12 port Ethernet M12 switches
General Information
1.1. Legal Information
The contents of this document are provided “as is”. Except as required by
applicable law, no warranties of any kind are made in relation to the accuracy
and reliability or contents of this document, either expressed or implied,
including but not limited to the implied warranties of merchantability and
fitness for a particular purpose. Westermo reserves the right to revise this
document or withdraw it at any time without prior notice. Under no
circumstances shall Westermo be responsible for any loss of data or income or
any special, incidental, and consequential or indirect damages howsoever
caused. More information about Westermo can be found at
www.westermo.com.
1.2. About This Guide
This guide is intended for installation engineers and users of the Westermo
products It includes information on safety and regulations, a product
description, installation instructions and technical specifications.
1.3. Software Tools
Related software tools are available at www.westermo.com/support/software-
tools.
1.4. License and Copyright for Included FLOSS
This product includes software developed by third parties, including
Free/Libre Open Source Software (FLOSS). The specific license terms and
copyright associated with the
software are included in each software package respectively. Please visit the
product web page for more information. Upon request, the applicable source
code will be provided. A nominal fee may be charged to cover shipping and
media. Please direct any source code request to your normal sales or support
channel.
1.5. WeOS Management Guide
This product runs WeOS 4 (Westermo Operating System). Instructions for quick
start, configuration, factory reset and use of USB port are found in the WeOS
Management
Guide at www.westermo.com.
Safety and Regulations
2.1. Warning Levels
Warning signs are provided to prevent personal injuries and/or damages to the
product. The following levels are used:
Level of warning| Description| Consequence personal injury|
Consequence material damage
---|---|---|---
| Indicates a potentially hazardous situation| Possible death or major
injury| Major damage to the product
| Indicates a potentially hazardous situation| Minor or moderate injury|
Moderate damage to the product
| Provides information in order to avoid misuse of the product, confusion or
misunderstanding| No personal injury| Minor damage to the product
| Used for highlighting general, but important information| No personal
injury| Minor damage to the product
Table 1. Warning levels
2.2. Safety Information Before installation:
Read this manual completely and gather all information available on the
product. Make sure it is fully understood. Check that your application does
not exceed the safe operating
specifications for the product.
SAFETY DURING INSTALLATION
The product must be installed and operated by qualified service personnel and
installed into an apparatus cabinet or similar, where access is restricted to
service personnel only.
Refer to chapter Compliance Information to see the required level of qualified
service personnel according to safety standards. During installation, ensure a
protective earthing conductor is first connected to the protective earthing
terminal (only valid for metallic housings). Westermo recommends a cross-
sectional area of at least 4 mm2. Note that this product can be connected to
two different power sources. Upon removal of the product, ensure that the
protective earthing conductor is disconnected last.
HAZARDOUS VOLTAGE
Do not open an energized product. Hazardous voltage may occur when connected
to a power supply.
PROTECTIVE FUSE
The power supply wiring must be sufficiently fused. The fuse must be IEC 60127
certified and rated for T1.6 A and 250 V. It must be possible to disconnect
manually from the power supply. Ensure compliance to national installation
regulations. This product has no internal fuse and should be connected via an
external fuse for protection.
REDUCE THE RISK OF FIRE
To reduce the risk of fire, use only telecommunication line cords with a cable
diameter of AWG 26 or larger. Regarding power cable dimensions, see chapter
Interface Specifications.
CABLE TEMPERATURE RATING FOR FIELD TERMINAL WIRES
There may be a requirement on the minimum temperature rating of the cable to
be connected to the field wiring terminals, see chapter Interface
Specifications.
ELECTROSTATIC DISCHARGE (ESD)
Prevent electrostatic discharge damage to internal electronic parts by
discharging your body to a grounding point (e.g. use a wrist strap).
HOT SURFACE
Be aware that the surface of this product may become hot. When it is operated
at high temperatures, the external surface may exceed Touch Temperature Limit
according to the product’s relevant electrical safety standard.
NOTE – MECHANICAL FORCE ON VENTILATION MEMBRANE
Do not cover or bring mechanical force to the ventilation membrane on the back
of the product.
2.3. Care Recommendations
Follow the care recommendations below to maintain the full operation of the
product and to fulfill the warranty obligations:
- Do not drop, knock or shake the product. Rough handling above the specification may cause damage to internal circuit boards.
