and accessories are included.
  2. Using chain pliers, disconnect and discard any unwanted parts of the main chain (I).
  3. Gently pull the wires to ensure they are not stressed.
  4. Make sure the mounting surface is clean, dry, flat, strong enough, and 1/4 larger than the canopy on all sides. Correct any gaps exceeding 3/16 as required.
  5. Ensure that the ceiling or wall can support the weight of the lamp before installation.
  6. Unscrew the collar ring (F) from the collar loop (G) and remove the canopy (E).
  7. The side of the single bar (C) marked GND must face out.
  8. Screw the collar loop (G) onto the single bar (C) until the secure length is achieved (no less than 6 threads on the pre-assembled threaded nipple).
  9. Pass the fixture wires through the collar loop (G) to the top of the pre-assembled threaded nipple and gently pull to ensure they are not stressed.
  10. Attach the canopy (E) snugly against the ceiling, ensuring that the collar loop (G) is securely screwed onto the threaded nipple.
  11. Secure the lamp to the mounting surface using the provided mounting screws (B).

FAQ

Q: What should I do before starting any work on the lamp?

A: Before you start, NEVER attempt any work without shutting off the electricity until the work is done.

Q: Can I replace the bulbs while the lamp is still on?

A: No, when replacing bulbs, you should turn off or unplug the lamp and wait until it is cool as bulbs get hot quickly.

Q: Are there any restrictions on the type and wattage of bulbs I can use?

A: Yes, make sure you are using Type B bulbs with a maximum wattage of 40W per bulb.

WARNING

(To reduce the risk of fire, electric shock, or personal injury):

  1. We suggest installation by a licensed electrician.
  2. Please read the instructions carefully and save it as you may need it at a later time.
  3. Before you start, NEVER attempt any work without shutting off the electricity until the work is done.
  4. Go to the main fuse, or circuit breaker, box in your home. Place the main power switch in the “OFF” position.
  5. Place the wall switch in the “OFF” position.
  6. The mounting surface should be clean, dry, flat, strong enough, and 1/4” larger than the canopy on all sides. Any gaps between the mounting surface and canopy exceeding 3/16” should be corrected as required
  7. Make sure that the ceiling or wall can stand the weight of the lamp before installation.
  8.  Make sure the voltage you are using is 120V. The maximum wattage is Type B, with a max of 40W per bulb.
  9. Keep the lamp away from acidic and alkaline substances in case of damaging the surface of the lamp.
  10. When replacing bulbs, you should turn off or unplug the lamp and you must wait until it is cool as bulbs get hot quickly.
  11. The safety instructions appearing in this manual are not meant to cover all possible conditions that may occur. It must be understood that common sense, caution, and care must be used with any electrical products.

IMAGE FOR FINISHED PRODUCT:

LNC-LVRFUQJ507288C- 3-Light-Polished-Gold-and-Crystal-Beaded-Strand -
fig1

TOOLS REQUIRED (NOT INCLUDED):

LNC-LVRFUQJ507288C- 3-Light-Polished-Gold-and-Crystal-Beaded-Strand -
fig2

Before starting assembly and installation please prepare the needed tools as below picture

PARTS

TYPE & QTY INCLUDING:

LNC-LVRFUQJ507288C- 3-Light-Polished-Gold-and-Crystal-Beaded-Strand -
fig3

  • (C) Single bar (1)
  • (D) Green ground screw (1)
  • (E) Canopy (1)
  • (F) Collar ring (1)
  • (G) Collar loop (1)
  • (H) Quick link (2)
  • (I) Main chain (1)
  • (J) Loop (1)
  • (K) Frame (1)
  • (L) Crystal string (24)
  • (M) Pipe (1)
  • (N) Socket assembly (1)

ACCESSORIES & QTY

ACCESSORIES & QTY ENCLOSED:

  • (A) Wire connector (3)
  • (B) Mounting screw (2)
  • Crystal hook (2) (spare part)

INSTALLATION INSTRUCTIONS

ASSEMBLY & INSTALLATION INSTRUCTIONS:

  1. Carefully remove the fixture from the carton and check that all parts and accessories are included as shown in the above illustration.
  2. Make pre-installation

LNC-LVRFUQJ507288C- 3-Light-Polished-Gold-and-Crystal-Beaded-Strand -
fig4

Step A1 : Screw pipe (M) onto top of socket assembly (N)

Step A2 : Screw loop (J) to the top of the pipe (M) through the frame (K) as shown in the illustration.

