Adexa 6G-TRM40 Commercial Gas Pasta Boiler Instruction Manual

June 15, 2024
Adexa

Adexa 6G-TRM40 Commercial Gas Pasta Boiler

Product Information

  • Specifications
    • Model: 6G-TRM40, 6G-TRM60
    • Type: Counter Top Gas Pasta Boiler
    • Features: Stainless steel tubular burner, flame failure protection function, thermostatic control function, pilot flame standby function, pulse ignition function

Product Usage Instructions

  • General Information
    • The appliance is equipped with a stainless steel tubular burner and various safety functions. Before installing the appliance, it is crucial to read the instructions carefully for safe and proper installation, use, and servicing.
    • Keep this manual in a safe place for reference.
    • The appliance should be installed following the manufacturer’s instructions and in compliance with local regulations.
    • Only qualified personnel should connect the appliance to the gas supply, and all operators must be specifically trained in its operation.
  • Attention
    • The appliance is designed for commercial use only and should not be used in a home setting.
    • After use or when the operator is not available, switch off the appliance and cut off the gas supply.
    • Avoid using a water jet to flush the appliance to prevent damage to control components.
    • Regularly clean the stainless steel surface of the appliance.
  • Warning
    • The appliance is suitable for low-pressure gas only. When using LPG, a low-pressure relief valve must be used; medium or high-pressure relief valves are prohibited.
    • Any modification, incorrect installation, adjustment, or maintenance can result in property loss or injury.
    • Contact the supplier for any necessary adjustments or maintenance, which should be performed by authorized professionals.
    • Keep flammable liquids, gases, and incendiary objects away from the appliance.
    • Do not change the positions of the air inlet port and flue gas outlet port.
    • If there is a gas leakage, immediately shut off the general gas valve, avoid using electronic on/off buttons or phones, and go outside to call the service center for professional assistance.
    • The appliance should not be used empty; ensure to fill water before operation and monitor the water temperature to prevent dry combustion incidents.
  • FAQ (Frequently Asked Questions)
    • Q: Can I use this appliance for home cooking?
    • A: No, this appliance is designed for commercial use only and should not be used in a home setting.
    • Q: How should I clean the appliance?
    • A: Periodically clean the stainless steel surface of the appliance using appropriate cleaning agents and methods recommended by the manufacturer.
    • Q: What should I do in case of a gas leakage?
    • A: In case of gas leakage, immediately shut off the general gas valve, avoid using electronic on/off buttons or phones, and go outside to call the service center for professional assistance.
    • Q: Can I use high-pressure relief valves with this appliance?
    • A: No, it is prohibited to use medium or high-pressure relief valves with this appliance. Only low-pressure relief valves should be used.

Important:

  1. You are advised to read these instructions first before installation commences.
  2. This manual must be handed to the end user after installation and commissioning.
  3. These instructions are only valid if the country code appears on the appliance. If the code does not appear on the appliance, refer to the technical instructions for adapting the appliance to the conditions for use in that country.

General information

  • The appliance is equipped with a stainless steel tubular burner. It has a flame failure protection function, thermostatic control function, pilot flame standby function, and pulse ignition function.
  • Before installing the appliance, please read the instructions in this manual carefully, as they contain important information on how to install, use, and service the appliance safely, properly, and effectively.
  • Keep this manual in a safe place so that it can be used as a reference by other operators of the appliance.
  • This appliance should be installed following the instructions provided by the manufacturer and in compliance with all applicable local regulations. This appliance should be connected to the gas supply by qualified personnel only.
  • All personnel in charge of using this appliance should be specifically trained in its operation.
  • In the event of failure or malfunction, switch off the appliance. The periodic functional checks requested in this manual should be carried out according to the instructions. Have the appliance serviced by a technically qualified person duly authorized by the manufacturer that uses genuine spare parts?
  • Failure to comply with the above may jeopardize the appliance’s safety.

Attention

  • The appliance is only for commercial use, not for home use.
  • When the appliance finishes work or the operator is not available to the appliance, please switch off the appliance and cut off the gas supply.
  • Never use the water jet to flush the appliance in case of damage to the control components of the appliance.
  • Please clean the stainless steel surface of the appliance periodically.

