General Information
1.1. Legal Information
The contents of this document are provided “as is”. Except as required by
applicable law, no warranties of any kind are made in relation to the accuracy
and reliability or contents of this document, either expressed or implied,
including but not limited to the implied warranties of merchantability and
fitness for a particular purpose. Westeros reserves the right to revise this
document or withdraw it at any time without prior notice.
Under no circumstances shall Westeros be responsible for any loss of data or
income or any special, incidental, and consequential or indirect damages
howsoever caused.
More information about Westeros can be found at
www.westermo.com
1.2. About This Guide
This guide is intended for installation engineers and users of the Westeros
products.
It includes information on safety and regulations, a product description,
installation instructions and technical specifications.
1.3. Software Tools
Related software tools are available at
https://www.westermo.com/support/productsupport.
1.4. License and Copyright for Included FLOSS
This product includes software developed by third parties, including
Free/Libre Open Source Software (FLOSS). The specific license terms and
copyright associated with the software are included in each software package
respectively. Please visit the product web page for more information.
Upon request, the applicable source code will be provided. A nominal fee may
be charged to cover shipping and media. Please direct any source code request
to your normal sales or support channel.
1.5. Woe’s
This product runs Woe’s 5 (Westeros Operating System). Instructions for quick
start, configuration and factory reset are found in the Woe’s user
documentation at www.westermo.com.
Safety and Regulations
2.1. Warning Levels
Warning signs are provided to prevent personal injuries and/or damages to the
product. The following levels are used:
Level of warning| Description| Consequence personal injury|
Consequence material damage
---|---|---|---
WARNING
| Indicates a potentially hazardous situation| Possible death or major injury| Major damage to the product
CAUTION
| Indicates a potentially hazardous situation| Minor or moderate injury| Moderate damage to the product
NOTICE
| Provides information in order to avoid misuse of the product, confusion or misunderstanding| No personal injury| Minor damage to the product
NOTE
| Used for highlighting general, but important information| No personal injury| Minor damage to the product
able 1. Warning levels
2.2. Safety Information
Before installation:
Read this manual completely and gather all information available on the
product. Make sure it is fully understood. Check that your application does
not exceed the safe operating specifications for the product.
SAFETY DURING INSTALLATION
The product must be installed and operated by qualified service personnel and
installed into an apparatus cabinet or similar, where access is restricted to
service personnel only.
Refer to chapter Compliance Information to see the required level of qualified
service personnel according to safety standards.
Before energizing and connecting communication cables to the product, ensure a
protective earthing conductor is first connected to the protective earthing
terminal (only valid for metallic housings). Westeros recommends a cross-
sectional area of at least 4 mm
Upon removal of the product, disconnect the product from the power supply and
all other communication ports before disconnecting the protective earthing
conductor.
HAZARDOUS VOLTAGE
Do not open an energized product. Hazardous voltage may occur when connected
to a power supply.
PROTECTIVE FUSE
The power supply wiring must be sufficiently fused.
It must be possible to disconnect manually from the power supply. Ensure
compliance to national installation regulations.
POWER SUPPLY CONNECTION
There are safety regulations governing the power source that can be used in
conjunction with the product. Refer to chapter Interface Specifications.
REDUCE THE RISK OF FIRE
To reduce the risk of fire, use only telecommunication line cords with a cable
diameter of AWG 26 or larger. Regarding power cable dimensions, see chapter
Interface Specifications.
CLASS 1 LASER PRODUCT
Do not look directly into a fiber optical port or any connected fiber,
although the product is designed to meet the Class 1 Laser regulations and
complies with 21 CFR 1040.10 and 1040.11.
HANDLING OF SFP TRANSCEIVERS SFP
transceivers are supplied with plugs to avoid contamination inside the optical
port. They are very sensitive to dust and dirt. If the fiber optic cable is
disconnected from the product, a protective plug must be used on the
transmitter/receiver. The protective plug must be kept on during
transportation. The fiber optic cable must be handled the same way.
