westermo RedFox 5528 Series Industrial Routing Switches User Guide

June 15, 2024
westermo

RedFox 5528 Series Industrial Routing Switches

RedFox 5528 Series

Specifications

The RedFox 5528 Series is an industrial routing switch designed
for high-performance networking in demanding environments.

Interface Specifications

  • Number of Ethernet Ports: 28
  • Interface Type: Gigabit Ethernet
  • Power over Ethernet (PoE): Yes
  • Serial Ports: 2
  • Power Input: 24-48 VDC
  • Operating Temperature: -40°C to 70°C

Type Tests and Environmental Conditions

The RedFox 5528 Series has undergone rigorous type tests to
ensure its reliability and performance in various environmental
conditions. It complies with the following standards:

  • EMC: EN 55032 Class A, EN 61000-6-2, EN 61000-6-4

  • Shock and Vibration: EN 60068-2-27, EN 60068-2-64

  • Temperature and Humidity: EN 60068-2-1, EN 60068-2-2, EN
    60068-2-30

  • Ingress Protection: IP40

Product Usage Instructions

1. General Information

1.1. Legal Information

The contents of this document are provided as is. Except as
required by applicable law, no warranties of any kind are made in
relation to the accuracy and reliability or contents of this
document, either expressed or implied, including but not limited to
the implied warranties of merchantability and fitness for a
particular purpose. Westermo reserves the right to revise this
document or withdraw it at any time without prior notice.

Under no circumstances shall Westermo be responsible for any
loss of data or income or any special, incidental, and
consequential or indirect damages howsoever caused.

More information about Westermo can be found at www.westermo.com.

1.2. About This Guide

This guide is intended for installation engineers and users of
the Westermo products. It includes information on safety and
regulations, a product description, installation instructions, and
technical specifications.

1.3. Software Tools

Related software tools are available at https://www.westermo.com/support/productsupport.

1.4. License and Copyright for Included FLOSS

This product includes software developed by third parties,
including Free/Libre Open Source Software (FLOSS). The specific
license terms and copyright associated with the software are
included in each software package respectively. Please visit the
product web page for more information.

Upon request, the applicable source code will be provided. A
nominal fee may be charged to cover shipping and media. Please
direct any source code request to your normal sales or support
channel.

1.5. WeOS

This product runs WeOS 5 (Westermo Operating System).
Instructions for quick start, configuration, and factory reset are
found in the WeOS user documentation at www.westermo.com.

2. Safety and Regulations

2.1. Warning Levels

Warning signs are provided to prevent personal injuries and/or
damages to the product. The following levels are used:

Level of warning Description Consequence
WARNING Indicates a potentially hazardous situation Possible death or major

injury
CAUTION| Indicates a potentially hazardous situation| Minor or moderate injury
NOTICE| Provides information in order to avoid misuse of the product,
confusion or misunderstanding| No personal injury but minor damage to the product
NOTE| Used for highlighting general, important information| No personal injury but minor damage to the product

2.2. Safety Information

Before installation:

  1. Read this manual completely and gather all information
    available on the product. Make sure it is fully understood.

  2. Check that your application does not exceed the safe operating
    specifications for the product.

Frequently Asked Questions (FAQ)

Q: Where can I find more information about Westermo?

A: More information about Westermo can be found at www.westermo.com.

Q: Where can I find software tools related to this

product?

A: Related software tools are available at https://www.westermo.com/support/productsupport.

Q: How can I request the source code for the included

software?

A: Please direct any source code request to your normal sales or
support channel. A nominal fee may be charged to cover shipping and
media.

w w w. we s t e r m o. c o m
RedFox 5528 Series
Industrial routing switches
OS

Table of Contents
1. General Information ……………………………………………………………… 3 1.1. Legal Information …………………………………………………………. 3 1.2. About This Guide …………………………………………………………. 3 1.3. Software Tools ……………………………………………………………. 3 1.4. License and Copyright for Included FLOSS …………………………… 3 1.5. WeOS ……………………………………………………………………… 3
2. Safety and Regulations …………………………………………………………. 4 2.1. Warning Levels …………………………………………………………… 4 2.2. Safety Information ……………………………………………………….. 5 2.3. Care Recommendations ………………………………………………… 7 2.4. Product Disposal …………………………………………………………. 8 2.5. Compliance Information …………………………………………………. 8 2.5.1. Agency Approvals and Standards Compliance ……………….. 8 2.5.2. EN/IEC/UL 61010-2-201 Notice ………………………………… 8 2.5.3. EN/IEC/UL 62368-1 Notice ……………………………………… 9 2.5.4. UL 62368-1 DC Mains Notice …………………………………… 9 2.5.5. FCC Part 15.105 Class A Notice ……………………………….. 9 2.5.6. FCC Part 15.105 Class B Notice ……………………………… 10 2.5.7. Corrosive Environment …………………………………………. 10 2.5.8. Simplified Declaration of Conformity ………………………….. 10
3. Product Description ……………………………………………………………. 11 3.1. Product Description …………………………………………………….. 11 3.2. Available Models ……………………………………………………….. 12 3.3. Hardware Overview ……………………………………………………. 12 3.4. Connector Information …………………………………………………. 13 3.4.1. Power Input ……………………………………………………… 13 3.4.2. I/O Connection ………………………………………………….. 14 3.4.3. Console Port …………………………………………………….. 14 3.4.4. Micro SD …………………………………………………………. 14 3.4.5. SFP Transceivers ……………………………………………….. 15 3.5. LED Indicators ………………………………………………………….. 16 3.6. Dimensions ……………………………………………………………… 17
4. Installation ………………………………………………………………………. 18 4.1. Mounting ………………………………………………………………… 18 4.1.1. Rack Mounting ………………………………………………….. 18 4.1.2. Wall Mounting …………………………………………………… 18 4.2. Protective Earth Connection ………………………………………….. 18 4.3. Cooling …………………………………………………………………… 19
5. Specifications …………………………………………………………………… 20 5.1. Interface Specifications ………………………………………………… 20 5.2. Type Tests and Environmental Conditions …………………………… 24
6. Revision Notes …………………………………………………………………. 28