- Use a dry or slightly water-damp cloth to clean the product. Do not use harsh chemicals, cleaning solvents, or strong detergents.
- Do not paint the product. Paint can clog the product and prevent proper operation.
If the product is used in a manner not according to specification, the protection provided by the equipment may be impaired.
If the product is not working properly, contact the place of purchase, the nearest Westermo distributor office or Westermo technical support.
2.4. Product Disposal
This symbol means that the product shall not be treated as unsorted municipal
waste when . disposing of it. It needs to be handed over to an applicable
collection point for recycling electrical and electronic equipment. By
ensuring the product is disposed of correctly, you will help to reduce
hazardous substances and prevent potential negative consequences to both the
environment and human health, which could be caused by inappropriate disposal.
Figure 1. WEEE symbol for treatment of product disposal
2.5. Compliance Information
2.5.1. Agency Approvals and Standards Compliance
Type | Approval/Compliance |
---|---|
Climate |
- EN 50155 class OT4 / IEC 60571 class TX, Railway applications – Electronic equipment used on rolling stock
- IEEE 1478 class 1, condition E4 (incl Salt Mist), Environmental conditions for transit rail car electronic equipment
EMC|
- EN/IEC 61000-6-2, Immunity industrial environments
- EN/IEC 61000-6-4, Emission industrial environments
- EN 50121-4/IEC 62236-4, Railway signalling and telecommunications apparatus EN 50121-3-2/IEC 62236-3-2 Railway applications — Rolling stock — apparatus Tested and verified for Class 51, DB EMC Regulation 06, Commodity team Radio compatibility in VDB Rev 1.0 (Shunting Radio)
- Tested and verified for FCC part 15b class A (CFR 47)
- E-Mark, Road Vehicles, El 10R-058547
Mechanical (Shock and vibration)|
- EN 61373 category 1, class A and B
- EN 60068-2-27 20 g, 11 ms and 100 g, 6 ms
Insulation (Coordination and test)|
- EN 50124-1, Railway applications — Insulation coordination
- EN 50155/IEC 60571, Railway applications – Electronic equipment used on rolling stock
Fire protection|
- EN 45545-2, Fire protection on railway vehicles
- NFPA 130, Fire protection for fixed guideway transit and passenger rail system
Software|
- EN 50657:2017 Software Onboard Rolling Stock (Basic Integrity)
Safety|
- EN/IEC/UL 61010-1, -2-201, Safety requirements for electrical equipment for measurement, control, and laboratory use
Table 2. Agency approvals and standards compliance
2.5.2. EN/IEC/UL 61010-2-201 Notice
This product has been tested and found compliant to EN/IEC/UL 61010-2-201,
Safety requirements for electrical equipment for measurement, control, and
laboratory use. In
In accordance with the definitions of the standard, this product shall be
handled by skilled service personnel.
2.5.3. FCC Part 15.105 Class A Notice
This product has been tested and found to comply with the limits for a Class A
digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when
the product is operated in a commercial environment. This product generates,
uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the user manual, may cause harmful interference to radio
communications. Operation of this product in a residential area is likely to
cause harmful interference in which case the user will be required to correct
the interference at the user’s own expense.
2.5.4. Simplified Declaration of Conformity
Hereby, Westermo declares that this product is in compliance with applicable
EU directives and UK legislation. The full declaration of conformity and other
detailed information is available at www.westermo.com/support/product-
support.
Figure 2. The European Conformity and the UK Conformity Assessment markings
Product Description
3.1. Product Description
The Viper-12A series consists of managed 12 port routing switches optimized
for the needs of the railway rolling stock market. Gbps ports cope with high
bandwidth devices such as access points and NVRs (Network Video Recorders).
The Viper-12A series is designed to withstand the tough environment on-board
trains, exposing the switch to constant vibration, extreme temperatures,
humidity, and a demanding electrical environment. A GORE-TEX® membrane
prevents internal condensation. Threading integrated in the chassis provides
for additional vibration resistance. High-level isolation between all
interfaces enables direct connectivity to vehicle auxiliary power and protects
against overvoltage and flashover. IP67 protection prevents the ingress of
water and dust. An overall optimized design results in an extremely compact
package in combination with very high MTBF for easy integration and low
lifecycle cost. Thorough type testing at independent ISO/IEC 17025 and ILAC
MRA certified labs, accredited to a wide range of standards, show that the
Viper series fulfills EN 50155 and other requirements. The state-of-the-art
Westermo production facility ensures the quality of each individual unit, e.g.
through temperature cycling burn-in testing. The WeOS operating system offers
an extensive suite of IP networking features for resilient and flexible
networks, e.g. the FRNT ring protocol with very fast failover. The powerful
layer 3 routing capability is very useful for separating networks in complex
applications. The backup device accessory matches the Viper in robustness and
offers easy configuration update and backup. Meeting the requirements of the
railcar market, the Viper-12A series is very well suited for deployment in any
other application with severe operating conditions and tough environments, for
instance in the mining industry.
