westermo Viper-008 Unmanaged 8-port Ethernet Switch User Guide

June 6, 2024
westermo

westermo logo

Viper 008
Unmanaged 8-port Ethernet Switch

General Information

Legal Information

The contents of this document are provided “as is”. Except as required by applicable law, no warranties of any kind are made in relation to the accuracy and reliability or contents of this document, either expressed or implied, including but not limited to the implied warranties of merchantability and fitness for a particular purpose. Westermo reserves the right to revise this document or withdraw it at any time without prior notice.
Under no circumstances shall Westermo be responsible for any loss of data or income or any special, incidental, consequential, or indirect damages howsoever caused.
More information about Westermo can be found at www.westermo.com

Safety and Regulations

Warning signs are provided to prevent personal injury and/or damage to the product.
The following levels are used:

Level of warning| Description| Consequence personal injury|

Consequence material damage

---|---|---|---

WARNING

| Indicates a potentially hazardous situation| Possible death or major injury| Major damage to the product

****CAUTION

| Indicates a potentially hazardous situation| Minor or moderate injury| Moderate damage to the product

****NOTICE

| Provides information in order to avoid misuse of the product, confusion, or misunderstanding| No personal injury| Minor damage to the product

****NOTE

| Used for highlighting general, but important information| No personal injury| Minor damage to the product

Before Installation

Read this manual completely and gather all information on the product. Make sure that you understand it fully. Check that your application does not exceed the safe operating specifications for this product.

SAFETY DURING INSTALLATION
The product must be installed by qualified service personnel and built into an apparatus cabinet or similar, where access is restricted to service personnel only.
Refer to Compliance Information to see the required level of qualified service personnel according to safety standards.
During installation, ensure a protective earthing conductor is first connected to the protective earthing terminal (only valid for metallic housings). Westermo recommends a cross-sectional area of at least 4 mm2.
Upon removal of the product, ensure that the protective earthing conductor is disconnected last.

HAZARDOUS VOLTAGE
Do not open an energized product. Hazardous voltage may occur when connected to a power supply.

PROTECTIVE FUSE
The power supply wiring must be sufficiently fused. The fuse must be IEC 60127 certified and rated for T1.25 A and 250 V.
It must be possible to disconnect manually from the power supply.
Ensure compliance with national installation regulations.
This product has no internal fuse and should be connected via an external fuse for protection.

REDUCE THE RISK OF FIRE
To reduce the risk of fire, use only telecommunication line cords with a cable diameter of AWG 26 or larger. Regarding power cable dimensions, see chapter Interface Specifications.

HOT SURFACE
Be aware that the surface of this product may become hot. When it is operated at high temperatures, the external surface may exceed the Touch Temperature Limit according to the product’s relevant electrical safety standard.

ELECTROSTATIC DISCHARGE (ESD)
Prevent electrostatic discharge damage to internal electronic parts by discharging your body to a grounding point (e.g. use a wrist strap).

Care Recommendations

Follow the care recommendations below to maintain the full operation of the product and to fulfil the warranty obligations:

  • Do not drop, knock or shake the product. Rough handling above the specification may cause damage to internal circuit boards.
  • Use a dry or slightly water-damp cloth to clean the product. Do not use harsh chemicals, cleaning solvents or strong detergents.
  • Do not paint the product. Paint can clog the product and prevent proper operation.

If the product is used in a manner not according to specification, the protection provided by the equipment may be impaired.
If the product is not working properly, contact the place of purchase, nearest Westermo distributor office, or Westermo technical support.

Product Disposal

This symbol means that the product shall not be treated as unsorted municipal waste when disposed of it. It needs to be handed over to an applicable collection point for recycling electrical and electronic equipment.
By ensuring this product is disposed of correctly, you will help to reduce hazardous substances and prevent potential negative consequences to both environment and human health, which could be caused by inappropriate disposal.

Compliance Information

Agency Approvals and Standards Compliance
Type Approval / Compliance
EMC EN 61000-6-1, Immunity residential environments

EN 61000-6-2, Immunity industrial environments
EN 61000-6-3, Emission residential environments
EN 61000-6-4, Emission industrial environments
EN 50121-3-2, Railway applications – EMC: Rolling stock – Apparatus
EN 50121-4, Railway signaling and telecommunications apparatus
IEC 62236-4, Railway signaling and telecommunications apparatus
Environmental| EN 50155 Railway applications – Electronic equipment used on rolling stock
Fire protection| EN 45545-2, Fire protection on railway vehicles
Safety| EN/IEC/UL 62368-1, Safety Requirements for audio/video, information, and communication technology equipment

