WESTERMO Ibex-1510 Series Wi-Fi 6 Dual Radio Access Point User Guide
- May 15, 2024
- westermo
Table of Contents
WESTERMO Ibex-1510 Series Wi-Fi 6 Dual Radio Access Point
Specifications
- Interface Specifications: Detailed interface specifications can be found in section 5.1 of the user manual.
- Type Tests and Environmental Conditions: Refer to section 5.2 for information on type tests and environmental conditions.
General Information
The Ibex-1510 Series EN 50155 Wi-Fi Access Point is designed for use by
installation engineers and users of Westermo products. This guide includes
safety information, regulations, product descriptions, installation
instructions, and technical specifications.
Safety and Regulations
Warning Levels: The product includes warning signs to prevent personal injuries and damages. Different warning levels are used to indicate the potential consequences of not following safety guidelines.
- WARNING: Indicates a potentially hazardous situation that could result in minor or moderate injury and damage to the product.
- CAUTION: Provides information to avoid misuse of the product, confusion, or misunderstanding.
Software Tools
Related software tools for the Ibex-1510 Series EN 50155 Wi-Fi
Access Point can be accessed at
https://www.westermo.com/support/productsupport.
License and Copyright
The product includes software developed by third parties, including Free/Libre
Open Source Software (FLOSS). Specific license terms and copyright information
are included in each software package. Source code is available upon request
with a nominal fee for shipping and media.
FAQ
-
Q: Where can I find more information about Westermo products?
A: More information about Westermo can be found at their official website: www.westermo.com. -
Q: How can I request the source code for the included software?
A: To request the source code, please reach out to your normal sales or support channel. A nominal fee may be charged to cover shipping and media.
General Information
Legal Information
The contents of this document are provided “as is”. Except as required by
applicable law, no warranties of any kind are made in relation to the accuracy
and reliability or contents of this document, either expressed or implied,
including but not limited to the implied warranties of merchantability and
fitness for a particular purpose. Westermo reserves the right to revise this
document or withdraw it at any time without prior notice.
Under no circumstances shall Westermo be responsible for any loss of data or
income or any special, incidental, and consequential or indirect damages
howsoever caused.
More information about Westermo can be found at
www.westermo.com.
About This Guide
This guide is intended for installation engineers and users of Westermo
products.
It includes information on safety and regulations, a product description,
installation instructions and technical specifications.
Software Tools
Related software tools are available at https://www.westermo.com/support
/product-support.
License and Copyright for Included FLOSS
This product includes software developed by third parties, including
Free/Libre Open Source Software (FLOSS). The specific license terms and
copyright associated with the software are included in each software package
respectively. Please visit the product web page for more information.
Upon request, the applicable source code will be provided. A nominal fee may
be charged to cover shipping and media. Please direct any source code request
to your normal sales or support channel.
Safety and Regulations
Warning Levels
Warning signs are provided to prevent personal injuries and/or damages to the
product.
The following levels are used
Safety Information
Before installation:
Read this manual completely and gather all information available on the
product. Make sure it is fully understood. Check that your application does
not exceed the safe operating specifications for the product.
SAFETY DURING INSTALLATION
The product must be installed and operated by qualified service personnel and
installed into an apparatus cabinet or similar, where access is restricted to
service personnel only.
Before energizing and connecting communication cables to the product, ensure a
protective earthing conductor is first connected to the protective earthing
terminal (only valid for metallic housings). Westermo recommends a cross-
sectional area of at least 4 mm2.
Note that this product can be connected to two different power sources.
Upon removal of the product, disconnect the product from the power supply and
all other communication ports before disconnecting the protective earthing
conductor.
HAZARDOUS VOLTAGE
Do not open an energised product. Hazardous voltage may occur when connected
to a power supply.
PROTECTIVE FUSE
The power supply wiring must be sufficiently fused. The fuse must be IEC 60127
certified and rated for T1.6 A and 250 V.
It must be possible to disconnect manually from the power supply. Ensure
compliance to national installation regulations.
This product has no internal fuse and should be connected via an external fuse
for protection.
POWER SUPPLY CONNECTION
There are safety regulations governing the power source that can be used in
conjunction with the product. Refer to chapter Interface Specifications.
RADIO PRODUCTS
Observe the usage limitations of radio products at filling stations, in
chemical plants, in systems with explosives or potentially explosive
locations.
The product may not be used in airplanes. Exercise particular caution near
personal medical aids, such as pacemakers and hearing aids. Never perform work
on the antenna system during a thunderstorm.