CORROSIVE GASES
If the product is placed in a corrosive environment, it is important that all
unused connector sockets are protected with a suitable plug, in order to avoid
corrosion attacks on the gold plated connector pins.
ELECTROSTATIC DISCHARGE (ESD )
Prevent electrostatic discharge damage to internal electronic parts by
discharging your body to a grounding point (e.g. use a wrist strap).
2.3. Care Recommendations
Follow the care recommendations below to maintain full operation of the
product and to fulfill the warranty obligations:
- Do not drop, knock or shake the product. Rough handling above the specification may cause damage to internal circuit boards.
- Use a dry or slightly water-damp cloth to clean the product. Do not use harsh chemicals, cleaning solvents or strong detergents.
- Do not paint the product. Paint can clog the product and prevent proper operation.
If the product is used in a manner not according to specification, the
protection provided by the equipment may be impaired.
If the product is not working properly, contact the place of purchase, the
nearest Westeros distributor office or Westeros technical support.
2.4. Product Disposal
This symbol means that the product shall not be treated as unsorted municipal
waste when disposing of it. It needs to be handed over to an applicable
collection point for recycling electrical and electronic equipment.
By ensuring the product is disposed of correctly, you will help to reduce
hazardous substances and prevent potential negative consequences to both the
environment and human health, which could be caused by inappropriate disposal.
Figure 1. WEEE symbol for treatment of product disposal
2.5. Compliance Information
2.5.1. Agency Approvals and Standards Compliance
Type | Approval/Compliance |
---|---|
EMC | • EN/IEC 61000-6-2, Immunity industrial environments |
• EN/IEC 61000-6-4, Emission industrial environments
• FCC Part 15.105 class A
Trackside| • EN 50121-4/IEC 62236-4, Railway signaling and telecommunications
apparatus
Safety| • EN/IEC/UL 62368-1, Safety Requirements for audio/video, information
and communication technology equipment
2.5.2. FCC Part 15.105 Class A Notice
This product has been tested and found to comply with the limits for a Class A
digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful
interference when the product is operated in a commercial environment.
This product generates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the user manual, may cause harmful
interference to radio communications. Operation of this product in a
residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at the users own expense.
2.5.3. EN/IEC/UL 62368-1 Notice
This product has been tested and found compliant to EN/IEC/UL 62368-1, Safety
for Communication Technology. In accordance with the definitions of the
standard, this product shall be handled by instructed personnel. Energy source
classifications are according to following:
2.5.4. Corrosive Environment
This product has been successfully tested in a corrosion test according to IEC
60068-2-60, method 3. This means that the product meets the requirements to be
placed in an environment classified as ISA-S71.04 class G3.
CORROSIVE GASES
If the product is placed in a corrosive environment, it is important that all
unused connector sockets are protected with a suitable plug, in order to avoid
corrosion attacks on the gold plated connector pins.
2.5.5. Simplified Declaration of Conformity
Hereby, Westeros declares that this product is in compliance with applicable
EU directives and UK legislations. The full declaration of conformity and
other detailed information is available at www.westermo.com/support/product-
support.
****Figure 2. The European Conformity and the UK Conformity Assessment
markings
Product Description
3.1. Product Description The RedFox-7528 Industrial Ethernet switch is
designed to be a workhorse, providing performance and robustness today and for
years to come. In today’s world, many applications combine data, voice, and
video, and as a result, high performance and reliability are required. The
RedFox-7528 high performance industrial Ethernet switches provide an ideal
solution for these large-scale industrial networks.
RedFox-7528 is designed for 19” cabinets according to the ETSI standard, which
makes it suitable for use in control room networks as well as for cabinets
installed along railway trackside installations. In addition to the ultra-
rugged IP40 finless all metal housing, it is equipped with configurable I/O
fault contacts, which makes it ideal for easy installation and monitoring in
industrial applications.