LNC-LVRFUQJ507288C- 3-Light-Polished-Gold-and-Crystal-Beaded-Strand -
fig4 LNC-LVRFUQJ507288C-
3-Light-Polished-Gold-and-Crystal-Beaded-Strand - fig8

Step B1: By measuring, determine the correct number of links needed for proper hanging height. Using the chain pliers, disconnect and discard the unwanted parts.
Step B2: Attach quick links (H) to the main chain (I) and loop (J) on the top of the frame (K).
Step B3 : Carefully weave the fixture wires through the main chain (I) in and out of every other link and stop just when you reach the top of the main chain (I). Gently pull the wires to ensure the wires are not stressed.

Turn off power
Before you start the installation, NEVER attempt any work without shutting off the electricity until the work is done.

  • * Go to the main fuse, or circuit breaker, box in your home. Place the main power switch in the “OFF” position.
    • Place the wall switch in the “OFF” position.

Make installation

LNC-LVRFUQJ507288C- 3-Light-Polished-Gold-and-Crystal-Beaded-Strand -
fig5

  • Step C1: Remove collar ring (F) from collar loop (G). Attach single bar (C) to the outlet box with mounting screws (B).
    • NOTE: the side of the single bar (C) marked “GND” must face out.
  • Step C2: Raise canopy (E) over collar loop (G) and screw collar ring (F) to measure a proper position. Unscrew collar ring (F) from collar loop (G) and remove canopy (E). Refer to the following note, you would know the proper position where collar loop (G) should be located.
    • NOTE: canopy (E) should be snug against the ceiling and collar loop (G) should be screwed with enough threads (no less than 6 threads) on the pre-assembled threaded nipple for more secure hanging.
    • If not, adjust the collar loop (G) on the single bar (C) by screwing the collar loop (G) in or out of the single bar (C) until the secure length is achieved.
  • Step C3: Pass the main chain (I) through the collar ring (F) and then through the canopy (E).
  • Step C4: Open quick link (H), and attach quick link (H) to collar loop (G). Close quick link (H). Pass the fixture wires through the collar loop (G) to the top of the pre-assembled threaded nipple and gently pull to ensure the wires are not stressed.
  • Step C5: If needed, shorten the length of the fixture wires. At this point, the remaining wire length measured above the single bar (C) is at least 6″.
    • Twist wires together with plastic wire connectors (A) until tightly joined.
    • Wrap each connector with approved electrical tape.
    • Be sure that no wire strands are exposed and then carefully tuck all wires into the outlet box.
  • Step C6: Make wire connections

Connect wires as below wires connection shown.

PLEASE NOTE THAT GROUND WIRE IS BARE

Connect ground wires according to the chart below

Connect wires according to the below chart

LNC-LVRFUQJ507288C- 3-Light-Polished-Gold-and-Crystal-Beaded-Strand -
fig9

  • Note: When parallel wires (SPT I& SPT ll) are used. The neutral wire is square shaped or ridged and the other wire will be round in shape or smooth (see illus.)

COPPER WIRE, NEVER CONNECT OTHER WIRES TO GROUND WIRES.

  • Twist wires together with plastic wire connectors (A) until tightly joined.
  • Wrap each connector with approved electrical tape.
  • Be sure that no wire strands are exposed and then carefully tuck all wires into the outlet box.
  • Step C7: Raise canopy (E) to the ceiling and secure canopy (E) in place by tightening collar ring (F) onto collar loop (G).
  • Step C8: Install bulbs (not included) (Please do not exceed the maximum wattage recommended on the socket.)

Check everything is already installed properly, and then you can turn on the light. Enjoy!

ORDERING PARTS
Keep this sheet for future reference in case you need to order replacement parts. All parts for this fixture can be ordered from the place of purchase. Be sure to use exact wording from illustrations when ordering parts.

CLEANING
To clean, wipe the fixture with a soft cloth. Clean glass with a mild cleaner (such as mild and non-abrasive soap). Do not use abrasive materials such as scouring pads or powders, steel wool or abrasive paper.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

LNC User Manuals

Related Manuals