Bright 024673 Smart Smoke Detector with Heat Sensor Instruction Manual

June 13, 2024
Bright

Bright 024673 Smart Smoke Detector with Heat Sensor

Bright-024673-Smart-Smoke-Detector-with-Heat-Sensor-
product

Product Information

  • Product Name: Smart Smoke Detector with Heat Sensor
  • Model Number: GS558HD-H04
  • Manufacturer: Jula AB
  • Country of Origin: Sweden
  • Power Source: 2 AA batteries (1.5 VDC)
  • Sound Level: >85 dB at 3 meters
  • Frequency: 2.4 GHz
  • Range: >30 meters
  • Compliance: Directive/Regulation CPR 305/2011, Construction Products Regulation, RED 2014/53/EU, RoHS 2011/65/EU + 2015/863, Harmonised standard EN 14604:2005/AC:2008, EN 301 489-1 V2.2.3, EN 301 489-17 V3.2.4, EN 300 328 V2.2.2, EN IEC 62311:2020, EN 50581:2012

Product Usage Instructions

Mounting:

  • Identify a suitable location on the ceiling for mounting the smoke detector.
  • Insert two AA batteries into the battery compartment of the smoke detector.
  • Ensure the smoke detector and its radio communication are functioning properly.
  • Hold the mounting bracket against the chosen location on the ceiling and mark the screw holes with a pen.
  • Align the mounting bracket with the marked screw holes and secure it using two 3×25 mm screws.
  • Verify that the smoke detector is securely mounted.

Battery Replacement:

  • Hold the smoke detector housing and twist it counterclockwise to remove it from the mounting bracket.
  • Replace the old batteries with two new AA batteries, ensuring correct polarity.
  • Reattach the smoke detector housing to the mounting bracket by twisting it clockwise.

Testing:

  • Press and hold the test button on the smoke detector for at least 5 seconds.
  • Verify that the alarm sound is activated during the test.

Troubleshooting:
If the alarm sound does not activate during testing, refer to the user manual for further instructions.
Note: Always follow the safety instructions provided in the user manual. Dispose of the product according to applicable regulations.

Jula AB reserves the right to make changes to the product. Jula AB claims copyright on this documentation. It is not allowed to modify or alter this documentation in any way and the manual shall be printed and used as it is in relation to the product. For the latest version of operating instructions, refer to the Jula website.
WWW.JULA.COM
© JULA AB 2023-05-05
JULA AB
BOX 363, 532 24 SKARA, SWEDEN

EU DECLARATION OF CONFORMITY

  • Item number 024673
  • Model no.: GS558HD-H04

This declaration of conformity is issued under the sole responsibility of the manufacturer.

SMOKE ALARM
Conforms to the following directives, regulations and standards:

Directive/Regulatio n Harmonized   standar d
CPR 305/2011 Construction Products Regulation EN 14604:2005/AC:2008
RED 2014/53/EU EN 301 489-1 V2.2.3, EN 301 489-17 V3.2.4, EN 300 328 V2.2.2,

EN IEC 62311:2020
RoHS 2011/65/EU + 2015/863| EN 50581:2012

This product was CE marked in year: Signed for and on behalf of

Skara 2022-11-09 FREDRIK BOHMAN BUSINESS AREA MANAGER

SAFETY INSTRUCTIONS

Read these instructions carefully before use, and save them for future reference.

  • No replaceable components. Only the batteries are replaceable. Do not dismantle the product or attempt to repair it.
  • The alarm function must only be tested with the test button on the product. Do not use any other test method.
  • Do not remove the batteries – the product will not provide protection. If the product sets off an alarm and it is quite certain that it is a false alarm (no smoke or fire), open a window and/or fan the air around the product to stop the alarm.
  • Follow all the local electrical installation and building regulations.
  • The product is intended for a one-family house. In an apartment block each separate apartment must be supplied with its own smoke detector/fire alarm. The product must not be installed in buildings other than private residences. The product cannot replace a complete alarm system.
  • The alarm signal is loud, so that it will be easily noticed. Nevertheless there are several circumstances that can prevent the alarm signal from being detected, for example strong background noise, deep sleep, diminished hearing, or the influence of alcohol or drugs. If a person in the household has diminished hearing a special alarm with light and/or vibration signals should be installed. To provide effective protection from personal injury or death, a smoke detector must be heard very quickly.
  • Smoke detectors only set off an alarm when they detect smoke or combustion particles in the air. They do not detect naked flames or gas. In many cases a fire develops very quickly – a lot of flammable or explosive material, arson or negligence can accelerate the fire. In such circumstances it is not certain that the alarm in  the product will be triggered quickly enough for those in the building to reach a safe place.
  • Smoke detectors are not guaranteed to be functionally reliable and they can only alarm – they do not protect persons or property from fire. Smoke detectors cannot replace insurance. Home owners and tenants should have life and personal accident insurance, home and property insurance.
  • Every alarm can be affected by faults, and malfunction. For this reason test this product every week and replace every 10 years.