3.2. Available Models
All switches are managed. Viper x12A is used when referring to both models
112A and 212A.
Art. no. | Model | Software | Gbps ports |
---|---|---|---|
3635-0010 | Viper-112A | L2 | – |
3635-0310 | Viper-112A-T3G | L2 | 3 |
3635-0610 | Viper-112A-T5G | L2 | 5 |
3635-0020 | Viper-212A | L3 | – |
3635-0320 | Viper-212A-T3G | L3 | 3 |
3635-0620 | Viper-212A-T5G | L3 | 5 |
NOTE – MECHANICAL FORCE ON VENTILATION MEMBRANE
Do not cover or bring mechanical force to the ventilation membrane on the back
of the product.
3.3. Hardware Overview
No. | Description | No. | Description |
---|---|---|---|
1 | LED indicator | 2 | 100 Mbps port |
3 | Gbps port | 4 | Power connection |
5 | Console port | 6 | Protective earth connection |
7 | USB port |
Figure 3. Location of interface ports and LED indicators
3.4. Connector Pinout
Pin no. | Signal | Illustration |
---|---|---|
1 | +DC1 | **** |
2 | +DC2 | |
3 | -COM | |
4 | -COM |
Viper-x12A supports a redundant power connection. The positive inputs are +DC1 and +DC2. The negative input for both supplies is -COM
Table 4. Power connector
Pin no. | Signal | Illustration |
---|---|---|
1 | NCA | __ |
2 | TX | |
3 | RX | |
4 | NCA | |
5 | GND |
aNo Connect. Do not connect.
Table 5. Console connector
Pin no. | Signal | Illustration |
---|---|---|
1 | DN | __ |
2 | VBUS | |
3 | NCa | |
4 | DC | |
5 | GND |
aNo Connect. Do not connect.
Table 6. USB connector
Pin no. | Signal | Illustration |
---|---|---|
1 | TD+ | __ |
2 | RD+ | |
3 | TD- | |
4 | RD- |
MDI, MDI-X and auto MDI/MDI-X modes are supported. The table shows signals in MDI mode.
Table 7. 100 Mbps Ethernet connector
Pin no. | Signal | Illustration |
---|---|---|
1 | DA+ | _![westermo Viper 12A Series 12 Port Ethernet M12 switches - Ethernet |
connector](https://manuals.plus/wp-content/uploads/2022/03/westermo-Viper-12A-
Series-12-Port-Ethernet-M12-switches-Ethernet-connector.png)_
2| DA-
3| DB+
4| DB-
5| DD+
6| DD-
7| DC-
8| DC+
Table 8. Gbps connector
3.5. LED Indicators
LED | Status | Description |
---|---|---|
ON | OFF | The product has no power |
GREEN | All OK, no alarm condition | |
RED | Alarm condition, or until the product has started up. (Alarm conditions |
are configurable, see WeOS Management Guide )
BLINK| Location indicator (“Here I am!”). Activated when connected to WeConfig
tool, or upon request from web or/and CLI. RED BLINK during boot indicates
pending cable factory reset.
RSTP| OFF| RSTP disabled
GREEN| RSTP enabled
BLINK| Product selected as RSTP/STP root switch
FRNT| OFF| FRNT disabled
GREEN| FRNT OK
RED| FRNT error
BLINK| Product configured as FRNT focal point
DC| OFF| The product has no power
GREEN| Power OK on DC1 and DC2
RED| Power failure on DC1 or DC2
X1 to X12| OFF| No link
GREEN| Link established
GREEN FLASH| Data traffic indication
YELLOW| Port alarm or port is set in blocking state by link redundancy
protocol
3.6. Dimensions
Dimensions are stated in mm.
Installation
4.1. Wall Mounting
The product can be wall-mounted vertically or horizontally. There are four
pieces of 7 mm bores for this. Use four M5, M6 or 1/4″ screws with 12 mm
washers on a flat and stable surface.