EN/IEC/UL 62368-1 Notice

This product has been tested and found compliant with EN/IEC/UL 62368-1, Safety for Communication Technology. In accordance with the definitions of the standard, this product shall be handled by ordinary personnel. Energy source classifications are according to the following:

EN/IEC/UL 62368-1 notice

Electrical energy source| Power port| ES1 (at 24 VDC) ES3 (at 110 VDC)
Serial port| ES1
Ethernet port| ES1, TNV-1
Power source| Power port| PS3
Thermal energy source| Enclosure| TS1
Mechanical energy source| Enclosure| MS1 (MS3 for wall or ceiling mounting)
Radiation energy source| N/A| N/A

FCC Part 15.105 Notice:

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna
  • Increase the separation between the equipment and receiver
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
  • Consult the dealer or an experienced radio/TV technician for help.
Declaration of Conformity

Hereby, Westermo declares that this product is in compliance with applicable EU directives and UK legislation. The full declaration of conformity and other detailed information is available at www.westermo.com/support/product- support.

Type Tests and Environmental Conditions
Phenomena Test Description Test levels
ESD EN 61000-4-2 Enclosure contact ± 6 kV (crit A)
Enclosure air ± 8 kV (crit A)
RF field AM modulated IEC 61000-4-3 Enclosure 20 V/m 80% AM (1 kHz),

80 – 2500 MHz (crit A)
10 V/m 80% AM (1 kHz),
2700 – 6000 MHz (crit A)

Fast transient| EN 61000-4-4| Ethernet ports| ± 2 kV (crit A)
Power port| ± 2 kV (crit A)
Earth port| ± 2 kV (crit A)
Surge| EN 61000-4-5| Fault port| ± 2 kV line to earth (crit A)
Ethernet ports| ± 2 kV line to earth (crit A)
Power port| ± 2 kV line to earth, ± 2 kV line to line (crit A)
RF conducted| EN 61000-4-6| Ethernet ports| 10 V 80% AM (1 kHz), 0.15 – 80 MHz (crit A)
Power port| 10 V 80% AM (1 kHz), 0.15 – 80 MHz (crit A)
Power frequency magnetic field| EN 61000-4-8| Enclosure| 1000 A/m 50 Hz
300 A/m 16.7 Hz, 60 Hz, DC (crit A)
Pulse magnetic field| EN 61000-4-9| Enclosure| 300 A/m (crit A)
Voltage dips and interruption| EN 50155| DC power ports| 10 ms interruption, 100 ms ±40% voltage variation
Radiated emission| CISPR 16-2-3 ANSI C63.4 (FCC part 15)| Enclosure| Class B (30 – 6000 MHz)
Conducted emission| CISPR 16-2-1| DC power port & Ethernet ports| Class B
Dielectric strength| EN 50155| Ethernet ports to other isolated ports| 500 VAC 1 min
Power & Fault port to other isolated ports| 1500 VAC 1 min
Temperature| EN 60068-2-1
EN 60068-2-2| Operating| -40 to +70ºC
Storage & Transport| -40 to +85ºC
Humidity| EN 60068-2-30| Operating| 5 to 95% relative humidity
Storage & Transport| 5 to 95% relative humidity
Altitude| | Operating| 2000 m / 70 kPa
Reliability prediction (MTBF)| MIL-C217F2, GB| Operating| 150 years @ 20 ºC

147 years @ 40 ºC
135 years @ 60 ºC

Service life| | Operating| 10 years
Vibration, random simulated long life| IEC 60068-2-64,

Cat. 1 class B (EN 61373)

| Not Operating| Vertical: 7.9 m/s2
Transverse: 7.9 m/s2
Longitudinal: 7.9 m/s2
3 x 5 h
Vibration, random functional| IEC 60068-2-64,

Cat. 1 class B (EN 61373)

| Operating| Vertical: 1.0 m/s2
Transverse:  1.0 m/s
Longitudinal: 1.0 m/s2
3 x 10 min
Shock, half sine pulses| IEC 60068-2-27, Cat. 1 class B (EN 61373)| Operating| Vertical: 50 m/s2
Transverse: 50 m/s2
Longitudinal: 50 m/s2
30 ms, 3 x 6 shocks
Shock, sawtooth| IEC 60068-2-27, Cat. 1 class B (IEEE1478-2001)| Operating| Vertical: 100 m/s2
Transverse: 100 m/s2
Longitudinal: 100 m/s2
11 ms, 3 x 6 shocks
Enclosure| UL 94| Nickel coated zinc| Flammability class V-1
Dimension W x H x D| | | 175 x 100 x 53,4 mm
Weight| | | 0.9 kg
Degree of protection| IEC 529| Enclosure| IP 65 when all ports are protected/connected else IP 40
Cooling| | | Convection
Mounting| | | DIN-Rail or wall mounted

Description

Viper 008 is an unmanaged switch developed for rail and industrial applications. To meet the environmental requirements from rail and harsh industrial applications the switch has rugged M12 Ethernet connectors and full metal housing. The IP65 sealed metal case makes it robust and allows for the surrounding air temperature to be between -40 to +70°C. There are no sensitive or fragile components, hardening the product against shock and vibration making these units suitable for rolling stock usage. The power supply operates over a wide input range from 24 to 110 VDC.