2

RedFox 5528 Series

1. General Information
1.1. Legal Information The contents of this document are provided “as is”. Except as required by applicable law, no warranties of any kind are made in relation to the accuracy and reliability or contents of this document, either expressed or implied, including but not limited to the implied warranties of merchantability and fitness for a particular purpose. Westermo reserves the right to revise this document or withdraw it at any time without prior notice.
Under no circumstances shall Westermo be responsible for any loss of data or income or any special, incidental, and consequential or indirect damages howsoever caused.
More information about Westermo can be found at www.westermo.com.
1.2. About This Guide This guide is intended for installation engineers and users of the Westermo products.
It includes information on safety and regulations, a product description, installation instructions and technical specifications.
1.3. Software Tools Related software tools are available at https://www.westermo.com/support/productsupport.
1.4. License and Copyright for Included FLOSS This product includes software developed by third parties, including Free/Libre Open Source Software (FLOSS). The specific license terms and copyright associated with the software are included in each software package respectively. Please visit the product web page for more information.
Upon request, the applicable source code will be provided. A nominal fee may be charged to cover shipping and media. Please direct any source code request to your normal sales or support channel.
1.5. WeOS This product runs WeOS 5 (Westermo Operating System). Instructions for quick start, configuration and factory reset are found in the WeOS user documentation at www.westermo.com.

RedFox 5528 Series

3

2. Safety and Regulations

2.1. Warning Levels Warning signs are provided to prevent personal injuries and/or damages to the product. The following levels are used:

Level of warning Description
Indicates a potentially hazardous situation

Consequence personal injury
Possible death or major injury

Consequence material damage
Major damage to the product

WARNING

Indicates a potentially hazardous situation

Minor or moderate injury

Moderate damage to the product

CAUTION

Provides information in order to avoid misuse of the product, confusion or misunderstanding

No personal injury

Minor damage to the product

NOTICE

Used for highlighting general, No personal injury but important information

Minor damage to the product

NOTE
Table 1. Warning levels

4

RedFox 5528 Series

2.2. Safety Information Before installation:
Read this manual completely and gather all information available on the product. Make sure it is fully understood. Check that your application does not exceed the safe operating specifications for the product.
SAFETY DURING INSTALLATION The product must be installed and operated by qualified service personnel and installed into an apparatus cabinet or similar, where access is restricted to service personnel only.
Refer to chapter Compliance Information to see the required level of qualified service personnel according to safety standards.
Before energising and connecting communication cables to the product, ensure a protective earthing conductor is first connected to the protective earthing terminal (only valid for metallic housings). Westermo recommends a cross- sectional area of at least 4 mm2.
Upon removal of the product, disconnect the product from the power supply and all other communication ports before disconnecting the protective earthing conductor.
HAZARDOUS VOLTAGE Do not open an energised product. Hazardous voltage may occur when connected to a power supply.
For RedFox models with a rated voltage above 48 VDC or 30 VAC: Apply the protective cap (delivered with the product) on the power cable.

RedFox 5528 Series

5

WARNING – PREVENT ACCESS TO HAZARDOUS VOLTAGE CABLE Apply the protective cap (delivered with the HV products) on the power cable, according to the illustrated steps below.

To prevent accidentally pulling out wires, make sure the power cable and the wires are firmly attached to the protective cap.

For screw connectors, make sure the screws are properly tightened, as well as routing the wires separately from other wires. For connectors with straps, fasten the cable as strain relief, as well as routing the wires separately.

1

2

3

PROTECTIVE FUSE It must be possible to disconnect manually from the power supply. Ensure compliance to national installation regulations. Replacing the internal fuse must only be performed by Westermo qualified personnel.
POWER SUPPLY CONNECTION There are safety regulations governing the power source that can be used in conjunction with the product. Refer to chapter Interface Specifications.
REDUCE THE RISK OF FIRE To reduce the risk of fire, use only telecommunication line cords with a cable diameter of AWG 26 or larger. Regarding power cable dimensions, see chapter Interface Specifications.

6

RedFox 5528 Series

CLASS 1 LASER PRODUCT Do not look directly into a fibre optical port or any connected fibre, although the product is designed to meet the Class 1 Laser regulations and complies with 21 CFR 1040.10 and 1040.11.

HANDLING OF SFP TRANSCEIVERS
SFP transceivers are supplied with plugs to avoid contamination inside the optical port. They are very sensitive to dust and dirt. If the fibre optic cable is disconnected from the product, a protective plug must be used on the transmitter/receiver. The protective plug must be kept on during transportation. The fibre optic cable must be handled the same way.

CORROSIVE GASES If the product is placed in a corrosive environment, it is important that all unused connector sockets are protected with a suitable plug, in order to avoid corrosion attacks on the gold plated connector pins.

