Adexa DW7R Professional Gelato and Ice Cream Serving Display Counter 7 Tubs Instruction Manual
- October 27, 2023
- Adexa
Table of Contents
Adexa DW7R Professional Gelato and Ice Cream Serving Display Counter 7 Tubs Instruction Manual
Thank you for choosing and purchasing our product. Please carefully read the operation instructions before use for a correct application and satisfactory effect.
Imported by: Name: Adexa Direct Limited Address: Unit 1 Swift Point, Cosford
Lane, Swift Valley Ind Est, Rugby CV21 1QN United Kingdom
www.adexa.co.uk
service@adexa.co.uk
T:(+44) 01788 222 410
General
- Top brand fully enclosed compressor is used on the The refrigerant R290/R134a is of an environmentally friendly agent. The temperature is quite even inside the freezer.
- Double hollow transparent glasses are used on body. It features an artistic and elegant appearance, perfect perspective and easy. access.
Structure and Parts
Handle and Erection
Preparation and Power Supply
Use and Caution
-
Before use:
Plug the freezer on 220-240V~ exclusive socket.
After the freezer running, put hand on the air suction to confirm it is sufficient cold. -
Digital temperature controller
Features of function
It is a mini-sized and integrated intelligent controller and applicable to the compressor of one Hp.
The main functions are :Temperature Display/Temperature Control/Manual, automatic defrost by turning off/illumination Control / Value Storing /Self Testing /Parameter Locking
Front panel operation
-
Set temperature
Press button, the set temperature is displayed.
Press button to modify and store the displayed value.
Press button to exit the adjustment and display the cold-room temperature. -
If no more button is pressed within 10 seconds, the cold-room temperature will be displayed.
-
illumination: Press button, it lights; Press again, it stops. Manual start/stop defrost: Press~ button and hold for 6 seconds to defrost or stop defrost.
-
Refrigerant LED: During refrigeration, the LED is on; When the cold room temp. is constant, the LED is off; During the delay start, the LED flashes.
-
Defrost LED: during defrosting, the LED is on; When is stops defrosting, the LED is off, During the delay display of defrost, the LED flashes.
-
Digital controller reset
When display shows “Disorder”, press ” ” button for 2s until buzzer rings, quickly press ” ” button for 6s until buzzer rings again, the display will flash for 3s and it
restores factory setting.
3. Cautions
Shorten the door open time and reduce open frequency is good to keep a cold temperature inside the freezer.
Never block the air suction and outlet. Keep air circulation and refrigeration capability. Do not make food congested as it will influence the cooling effect.
The time of putting Ice-cream inside: the Ice-cream can be put into the freezer only after the freezer reaches the storage temperature and stops automatically.
Try to reduce the open times and keep inside cold in case the power is cut off. Only skilled service man is allowed to repair the damaged power cable with special tools. Never touch compressor to avoid from scald.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the
appliance. The operation manual are not suitable for the persons (including
children) with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge. Do not store explosive substances such as aerosol
cans with a flammable propellant
in this appliance.
During normal operation, the emission noise level does not exceed 70dB(A).
The maximum loading of the The climatic class of the appliance is 4, the Units
are suggested to be used at 16°C-32°C (60.8°F-89.6°F) ambient temperature.
To avoid damages or other problems, this product can not be put or stored with
any corrosive food .
WARNING: Keep ventilation openings, in the appliance enclosure or in the built-in structure, clear of obstruction.
WARNING: Do not use mechanical devices of other means to accelerate the
defrosting process, other than those recommended by the manufacturer.
WARNING: Do not damage the refrigerant circuit.
WARNING: Do not use electrical appliances inside the food storage compartments
of the appliance, unless they are of the type recommended by the manufacturer.
ADDITIONAL WARNING
Caution: risk of fire. The height of the triangle in the symbol shall be at least 15mm.
Maintenance
-
Notice
Often keep the freezer clean and periodical maintenance is necessary. Always unplug the socket before maintenance. Never use damaged plug or loose socket to prevent from electric shock or short circuit. Never flush the freezer. Never use alkali detergent, soap, gasoline, acetone or brush. -
Clean outside
Dip soft cloth in neutral detergent(tableware detergent)to clean the outside of and the n wipe it with dry soft cloth. -
Clean inside
Take pan out for cleaning with water.
Use soft cloth to wipe the box. -
Shut down freezer for a long time
Take all food out and unplug the wall socket.
Clean both inside and outside of the freezer thoroughly and open the door for sufficient dry.
The glass breaks easily. Keep the glass far from children.
Trouble Shooting
Note
Following phenomena are not troubles
The murmur of water is heard when the freezer is working. It is a normal
phenomenon as the coolant is circulating in the system.
In wet season, condensation might be found on the outside of the freezer. It
is not a trouble, which is caused by high humidity. Simply use cloth to wipe
it.
Principle of Refrigeration System and Electric Circuit Diagram
The principle of compression refrigeration consists of “compression” , “condensation” , “throttling” and “vaporization” . The compression is undertaken by compressor, the condensation is completed by condenser, the throttling valve is executed by capillary and the vaporization is implemented by evaporator. When the coolant is circulating in the closed refrigeration system, the compressor sucks coolant, which has absorbs heat in evaporator, the coolant becomes a high pressure and high temperature gas. In condenser, it dissipates heat in air, while the coolant is re-liquefied and throttled in capillary and then enters into evaporator with low pressure. The liquefied coolant quickly boils and vaporizes into gas when the pressure suddenly drops. Meanwhile, it absorbs heat inside the refrigerator. And the compressor sucks the low pressure and low temperature gaseous coolant. It is circulating in this way up to realization of intended refrigeration.
Circuit Diagram
Major Parameters
Note
- The electric circuit diagram and parameters on the product nameplate are final ones if they have been changed.
- The design might be improved without notice.
WARNING : Refrigerant is facility burning of R290, please protect against fire.
Meaning of crossed out wheeled dustbin:
Do not dispose of electrical appliances as unsorted municipal waste, use
separate collection facilities.
Contact you local government for information regarding the collection systems
available.
If electrical appliances are disposed of in landfills or dumps, hazardous
substances can leak into the groundwater and get into the food chain, damaging
your health and well-being.
When replacing old appliances with new ones, the retailer is legally obligated
to take back your old appliance for disposals at least free of charge.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>