somfy Oximo RTS 550R2 Tubular Motor Instructions
- June 4, 2024
- somfy
Table of Contents
somfy Oximo RTS 550R2 Tubular Motor
Auto Set Both Limits
To allow the OXIMO to auto set its limits, the product must have rigid links and bottom stops.
STEP 1
Wake the motor by pressing the UP and DOWN buttons simultaneously until the
motor jogs.
Note: After every command the motor will jog to confirm.
STEP 2
Check the direction of rotation with the UP or DOWN button. If needed, change
the direction of rotation by pressing and holding the MY button until the
motor jogs.
STEP 3
Press the UP and DOWN buttons simultaneously until the motor jogs.
STEP 4
Press and hold the MY button until the motor jogs to confirm the limit
setting.
STEP 5
Press and hold the PROGRAM button on the back of the transmitter until the
motor jogs. The buttons no longer have to be held for the motor to run. The
motor will auto detect the limits from the physical stops.
Top Limit Set by User, Bottom Limit Auto Set
To allow the OXIMO to auto set its bottom limit, the product must have rigid links.
STEP 1
Wake the motor by pressing the UP and DOWN buttons simultaneously until the
motor jogs.
Note: After every command the motor will jog to confirm. STEP 2
Check the direction of rotation with the UP or DOWN button. If needed, change
the direction of rotation by pressing and holding the MY button until the
motor jogs.
STEP 3
Run the motor to the desired upper limit. Press the MY and DOWN buttons
simultaneously until the motor starts to run downward. Use the MY button to
stop the motor.
STEP 4
Press and hold the MY button until the motor jogs to confirm the limit
setting. STEP 5
Press and hold the PROGRAM button on the back of the transmitter until the
motor jogs. The buttons no longer have to be held for the motor to run. The
motor will auto detect the non-set limit from the physical stop.
General Information **
**
ADJUSTING THE MANUALLY SET LIMITS AFTER THE MOTOR HAS BEEN PROGRAMMED
- To change the upper limit, run the motor to its upper limit and let it stop. Press the UP and DOWN buttons simultaneously until the motor jogs. Run the motor to the new desired upper limit. Press and hold the MY button until the motor jogs. Check the new limit.
- To change the lower limit, run the motor to its lower limit and let it stop. Press the UP and DOWN buttons simultaneously until the motor jogs. Run the motor to the new desired lower limit. Press and hold the MY button until the motor jogs. Check the new limit.
Bottom Limit Set by User, Top Limit Auto Set
To allow the OXIMO to auto set the top limit, the product must have a bottom stop.
STEP 1
Wake the motor by pressing the UP and DOWN buttons simultaneously until the
motor jogs.
Note: After every command the motor will jog to confirm.
STEP 2
Check the direction of rotation with the UP or DOWN button. If needed, change
the direction of rotation by pressing and holding the MY button until the
motor jogs. STEP 3
Run the motor to the desired upper limit. Press the MY and DOWN buttons
simultaneously until the motor starts to run downward. Use the MY button to
stop the motor near the desired lower limit. STEP 4
Press and hold the MY button until the motor jogs to confirm the limit
setting.
STEP 5
Press and hold the PROGRAM button on the back of the transmitter until the
motor jogs. The buttons no longer have to be held for the motor to run. The
motor will auto detect the non-set limit from the physical stop.
STEP 6
Press and hold the PROGRAM button on the back of the transmitter until the
motor jogs. The buttons no longer have to be held for the motor to run. Double
check the limits are in the desired position.
Important: The programming button in step 6 will not work until the limits have been confirmed per step 5.
General Information
- To add or delete a remote/channel, press the PROGRAMMING button on the back of an already programmed remote/channel until the motor jogs. Next, press the PROGRAMMING button on the back of the remote/channel you wish to add or delete until the motor jogs.
- To reset the motor to factory mode, start with the motor connected to power. Cut power for 2 seconds, reconnect power for 10 seconds, cut power for 2 seconds and then reconnect power. The motor should jog or start to run. (If this does not happen, repeat the power cuts until the motor does run). Allow the motor to stop on its own. (Do not press stop, up or down or you will have to repeat the double power cut). Once the motor stops on its own, press and hold the PROGRAMMING button until the motor jogs twice.
About Somfy®
Somfy has been improving everyday life for more than 270 million people by
designing and manufacturing intelligent motorization solutions for interior
window coverings and exterior solar protections. Somfy innovates to automate
and connect shades, blinds, draperies, awnings, rolling shutters, exterior
screens & pergolas for commercial and residential buildings in 58 countries
across the globe. With 170+ million motors produced over the last half
century, Somfy is committed to creating reliable and sustainable solutions
that promote the best way of living and well-being for all.
SOMFY SYSTEMS INC
SOMFY NORTH AMERICAN HEADQUARTERS
- 121 Herrod Blvd.
- Dayton, NJ 08810
- P: (800) 22-SOMFY (76639)
- NJ: 609-395-1300
- F: 609-395-1776
FLORIDA
- 1200 SW 35th Ave.
- Boynton Beach, FL 33426
- P: (800) 22-SOMFY (76639)
- F: 561-995-7502
- CALIbFORNIA
- 15301 Barranca Parkway
- Irvine, CA 92618-2201
- P: (800) 22-SOMFY (76639)
- F: 949-727-3775
SOMFY ULC
- SOMFY Canada Division
- 6411 Edwards Blvd
- Mississauga, ON L5T 2P7
- P: (800) 66-SOMFY (76639)
- CN: 905-564-6446
- F: 905-238-1491
- www.somfypro.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>