CREATE Humizen Pro Ultrasonic Humidifier and Aroma Diffuser User Manual
- June 15, 2024
- CREATE
Table of Contents
CREATE Humizen Pro Ultrasonic Humidifier and Aroma Diffuser
Product Information
Specifications
- Product Name: HUMIZEN PRO
- Type: Humidifier
- Working Principle: Ultrasonic high-frequency oscillator
- Water Particle Diameter: 1-5 um
- Relative Humidity Range: 40-65% RH
Working Principle
The HUMIZEN PRO humidifier uses an ultrasonic high-frequency oscillator to
break up water into tiny water particles with a diameter of about 1-5 um. The
ventilation system blows out these water particles into the dry air, where
they evaporate to provide the required humidity. The result is a smooth and
even fog that is clearly visible.
Characteristics
The HUMIZEN PRO humidifier offers the following characteristics:
- Ultrasonic technology for efficient and quiet operation
- Adjustable mist volume control
- Integrated water filter for clean and purified mist
- Aroma box for adding fragrance to the mist
- User-friendly display and control panel for easy operation
- Remote control for convenient access
Relative Humidity
The relative humidity (RH) refers to the percentage of water mist in a
given space with a given air temperature. The HUMIZEN PRO humidifier helps to
increase the mist volume in the air, thus maintaining a healthy environmental
humidity. Recommended relative humidity levels for different environments are
as follows:
- Bedroom, living room: 45-65% RH
- Patient’s room: 40-55% RH
- Room with computer, experiment equipment: 45-60% RH
- Room with a piano: 40-60% RH
- Museum, exhibition hall, and library: 40-50% RH
Water Filter
The HUMIZEN PRO humidifier is equipped with an integrated water filter that
helps to purify the mist by removing impurities and ensuring clean and healthy
humidification.
Aroma Box
The HUMIZEN PRO humidifier features an aroma box where you can add your
favorite fragrance or essential oils. The mist will carry the aroma and create
a pleasant atmosphere in the room.
Parts List
The HUMIZEN PRO humidifier comes with the following parts:
- Main unit
- Water tank
- Water filter
- Aroma box
- Display
- Control panel
- Remote control
Display and Control Panel
The HUMIZEN PRO humidifier is equipped with a user-friendly display and
control panel for easy operation. The display shows the current settings and
the control panel allows you to adjust the mist volume, set a timer, and
control other functions.
Operation Instructions
To operate the HUMIZEN PRO humidifier, follow these steps:
- Place the humidifier on a flat and stable surface.
- Remove the water tank and fill it with clean and cold water.
- Insert the water filter into the designated slot in the water tank.
- Place the filled water tank back into the main unit.
- Connect the humidifier to a power source using the provided power cord.
- Press the power button on the control panel or remote control to turn on the humidifier.
- Adjust the mist volume and other settings according to your preferences using the control panel or remote control.
- The humidifier will start producing a fine mist, increasing the humidity in the room.
Remote Control
The HUMIZEN PRO humidifier comes with a remote control for convenient
access to all functions and settings. Use the remote control to adjust the
mist volume, set a timer, control the aroma box, and more.
Replacing the Remote Control Battery
If the remote control battery is running low, follow these steps to replace
it:
- Locate the battery compartment on the back of the remote control.
- Slide open the battery compartment cover.
- Remove the old battery and dispose of it properly.
- Insert a new battery into the battery compartment, ensuring correct polarity.
- Close the battery compartment cover.
Troubleshooting
If you encounter any issues with the HUMIZEN PRO humidifier, refer to the
troubleshooting section in the user manual for possible solutions. If the
problem persists, contact customer support for further assistance.
Maintenance
To ensure optimal performance and longevity of the HUMIZEN PRO humidifier,
regular maintenance is recommended. Follow these guidelines:
- Regularly clean the water tank and water filter to prevent the buildup of mineral deposits and impurities.
- Use clean and cold water for filling the water tank to avoid contamination.
- Replace the water filter as recommended by the manufacturer.
- Keep the humidifier in a clean and dust-free environment.
FAQ
-
Q: What is the recommended relative humidity for a bedroom?
A: The recommended relative humidity for a bedroom is 45-65% RH. -
Q: Can I add fragrance or essential oils to the HUMIZEN PRO humidifier?
A: Yes, the HUMIZEN PRO humidifier features an aroma box where you can add your favorite fragrance or essential oils to create a pleasant atmosphere in the room. -
Q: How often should I clean the water tank and water filter?