ELECTROSTATIC DISCHARGE (ESD) Prevent electrostatic discharge damage to internal electronic parts by discharging your body to a grounding point (e.g. use a wrist strap).
2.3. Care Recommendations Follow the care recommendations below to maintain full operation of the product and to fulfill the warranty obligations:
· Do not drop, knock or shake the product. Rough handling above the specification may cause damage to internal circuit boards.
· Use a dry or slightly water-damp cloth to clean the product. Do not use harsh chemicals, cleaning solvents or strong detergents.
· Do not paint the product. Paint can clog the product and prevent proper operation.
If the product is used in a manner not according to specification, the protection provided by the equipment may be impaired.
If the product is not working properly, contact the place of purchase, the nearest Westermo distributor office or Westermo technical support.

RedFox 5528 Series

7

2.4. Product Disposal This symbol means that the product shall not be treated as unsorted municipal waste when disposing of it. It needs to be handed over to an applicable collection point for recycling electrical and electronic equipment.
By ensuring the product is disposed of correctly, you will help to reduce hazardous substances and prevent potential negative consequences to both the environment and human health, which could be caused by inappropriate disposal.

Figure 1. WEEE symbol for treatment of product disposal

2.5. Compliance Information 2.5.1. Agency Approvals and Standards Compliance

Type

Approval/Compliance

EMC

· EN 50121-4/IEC 62236-4, Railway signalling and telecommunications apparatus

· EN/IEC 61000-6-1, Immunity residential environmentsa.

· EN/IEC 61000-6-2, Immunity industrial environments · EN/IEC 61000-6-3, Emission residential environmentsa.

· EN/IEC 61000-6-4, Emission industrial environments

Safety

· EN/IEC/UL 62368-1, Safety Requirements for audio/video, information and communication technology equipmenta.
· EN/IEC/UL 61010-1, Safety requirements for electrical equipment for measurement, control, and laboratory use – Part 1: General requirementsb.
· EN/IEC/UL 61010-2-201, Safety requirements for electrical equipment for measurement, control, and laboratory use – Part 2-201: Particular requirementsb.

Marine

DNV GL rules for classification – Ships and offshore unitsa.

a.Valid for all RedFox-5528(-E)-LV models b.Valid for all RedFox-5528(-E)-HV models

Table 2. Agency approvals and standards compliance

2.5.2. EN/IEC/UL 61010-2-201 Notice1 This product has been tested and found compliant to EN/IEC/UL 61010-2-201, Safety requirements for electrical equipment for measurement, control, and laboratory use. In accordance with the definitions of the standard, this product shall be handled by skilled service personnel.
1Valid for all RedFox-5528(-E)-HV models

8

RedFox 5528 Series

2.5.3. EN/IEC/UL 62368-1 Notice2 This product has been tested and found compliant to EN/IEC/UL 62368-1, Safety for Communication Technology. In accordance with the definitions of the standard, this product shall be handled by instructed personnel. Energy source classifications are according to following:

Electrical energy source Power port ES1 (LV models)

Serial port ES1

Ethernet port ES1, TNV-1

I/O port

ES1

Power source

Power port PS3

Thermal energy source Enclosure

TS1

Mechanical energy source Enclosure

MS1 (MS3 for wall or ceiling mounting)

Radiation energy source SFP

RS1

Table 3. EN/IEC/UL 62368-1 notice

2.5.4. UL 62368-1 DC Mains Notice In accordance with UL 62368-1, Annex DVD and DVH then Westermo does not recommend using the mechanical enclosure/chassis (PE) as a conductive part of the sourced earthed DC power system in a DC mains distribution networks. If so, the transient protective barriers are compromised, and the product will not be compliant to evaluated standards and immunity performance according to type test table in the user guide.
The earthing electrodes shall be located at the source in the DC distribution system and separate earth and protective earth conductors shall be provided throughout the system.
The field wiring shall be sufficient fixated and the protective cap for the power connector, which is supplied with the product, shall be used on DC voltages higher than 60 VDC.
2.5.5. FCC Part 15.105 Class A Notice3 This product has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference when the product is operated in a commercial environment.
This product generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the user manual, may cause harmful interference to radio communications. Operation of this product in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at the users own expense.
2Valid for all RedFox-5528(-E)-LV models 3Valid for all RedFox-5528(-E)-HV models

RedFox 5528 Series

9

2.5.6. FCC Part 15.105 Class B Notice4 This product has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This product generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this product does cause harmful interference to radio or television reception, which can be determined by turning the product off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
· Reorient or relocate the receiving antenna · Increase the separation between the unit and receiver · Connect the product into an outlet on a circuit different from that to which the receiver
is connected · Consult the dealer or an experienced radio/TV technician for help
2.5.7. Corrosive Environment5 This product has been successfully tested in a corrosion test according to IEC 60068-2-60, method 3. This means that the product meets the requirements to be placed in an environment classified as ISA-S71.04 class G3.
CORROSIVE GASES If the product is placed in a corrosive environment, it is important that all unused connector sockets are protected with a suitable plug, in order to avoid corrosion attacks on the gold plated connector pins.
2.5.8. Simplified Declaration of Conformity Hereby, Westermo declares that this product is in compliance with applicable EU directives and UK legislations. The full declaration of conformity and other detailed information is available at www.westermo.com/support/product-support.