To fulfill human safety, a minimum separation distance of 20 cm or more should
be maintained between the antenna of the product and personnel during
operation.
HOT SURFACE
Be aware that the surface of this product may become hot. When it is operated
at high temperatures, the external surface may exceed Touch Temperature Limit
according to the product’s relevant electrical safety standard.
CORROSIVE GASES
If the product is placed in a corrosive environment, it is important that all
unused connector sockets are protected with a suitable plug, in order to avoid
corrosion attacks on the gold plated connector pins.
CABLE TEMPERATURE RATING FOR FIELD TERMINAL WIRES
There may be a requirement on the minimum temperature rating of the cable to
be connected to the field wiring terminals, see chapter Interface
Specifications.
Care Recommendations
Follow the care recommendations below to maintain full operation of the
product and to fulfill the warranty obligations:
- Do not drop, knock or shake the product. Rough handling above the specification may cause damage to internal circuit boards.
- Use a dry or slightly water-damp cloth to clean the product. Do not use harsh chemicals, cleaning solvents or strong detergents.
- Do not paint the product. Paint can clog the product and prevent proper operation.
If the product is used in a manner not according to specification, the
protection provided by the equipment may be impaired.
If the product is not working properly, contact the place of purchase, the
nearest Westermo distributor office or Westermo technical support.
NOTE
Devices not used shall be kept in the factory-sealed moisture barrier bag.
Open, unsealed devices should not be kept unpowered for more than 30 days.
Product Disposal
This symbol means that the product shall not be treated as unsorted municipal
waste when disposing of it. It needs to be handed over to an applicable
collection point for recycling electrical and electronic equipment.
By ensuring the product is disposed of correctly, you will help to reduce
hazardous substances and prevent potential negative consequences to both the
environment and human health, which could be caused by inappropriate disposal.
Figure 1. WEEE symbol for treatment of product disposal
Compliance Information
REGULATORY NOTICE
Any changes or modifications shall be approved by the party responsible for
compliance. If not, users could void the user’s authority to operate the
equipment. Country code and antenna gain need to be set properly for correct
functionality in the installed country.
Agency Approvals and Standards Compliance
Approvals and Standards
Climate| • EN 50155, class OT4 Railway applications – Electronic
equipment used on rolling stock
EMC|
- EN 50155, Railway applications – Electronic equipment used on rolling stock
- EN 50121-3-2, Railway applications – Electromagnetic compatibility, Part 3-2: Rolling stock – Apparatus
- ETSI EN 301 489-1, Electromagnetic compatibility (EMC) and Radio spectrum Matters (ERM) for radio equipment and services – Part 1: Common technical requirements
- ETSI EN 301 489-17, Electromagnetic compatibility (EMC) and Radio spectrum Matters (ERM) for radio equipment – Part 17: Specific conditions for Broadband Data Transmission Systems
Mechanical
(Shock and vibration)
|
- EN 61373, category 1, class B
Insulation (Coordination and test)|
- EN 50155, Railway applications – Electronic equipment used on rolling stock
Radio communication|
- ETSI EN 300 328, Wideband transmission systems; Data transmission equipment operating in the 2.4 GHz ISM band and using wide band modulation techniques
- ETSI EN 301 893, 5 GHz RLAN
- ETSI EN 300 440, 5.8GHz, Short Range Devices
- IEEE802.11, Wireless LAN Medium Access Control (MAC) and Physical Layer (PHY) Specifications
Safety|
- EN/IEC 61010-1, Safety requirements for electrical equipment for measurement, control, and laboratory use
- EN 45545-2, Fire protection on railway vehicles
Simplified Declaration of Conformity
Hereby, Westermo declares that this product is in compliance with applicable
EU directives and UK legislation. The full declaration of conformity and other
detailed information is available at www.westermo.com/support/product-
support.
Figure 2. The European Conformity and the UK Conformity Assessment markings
Product Description
Product Description
The Ibex-1510 is a concurrent dual-band 802.11ax WLAN access point and client
product for onboard and stationary applications. The access points provides
reliable efficient high-speed data transfers, it can be used for passenger
hotspot applications, remote maintenance access, data offloading or as part of
a TCMS network.
Figure 3. Ibex-1510 block
diagram
The Westermo configuration management tool, WeConfig, can be used for
discovery and basic configuration and maintenance. The configuration can be
done locally or remotely via SNMP or via WebGUI/API. The status information is
available in local LED status indicators, and through SNMP or WebGUI/API.