To ensure long service life and market leading MTBF, only industrial grade
components are used. In addition, the switches can withstand constant
vibration, extreme temperatures and demanding electrical environments.
RedFox-7528 has been tested both by Westeros and external test labs to meet
many standards regarding EMC, isolation, vibration and shock, all to the
highest levels suitable for heavy industrial environments and rail trackside
applications.
Powered by Woe’s, the Westeros network operating system, the switches are
flexible, feature-rich as well as easy to install and configure. Woe’s has
been developed to allow cross-platform and future-proof solutions and can
deliver resilient and flexible networks, e.g. the FRNT ring protocol with
very fast failover.
Ensuring the security of industrial data communication networks is of
paramount importance, especially with the nature of cyberattacks becoming
increasingly sophisticated. To reduce risk and increase cyberresilience,
RedFox-7528 has an extensive suite of advanced cybersecurity features. These
can be used to build networks in compliance with the IEC 62443 standard, which
defines technical security requirements for data communication network
components.
3.2. Available Models
Art. no.| Model| No. of copper ports| No. of SFP ports|
No. of SFP+ ports| Layer
---|---|---|---|---|---
3641-4540| RedFox-7528-F4G10F12G-T12G-LV| 12| 12| 4| Layer 2
3.3. Hardware Overview
No. | Description | No. | Description |
---|---|---|---|
1 | I/O connection | 2 | Console port |
3 | Micro SD | 4 | LED indicators |
5 | 100/1000 Mbit/s SFP ports | 6 | 10/100/1000 Mbit/s TX ports |
7 | Power input | 8 | Protective earth |
9 | SFP+ ports | 10 | Label with data matrix. |
a. The base MAC address and production date of the product is included in the
front label data matrix.
Figure 3. Location of interface ports and LED indicators
3.4. Connector Information
3.4.1. Power Input
Illustration | Product marking | Direction | Description |
---|---|---|---|
+DC1 | Input | Supply voltage | |
+DC2 | Input | Supply voltage | |
-COM | Input | Common | |
-COM | Input | Common |
Table 2. Power input LV models
3.4.2. I/O Connection
Illustration| Position| Product marking| Direction **|
Description**
---|---|---|---|---
| Digital in| DI+| Input| Digital in+
DI-| Digital in-
Status| Status NO| Output| Alarm (status) relay contact NO – Normally Open
C – Common
NC – Normally Closed
Status C
Status NC
Table 3. I/O connection
The Digital in is an opto-isolated digital input, which can be used to monitor
external events.
The Status output is a potential free, opto-isolated, alternation (Form-C)
solid-state relay.
This can be configured to monitor various alarm events within the product, see
Woe’s Management Guide. An external load in series with an external DC voltage
source is required for proper functionality.
Unit condition | Status NO- C | Status NC-C |
---|---|---|
Unpowered / pre-operational or Alarm active | OPEN | CLOSED |
Operational and Alarm inactive | CLOSED | OPEN |
Table 4. Status output
3.4.3. Console Port
The console port can be used to connect to the CLI (Command Line Interface).
The console connector is a USB cable that connects to a FTDI FT232R USB to
serial converter internally. For drivers, refer to
www.ftdichip.com and download the appropriate VCP
driver.
3.4.4. Micro SD
To insert the micro SD card correctly, turn the gold plated pins upwards.
Figure 4. Insertion of micro SD card
3.4.5. SFP Transceivers
The product supports UL and IEC certified transceivers only. See Westeros’s
modular transceivers datasheets for supported SFP and SFP+ transceivers, which
can be downloaded from the product support pages at
www.westermo.com/support/productsupport.
Each SFP slot can hold one SFP transceiver. See “Transceiver User Guide
6100-0000” for transceiver handling instructions, which also can be downloaded
from the product support pages at
www.westermo.com/support/product-support.
In the event of contamination, the optical connectors in the SFP transceivers
should only be cleaned by the use of forced nitrogen and some kind of cleaning
stick. Recommended cleaning fluids are methyl-, ethyl-, isopropyl- or isobutyl
alcohol, hexane or naphtha.