Interface Specifications

Power and fault relay port PWR

Rated voltage| 24 to 110 VDC
Operating voltage| 16.8 to 143 VDC (14.4 to 154 VDC for 100 ms)
Rated current| 110 mA @ 24 VDC
33 mA @ 110 VDC
Rated frequency| DC
Inrush current, I2t| Max 0.02 A2s @ 24 – 110 VDC
Polarity| Reverse polarity protected
Startup current*| 300 mA @ 16.8 VDC
Redundant power input| No
Isolation to| Connections X1 – X8 and to ground 1500 VAC.
Fault relay belongs to the same isolation group as the power supply lines (fault relay signals are also contained within PWR).
Connection| 4 pin male M12 connector with A-code
Connector size| M12, recommended cable area 0.5 mm2 recommended (minimum 0.25 mm2), cable dimensions depend on the choice of M12 connector
Shielded cable| Not required, twisted pair is recommended
Fault relay resistance| < 10 Ω

*If an external power supply is used it must meet specified startup

M12 A-coded Power Connector

| Position| Direction| Description
---|---|---|---
1| U+| Positive supply voltage
2| Out| Alarm relay (status) +
3| 0 V| Negative supply voltage
4| Out| Alarm relay (status) –
Housing| Shield| Chassis of the product (ground)

Fault Contact

The Viper switch is equipped with a potential free normally closed fault contact. The fault contact is a solid-state component (relay) that requires power to work and it is transient protected. Additionally, the fault contact is opened when any of the following conditions are met:

  • No voltage on the power supply pin, a voltage level outside the legal voltage range, or current limitation on the voltage source is applied to the power input. A description of how the connection to the fault contact could be done is shown below. The relay is closed when the unit is OK and open at failure. The relay is of semiconductor type (no moving parts). It is specified for max current 250 mA continuous, 500 mA peak (10 ms), operational voltage up to 110 V, protected by a 150 VDC-varistor, ON-resistance less than 10 Ohm, and leakage current max 1 µA.
    |
    ---|---
Service Port

The Service Port should not be used by nonother than the Westermo Technical Support team. Do not connect any device or cable to the Service Port.

Ethernet TX port X1 to X8

Electrical specification| IEEE std 802.3. 2005 Edition
Data rate| 10 Mbit/s or 100 Mbit/s
Duplex| Full or half
Circuit type| TNV-1
Transmission range| 100 m
Isolation to| Other Ethernet ports, 500 VAC
PWR, 1500 VAC
Galvanic connection to| None, except for shielded contact to housing
Connection| 4-pole M12 female with D-code
Shielded cable| Not required, twisted pair is recommended
Conductive housing| Nickel-plated zinc, metal housings of X1-X8 also connected to the housing
Number of ports| 8 Ethernet (X1-X8)
| Position| Direction| Description
---|---|---|---
1| Out| Transmit Data +
2| In| Receive Data +
3| Out| Transmit Data –
4| In| Receive Data –
Housing| Shield| Chassis of the product (ground)

Location of Interface Ports, LEDs

LED indicators

Mounting, DIN-rail

This unit can be mounted on a 35 mm DIN-rail, which is horizontally mounted inside an apparatus cabinet or similar. Snap-on mounting, see figure.

Removal

Press down the support at the back of the unit using a screwdriver. See figure.

Wall Mounting

There are four 6 mm boreholes intended for mounting the unit. The unit can be mounted vertical or horizontal. Use four M6 screws with 12 mm washer on a flat and stable surface.

Removal
Disconnect all cables and unscrew the unit from the wall.
Cooling
This unit uses convection cooling. Avoid obstructing the airflow around the unit. Spacing is recommended for the use of the unit in the full operating temperature range and service life.

Dimensions

Measurements are stated in millimeters.

westermo logo

Westermo • Metallverksgatan 6, SE-721 30 Västerås, Sweden
Tel +46 16 42 80 00 Fax +46 16 42 80 01
E-mail: info@westermo.com
www.westermo.com