4.2. Protective Earth Connection
For correct function, the earth connection needs to be properly connected to a
designated PE rail. See the figure below.
4.3. Connection of Cables
Recommended tightening torque for the M12 connectors is 0.6 Nm. All M12
connections are screw connections.
When connecting the power cable, ensure that the pins are connected correctly
before tightening the power cable to the unit.
PROTECTIVE FUSE
The power supply wiring must be sufficiently fused. The fuse must be IEC 60127
certified and rated for T1.6 A and 250 V. It must be possible to disconnect
manually from the power supply. Ensure compliance with national installation
regulations. This product has no internal fuse and should be connected via an
external fuse for protection.
NOTE – UNUSED CONNECTORS
Unused connectors must be covered by a protective cap (delivered with the
product), and tightened to the specified torque in order to fulfill the
specified ingress protection code.
4.4. Cooling
This product relies on convection cooling. Make sure that it is installed so
that the ambient temperature is within the specified temperature range. Avoid
obstruction of the airflow around the product.
4.5. Replacement of Product
Disconnect all cables and unscrew the product from the wall. Mount the
replacement product and reconnect all cables, observing the instructions in
Connection of Cables [18].
For easy replication of the configuration of the original product, it is
recommended to have the Westermo USB plug permanently connected to the USB
port and move it over to the replacement product before it is powered up.
MTTR (Mean Time To Repair), i.e. time for replacement of the product is: < 10
minutes.
HOT SURFACE
Be aware that the surface of this product may become hot. When it is operated
at high temperatures, the external surface may exceed the Touch Temperature
Limit according to the product’s relevant electrical safety standard.
4.6. EN 45545-2 Mounting Notes
Two products can be mounted together and as a single interior non-listed group
in the sense of EN 45545-2 definitions. For multiple products, the spacing
requirements for interior non-listed groups must be met.
Specifications
5.1. Interface Specifications
DC, Power port
Rated voltage| 24 to 110 VDC
Operating voltage b| 16.8 to 143 VDC (14.4 VDC to 100 ms and 154 VDC for
1 s)
Rated current| Max 580 mA at 24 VDC, max 140 mA at 110 VDC
Rated frequency| DC
Inrush current| 80 mA²s at 24 VDC, 140 mA²s at 110 VDC
Startup current| Max 840 mA at 16.8 VDC
Polarity| Reverse polarity protected
Redundant power input| Yes
Isolation| To all other ports
Circuit type| Secondary circuit hazardous voltage, OVC II
Connector| 4-pin, male, M12, A-coded, recommended Westermo cables:
3146-1106 for 1.5 m
3146-1107 for 5 m
Cable size| M12, recommended power cable area 0.5 mm² (minimum 0.25 mm²), which correlates to AWG 21 or larger
Cable dimensions depend on the choice of M12 connector
Cable temperature rating| For minimum temperature rating of the cable to be connected to the field wiring terminals: -40 to +70 °C
also referred to as nominal voltage in EN/IEC 61010-1
bAlso referred to as nominal input including fluctuations in EN/IEC 61010-1
100 Mbps ports a
Electrical specification| IEEE std 802.3
Data rate| 10 Mbps, 100 Mbps, manual or auto
Duplex| Full or half, manual or auto
Circuit type| TNV-1
Transmission range| Up to 150 m with CAT5e cable or better
Isolation| To all other ports
Connector| 4-pin, female, M12, D-coded, auto MDI/MDI-X, recommended
Westermo cables:
3146-1100 M12-M12 – 1 m
3146-1101 M12-M12 – 5 m
3146-1103 RJ45-M12 – 1 m
3146-1104 RJ45-M12 – 5 m
Cabling| Shielded cable CAT5e or better is recommended
Conductive chassis| Yes
FRNT reconfiguration time| Typically below 20 ms
a100 Mbps ports are:
X1-X12 on Viper-x12A