SYMBOLS

| Read the instructions.
---|---
| Approved in accordance with the relevant directives.
| Recycle discarded product in accordance with local regulations.

TECHNICAL DATA

  • Rated voltage 1.5 VDC
  • Power supply 2 AA batteries
  • Power consumption < 6 μA (standby) < 1200 mA (alarm)
  • Sound level for alarm > 85 dB / 3 m
  • Temperature sensitivity 54–70°C
  • Smoke sensitivity 0.108–0.141 dB/m
  • Frequency 2.4 GHz
  • Radio communication power consumption < 450mA
  • Range > 30 m

DESCRIPTION

The fire alarm is a photoelectric smoke detector. The photoelectric technology makes the smoke detector more sensitive to slow shouldering fire that produces thick, black smoke, but moderate heat, and which can continue for several hours before bursting into flame. The smoke detector does not contain any radioactive substances and is therefore not harmful for the environment.

Smoke alarm
3 tone bursts in cycles of 1 second (0.5 s sound, 0.5 s silence), repeated with 1.5 s interval, plus red flashing light from the status light.

Temperature alarm
Tone bursts in cycles of 0.3 second (0.2 s sound, 0.1 s silence), plus red flashing light from the status light.

INSTALLATION

  1. Mounting hole
  2. Expander plug
  3. Attachment
  4. Screws
  5. Detector

FIG. 1

Bright-024673-Smart-Smoke-Detector-with-Heat-Sensor-
\(1\)

  1. Insert 2 x AA batteries in the battery compartment.
  2. Check that the smoke detector and its radio communication are working properly.
  3. Hold the attachment against the ceiling and mark out the mounting holes with a pen.
  4. Drill two 5 mm holes.. Tap the plugs in the holes with a hammer.
  5. Fit the attachment over the holes and screw in place with two 3×25 mm screws.
  6. Put the detector on the attachment and turn it clockwise to fasten in place.
  7. Test the smoke detector by pressing the test button. There should be cycles of 3 short tone busts and 1.5 s intervals until the test button is released.
  8. The smoke detector is defective if there is no sound. See the section on troubleshooting.

NOTE:
Always check that the smoke detector is firmly attached and cannot come loose and drop down – risk of personal injury.

FLAT CEILING
Smoke, heat, burning fragments and sparks rise towards the ceiling and spread out. The smoke detector should therefore be installed in the middle of the ceiling.
If installation in the middle of the ceiling is not possible the smoke detector can be put in an optional place on the ceiling, but at least 500 mm from the nearest wall.
FIG. 2

Bright-024673-Smart-Smoke-Detector-with-Heat-Sensor-
\(2\)

SLOPING CEILING
Install 500 mm from the highest point.

  1. Do not put here
  2. Put it in this area
  3. Stationary air
    FIG. 3
    Bright-024673-Smart-Smoke-Detector-with-Heat-Sensor-
\(4\)

SUITABLE PLACES FOR INSTALLATION

  • A smoke detector should be installed in each room in the building (excluding bathroom) to ensure that the alarm is set off in time and is heard by everyone in the building.
  • As a minimum alternative at least one smoke detector should be installed in the hall/passageway between day room and bedroom. Place the smoke detector as close to day rooms as possible and check that the alarm signal can be clearly heard in the bedrooms.
  • Install a smoke detector in the stairway and one or more on each floor.

NOTE:
Several factors can prevent smoke from reaching a smoke detector and setting off an alarm in time. If a fire starts in a remote part of the building, on another floor from where the product is installed, in a chimney, on the other side of a closed door, or on the other side of a wall or ceiling, the smoke may not reach the smoke detector quickly enough for people in the building to be warned in time. A smoke detector does not immediately detect a fire in rooms other than the room it is installed.

UNSUITABLE/INCORRECT INSTALLATION POINTS

  • Near household appliances or areas in which burning normally takes place (kitchen, fireplace, hot water heater etc.).
  • Areas very humid, for example bathrooms or beside dishwasher or washing machine. Install the smoke detector at least 3 metres from such areas.
  • Near return air flows or near outlets from heating or air conditioning systems. Install the smoke detector at least 1 metre from such areas. The air flow can blow away the smoke and therefore prevent setting off the alarm.
  • Rooms in which the temperature can be lower than 0°C or higher than 40°C.
  • Very dusty or strongly polluted areas, or in areas when there are lots of insects.