HANDLING OF SFP TRANSCEIVERS
SFP transceivers are supplied with plugs to avoid contamination inside the
optical port. They are very sensitive to dust and dirt. If the fiber optic
cable is disconnected from the product, a protective plug must be used on the
transmitter/receiver. The protective plug must be kept on during
transportation. The fiber optic cable must be handled the same way.
3.5. LED Indicators
LED | Status | Description |
---|---|---|
ON | OFF | Product has no power |
GREEN | All OK, no alarm condition | |
RED | Alarm condition, or until product has started up. (Alarm conditions are |
configurable, see WeOS5 User Guide )
RSTP/ USR1| OFF| RSTP disabled
GREEN| RSTP enabled
BLINK| Product selected as RSTP/STP root switch
USR1| Configurable, see WeOS5 User Guide
FRNT| OFF| FRNT disabled
GREEN| FRNT OK
RED| FRNT error
FLASH| Product configured as FRNT focal point
DC1| OFF| Product has no power
GREEN| Power OK on DC1
RED| Input voltage is below operating voltage limit
DC2| OFF| Product has no power
GREEN| Power OK on DC2
RED| Input voltage is below operating voltage limit
USR2| Configurable, see WeOS5 User Guide
TX/FX ports| OFF| No link
GREEN| Link established
GREEN FLASH| Data traffic indication
YELLOW| Port alarm and no link. Or if FRNT or RSTP mode, port is blocked.
Table 5. LED indicators
3.6. Dimensions
Dimensions are stated in mm.
Figure 5. Dimensional drawing, illustrated by a RedFox-7528-F4G10-F12G-T12G-LV
Mounting
Redox is designed for installation in 19″ rack solutions according to ETSI
standard, with a shallow depth of 240 millimeters. It can also be wall mounted
as an installation option.
4.1. Rack Mounting
The product can be mounted in all directions inside a 19″ apparatus cabinet.
Use supplied M6x25 (Philips no. 3) or 1/4×1″ screws.
Figure 6. Rack mounted product
4.2. Wall Mounting
The product can be wall mounted in all directions. Use maximum 6.4 mm or 1/4″
screws.
Figure 7. Wall mounted product
4.3. Protective Earth Connection
For correct function, the earth connection needs to be properly connected to a
designated PE rail. Torn: T25 and torque: 3.2 Nm.
Figure 8. Earth connection
4.4. Cooling
This product relies on convection cooling. To avoid obstruction of the airflow
around the product, follow the spacing recommendations.
For mounting in 19″ apparatus cabinet without forced ventilation, a minimal
spacing of 1U according to IEC 60297 or 45 mm (1.75″) above/below is
recommended.
For wall mounting in an area without forced ventilation, a minimum spacing of
45 mm (1.75″) above/below and 10 mm (0.4″) left/right is recommended.
Specifications
5.1. Interface Specifications
Power port
Rated voltage| 24-48 VDC
Operating voltage| 18-60 VDC
Rated current| RedFox-7528-F4G10-F12G-T12G-LV| 1.39 A at 24 VDC 0.68 A
at 48 VDC
Fuse rating Component: U2| 4A(T), 125 VDC, breaking capacity 100 A,
UL248-14
Rated frequency| DC
Inrush current, I²t a.| 75 mA2s at 24 VDC 365 mA2s at 48 VDC
Startup current| 2x nominal current
Polarity| Reverse polarity protected
Redundant power input| Yes
Isolation| All other ports
Connector| Detachable screw terminal
Conductor cross section| 0.5-1.5 mm² (AWG 20-16) Use copper conductors
only.
Stripping length cable| 7 mm
Cable temperature rating| Minimum temperature rating of the cable to be
connected to the field wiring terminals is +77 °C
Tightening torque, terminal screw| 0.34 Nm
Tightening torque, screw flange| 0.34 Nm
Shielded cable| Not required
a. Measured for 1 second at startup
I/O connection, Digital input
Isolation to| All other ports
Connector| Detachable screw terminal
Conductor cross section| 0.08 – 1.5 mm² (AWG 28-16). Use copper
conductors only.