X1-X3, X5-X7, X9-X11 on Viper-x12A-T3G
X1, X5-X7, X9-X11 on Viper-x12A-T5G
Gbps ports a
Electrical specification| IEEE std 802.3
Data rate| 10 Mbps, 100 Mbps, 1000 Mbps, manual or auto
Circuit type| TNV-1
Transmission range| Up to 150 m with CAT5e cable or better
Isolation| To all other ports
Connector| 8-pin, female, M12, X-coded
Cabling| Shielded cable CAT5e or better is recommended
Conductive chassis| Yes
FRNT reconfiguration time| Typically below 20 ms
aGbps ports are: X4, X8, X12 on Viper-x12A-T3G, X2-X4, X8, X12 on Viper-x12A- T5G
USB port
Electrical specification| USB 2.0 host interface
Data rate| Up to 480 Mbps (high-speed mode)
Maximum supply current| 500 mA
Circuit type| SELV
Isolation| To all Ethernet and DC ports No isolation to CON or
protective earth
Connector| 5-pin, female, M12, A-coded, recommended Westermo USB plug
3641-0190
Console port
Electrical specification| RS-232
Data rate| 115.2 kbit/s
Data format| 8 data bits, no parity, 1 stop bit, no flow control
Circuit type| SELV
Isolation| To all Ethernet and DC ports No isolation to USB or
protective earth
Connector| 5-pin, female, M12, B-coded, recommended Westermo cables:
1211-2215 (serial port) or 1211-4073 (USB)
5.2. Type Tests and Environmental Conditions
Environmental phenomena| Basic standard| Description| Test
levels
---|---|---|---
ESD| EN 61000-4-2| Enclosure| Contact: ±6 kV Air: ±8 kV
Fast transients| EN 61000-4-4| Power port| ± 2 kV
Signal ports
Earth port
Surge| EN 61000-4-5| Power port| L-E: ± 2 kV, 42 Ω, 0.5 µF, 1.2/50 µs
L-E: ± 0.5 kV, 12 Ω, 9 µF, 1.2/50 µs L-L: ± 2 kV, 42 Ω, 0.5 µF, 1.2/50 µs L-L:
± 0.5 kV, 2 Ω, 18 µF, 1.2/50 µs
Ethernet port| L-E: ± 2 kV, 2 Ω
Pulsed magnetic field| EN 61000-4-9| Enclosure| 300 A/m
Radiated RF immunity| EN 61000-4-3| Enclosure| 20 V/m at (80 MHz to
2 GHz)
10 V/m at (2-6 GHz)
1 kHz sine, 80% AM
Conducted RF immunity| EN 61000-4-6| Power port| 10 V, 80% AM, 1
kHz; (0.15-80) MHz
Ethernet ports
Earth port
Radiated RF emission| CISPR 16-2-3| Enclosure| EN 61000-6-4 (30-6000
MHz)
ANSI C63,4 (FCC Part 15)| EN 61000-6-4 (30-6500 MHz)
Conducted RF emission| CISPR 16-2-1| Power port| EN 61000-6-4
Ethernet ports| EN 61000-6-3
Dielectric strength| EN 60950-1| Power port to all other ports| 2250
VDC, 1 min
Ethernet ports to all other ports| 2250 VDC, 1 mina
Gbps Ethernet ports to all other ports| 2250 VDC, 1 mina
a750 VDC after damp heat, according to EN 50155
Table 10. EMC and electrical conditions
Environmental phenomena| Basic standard| Description| Test
levels
---|---|---|---
Temperatures| EN 60068-2-1
EN 60068-2-2| Operational| -40 to +70°C (-40 to +158°F)ab
Storage and transport| -55 to +85°C (-67 to +185°F)
Humidity| EN 60068-2-30| Operational| 5-95% relative humidity
Storage and transport
Altitude| | Operational| 2000 m
Service life| | Operational| 20 years according to IEC/TR 62380
MTBF| 1: MIL-217F2, GB, 25°C (+77°F) 2: IEC 62380| | Viper-x12A: 1:
557,000 h
Viper-x12A-T3G: 1: 549,000 h, 2: 561,000 h
Viper-x12A-T5G: 1: 544,000 h
Vibration| IEC 60068-2-6 (sine)| Operational| 2 g rms 5-500 Hz, 5 sweeps
IEC 60068-2-64 (random)| Non-operational long life simulation| 11.44 m/s² rms
5-150 Hz, 5 hours
2.3 m/s² rms 5-2000 Hz, 5 hours
Shock| DEC
60068-2-27| Operational| 10 g, 30 ms, half-sine
20 g, 11 ms, saw tooth
100 g, 6 ms, half-sine
Weight| | | 1.4 kg
Degree of protection| EN 60529| Enclosure| IP67
Cooling| | | Convection
Overvoltage category| EN/IEC/UL 61010-1| | OVC II
Pollution degree| EN/IEC/UL 61010-1| | PD3 macro environment and PD2
microenvironment
EN 50124-1| | PD2
Location| EN/IEC/UL 61010-1| | Outdoor, wet locations
IEEE 1478| | Class 1, condition E4. Indoor
Refers to the “Safety and Regulations” chapter regarding touch temperature
Operational at +85°C for a limited time
installation and maintenance shall be made under controlled environments.
