Ai POWER SUA7000L 7000 Watt Portable Generator User Guide
- June 12, 2024
- Ai POWER
Table of Contents
SUA7000L
Generator Quick Start Guide
SUA7000L 7000 Watt Portable Generator
Unpack Generator: Remove generator, accessories, inserts and Literature from carton. If any item is missing or damaged, contact our product service department at 1-855-888-3598.
WARNING This Quick Reference Guide is not substitute for reading the operator’s manual. To reduce the risk of injury or death, user must read and underdstand the operator’s manual before using this product. All pages references to the operator’s manual.
- Install the wheel kit
Slide the axle pin(A) through the wheel(B), flat washer(C) and mount point on the frame(D). Secure them with cotter pin(E).
Attach the support leg(G) to the
generator frame with flange bolt(F)(M8X16) and flange lock nut(H)(M8).
Install the handle(I) to the frame with bolts(J) (M8X20) .
-
Add Lubricant and Fuel
Use a funnel to pour provided engine oil into engine. Fill to the upper mark of the oil dipstick H.Use clean / fresh regular UNLEADED gasoline with a minimum 87 octane. -
Adjust Shock-absorbing Seat
Before operating the generator the shock-absorbing seat (cushion) must be adjusted for proper clearance. Loosen the lock nut and adjust the shock- absorbing seat so there is a 3mm gap between the top of the seat and the bottom of the motor bracket. Re-tighten the lock nut. -
Start Generator
Move generator outside to a flat, level surface, away from doors, windows and vents.
DENGER****
Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust contains
carbon monoxide. This is a poison you cannot see or smell. NEVER use inside a
home or garage, EVEN IF doors and windows are open. Only use OUTSIDE and far
away from windows, doors and vents.
Avoid other generator hazards. READ MANUAL BEFORE USE.
DENGER Do not overload generator or electrical cords. Consult operation
manual.
1. | Turn fuel valve under tank to ON position.
---|---
| Turn engine switch located on control panel to ON(I) position.
| Move choke lever located on engine to START position.
| Pull cord starter to start engine.
| Move choke lever to RUN Position.
| Plug in items to be powered, using only grounded extension cords.
5. Shutdown and Storage
| Remove any load from the generator.
---|---
| Run the generator at no load for 2 minutes and then turn engine switch to
OFF(O) position.
| Turn fuel valve to OFF(O)position.
If generator is to be stored for longer than 30 days, refer to The operator’s manual for further Instruction.
Questions? Call 1-855-888-3598 or email support@a-ipower.com