Figure 2. The European Conformity and the UK Conformity Assessment markings

4Valid for all RedFox-5528(-E)-LV models 5Valid for all RedFox-5528(-E)-LV models

10

RedFox 5528 Series

3. Product Description
3.1. Product Description The RedFox 5528 series is designed for the core of large high-performance industrial networks and has been developed to cater to the needs of current and future industrial data networks, combining outstanding performance, durability and reliability. These switches are ideal for handling the big data and high bandwidth requirements typically found within transportation, manufacturing, energy, smart cities and other applications.
Integrating hardware, software and network design support tools, this next generation switch platform offers advanced capabilities, the lowest total cost of ownership and will create the most reliable and resilient networks on the market.
The switch is engineered to maintain uninterrupted data communication, even in exceptionally harsh environments. The RedFox 5528 series is tested and certified to withstand extreme temperatures, vibrations and shocks. The switches only use industrial grade components which contributes towards a market leading mean time between failure (MTBF), maximized service life, and reduced operational and life cycle costs.
Various port configurations are available, all with full gigabit speed, that can be further customized with SFP transceivers. The RedFox 5528 series is available in either a DC or AC power supply as well as a configurable I/O fault contact making the switch ideal for monitoring in industrial applications.
The RedFox 5528 series is powered by the next generation WeOS operating system, which ensures robust operation and support for an expanding range of protocols and features. In addition, recognizing the growing sophistication of cyberattacks, an extensive suite of cyber security tools is available.
The switches are also prepared for routing acceleration, extended cybersecurity and time synchronization IEEE 1588v2 applications, making them an ideal solution to meet future security and bandwidth requirements.

RedFox 5528 Series

11

3.2. Available Models

Art. no.
3641-4500 3641-4400 3641-4508 3641-4408 3641-4510 3641-4410 3641-4518 3641-4418 3641-4520 3641-4420 3641-4528 3641-4428

Model
RedFox-5528-T28G-LV RedFox-5528-E-T28G-LV RedFox-5528-T28G-HV RedFox-5528-E -T28G-HV RedFox-5528-F4G-T24G-LV RedFox-5528-E-F4G-T24G-LV RedFox-5528-F4G- T24G-HV RedFox-5528-E-F4G-T24G-HV RedFox-5528-F16G-T12G-LV RedFox-5528-E-F16G- T12G-LV RedFox-5528-F16G-T12G-HV RedFox-5528-E-F16G-T12GHV

No. of copper ports 28
28
24
24
12
12

No. of SFP ports –

4
4
16
16

LV
24-48 VDC
24-48 VDC
24-48 VDC

HV
110-240 V AC/DC
110-240 V AC/DC
110-240 V AC/DC

3.3. Hardware Overview

1

2

3

4

56

7

NO C NC

Status

I/O Digital in
DI- DI+

12

ON

SD

CONSOLE AC/DC1 AC/DC2 FRNT RSTP/USR1 USR2

34

56

78

9 10

11 12

13 14

15 16

17 18

19 20

21 22

23 24

25 26

27 28

POWER 110-240 VAC / VDC

N (-)

L (+)

AC/DC 1

AC/DC 2

9

8

No.

Description

No.

Description

1

I/O connection

2

Console port

3

Micro SD

4

LED indicators

5

100/1000 Mbit/s SFP ports (number

depending on model)

6

10/100/1000 Mbit/s TX ports (number

depending on model)

7

Power Input

8

Protective earth

9

Label with data matrixa.

a.The base MAC address and production date of the product is included in the front label data matrix.

Figure 3. Location of interface ports and LED indicators, illustrated by a RedFox-5528-F16G-T12GHV

12

RedFox 5528 Series

3.4. Connector Information 3.4.1. Power Input

Illustration
COM +DC DC 1
DC 2

Product marking +DC1 +DC2 -COM -COM

Direction Input Input Input Input

Description Supply voltage Supply voltage
Common Common

Table 4. Power input LV models

Illustration

N (-)

L (+)

AC/DC 1

Position AC/DC1

Table 5. Power input HV models

Product marking
L(+)
N(-)

Direction Description

Input Input Input

Line/Phase (AC), positive (DC)
Neutral (AC), negative/return
(DC)
Functional earth

WARNING – PREVENT ACCESS TO HAZARDOUS VOLTAGE CABLE Apply the protective cap (delivered with the HV products) on the power cable, according to the illustrated steps below.

To prevent accidentally pulling out wires, make sure the power cable and the wires are firmly attached to the protective cap.

For screw connectors, make sure the screws are properly tightened, as well as routing the wires separately from other wires. For connectors with straps, fasten the cable as strain relief, as well as routing the wires separately.

1

2

3

RedFox 5528 Series

13

3.4.2. I/O Connection

Illustration

Position

NO C NC

Status

I/O
Digital in DI- DI+
Table 6. I/O connection

Digital in Status

Product marking
DI+ DIStatus NO Status C Status NC

Directio n
Input
Output

Description
Digital in+ Digital inAlarm (status) relay contact NO – Normally Open C – Common NC – Normally Closed

The Digital in is an opto-isolated digital input, which can be used to monitor external events.
The Status output is a potential free, opto-isolated, alternation (Form-C) solid-state relay. This can be configured to monitor various alarm events within the product, see WeOS user documentation at www.westermo.com. An external load in series with an external DC voltage source is required for proper functionality.