Table 11. Environmental and mechanical conditions
Revision Notes
Revision| Date|
Change description
---|---|---
Rev. L| 2022-01| 2.2 Safety Information updated (Warning – Safety during
installation), 2.5.1. Agency Approvals and Standards Compliance (Software plus
Safety added), 2.5.2 EN/IEC/UL 61010-2-210 Notice added, 5.2 Type Tests and
Environmental Conditions updated (UL added to EN/IEC 61010-1)
Rev. K| 2021-12| 5.1 Interface Specification updated (DC Power port; operating
voltage)
Rev. J| 2021-05|
Westermo logo updated, blue product illustrations throughout the user guide,
2.2 Safety Information – various warnings updated in accordance with General
and Information Safety manual, 2.3 Care Recommendations, text updated, old
chapter 2.4 Maintenance deleted 2.5.1. Agency Approvals and Standards
Compliance updated 2.5.3 Simplified Declaration of Conformity; text and figure
updated, 3.1. Product Description updated,
3.4. Connector Pinout, illustration for table 5 updated, 3.6. Dimensions,
illustration updated, 4.2. Earth connection chapter added 5.1. Interface
Specifications updated (all tables), 5.2 Type Tests and Environmental
Conditions updated (Altitude updated, Enclosure deleted, Overvoltage category
added, Pollution degree added and Location added).
Rev. I| 2020-01| 2.6.1 Agency Approvals and Standards Compliance – references
to SBB requirements and ÖBB removed, 5.1 Interface Specifications (rated
current) updated.
Rev. H| 2019-09|
5.1 Interface specification updated with new inrush current value.
Rev. G| 2019-06| Frontpage updated, “unit” changed to “product” throughout the
user guide, 1.3 Software Tools text updated, 2.2 Safety Information: Notice –
Mechanical force on ventilation membrane new information, 2.3 Care
Recommendations text updated, 2.6.1 Agency Approvals and Standards Compliance
updated (E-mark), 4.4 Replacement of Product text updated
Rev. F| 2018-12| 2.2 Safety Information with a specific symbol for Caution –
Hot surface, and text in Notice – Connect external fuse updated, 2.5
Environmental Protection updated to Product disposal, 2.6.1 Agency Approvals
table updated, 2.6.3 Declaration of Conformity updated to Simplified
Declaration of Conformity, 3.3 Hardware Overview table updated, 4.2 updated
with Notice – Connect external fuse, 4.4 symbols for Caution – Hot surface
updated, 5.1 Interface specifications updated with inrush current, 5.2 Type
Tests and Environmental Conditions – enclosure updated, end page updated
Rev. E| 2017-09| 2.1. Definition of personal injury at Caution level updated,
2.6.1 Mechanical data updated, chapter 3.6 updated, 5.1 Interface
Specifications updated – Transmission range for 100 Mbps ports and Gbps ports
changed to 150 m, 5.2 Type Tests and Environmental Conditions – Enclosure
updated, Radiated + Conducted RF emission updated
Rev. D| 2017-07| New layout for user guide with rearranged chapters, chapter 1
text updated, new chapter 1.5, chapter 2.1 new defining Warning levels,
chapter 2.6.1 Agency approvals updated (Shock and NFPA 130), updated text in
chapter 3.1, “±” removed from “±2250 VDC” throughout the user
Revision| Date| Change description
---|---|---
| |
guide, radiated RF immunity, service life, shock, and operating temperature updated in chapter 5.2. Old chapters Getting Started, Configuration, Reference documents, and Cable factory reset are deleted.
Westermo • Metallverksgatan 6, SE-721 30 Västerås, Sweden
Tel +46 16 42 80 00 Fax +46 16 42 80 01
E-mail: info@westermo.com
www.westermo.com
6641-22511 REV. L 2022 01
Westermo Network Technologies AB, Sweden
References
- Westermo ᐅ Robust and Secure Industrial Networking Solutions
- Product support, user guides and software downloads ᐅ Westermo
- Legacy Software Tools ᐅ Westermo
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>