Warning

  • The appliance is only suitable for gas with low pressure. When supplying LPG, it must use low pressure relief valve. It is prohibited to use any medium or high-pressure relief valve.
  • Any refitting and wrong installation, adjustment and maintenance can cause property loss and casualty. Please contact the supplier if you need to adjust or maintain the appliance. And all these operations should be done by authorized professionals.
  • Do not put flammable liquid, gas or other incendive objects around the appliance for your safety sake.
  • Do not change the positions of the air inlet port and flue gas outlet port.
  • If there is a gas leakage of the appliance, please shut off the general gas valve immediately. Don’t press any electronic on/off button, and use any phones inside. Go outside and call the service center to ask professional staff to maintain it.
  • The appliance can not be used empty. Ensure to fill water before operation. Never ignite without water in a tank. please watch the temperature of the water. No dry combustion, to avoid incident!

Instruction for installation

Installation drawings (Picture 1)

Installation

  • Before installing the product, verify that the type of gas (natural or propane) agrees with the specifications on the naming plate which is located at the rear part of the unit.

  • If gas cylinder is used, please choose as per local standard. The max diameter is 40cm, the max length is 1.2 meter. put it in dry cool position.

  • The appliance can be installed as a countertop type. Also, you can dismantle the 4 legs, and then screw the body with the cabinet, but first you should have a matched cabinet.

  • The appliance should be both installed and serviced by all applicable regulations and standards in force.

  • The appliance should be connected to a potable water supply by national regulations.

  • Installing the appliance should be by EN1717 and national water regulations in force.

  • The appliance is not suitable for built-in installation. Because the appliance will be working without enough oxygen supplied due to the restricted space and the combustion products cannot be discharged from the kitchen immediately and completely, which is very harmful to the operators’ health.

  • The appliance cannot be installed onto an inflammable floor or other combustible objects. If the appliance is installed with its sides next to the walls, please keep a minimum clearance of 10cm away from the walls.

  • The appliance should be installed in a well-ventilated area, if possible under a vent hood, in compliance with all applicable regulations in force. This will ensure that all burnt gases produced during the combustion process are completely exhausted.

  • Before installation, remove all packaging materials from the appliance. Certain parts are wrapped up in adhesive film, which should be carefully removed. Remove any glue traces left on the appliance thoroughly using non-flammable solvents. It is forbidden to use abrasive substances.

  • Check that the appliance is pre-set to use the gas family available at the place of installation. Make sure the supply gas is the same as the gas that the appliance allows to us.

  • If the available gas is different from the gas that the appliance requires to use, please don’t connect it, and mark the gas pipe with a yellow color mark.

  • The appliance should be connected to the gas supply using metal pipes –either rigid or flexible– having an adequate diameter. Any flexible hose or tubing that may used for supplying gas can not exceed 1.5m.

  • The used gas supply tube or hose shall comply with the national requirement in the form. The user should examine the gas tube periodically. If necessary, replace the tube or hose in time.

  • When joining pipe fittings, never use oakum or Teflon as their residues could get to the valve and jeopardize its operation. Instead, interpose a seal gasket suitable for use in gas systems. Do not forget to fit a shutoff valve on the gas supply line upstream of the appliance, which should be closed whenever the appliance is not in operation.

  • A 3/4″ male BSP line for the gas connection is located near the lower right rear corner of the product. The serial plate indicates the type of gas the unit is equipped to burn (natural gas or propane). The product should be connected ONLY to the type of gas for which it is equipped.

  • An adequate gas supply is imperative. Undersized or low-pressure lines will restrict the volume of gas necessary for satisfactory performance. A combination gas valve and pressure regulator, which is provided with each unit, is set to maintain a 2.0kPa manifold pressure for natural gas or 2.75kPa/3.7kpa/5.0kpa manifold pressure for propane gas.

  • Fluctuations of more than 25% on natural gas or10% on propane gas will create problems and affect burner operating characteristics.

  • The available gas pressure should be the same as that indicated on the naming plate.If the gas pipe pressure is higher or lower than the rated pressure at 15%, please install a pressure regulator to adjust the gas pressure.

  • After connecting the appliance to the gas system, check for leaks at joints and pipe fittings; to do so, use soapy water or a specific leak detector (spray).

  • Checking gas supply pressure after installation. Gas supply pressure can be measured with a liquid-filled pressure gauge (for example, a U-shaped pressure gauge, minimum scale division 0.1 mbar) or a digital gauge.

