VisionTechShop DSW-100RS Pos Interface Dual Display Owner’s Manual
- June 12, 2024
- VISIONTechShop
Table of Contents
VisionTechShop DSW-100RS Pos Interface Dual Display Owner’s Manual
OPERATING WARNING
A Please follow the instructions below to operate the product to ensure product and personal safety.
Before installation, it is important to check whether the power supply indicated by the brand matches to ensure the normal operation.
Sharing sockets with other high-power devices can cause large fluctuations.
Make sure that one scale uses a matching power outlet.
Do not insert metal D or flammable objects on the interface to I avoid damage
to the machine or fire.
Do not insert metal D or flammable objects on the interface to I avoid damage to the machine or fire.
Keep your fingers dry when inserting or removing the power Plug to avoid electric shock.
Metal objects or liquids can cause fire or rust in the scale. Keep an appropriate distance from the scale to avoid damage.
Do not scratch or modify the power cord, bend excessively or place heavy objects on top to avoid fire or short circuit.
If the scale falls, please turn off the switch and power Plug immediately, suspend use, and contact the service personnel in time to ktt avoid fire or electric shock.
Immediately turn off the switch and Plug when metal fragments or liquids enter the interior, suspend use and contact service (01″ o, personnel to avoid fire or electric shock.
Make sure that the scale and extension cable are properly grounded, as this can cause external metal parts to be electrostatically charged to prevent fire or electric shock.
When the scale emits smoke or strange smell, please stop using it immediately, turn off the switch and power supply, and contact the service personnel in time.
To avoid j) disconnection of the power cord or peeling of the cord when unPlugging the power cord, do not pull on the cord.
Do not remove, repair or modify the scale body, high-voltage, high-heat parts or internal edges to ensure personal safety.
NOTICE
If you have any questions, please contact your local dealer or visit our
website
www.VisionTechShop.com Thank you.
CONVENTIONAL
Product Specification
SPECIFICATION
Model| DSW-100
Maximum capacity| 6 lb| 15 lb| 30 lb| 60 lb
Minimum graduation| 0.002 lb| 0.005 lb| 0.01 lb| 0.02 lb
Maximum tare weight| -5.998 lb| -14.995 lb| -29.99 lb| -59.98 lb
**** Auxiliary capacities| 3000 g| 6000 g| 15000 g| 30000 g
3.000 kg| 6.000 kg| 15.000 kg| 30.000 kg
6.000 lb| 15.000 lb| 30.000 lb| 60.00 lb
96.00 oz| 240.00 oz| 480.00 oz| 960.0 oz
A/D conversion speed| 10 Updates / SEC
Internal resolution| 1/60000
Display type| LCD display
Power source| D size battery 1.5V x 4EA (6V),DC 9V 300mA
Operating time| Alkaline Battery:2500hr
Operating temp.| -10℃~40℃ / 14℉~104℉
Keys| UNIT, TARE, ZERO, ON/OFF
Communication| RS-232C
Power consumption| 0.15 W
Stainless weighing pan (in/mm)| (W)9.06in x (D)7.72in/(W)230mm x (D)196mm
Product size (in/mm)| (W)9.06in x (D)11.22in x (H)4.41in/(W)230mm x (D)285mm x
(H)112mm
Product weight| 3.31lbs/1.5 kg
Option| Customer(Rear) Display /RS-232C Interface
Indicator Display
Notes:
When the battery power is higher than 70%, 3 grids are displayed, and the
battery voltage is about 5.7V; When the battery power is lower than 70% and
higher than 30%, 2 grids are displayed, and the battery voltage is about 5.1V;
When the battery power is less than 30%, one grid is displayed, and the
battery voltage is about 4.2V.
Basic Function Keys
Keyboard type | Specific display |
---|---|
**** Weight | This key is used to convert the unit of weight lb → oz → g → |
kg → lb.
| Tare mode key| This key is used to set the tare or delete the
tare*Tare = A container.
| Zero key| This key is used to correct the weight to zero.
| Power key| Used to switch on/off the scale.
Dimension
Front view
Back view (option)
Side view
**Top view
**
Interface (Option)
Display
Screen
BASIC OPERATION
Booting
Note:
- During the field check, press the [ZERO] key to exit and enter the weighing mode.
- When the battery capacity indicator shows only one bar, it means that the internal battery voltage is too low, please replace the battery. (Please use 4 alkaline batteries of R20P SIZE-D 1.5V ).
Power On/Off Operation
Method 1: Click [ON/OFF] button to shut down
Method 2: Unplug the AC power and shut down
Zero Operation
Make sure that the scale is in a stable state and put a heavy object, the
weight must be less than the set allowable zero setting range, such as 0.500lb
Click [ZERO] and remove the heavy object, which shows -0.500lb.
Click [ZERO] again to reset to zero.
Note:
If the weighing item exceeds the zero range, it will sound beep beep. Click
[ZERO] again to return to the weighing mode.
Tare Operation
Make sure that the scale is in a stable state and put on a heavy object. The
weight must be less than the allowable tare range, such as 2.500lb.