Unit condition Unpowered / pre-operational or Alarm active Operational and Alarm inactive
Table 7. Status output

Status NO- C OPEN
CLOSED

Status NC-C CLOSED OPEN

3.4.3. Console Port The console port can be used to connect to the CLI (Command Line Interface). The console connector is a USB cable that connects to a FTDI FT232R USB to serial converter internally. For drivers, refer to www.ftdichip.com and download the appropriate VCP driver.
3.4.4. Micro SD To insert the micro SD card correctly, turn the gold plated pins upwards.

Figure 4. Insertion of micro SD card

14

RedFox 5528 Series

3.4.5. SFP Transceivers The product supports UL and IEC certified transceivers only. See Westermo’s modular transceivers datasheets 100 Mbit and 1 Gbit for supported SFP transceivers, which can be downloaded from the product support pages at www.westermo.com/support/productsupport.
Each SFP slot can hold one SFP transceiver. See “Transceiver User Guide 6100-0000″ for transceiver handling instructions, which also can be downloaded from the product support pages at www.westermo.com/support/product-support.
In the event of contamination, the optical connectors in the SFP transceivers should only be cleaned by the use of forced nitrogen and some kind of cleaning stick. Recommended cleaning fluids are methyl-, ethyl-, isopropyl- or isobutyl alcohol, hexane or naphtha.
HANDLING OF SFP TRANSCEIVERS SFP transceivers are supplied with plugs to avoid contamination inside the optical port. They are very sensitive to dust and dirt. If the fibre optic cable is disconnected from the product, a protective plug must be used on the transmitter/receiver. The protective plug must be kept on during transportation. The fibre optic cable must be handled the same way.

RedFox 5528 Series

15

3.5. LED Indicators

LED ON
RSTP/ USR1
FRNT
DC1 / AC/DC1 DC2
USR2 TX/FX por ts

Status Description

OFF

Product has no power

GREEN All OK, no alarm condition

RED

Alarm condition, or until product has started

up. (Alarm conditions are configurable, see

WeOS5 User Guide)

OFF

RSTP disabled

GREEN RSTP enabled

BLINK

Product selected as RSTP/STP root switch

USR1

Configurable, see WeOS5 User Guide

OFF

FRNT disabled

GREEN FRNT OK

RED

FRNT error

FLASH

Product configured as FRNT focal point

OFF

Product has no power

GREEN Power OK on DC1 / AC/DC1

RED

Input voltage is below operating voltage limit

OFF

Product has no power

GREEN Power OK on DC2

RED

Input voltage is below operating voltage limit

Configurable, see WeOS5 User Guide

OFF

No link

GREEN Link established

GREEN FLASH

Data traffic indication

YELLOW Port alarm, or port is set in blocking state by link redundancy protocol

Table 8. LED indicators

16

RedFox 5528 Series

3 2

3.6. Dimensions Dimensions are stated in mm.
482,4 469 462
440 411

7,2 (x4)

4 3

240

235

1 8

466
Figure 5. Dimensional drawing

RedFox 5528 Series

17

4. Installation
4.1. Mounting RedFox is designed for installation in 19″ rack solutions according to ETSI standard, with a shallow depth of 240 millimetres. It can also be wall mounted as an installation option.
4.1.1. Rack Mounting The product can be mounted in all directions inside a 19″ apparatus cabinet. Use supplied M6x25 (Philips no. 3) or 1/4×1″ screws.

NO C NC

Status

I/O Digital in
DI- DI+

ON 12
SD

CONSOLE AC/DC1 FRNT RSTP/USR1 USR2

34

56

78

9 10

11 12

13 14

15 16

17 18

19 20

21 22

23 24

25 26

27 28

POWER N

110-240 (-)

VAC L (+)

/

VDC

AC/DC 1

Figure 6. Rack mounted product

4.1.2. Wall Mounting The product can be wall mounted in all directions. Use maximum 6.4 mm or 1/4″ screws.

NO C NC

Status

I/O Digital in
DI- DI+

ON 12
SD

CONSOLE AC/DC1 FRNT RSTP/USR1 USR2

34

56

78

9 10

11 12

13 14

15 16

17 18

19 20

21 22

23 24

25 26

27 28

POWER N

110-240 (-)

VAC L (+)

/

VDC

AC/DC 1

Figure 7. Wall mounted product

4.2. Protective Earth Connection For correct function, the earth connection needs to be properly connected to a designated PE rail. Torx: T25 and torque: 3.2 Nm.

NO C NC

Status

I/O Digital in
DI- DI+

12

ON

SD

CONSOLE AC/DC1 AC/DC2 FRNT RSTP/USR1 USR2

34

56

78

9 10

11 12

13 14

15 16

17 18

19 20

21 22

23 24

25 26

27 28

POWER 110-240 VAC / VDC

N (-)

L (+)

AC/DC 1

Figure 8. Earth connection

18

RedFox 5528 Series

4.3. Cooling This product relies on convection cooling. To avoid obstruction of the airflow around the product, follow the spacing recommendations.
For mounting in 19″ apparatus cabinet without forced ventilation, a minimal spacing of 1U according to IEC 60297 or 45 mm (1.75″) above/below is recommended. With forced ventilation, no minimal spacing is required as long as the temperature of the rear cooling plates does not exceed +85ºC (+185ºF).
For wall mounting in an area without forced ventilation, a minimum spacing of 45 mm (1.75″) above/below and 10 mm (0.4”) left/right is recommended. For areas with forced ventilation, no minimal spacing is required as long as the temperature of the rear cooling plates does not exceed +85ºC (+185ºF).

RedFox 5528 Series

19

5. Specifications

5.1. Interface Specifications

Power port Rated voltage Operating voltage Rated current
Fuse rating Component: U2 (LV), U43 (HV) Rated frequency Inrush current, I²ta.
Startup currentb. Polarity Redundant power input Isolation Connector Conductor cross section Stripping length cable

For LV models: 24-48 VDC For HV models: 110-240 V AC/DC

For LV models: 18-60 VDC For HV models: 85-264 VAC 47-63 Hz, 85-264 VDC

RedFox-5528-(E-)T28G-LV:

0.95 A at 24 VDC 0.49 A at 48 VDC

RedFox-5528-(E-)T28G-HV:

0.12 A at 240 V AC/DC 0.24 A at 110 V AC/DC

RedFox-5528-(E-)F4G-T24G-LV:

1.02 A at 24 VDC 0.51 A at 48 VDC

RedFox-5528-(E-)F4G-T24G-HV: 0.13 A at 240 V AC/DC 0.26 A at 110 V AC/DC

RedFox-5528-(E-)F16G-T12G-LV: 1.17 A at 24 VDC 0.59 A at 48 VDC

RedFox-5528-(E-)F16G-T12G-HV: 0.15 A at 240 V AC/DC 0.30 A at 110 V AC/DC

LV models: 4A(T), 125 VDC, breaking capacity 100 A, UL248-14 HV models: 4A(T), 350 VAC/VDC, breaking capacity 100 A, UL248-14

DC (LV models), DC, 50-60 Hz (HV models)

For all LV-models:

125 mA2s at 24 VDC 82 mA2s at 48 VDC

For all HV-models:

4 mA2s at 240 VAC, 50 Hz 0.4 mA2s at 110 VAC, 60 Hz 2 mA2s at 240 VDC 0.1 mA2s at 110 VDC

2x nominal current

Reverse polarity protected (LV models, not applicable for HV models)

Yes (LV models)

All other ports

Detachable screw terminal

0.5-1.5 mm² (AWG 20-16) Use copper conductors only.

7 mm

20

RedFox 5528 Series

Power port

Cable temperature rating

Minimum temperature rating of the cable to be connected to the field wiring terminals is +77 °C

Tightening torque, terminal screw

0.34 Nm

Tightening torque, screw flange

0.34 Nm

Shielded cable

Not required

a.Measured for 1 second at startup b.Recommended external supply current capability for proper startup

I/O connection, Digital input

Isolation to

All other ports

Connector

Detachable screw terminal

Conductor cross section

0.08 – 1.5 mm² (AWG 28-16). Use copper conductors only.

Stripping length cable

7 mm

Cable temperature rating

Minimum temperature rating of the cable to be connected to the field wiring terminals is +77 °C

Tightening torque, terminal screw

0.22 – 0.25 Nm

Terminal torque, screw flange 0.3 Nm

Circuit type

SELV

Maximum voltage/current Voltage levels

60 VDC, IIN 2.9 mA at 60 VDC
Logic one: >8 VDC Logic zero: <5 VDC

RedFox 5528 Series

21

I/O connection, Relay output

Connect resistance

Maximum 30

Isolation to

All other ports

Connector

Detachable screw terminal

Conductor cross section

0.08 – 1.5 mm² (AWG 28-16). Use copper conductors only.

Stripping length cable

7 mm

Cable temperature rating

Minimum temperature rating of the cable to be connected to the field wiring terminals is +77 °C

Tightening torque, terminal screw

0.22 – 0.25 Nm

Terminal torque, screw flange 0.3 Nm

Circuit type

SELV

Type of switch

Solid state, DC general use, DC Pilot duty

Maximum withstand across open contacts

60 VDC (continous)

Permissible current

80 mA (continous), 120 mA (short term 1 s.)

Ethernet TXa.

Electrical specification

IEEE std 802.3

Data rate

10 Mbit/s, 100 Mbit/s, 1000 Mbit/s, manual or auto

Duplex

Full or half, manual or auto

Circuit type

TNV-1

Transmission range

Up to 100 m with CAT5e cable or better

Isolation

All other ports

Cabling

Shielded cable CAT5e or better is recommended

Conductive chassis

Yes

a.10/100/1000 Mbit/s ports are: RedFox-5528-(E-)T28G-LV/HV: 1-28 RedFox-5528-(E-)F4G-24G-LV/HV: 5-28 RedFox-5528-(E-)F16G-T12G-LV/HV: 7-10, 15-18, 23-26

22

RedFox 5528 Series

SFP portsa.