Procedure as follows:

  • a. Remove the panel, unscrew the screw on the pressure port (picture 2)
  • b. Place the pressure gauge;
  • c. Start up the appliance by following the instructions in the user’s manual;
  • d. Check supply pressure;
  • e. After the check, remove the pressure gauge;
  • f. Replace the sealing screw

The appliance can not be used empty. Ensure to fill the water before operation. The rear side of the vessel carries a permanently punched mark indicating the maximum and minimum operating level of the filling. Fill the Water till the level is between maximum and minimum mark. If water is below the minimum mark, fill the water.

Ignition (picture 3, picture 4)

  • Before lighting, check all joints in the gas supply line for leaks. Use soap and water solution. Do not use an open flame.
  • After the piping has been checked for leaks, fully purge gas pipes to remove air.
  • Rotate the knob counter-clockwise; make sure the mark on the knob pointing to the position 0.
  • Then push the knob, and press the impulse ignition device at the same time. (picture 6) ( It may take several times to ignite the flame, because there will exist air in the pipe, only after air comes out then gas flow in and ignition can work.)
  • When the pilot flame is ignited, after 20 seconds please release your hand from the knob.
  • Rotate the control knob to position , the burner is operating at maximum power.
  • Rotate the control knob to position , the burner is operating at minimum power.

Extinguish fire.

  • Switch off the knob.
  • Shut off the gas valve to cut off the gas supply to the burner.
  • Replace the main burner nozzle, adjust the air inlet, and replace the pilot nozzle
    • Note: Layman is not allowed to replace the nozzle. (picture 5)
  • (Picture 6)
  • Move the base of the nozzle left and right to adjust the primary air
  • adjust the orifice to the desired position. In the below picture, you can find the suggested position. The distance is between the burner base and the orifice.

Replace the nozzle of the main burner ( see picture 5)

  • Prepare one Phillips screwdriver and two proper open spanners
  • Dismantle the control panel, and then remove the nut and aluminum pipe, dismantle the joint of the nozzle, unscrew the jam nut, remove the nozzle, and replace a new proper nozzle.
  • Screw the two jam nuts, and fit all the dismantled parts again. Finally, fit the control panel.

Replace the pilot nozzle. (see pictures 7 and 8)

  • Use the proper spanner on the nut of the nozzle to balance the torsional stress.
  • Then unscrew the screw of the thermocouple and aluminum pipe, and dismantle the thermocouple and aluminum pipe.
  • Remove the pilot nozzle, and then replace a new proper one. There is no need to adjust the primary air.

Technical specifications table

Model 6G-TRM40 6G-TRM60
Dimension (mm) 400×652×540 600×652×540
Height of working table 335 335
Capacity (L) 17L 28L
Drainage outlet size R    1/2″ R    1/2″
Gas inlet size R    1/2″ R    1/2″

Gas

| orifice dia.| Pilot orifice dia| Gas pressure| Pilot heat input| Reduced heat input| Gas heat input| Gas Consumption
---|---|---|---|---|---|---|---
6G- TRM60| 6G- TRM40| 6G- TRM60| 6G- TRM40
G30| 0.9mm| 0.25mm| 29mbar| 0.20kW| 1.3kW| 3.5kWx2| 3.5kW| 552g/h| 276g/h
G30| 0.9mm| 0.25mm| 37mbar| 0.23kW| 1.4kW| 3.8kW x2| 3.8kW| 600g/h| 300g/h
G30| 0.9mm| 0.25mm| 50mbar| 0.25kW| 1.45kW| 4.3kW x2| 4.3kW| 678g/h| 339g/h
G20| 1.5mm| 0.40mm| 20mbar| 0.24kW| 1.6kW| 4.1kW x2| 4.1kW| 868l/h| 434l/h
G25.3| 1.5mm| 0.40mm| 25mbar| 0.18kW| 1.5kW| 3.8kW x2| 3.8kW| 914l/h| 457l/h