Stripping length cable| 7 mm
Cable temperature rating| Minimum temperature rating of the cable to be
connected to the field wiring terminals is +77 °C
Tightening torque, terminal screw| 0.22 – 0.25 Nm
Terminal torque, screw flange| 0.3 Nm
Circuit type| SELV
Maximum voltage/current| 60 VDC, IIN ≤ 2.9 mA at 60 VDC
Voltage levels| Logic one: >8 VDC Logic zero: <5 VDC
I/O connection, Relay output
Connect resistance| Maximum 30 Ω
Isolation to| All other ports
Connector| Detachable screw terminal
Conductor cross section| 0.08 – 1.5 mm² (AWG 28-16). Use copper
conductors only.
Stripping length cable| 7 mm
Cable temperature rating| Minimum temperature rating of the cable to be
connected to the field wiring terminals is +77 °C
Tightening torque, terminal screw| 0.22 – 0.25 Nm
Terminal torque, screw flange| 0.3 Nm
Circuit type| SELV
Type of switch| Solid state, DC general use, DC Pilot duty
Maximum withstand across open contacts| 60 VDC (continuous)
Permissible current| 80 mA (continuous), 120 mA (short term 1 s.)
Ethernet TX a.
Electrical specification| IEEE sty 802.3
Data rate| 10 Mbit/s, 100 Mbit/s, 1000 Mbit/s, manual or auto
Duplex| Full or half, manual or auto
Circuit type| TNV-1
Transmission range| Up to 100 m with CAT5e cable or better
Isolation| All other ports
Cabling| Shielded cable CAT5e or better is recommended
Conductive chassis| Yes
a.10/100/1000 Mbit/s ports are: 7-10, 15-18, 23-26
SFP ports.
Optical/Electrical specification| IEEE sty 802.3
Data rate| 100 Mbit/s, 1000 Mbit/sb.
Duplex| Full or half, manual or auto
Transmission range| Depending on transceiver
Connector| SFP slot holding fiber transceiver
a. SFP ports are: 5-6, 11-14, 19-22, 27-28
b.100 Mbit/s or 1000 Mbit/s transceiver supported
SFP+ ports.
Optical/Electrical specification| IEEE sty 802.3
Data rate| 1000 Mbit/s, 10 Grit/sb.
Duplex| Full or half, manual or auto
Transmission range| Depending on transceiver
Connector| SFP+ slot holding fiber transceiver
a. SFP+ ports are: 1-4
b.1000 Mbit/s or 10 Grit/s transceiver supported
Console port
Electrical specification| USB 2.0 device interface
Data rate| Up to 480 MPs (high-speed mode)
Circuit type| SELV
Maximum supply current| 100 mA
Connector| USB Micro B connector in device mode
Micro SD
Electrical specification| Secure Digital 2.0
Circuit type| SELV
Maximum supply current| 100 mA
Connector| Micro SD connector
5.1. Type Tests and Environmental Conditions
Environmental phenomena| Basic standard| Description| Test
levels
---|---|---|---
ESD| EN 61000-4-2| Enclosure| Contact: ±6 kV Air: ±8 kV
Fast transients| EN 61000-4-4| Power port I/O ports Earth port| ± 2 kV,
5 kHz, 100 kHz
Surge 1.2/50 µs| EN 61000-4-5| Power port| L-E: ± 1 kV, 12 Ω, 9 µF
L-E: ± 2 kV, 42 Ω, 0,5 µF
L-L: ± 0,5 kV, 2 Ω, 18 µF
L-L: ± 1 kV, 42 Ω, 0,5 µF
I/O ports| L-E: ± 2 kV, 42 Ω, 0.5 µF
L-L: ± 1 kV, 42 Ω, 0.5 µF
Ethernet ports| L-E: ± 2 kV, 2 Ω direct on shield