Optical/Electrical specification Data rate Duplex

IEEE std 802.3 100 Mbit/s, 1000 Mbit/sb. Full or half, manual or auto

Transmission range

Depending on transceiver

Connector

SFP slot holding fibre transceiver

a.SFP ports are: RedFox-5528-(E-)F4G-T24G-LV/HV: 1-4 RedFox-5528-(E-)F16G- T12G-LV/HV: 1-6, 11-14, 19-22, 27-28

b.100 Mbit/s or 1000 Mbit/s tranceiver supported

Console port Electrical specification Data rate Circuit type Maximum supply current Connector

USB 2.0 device interface Up to 480 Mbps (high-speed mode) SELV 100 mA USB Micro B connector in device mode

Micro SD Electrical specification Circuit type Maximum supply current Connector

Secure Digital 2.0 SELV 100 mA Micro SD connector

RedFox 5528 Series

23

5.2. Type Tests and Environmental Conditions

Environmental phenomena ESD Fast transients
Surge 1.2/50 µs

Basic standard
EN 61000-4-2

Description Enclosure

EN 61000-4-4 EN 61000-4-5

Power port I/O ports Earth port Power port

Power frequency magnetic field
Voltage dips and interruptions

EN 61000-4-8

I/O port Ethernet ports Enclosure

EN 61000-4-11 AC power port

Pulsed magnetic field
Radiated RF immunity

EN 61000-4-9 EN 61000-4-3

Enclosure Enclosure

Conducted RF immunity

EN 61000-4-6

Radiated RF emission CISPR 16-2-3

Power port Ethernet ports I/O ports Earth port Enclosure

ANSI C63.4

Conducted RF emission

CISPR 16-2-1 Power port ANSI C63.4

Test levels
Contact: ±6 kV Air: ±8 kV ± 2 kV
LV models: L-E: ± 1 kV, 12 , 9 µF L-E: ± 2 kV, 42 , 0,5 µF L-L: ± 0,5 kV, 2 , 18 µF L-L: ± 1 kV, 42 , 0,5 µF HV models: L-E: ± 2 kV, 12 , 9 µF L-L: ± 1 kV, 2 , 18 µF L-E, L-L: ± 2 kV, 42 , 0.5 µF L-E: ± 2 kV, 2 direct on shield HV models: 100 A/m, cont. 1000 A/m, 3 s HV models: 0% UT, 1 cycle 0%,UT, 250/300 cycles at 50/60 Hz 40% UT,10/12 cycles at 50/60 Hz 300 A/m 20 V/m at (80 MHz to 2 GHz) 10 V/m at (2-6 GHz) 1 kHz sine, 80% AM 10 V, 80% AM, 1 kHz; (0.15-80) MHz
LV models: Class B HV models: Class A (30-6000 MHz) LV models: Class B HV models: Class A (FCC Part 15 B, 30 MHz -25.5 GHz) LV models: Class B HV models: Class A LV models: Class B HV models: Class A

24

RedFox 5528 Series

Environmental phenomena
Dielectric strength

Basic standard CISPR 22 EN/IEC/UL 62368-1
IEC 60255-27
IEEE 802.3

Description

Test levels

Ethernet ports
Power port to all other ports
I/O port to all other ports
Ethernet ports to all other ports
Power port (AC, DC) to all other por ts
I/O port to all other ports
Ethernet ports to all other ports

(FCC Part 15 B) LV models: Class B HV models: Class A LV models: 1500 VAC rms, 60 s
HV models: 2000 VAC rms, 60 s
1500 VAC rms, 60 s

Table 9. EMC and electrical conditions

RedFox 5528 Series

25

Environmental phenomena
Temperatures

Basic standard
EN 60068-2-1 EN 60068-2-2

Description Operational

Humidity
Corrosive gasesa. Altitude MTBF hours

EN 60068-2-30
IEC 60068-2-60
MIL-HDBK 217F

Storage and transpor t Operational Storage and transpor t Operating
Operational

Telcordia

Vibration

IEC 60068-2-6 (sine)
IEC 60068-2-64 (random)

Operational
Operational, endurance test

Shock
Enclosure
Weight Degree of protection Cooling Pollution degree

IEC 60068-2-27 EN/IEC/UL 62368-1
EN 60529
EN/IEC/UL 61010-1, EN 50124-1, EN/IEC/UL 62368-1

Operational Aluminium
Enclosure

Test levels
For LV models: -40 to +74°C (-40 to +165°F) For HV models: -40 to +70°C (-40 to +158°F) -50 to +85°C (-58 to +185°F)
5-95 % relative humidity
Method 3, 21 daysb.
2000 m/80 kPa RedFox-5528-(E-)F4G-T24G-LV: 371,000 RedFox-5528-(E-)F4G-T24G- HV: 316,000 RedFox-5528-(E-)F16G-T12G-LV: 386,000 RedFox-5528-(E-)F16G-T12G- HV: 353,000 RedFox-5528-(E-)T28G-LV: 356,000 RedFox-5528-(E-)T28G-HV: 303,000 RedFox-5528-(E-)F4G-T24G-LV: 643,000 RedFox-5528-(E-)F4G-T24G-HV: 678,000 RedFox-5528-(E-)F16G-T12G-LV: 706,000 RedFox-5528-(E-)F16G-T12G-HV: 710,000 RedFox-5528-(E-)(E-)T28G-LV: 620,000 RedFox-5528-(E-)T28G-HV: 653,000 2 g rms 5-500 Hz, 5 sweeps
12 dB/octave, 2-13.2 Hz, 0.011 g2/Hz, 13.2-100 Hz, 1.0 grms, 150 minutes per axis 5-2000 Hz, rms 2.3 m/s2 ,1.5h 30 g, 11 ms
Fire enclosure
3.8 kg IP40 Convection HV models: PD2 Macro and Micro Environment

26

RedFox 5528 Series

Environmental phenomena

Basic standard

Description

Test levels

Overvoltage category

EN/IEC/UL 61010-1, EN/IEC/UL 62368-1

HV models: OVC II

Insulation class

EN/IEC/UL 61010-1

HV models: Class I equipment

Location

Indoor use

a.For LV models only b.Method 3, 21 days corresponds to Harsh Industrial Environment G3 which is defined in ANSI/ISA 17.04: 2015