Press [Tare] key to reset the displayed weight to zero. Remove the object and
the display will show the tare weight.
Remove the heavy object, and the display will show -2.500lb.
Click [TARE] again to resume zero setting.
Note:
If the placed weight exceeds the allowable tare range, the tare operation will
not be performed after pressing the tare key.
Weight Unit Change
-
Make sure the scale is stable
-
Put a heavy object on the weighing pan, such as 0.545lb
-
To enable this toggle function, SPEC03 bit.2 must be set to 1.
Click the [UNIT]key, it displays 0.247kg.
Press [UNIT] key again to exit kg mode.
-
After removing the heavy object, click [ZERO] to resume zero setting.
Backlight Brightness Setting
-
Make sure the scale is stable
-
Press and hold the [UNIT] key for 5 seconds, knowing that “bL.S 3” appears on the screen, and the displayed “3” is the backlight brightness level.
-
Click [UNIT] to increase the brightness, the minimum brightness is 0 (without backlight), and the maximum brightness is 9.
-
Click [ZERO] to save and exit.
Note: When working with batteries, decrease the backlight brightness as much as possible to reduce battery consumption and extend battery life.
Backlight Off Setting
-
Make sure the scale is stable.
-
Long press [ZERO] and click [UNIT] three times to enter user Settings.
-
Click [ZERO] to change the default Settings.
-
The figure shows the value of the backlight off. The [UNIT] key inputs “0”, the [TARE] key inputs “1”, and the order is changed from right to left.
BIT 3 / BIT 2| Backlight auto-offtime setting| 00:10 seconds|
01:20 seconds| 10:30 seconds| 11:Do notclose
---|---|---|---|---|---
BIT 1| Allow automaticentry into power saving mode| 0:Allow| 1:Forbid
BIT 0| Automatic shutdown timesetting| 0: There is no automatic
shutdown| 1: Allows automatic shutdown
Notes:
BIT3/BIT2: When the backlight brightness is set to 0, the backlight will
not automatically get turned
on.
BIT1: Power saving mode enters in 60 seconds.
The default is 0011, the backlight turns off automatically after 10 seconds; do not enter the power saving mode; allow automatic shutdown after 3 minutes of no operation.
-
Modify as required and click [ZERO] to save
-
Make sure that BIT 3 is “0” in SPEC 01, which means that changing the backlight Settings is allowed. By default, the status is allowed, that is, 0.
The values are tabulated below.
BIT 3 | Backlight functionsettings | 0:Allow | 1:Forbid |
---|---|---|---|
BIT 2/BIT 1/BIT 0 | RS-232 baud rate setting | 000: Portclosed | 001: 1200 |
010: 2400 | 011: 4800 | ||
100: 9600 | 101:19200 | 110:38400 | 111:57600 |
Notes:
The default is 0100, the backlight function is turned on; the baud rate of
RS-232 is 9600.
Power Off Time / Saving Mode
-
Make sure the scale is stable.
-
While holding the [ZERO] key, press the [UNIT] key three times.
-
Click [UNIT] key to modify Spec 00. The display will show SPC 00, and then press the [ZERO] to enter the power saving mode. The [UNIT] key inputs “0”, the [TARE] key inputs “1”, and the order is changed from right to left. If only BIT 1 is modified, “0” is allowed to enter the power saving mode, and “1” is unable to enter.
BIT 3 / BIT 2| Backlight auto-offtime setting| 00:10 seconds| 01:20 seconds| 10:30 seconds| 11:Do notclose
---|---|---|---|---|---
BIT 1| Allow automaticentry into power saving mode| 0:Allow| 1:Forbid
BIT 0| Automaticshutdown time setting| 0: There is no automatic shutdown| 1: Allows automatic shutdown
Notes:
BIT3/BIT2: When the backlight brightness is set to 0, the backlight will not
automatically get turned
on.
BIT1:Power saving mode enters in 60 seconds.
The default is 0011, the backlight turns off automatically after 10 seconds;
do not enter the power
saving mode; allow automatic shutdown after 3 minutes of no operatio
- Click [ZERO] to save and exit
Note: Automatic shutdown function, only in use of dry battery effective.
ERROR MESSAGE
ERRORS | REASONS | SOLUTIONS |
---|---|---|
**** OF | **** Weight overload | Remove or re-calibrate the weight to clear |
the errormessage display.
UF.| Gross or net weight is negative| Zero or clear the tare to clearthe error
message display.
888888| When the [ZERO] button is pressed| Release the zero button
toclear the error message display.
0 – E r| System zero error| Remove or re-calibrate the weight to
clear the errormessage display.
z r . E r r| Exceeds the allowable range| Remove or re-calibrate
the weight to clear the errormessage display.
**** S O n| **** Calibration switch is in “on” state| After the
prompt appears for 5 second, the error message display will be
automaticallycleared.
**** S O F F| **** Calibration switch is in “off” state| After
the prompt appears for 5 second, the error message display will be
automaticallycleared.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>