Power frequency magnetic field| EN 61000-4-8| Enclosure| 100 A/m,
16.7, 50 and 60 Hz 300 A/m DC
Pulsed magnetic field| EN 61000-4-9| Enclosure| 300 A/m
Radiated RF immunity| EN 61000-4-3| Enclosure| 20 V/m at (80 MHz to
2.7 GHz)
10 V/m at (2.7 to 6 GHz)
Conducted RF immunity| EN 61000-4-6| Power port Ethernet ports
I/O ports Earth port| 10 V, 80% AM, 1 kHz; (0.15-80) MHz
Radiated RF emission| CISPR 16-2-3| Enclosure| Class A, (30-6000 MHz)
ANSI C63.4| Class A
(FCC Part 15 B, 30 MHz to 26 GHz)
Conducted RF emission| CISPR 16-2-1| Power port| Class A
ANSI C63.4| Class A, (FCC Part 15 B)
CISPR 22| Ethernet ports| Class A
Dielectric strength| EN/IEC/UL 62368-1| Power-, I/O- and Ethernet-ports
to all other ports, incl. chassis| 1500 VAC rams, 60 s
IEEE 802.3| Ethernet-ports to all other ports, incl. chassis| 1500 VAC rams,
60 s
Table 6. EMC and electrical conditions
Environmental phenomena| Basic standard| Description| Test
levels
---|---|---|---
Temperatures| EN 60068-2-1
EN 60068-2-2| Operational| -40 to +70 °C (-40 to +158 °F)a.
Storage and transport| -40 to +85°C (-40 to +185°F)
Humidity| EN 60068-2-30| Damp heat, cyclic| +25 to 55°C, 95% RH 2 cycles
(12+12 hours) = 48 hours
Corrosive gases| IEC 60068-2-60| Operating| Method 3, 21 days.
Altitude| | Operational| 2000 m/80 kPa
MTBF hours| MIL-HDBK 217F| | 371,000 hours
Telcordia| | 763,000 hours
Vibration| IEC 60068-2-6 (sine)| Operational| 5 – 8 Hz: ±7.5 mm
8 – 500 Hz: 2 g
5 sweeps per axis
IEC 60068-2-64 (random)| Operational, endurance test| 5 – 2000 Hz, 2.3 m/s2
rams 90 minutes per axis
Shock| IEC 60068-2-27| Operational| 15 g, 11 mms
Enclosure| EN/IEC/UL 62368-1| Aluminum| Fire enclosure
Weight| | | 3.8 kg
Degree of protection| EN 60529| Enclosure| IP40
Cooling| | | Convection
Location| | | Indoor use
a. Depending on SFP+ transceiver types, contact Westeros for more information.
b. Method 3, 21 days corresponds to Harsh Industrial Environment G3 which is
defined in ANSI/ISA 17.04: 2015
Table 7. Environmental and mechanical conditions
Revision Notes
Revision | Date | Change description |
---|---|---|
Rev. C | 2023-04 | 3.5 LED Indicators updated (ON; Blink deleted) |
Rev. B | 2022-06 | 2.5.1 Agency Approvals and Standards Compliance; “pending” |
removed from EN/IEC/UL 62368-1, 2.5.3 EN/IEC/UL 62368-1 Notice; pending
removed, 5.2 Type Tests and Environmental Conditions; test level for
operational temperatures updated
Rev. A| 2022-05| First version of the user guide
Westeros • Metallverksgatan 6, SE-721 30 Vasteras, Sweden
Tel +46 16 42 80 00 Fax +46 16 42 80 01
E-mail: info@westermo.com
www.westermo.com
6641-26001 REV C 2023 04 @ Westeros
Network Technologies AB, Sweden
References
- Westermo ᐅ Robust and Secure Industrial Networking Solutions
- Product support, user guides and software downloads ᐅ Westermo
- Product support, user guides and software downloads ᐅ Westermo
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>