A: It is recommended to clean the water tank and water filter regularly to prevent mineral deposits and impurities. The frequency of cleaning depends on the water quality and usage conditions. Refer to the user manual for detailed instructions. -
Q: How do I replace the water filter?
A: To replace the water filter, follow the instructions provided in the user manual. It is important to use genuine replacement filters recommended by the manufacturer. -
Q: What should I do if the humidifier is not producing mist?
A: If the humidifier is not producing mist, check if the water tank is properly filled and the water filter is clean. Also, ensure that the power is connected and the humidifier is turned on. If the problem persists, refer to the troubleshooting section in the user manual or contact customer support.
Thank you for choosing our humidifier. Before using the appliance, and to
ensure the best use, carefully read these instructions.
The safety precautions enclosed herein reduce the risk of death, injury and
electrical shock when correctly adhered to. Keep the manual in a safe place
for future reference, along with the completed warranty card, purchase receipt
and package. If applicable, pass these instructions on to the next owner of
the appliance. Always follow basic safety precautions and accident-prevention
measures when using an electrical appliance. We assume no liability for
customer failing to comply with these requirements.
SECURITY INSTRUCTIONS
When using any electrical appliance, basic safety precautions should always be observed.
-
Please follow all the safety precautions listed below for safety and to reduce the risk of injury or electrical shock.
-
This humidifier can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the humidifier in a safe way and understand the hazards involved. Children shall not play with the humidifier.
-
Cleaning and user maintenance shall not be made by children without supervision.
-
Before using this humidifier ensure that the voltage of your electricity supply is the same as that indicated on the rating plate of the humidifier.
-
Always place the humidifier on a hard, flat and level surface. Avoid exposure to direct sunlight and always keep it away from walls and heat sources such as stoves, radiators, etc.
-
The humidifier may not work correctly if it is not placed on a level surface.
-
Do not insert or remove the electric plug on the humidifier with wet hands.
-
If the mains cable is damaged it must be replaced by the manufacturer, its service agent, or similarly qualified person in order to avoid a hazard.
-
To reduce the risk of electric shock, do not remove screws. The humidifier does not contain any user-serviceable parts. Please leave all maintenance work to qualified personnel.
-
Fill the tank with fresh, distilled or demineralized water. Do not drop any other liquid into the water tank. Do not run the humidifier when there is no water in the tank.
-
Do not shake the humidifier as this might cause the water spill over into the base of humidifier.
-
Never touch the water or any component while the humidifier is in operation.
If there is an unusual smell when it is being used as described in this manual, switch the humidifier off, unplug it and have it examined by your dealer. -
Do not pour hot water into the tank, i.e. at a temperature over 40°C.
-
Unplug the humidifier before cleaning it or removing the tank.
-
Do not immerse the humidifier or the mains cable or plug in water or other liquids.
-
Never scrape the transducer with a hard tool. The humidifier must be cleaned regularly. To do this, refer to the cleaning instructions in this manual.
-
If you spill any liquid into the humidifier, it can cause serious damage. Switch it off at the mains immediately. Withdraw the mains plug and consult your dealer.
-
Disconnect the humidifier from the power supply when not in use and before cleaning.
-
Ensure that the mains cable does not touch any hot surface and that it does not overhang a table edge.
-
Never use this humidifier in a room where aerosol products (sprays) are used or in a room where oxygen is being administered.
Do not put items of clothing or towels on top of the humidifier. If the nozzle is obstructed, this may cause the humidifier to malfunction. -
When moving the humidifier, lift it by the base and not by the water tank.
-
Do not use the humidifier if the air in the room is already sufficiently humid.
-
The ideal relative humidity level for human comfort is in fact between 45% and 65%. Excess humidity shows up in the form of condensation on cold surfaces or cold walls in the room. To measure the room’s humidity correctly, use a hygrometer available in most specialist shops and hypermarkets.
-
The humidifier is designed for indoor and domestic use only.
CHARACTERISTICS
WORKING PRINCIPLE
The ultrasonic humidifier uses the ultrasonic high-frequency oscillator to
break up water into tiny water particles with the diameter of about 1-5 um.
The ventilation system blows out this water into the dry air where they
evaporate to give the required humidity. The clearly visible smooth and even
fog can be seen out of the humidifier.
RELATIVE HUMIDITY
- The percentage of water mist in a given space with a given air temperature is named as relative humidity, usually marked as % RH, i.e. 45% RH. The air contains water mist more or less. The proportion of water mist to the air varies according to different air temperatures. The higher the temperature, the more water mist inhaled in the air.