Use and Maintenance

Attention to use

  • The appliance is designed to cook pasta. Any other usages are not permitted.
  • Before using, please clean the water tank first:
    • a. Use the towel to wash it clean with neutral detergent, and finally rinse it with water.
    • b. Don’t use hard detergent, and steel wire or sharp tool to scrape the surface of appliance in case of damage it.
  • Don’t use water jet directly flush the body of appliance, and don’t use detergent which contains corrosive substance, such as hydrochloric acid, to wash the surface of the appliance.
  • Don’t change the air inlet port and flue gas outlet port of the appliance in case of serious accidents occurring.
  • If the appliance will remain idle for a certain period of time, clean it and wipe it dry first, and then apply a film of a suitable product (such as vaseline oil spray or similar products) to protect it. Shut off gas and power supply upstream of the appliance.
  • Only qualified personnel are allowed to carry out service and maintenance operations. The following maintenance operations should be performed at least once a year:
    Checking for proper operation of all control and safety devices;

Checking burner combustion, i.e.:

  1. ignition;
  2. combustion safety;
  3. checking for proper operation throughout the entire HIGH-to-LOW control range.
    • All packaging materials must be disposed of in compliance with applicable local regulations in force where the appliance is being installed. Packaging materials should be separated according to their types and delivered to specific collection sites.
    • Ensure compliance with environmental protection regulations.

Scald Warning

  • When the appliance is working, don’t directly touch the surface of the appliance with your hands in case of scald.

Troubleshooting

  • Cannot ignite the pilot flame:
    • a. The installation or the connection of the igniter is wrong. Please install the ignitor correctly.
    • b. The igniter’s plug or the wire of the plug is broken. Please replace a new one respectively.
    • c. The gas pressure is not enough. Adjust the relive valve to get proper pressure.
    • d. The nozzle is blocked. Please unblock the nozzle.
    • e. The connection of the thermocouple is not good. Please fasten the connection.
    • f. The thermocouple is damaged. Replace a new one.
    • g. The gas control valve has a problem. Ask the professional people to repair or replace a new one.
  • The pilot flame is on but the main burner can not be ignited.
    • a. The gas pressure is not enough. Adjust the relive valve to get proper pressure.
    • b. The nozzle of the main burner is blocked. Unblock the nozzle.
    • c. The gas control valve has a problem. Ask the professional people to repair or replace a new one.
  • Turn off the gas valve and it has a lit-back sound.
    • a. The diameter of the nozzle is not matched with the gas source. Please adjust the nozzle diameter.
    • b. The gas pressure is too low. Adjust the relief valve.
  • It has red flame and black smoke.
    • a. The diameter of the nozzle is not matched with the gas source. Please adjust the nozzle diameter.
    • b. The gas is nearly used out. Replace the gas.
    • c. Reduce the gas flow.
    • knob, orifice, thermocouple, drainage valve, igniter, and battery can be replaced by a qualified person, if necessary.
    • Gas valve, burners, and inlet pipes are protected by the manufacturer or agent. They can not be replaced or adjusted by end users to ensure the air-tightness of the appliance.

EC Declaration of Conformity

Adexa Direct Limited declares that:

  • Equipment Type: Gas pasta boiler
  • model: 6G-TRM40, 6G-TRM60
  • Imported By: ADEXA DIRECT LIMITED Unit 1 Swift Point, Cosford Lane, Swift Valley Industrial Estate, Rugby, CV21 1QN, UK
  • Brand: ADEXA
  • Application of Council Directive(s): (EU) 2016/426 (9 March 2016)
  • Standards:
    • EN 203-1:2021, EN 203-2-11:2006
    • EN 203-3:2009

I, the undersigned, hereby declare that the equipment specified above conforms to the above Directive(s) and Standard(s).

  • Date: 01. 06. 2023
  • Signature:
  • Full Name: Hakan Baykal
  • Position: Purchase Manager

Declaration of Conformity

Adexa Direct Limited declares that:

  • Equipment Type: Gas pasta boiler
  • Model: 6G-TRM40, 6G-TRM60
  • Imported By: ADEXA DIRECT LIMITED Unit 1 Swift Point, Cosford Lane, Swift Valley Industrial Estate, Rugby, CV21 1QN, UK
  • Brand: ADEXA
  • Application of Council Directive(s): ( E U ) 2016/426
    • 2018 No 389
    • UK SI 2019/696
    • 2019 No 1246
  • Standards: BS EN 203-1:2021, BS EN 203-2-4:2005, BS EN 203-3:2009

I, the undersigned, hereby declare that the equipment specified above conforms to the above Directive(s) and Standard(s).

  • Date: 15.6.2023
  • Signature:
  • Full Name: Hakan Baykal
  • Position: Purchase Manager

CONTACT

ADEXA DIRECT LIMITED

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals