AXOR 10101000 Electronic Basin Mixer Instruction Manual

June 5, 2024
AXOR

10101000 Electronic Basin Mixer
Instructions for use/assembly instructions

|
---|---

Starck
10101XXX / 10140XXX

|

Starck
10106XXX / 10145XXX

Safety Notes

Gloves should be worn during installation to prevent crushing and cutting injuries.
The shower system may only be used for bathing, hygienic, and body cleansing purposes.
The hot and cold supplies must be of equal pressure.
Only the battery housing with battery or power pack supplied by Hansgrohe may be connected to the electrical connection cable of the fittings.
A damaged connecting line must not be replaced. The transformer may no longer be used.
The transformer and its mains plug may only be installed or plugged in in dry interior rooms.

Installation Instructions

  • The fitting must be installed, flushed, and tested after the valid norms.
  • The mesh washers must be installed to protect against incoming dirt by pipework. Incoming dirt can impair the function and/or lead to damages to functional parts of the fixture; Hansgrohe will not be held liable for resulting damages.
  • The mixer can not be used together with a continuous flow water heater.
  • The fittings must not be installed on washstands with raised edges.
  • At the start of the operation, or after maintenance, the function of the faucet may be delayed due to reflections during adjustment of the operating distance. The faucet will automatically calibrate itself. The self-calibration will start after 10-15 minutes.
  • During initial start-up and after servicing, the air in the fittings can cause an unattractive jet pattern. The jet pattern is okay again after switching the jet on and off about 15 times.

Electrical installation

Electrician

**The installation and test work must be performed by an authorized electrician under consideration of DIN VDE 0100 part 701 / IEC 60364-7-701.
Electrical connection**

Voltage supply: 230 V AC ± 10 % / 50 – 60 Hz / 2 mA
Residual current protection system
The circuit must be protected via a ground fault protector (RCD / FI) with a measured differential current of ≤ 30 mA. The proper function of this fusing/protection must be checked at regular intervals.
Any work may only be carried out in a de-energized state. Here, the voltage supply must be safely separated via the main switch or main plugs.
**The transformer must not be installed in protection zones 0, 1, or 2.
Adjustment**
This mixer has the following feature: background fades out with integrated range adjustment, which means the mixer is automatically adjusted on to the local conditions (washbasin, brightness, reflection) by the sensory mechanism.

Battery operation

The indicator LED signals that the battery must be changed.
Battery voltage ≤ approx. 5.5 V:
The indicator LED in the sensor window blinks when the fitting is operated, water withdrawal continues to be possible
Battery voltage ≤ approx. 5.3 V:
The indicator LED in the sensor window lights continuously, water withdrawal is no longer possible, and the battery must be replaced.
Attention! After insertion of the battery, the fitting should not be activated for approx. 30 seconds. This time is required for self-adjustment.

Power supply pack operation

For the replacement of a power supply pack, the procedure corresponds to the replacement of a battery.
Normal operation
The range of the detection area or the removal of the switch-on/off point from the fittings depends on the ambient optical conditions (for example, the shape and reflection of the washstand and the ambient light) as well as on the shape, the size, the speed and the reflection of the object that was brought into the detection area.
The detection area of the fittings or the distance of the switch-on/off point from the fittings is approx—160 to 200 mm in regular operation.
The detection of dark (for example grey-black) objects by the fittings are inadequate because of their low reflection. The range of the detection area or the distance of the switch-on/off point can be smaller than 160 mm.
The detection of bright or reflecting objects by the fittings is very good as a result of their high reflectivity. The range of the detection area or the distance of the switch on/off point can be greater than 200 mm.
Strong light sources should not shine directly on the sensor window of the fittings.
Drops of water or condensed water on the sensor window of the fittings can initiate the unintended running of the water.

Range setting for infrared proximity electronics

It may be necessary to reduce the range of the infrared proximity electronics by manual mode switching when the fittings are connected to very small or highly reflecting washstands. The following two modes can be selected:

  • “Maximum range” (factory setting)
  • “Reduced range” (maximum range reduced by approx. 50 mm)The LED behind the sensor window signals which mode the fittings are currently in:
  • Short blinking when the fittings are closed = “reduced range”
  • No blinking when the fittings are closed = “maximum range” Perform the following steps to change from “maximum” to “reduced” range or vice versa:
  • Interrupt voltage supply of the fittings for approx. 10 s (disconnect electrical plug connection between fittings and battery housing or power pack and reconnect after 10 s)
  • The LED blinks to indicate the software version (e.g. blinking once = software version 1)
  • When the LED lights permanently (-> calibration of infrared proximity electronics), cover the sensor window completely with your hand or a white piece of paper
  • Remove your hand or the paper after 20 s to 40 s
  • The LED indicates the currently activated mode by blinking: Once = “maximum range”, twice = “reduced range”
  • The LED then lights permanently until the calibration of the just set range of the infrared proximity, the switch has completed
  • When the LED goes off again, the fittings are ready for operation the sensor window is covered for less than approx. 20 s or more than approx. 40 s, the already active mode is maintained and indicated by the corresponding blinking of the LED (once = “maximum range”, twice = “reduced range”).

Technical Data

This mixer series-produced with EcoSmart®
(flow limiter)
Operating pressure: max. 0,8 MPa
Recommended operating pressure: 0,1 – 0,5 MPa
Test pressure: 1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature: max. 80 °C
Recommended hot water temp.: 65 °C
Maximum flowing-out temperature at 50 K temperature difference and 0,3 MPa flow pressure: 42 °C
Follow-on time: 1 – 2 s
Automatic switching-off: after 1 min
Protection class: IP X5
battery: CR-P2 / 6 V Lithium
transformer: 230 V AC ± 10 % / 50 – 60 Hz / 2 mA
The transformer must not be installed in protection zones 0, 1, or 2.

Assembly see page 73

Symbol description

| Do not use silicone-containing acetic acid!
---|---
| Dimensions (see page 79)
| Flow diagram (see page 79)
1. with EcoSmart®
2. without EcoSmart®
| Spare parts (see page 80)
| Operation (see page 75)
| Cleaning washbasin (see page 76)
| Cleaning (see page 77) enclosed brochure
| Maintenance
The non-return valves must be checked regularly according to DIN EN 1717 in accordance with national or regional regulations (at least once a year). (see page78)
| Exchange battery (see page 78)
| Test certificate (see page 79)

Starck
10101XXX / 10106XXX| Starck
10140XXX / 10145XXX
---|---
|

Starck
10101XXX / 10106XXX / 10140XXX / 10145XXX

| P-IX| ACS| ETA
---|---|---|---
10101 XXX| P-IX 18741/IA| X| X
10106XXX| P-IX 18741/IA| X| X
10140XXX| P-IX 18741/IA| X| X
10145XXX| P-IX 18741/IA| X| X

XXX = colors
000 = chrome plated
800 = stainless steel optic

Hansgrohe · Postfach 1145
D-77761 Schiltach
Telefon +49 (0) 78 36/51-1282
Telefax +49 (0) 7836/511440
E-Mail:[email protected]
Internet:www.hansgrohe.com   
7/2010
9.04230.03

Documents / Resources

| AXOR 10101000 Electronic Basin Mixer [pdf] Instruction Manual
10101000, Electronic Basin Mixer, 10101000 Electronic Basin Mixer, Basin Mixer, Mixer
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

AXOR User Manuals

Related Manuals