- In winter, the cold air outside enters the room and becomes warmer by the higher temperature in the room. As a result, the relative humidity decreases. If you want to keep the healthy environmental humidity, we need to increase the mist volume in the air. The humidifier can do that for us.
- Relative humidity in different environments suitable for people:
- Bedroom, living room: 45-65% RH
- Patient’s room: 40-55% RH
- Room with computer, experiment equipment: 45-60% RH
- Room with a piano: 40-60% RH
- Museum, exhibition hall, and library: 40-50% RH
WATER FILTER
- Ceramic balls can soften the hard water.
- A ceramic filter can eliminate the strange smell in the water.
AROMA BOX
- Press out the aroma box from the base.
- Use water-soluble aroma oil and drop on to the sponge.
- Put the aroma box back into the humidifier, the aroma function will remain on when the humidifier is running.
- To stop the aroma function or when storing the humidifier, clean the sponge in the aroma box.
- Only drop aroma oil into aroma cotton. Do not drop any liquid except clean water into the water tank.
PARTS LIST
- Top cover
- Handle
- Nozzle
- Water tank
- Control panel
- Host
- Sensor
- Power cord
FEATURES
- Highly efficient in humidification with large output.
- Low energy consumption, save 85-90 percent of electricity than normal stream humidifier.
- Long lifetime.
- Automatic control of humidity level, lack-of-water security protection.
- Base with aroma cotton, to wet it with aromatic oil.
OPERATION INSTRUCTIONS
- First operation : Put the humidifier in the room temperature for half an hour before running.
- It is recommended to use the humidifier under a temperature of 20°C, relative humidity less than 80% RH.
- Use clear water not over 40°C.
- Check the water tank, make sure it is clear.
- Put the humidifier on a flat surface.
- Remove the top cover, fill water into the water tank, and then put back the top cover. Or take out the water tank for filling water, afterwards put the water tank back on the main base.
- Check if the rated voltage meets the input voltage, and plug into the socket. Then the display will light up and the buzzer will ring for once. 1 second later, the display turns off, only red symbol POWER showing and the humidifier is in standby state.
- Touch the symbol POWER , display background and water tank indicator light will light up meanwhile. Humidifier will begin to work in AUTO mode, with display showing AUTO symbol and current humidity. 10 seconds later, the display shows current temperature, and then changes into humidity. Temperature and humidity showing will switch once in every minute.
Humidifier will decide running humidity based on current temperature as below table.
Temperature of the air,
degrees Celsius
| ≤19|
20
|
21
|
22
|
23
|
24
|
25
|
26
|
27
|
28
|
29
|
30
|
31
|
32
|
33
|
34
|
35
|
36
|
≥37
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---
Humidity (%)
|
65
|
60
|
58
|
57
|
55
|
53
|
50
|
48
|
45
|
43
|
40
|
38
|
36
|
35
|
34
|
32
|
31
|
30
|
25
-
Constant Humidity: Touch the symbol HUMIDITY , you may select the humidity range from 30% RH to 75%. Touch once, it will increase by 5% RH for each time. When it reaches 75%, touch again, it will show “–” and humidifier will run back to AUTO mode.
-
After setting the expected humidity, humidifier will keep the memory and confirm by flashing in 3 seconds. Once the display switches to show current humidity, it means setting is finished, “%” on display will flash slowly.
- When setting humidity is 1% RH ~ 9% RH higher than current humidity, mist output speed will run by the lowest (the first) speed.
- When setting humidity is 10% RH ~ 15% RH higher than current humidity, mist output speed will run by the middle (the third) speed.
- When setting humidity is 15% RH higher than current humidity, mist output speed will run by the highest (the fifth) speed.
- When current humidity is higher than setting humidity, humidifier will turn into sleep state. Once current humidity is 3% RH lower than setting humidity, humidifier will rework in previous working mode till water shortage.
Mist output speed is adjustable under constant humidity function.
-
Night Mode : Long press symbol HUMIDITY for 2 seconds to shut down water tank indicator light and display, only red ON/OFF symbol is showing. Press any symbol to wake up the light and display.
-
Timer: There are 12 timer setting: 1,2,3,4,5,6,7,8,9,10,11,12 hours. Touch the symbol TIMER , the LED display will show the timer setting from 01-12 in sequence, for example “1H”. Once finished setting excepted timer, without operation for 3 seconds, the timer stop flashing means that the timer setting is successful.