USE

REPLACING THE BATTERY

  1. Grip the smoke detector casing, twist anticlockwise and unhook the detector from the wall/ceiling holder.
  2. Remove the old batteries from the battery compartment.
  3. Insert two new batteries in the battery compartment with the correct polarity.
  4. Put the detector on the wall/ceiling attachment and turn it clockwise to fasten in place.
  5. Test the smoke detector by pressing the test button. There should be cycles of 3 short tone busts and 1.5 s intervals. If there is no alarm  signal the smoke detector is either defective or incorrectly installed. See troubleshooting section.

Replace the batteries at least once every year.
Do not disconnect the batteries to switch off a false alarm. Fan the air or open a window to remove smoke or dust.

STATUS LIGHT

  1. The red status light flashes every 40 seconds to show that the smoke detector is working properly.
  2. If there is a battery fault or low battery voltage the smoke detector gives a short audio prompt every 40 seconds, together with the flashing red status light.
  3. A short audio prompt is given every 40 seconds for other faults.
  4. If the smoke detector is in quiet mode (alarm signal switched off) the red status light flashes every 8 seconds to show this.

NOTE:
Press the test button to switch off a false alarm signal (audio prompt every 40 seconds).
The false alarm then stays off for 8 hours.
The smoke detector still detects smoke, it is only the false alarm that is temporarily switched off.

SILENT MODE
If an alarm is triggered the alarm signal can be switched off for about 10 minutes each time with the test button. The red status light flashes every 8 seconds to show that the smoke detector is in silent mode (alarm signal switched off). Cookingcan set off an alarm if the smoke detector is installed in a kitchen or near a cooker/kitchenette. Grilling, frying and spillage on hot surfaces can produce large amounts of hot particles.
The normal alarm signal function is reset after about 10 minutes. The alarm will go off again if there are still particles of smoke in the air.
The alarm signal can be switched off several times (silent mode) until the air is free from the particles that triggered the false alarm.

NOTE:
This function should only be used to avoid the smell of cooking triggering a false alarm.

TESTING THE ALARM FUNCTION
Test all the smoke detectors to verify correct installation and function. Test the alarm function every week and when the home has been empty for some time, such as during the holidays.
Stand at an arm’s length from the smoke detector when it is tested. Do not test with a naked flame – risk of damaging the smoke detector.

  1.  Press the test button for at least 5 seconds.
  2. There should be cycles of 3 short tone busts and 1.5 s intervals until the test button is released. The alarm can continue for a few seconds after the test button has been released.

When testing individual products other installed smoke detectors can also trigger an alarm. When the test button is released the other products should stop after 1 minute. The radio communication can be checked in this way.

INSTALL APP

  1. Scan the QR code to download the Smart Life app. Or search on App Store or Google Play.
  2. Register your account with mobile number or email address.
  3. You will then get a verification code via SMS or email. Enter the code in the app and then select password. Log in if you already have an account.
    FIG. 4

CONNECT PRODUCT

  1. Open the app Smart life, click on “+” (add device).

  2. Select Sensors and look for Alarm (Wi-Fi).
    FIG. 5

  3. Select 2.4 GHz Wi-Fi network and enter password.

  4. Tap the smoke detector button 3 times – the LED flashes quickly.

  5. Button

  6. LED light
    FIG. 6

  7. Select “Confirm that indicator is flashing rapidly”.

  8. Select “Flashing”, product and APP are paired.

  9. When the smoke detector has been added, select “Ready”.
    FIG. 7

NOTE:
Repeat the same process with all your alarms.

MAINTENANCE

In addition to testing every week the smoke detector needs to be cleaned regularly to keep it free from dust, dirt and debris.
Vacuum clean the casing of the smoke detector with a soft brush nozzle. Check that all the air holes are free from contamination and foreign objects.

IMPORTANT:

  • Do not attempt to remove the casing and clean inside.
  • Replace the smoke detector and test after cleaning.

TROUBLESHOOTING

Problem Remedy
The alarm signal sound does not sound when tested. Remove the smoke detector

from the wall/ceiling attachment and check that the battery is correctly connected to the battery connectors.
Replace the smoke detector.
The alarm signal sounds and the red status light flashes every 40 seconds.| Replace the batteries according to the instructions.
The audio prompts are abnormal. Alarm signal starts and goes off without obvious reason.| Clean the smoke detector according to the instructions in the maintenance and cleaning section.
The smoke detector is not working properly.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Bright User Manuals

Related Manuals