Table 10. Environmental and mechanical conditions

RedFox 5528 Series

27

6. Revision Notes

Revision Rev. M Rev. L Rev. K
Rev. J

Date 2023-10 2023-04 2022-10
2022-01

Rev. I Rev. H

2021-06 2020-11

Rev. G

2020-10

Rev. F

2019-11

Rev. E

2019-10

Rev. D

2019-06

Change description
3.2 Footnote “Selective sales approval” deleted
3.5 LED Indicators updated (ON; Blink deleted)
All MV model references in the user guide are deleted. 5.1 Interface Specifications updated (rated current updated
2.5.1 Agency Approvals and Standards Compliance updated (UL added to EN/IEC 61010-1, EN/IEC added to UL 61010-2-201), 2.5.2 EN/IEC/UL 61010-2-210 Notice added, 2.5.4 UL 62368-1 DC Mains Notice added, 5.2 Type Tests and Environmental Conditions (added UL to EN/IEC 61010-1, added EN/IEC/UL 62368-1)
2.5.1 Agency Approvals and Standards Compliance updated (EN/IEC/UL 60950-1 > 62368-1), 2.5.4 EN/IEC/UL 62368-1 Notice new chapter, 5.2 Type Test and Environmental Conditions table updated
2.2 Safety Information updated, 2.5.1 Agency Approvals and Standards Compliance, 3.4.1 Power input updated, 3.4.3 I/O Connection updated, 4.1.1 Rack Mounting, illustration updated, 4.1.2 Wall Mounting, illustration updated, 5.1 Interface Specifications updated (Power)
Westermo logo updated, illustrations throughout user guide updated with blue colour, 2.2 Safety information; warnings updated, 2.3 Care Recommendations; text updated, 2.5.1 Agency Approvals and Standards Compliance; table updated, 2.5.2 new chapter, 2.5.3 FCC Part 15.105 Class B Notice; footnote added, 2.5.4 Corrosive Environment; footnote added, 3.1 Product Description; text updated, 3.2 Available Models; table updated, 3.4.1 Power Input; table added, 3.4.2 I/O Connection; table added, note deleted, 3.4.4 new chapter, 3.4.5 SFP Transceivers; text updated, 3.5 LED Indicators; table updated, 4.1.1 Rack Mounting; text updated, 4.2 Earth Connection; text updated, 5.1 Interface Specifications; tables updated, 5.2 Type Tests and Environmental Conditions; tables updated
2.2 Safety Information and 2.3 Care Recommendations texts are updated to match the new revision of “General and Safety Information” (100-5001). old 2.4 Maintenance deleted, old 2.5 Fibre Optics Handling deleted, old 2.6 Cleaning Optical Connectors deleted (replaced with 3.4.4.1), 3.2 Available Models, table updated (name change HV to MV), 3.4.4 Warning added, 3.4.4.1 new chapter, 5.1 Interface Specifications table updated (name change HV to MV)
1.5 WeOS text updated, 3.2 Available Models table updated (name change HV to MV), 3.3 Hardware Overview Figure 3 text updated (name change HV to MV), 3.6 Dimensions text updated (name change HV to MV), 4.1 Mounting text updated, 5.1 Interface Specifications table updated (name change HV to MV), 5.2 Type Test and Environmental Conditions table updated (name change HV to MV)
Product name change throughout the user guide. USB port removed in illustrations and information. “Unit” changed to “product”.

28

RedFox 5528 Series

Revision

Date

Rev. C

2018-10

Rev. B

2017-11

Rev. A

2017-07

Change description
1.3 Software tools updated, 2.1 Warning levels updated (Caution), 2.2 Safety information updated, 2.3 Care recommendations updated, 2.5 Fibre optic handling updated, 2.7 Product disposal updated, 2.8.1 Agency approvals and standard compliance updated, 2.8.4 Simplified declaration of conformity updated, 3.1 Product description updated, 3.2 Available models updated, 3.3 Hardware overview updated, 3.4.1 Power input and I/O updated, 3.5 LED indicators updated, 3.6 Dimensions updated, 5.1 Interface specifications updated, 5.2 Type test and environmental conditions updated
2.2 New warning added, 2.7 Environmental protection updated to Product disposal, 2.8.1 Agency approvals updated, 2.8.3 Corrosive gases upgraded to Caution instead of Notice, 2.8.4 DoC updated, 3.1 Text updated, 3.4.1 Warning updated with illustrations, 3.4.4 Figure 3 deleted (old), 5.1 Fuse rating updated
2.2 Safety information; Caution – Class 1 laser product updated, 2.3 Care Recommendations updated, 2.8.3 new chapter added, 3.3 text added, 5.1 Interface Specifications updated – inrush current, SFP ports, 5.2 Type Tests and Environmental Conditions updated – Surge updated, Corrosive gased added, Vibration updated, Radiated RF emission and Conducted RF emission updated
First issue of the user guide

RedFox 5528 Series

29

Westermo · Metallverksgatan 6, SE-721 30 Västerås, Sweden Tel +46 16 42 80 00 Fax +46 16 42 80 01 E-mail: info@westermo.com www.westermo.com
6641-22820 REV M 2023 10 @ Westermo Network Technologies AB, Sweden

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

westermo User Manuals

Related Manuals