- The timer shows the rest operation time every minute and decreases by 1 hour, i.e., if the timer is set at 12 hours, LED display shows 11 after 1 hour.
- There is a shortcut for timer setting. Long press the symbol TIMER 2 seconds to cancel timer setting.
-
Disinfect: Symbol DISINFECT , first touch to start heating function, display shows symbol HEATING . Warm mist will come out after 10~15 minutes. Second touch to start plasma function, display shows symbol PLASMA , plasma generator works as well. Third touch to shut down heating function. Fourth touch to shut down plasma function.
-
Long press symbol DISINFECT to turn on/off water tank indicator light.
-
Mist Output Speed: Touch to enter manual mode, sliding from MIN to MAX to select desired mist output speed. Sliding from left to right, speed will increase from 1 to 5, with display showing from 1 to 5 accordingly.
-
Auto Shut-Off: Once the water in the tank is not enough to keep the humidifier continue working, the humidifier will automatically stop working and will warn with 3 beeps (no sound under NIGHT mode). Display will show water shortage symbol only. Refill water tank, humidifier will restart after 5 seconds. Otherwise, humidifier will automatically power off after 5 minutes.
REMOTE CONTROL
When first using the remote control, the plastic tab should be removed from the battery compartment.
- On / Off
- Speed
- Humidity
- Timer
- Plasma
- Auto
REPLACING THE REMOTE CONTROL BATTERY
- Remove the battery compartment by pinching the tab and pulling the compartment out as below picture.
- Remove the old battery.
- Replace with a new battery. Make sure that the polarities match.
- Replace the battery compartment.
TROUBLESHOOTING
PROBLEM | POSSIBLE CAUSE | SUGGESTED SOLUTION |
---|---|---|
Power lamp is off when switched on. | Humidifier is not plugged in. | Plug the |
humidifier into a powered electrical socket.
Power cord is damaged.| Immediately stop using and contact Customer Support.
Humidifier is defective or malfunctioning.
Power lamp is on when switched on, but no mist comes out.| Humidifier is not
turned on.| Press the power button to turn it on.
The target humidity is reached.| Increase the target humidity or change mode.
Water shortage indicator is on.| No water in the tank.| Refill the water tank
and wait at least 1 minute.
Water level is low.
The water level required has not yet reached the vaporization compartment.|
Wait at least 1 minute.
The water tank isn’t well positioned.| Check the positioning of tank on the
base.
The humidifier isn’t on a flat surface.| Check the positioning of the
humidifier.
Humidifier produces an unusual smell.| Humidifier is new.| Take out water
tank, open cover, let it stay 12 hours in cool position.
Dirty water or water sitting too long.| Clean water tank, fill with clear
water.
Residual smell from diffusing aroma oil on the aroma cotton.| Remove the aroma
cotton, rinse it under clean water and allow it to dry.
Humidifier makes a loud or unusual sound.| Resonant in water tank when water
is too low.| Fill water into water tank.
Humidifier is on an unstable surface.| Move the humidifier to a stable flat
surface.
Water tank is positioned incorrectly.| Turn off and unplug the humidifier,
then align the water tank cover with its respective opening in the inner
chamber.
Humidifier is malfunctioning.| Immediately stop using and contact Customer
Support.
The humidification capacity is too low.| There is natural or artificial air
replacement in the room which interfere the increase of %RH.| Check if doors
and windows are closed.
Check if there is no air conditioning working in the room.
The air inlet grids and nozzle could be blocked.| Remove any blocking items
from the
grids and the nozzle.
Too much scale in the water tank.| Clean transducer.
The humidity selected rate is too low.| Increase mist output speed.
Increase humidity setting rate.
Water is too dirty or water kept too long in the tank.| Clean water tank,
change to fresh clear water.
PROBLEM| POSSIBLE CAUSE| SUGGESTED SOLUTION
---|---|---
The ambient humidity is too high.| Humidifier is working in CONTINUOUS MODE.|
Change the mode.
The humidity target is too high.| Select a lower %RH target.
Room is not well-ventilated.| Open a window to ensure proper air flow for your
humidifier, or move the humidifier to a more well-ventilated room.
Excess water tank has spilled while filling the water tank or replacing the
water tank back onto the base.| Wipe off excess water from the top and bottom
of the base before replacing the water tank.
There is condensation in the room.| The room temperature is too low.| Heat the
room up.
The mist suddenly stops coming out.
| Programmed timer period has run out.| Turn humidifier on.
The water shortage indicator is on.| Refill water tank.
The target humidity level is reached.|
Incorrect humidity level is being displayed.| Room is larger than the
effective range of the humidifier.| Move the humidifier to a room which is
with suitable room size.
Moisture has built up inside of the humidity sensor.| Turn off the humidifier
and allow the humidity sensor to completely air dry before resuming use.
The nozzle is facing the direction of the humidity sensor.| Turn the nozzle so
that it is facing away from the humidity sensor.
Humidity sensor is broken or defective.| Contact Customer Support.
Control panel does not work.
| Hands are too wet when operating control panel.| Keep hands dry while
operating the control panel.
Humidifier has malfunctioned.| Contact Customer Support.
White dust appears around the humidifier.| Water being used has a high mineral
content.| Use distilled water with the humidifier. If distilled water is not
available, use purified or filtered water. Remember to clean water tank at
least once a week.
Humidifier was not properly cleaned after last use.| Clean humidifier.
Mist is coming out from the base.| Water tank is not positioned correctly.|
Turn off and unplug the humidifier, then align the water tank cover with its
respective opening in the inner chamber.
Mist fog coming out from around the nozzle.| There are apertures between the
nozzle and water tank.| Reposition the cover and check if the nozzle is well
plugged in the cover.
The warm mist function does not produce warm mist.| The humidifier is in
warmup phase.| Wait a few minutes till the end of the phase.
The mist is too fine to feel the warmth.| Increase the speed level.
The room temperature is too cold and the mist may cool down too quickly.|
Increase the speed level and heat the room up.
PROBLEM| POSSIBLE CAUSE| SUGGESTED SOLUTION
---|---|---
Remote control does not work.| Remote control is out of range from the
humidifier.| Use the remote control within 5 m of the humidifier.
The plastic tab blocks the battery.| Remove the plastic tab from the battery
compartment.
Battery needs to be changed.| Replace the battery.
The following is not considered faulty operation:
- If your water is very hard (containing abnormally high levels of minerals) the humidifier may produce white dust. This is not a malfunction. The solution would be to clean the filter more often or use softer water.
- If you stand very close to the humidifier, you will hear the gurgling sound of water. This is normal.
- The humidifier operates very quietly but it is not completely silent. Noise levels less than 35 dB (A) is considered normal.
MAINTENANCE
- In case the water is hard, which means water contains too much calcium and magnesium, it can cause a “white powder” problem and leave heavy scales on the surface of the water tank, transducer and inner surface of the water tank. Scales on the surface of transducer will let the humidifier work improperly.
- We recommend:
- Use cold boiled water or distilled water.
- Clean the transducer, water tank and basin humidifier every week.
- Change the water in water tank more often to keep it fresh.
- Make sure to pour out water from the water tank and dry the water tank before you store it unused for a long time.
- Clean the whole humidifier and make sure that all parts of the humidifier are dried completely if it is supposed to be left unused for a long time.
- How to clean the transducer:
- Clean with clean water or citric acid if there is scale in it.
- Brush off the scale from the surface.
- Rinse the transducer with clean water.
- How to clean the water tank:
- Clean the water tank with a soft cloth or use citric acid if there is scale in it.
- If the scale is covering the security switch, drop citric acid for 2-5 min on the scale and clean it out with a brush.
- Rinse the water tank with clean water.
- How to clean ceramic filter:
- Clean and activate the ceramic ball filter after using 1000L water regularly. Depending on water quality. If the ceramic ball is dirty, it needs to be cleaned more frequently.
- It can be dipped in vinegar about 5 minutes. Then rinse it cleanly with clean water.
- Then put the filter under the sun for 4~6 hours.
In compliance with Directives: 2012/19/EU and 2015/863/EU on the restriction of the use of dangerous substances in electric and electronic equipment as well as their waste disposal. The symbol with the crossed dustbin shown on the package indicates that the product at the end of its service life shall be collected as separate waste. Therefore, any products that have reached the end of their useful life must be given to waste disposal centres specializing in separate collection of waste electrical and electronic equipment, or given back to the retailer at the time of purchasing new similar equipment, on a one for one basis. The adequate separate collection for the subsequent start-up of the equipment sent to be recycled, treated and disposed of in an environmentally compatible way contributes to preventing possible negative effects on the environment and health and optimizes the recycling and reuse of components making up the apparatus. Abusive disposal of the product by the user involves application of the administrative sanctions according to the laws.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>