The Ibex-1510 access point is designed to withstand tough onboard
environmental conditions.
Integrating hardware, software and network design support tools, this access
point platform offers advanced capabilities, the lowest total cost of
ownership and will create the most reliable and resilient networks.
The access point is engineered to maintain uninterrupted data communication, even in exceptionally harsh environments. Tested and certified to withstand extreme temperatures, vibrations and shocks, these products only use industrial grade components which contributes towards a market leading mean time between failure (MTBF), maximized service life, and reduced operational and life cycle costs.
Available models
Art. no. | Model | Region | PoE Port | Rated voltage |
---|---|---|---|---|
3628-15101 | Ibex-1510-T2G2.5 EU | Europe | X1 | 24-110 VDC |
3628-15102 | Ibex-1510-T2G2.5 NAa. | North America | X1 | 24-110 VDC |
3628-15111 | Ibex-1510-T2G2.5-PoE EU | Europe | X1 | – |
3628-15112 | Ibex-1510-T2G2.5-PoE NAa. | North America | X1 | – |
FCC approval pending
Table 2. List of available models
Hardware Overview
Frontside Overview
No. | Description | No. | Description |
---|---|---|---|
1 | 2.5 Gigabit Ethernet port X2 | 2 | 2.5 Gigabit Ethernet port X1 (PoE) |
3 | Power input DCa. | 4 | Protective earth terminal |
5 | Frontside label | 6 | Warning symbol for surface temperatures above +60°C |
7 | Antenna ports A1 – A2 (2.4 GHz / 5 GHz) | 8 | Product family label |
Table 3. Location of interface ports
Interface Ports View
No. | Description | No. | Description |
---|---|---|---|
1 | Power input DCa. | 2 | Protective earth terminal |
3 | Ethernet 2.5GBase-T ports (X1 PoE) | 4 | Ethernet 2.5GBase-T port X2 |
5 | Antennas A1 – A2, 2.4 GHz / 5 GHz |
DC power supply not included in “PoE only” product variants
Table 4. Interface ports view
Connector Information
Power Input Connection
The Ibex-1510 product variants can be equipped with a DC dual input power port
that meets the following specifications. Refer also to the LED status
indicators.
Marking| Position| Direction| Description|
---|---|---|---|---
DC| 1| +DC1| Positive terminal|
2| +DC2| Positive terminal
3| -DC| Negative terminal
4| -DC| Negative terminal
Housing| Shield| Chassis of product (ground)
Table 5. M12 A-coded 4-pin male power connector according to IEC 61076-2-101
Ethernet Ports
The product includes two Ethernet ports X1 and X2 which supports auto-
negotiated 10 Mbit/s, 100 Mbit/s, 1000 Mbit/s and 2500 Mbit/s operation.
Automatic MDI/MDIX crossover is supported for 10BASE-T, 100BASE-T, 1000BASE-T
and 2500BASE-T operation.
Marking| Position| Direction| Description|
---|---|---|---|---
X1/X2| 1| In/Out| DA+|
2| In/Out| DA-
3| In/Out| DB+
4| In/Out| DB-
5| In/Out| DD+
6| In/Out| DD-
7| In/Out| DC-
8| In/Out| DC+
Housing| Shield| Chassis of product (ground)
Table 6. M12 X-coded 8-pin female Ethernet connector according to IEC 61076-2-109
Position | Device mode A | Device mode B |
---|---|---|
1 | +DC | |
2 | +DC | |
3 | -DC | |
4 | -DC | |
5 | -DC | |
6 | -DC | |
7 | +DC | |
8 | +DC |
Table 7. Ethernet PoE connection on X1
NOTE
If the Ethernet function is not used, the protective dust cap which is part of
the delivery must be closed to protect the interface from water or dust
ingress.
Antenna Ports
The antenna connectors are identified on the product with A1 and A2.
A1 and A2 are used for WLAN communication. At least A1 must be connected to an
external WLAN antenna. The antenna configuration is made through the software
interface.
NOTICE
Any unused antenna ports must be properly terminated with 50 Ohm, otherwise
the product might be damaged when power is applied to a non-terminated antenna
port.
NOTE
To ensure specified IP protection, suitable QMA connectors/cables and
terminations must be used.
LED Indicators
Figure 4. LED indicators
LED | Description |
---|---|
DC | Power status |
ON | Operation status |
X1 | Ethernet status for X1 port |
X2 | Ethernet status for X2 port |
Table 8. LED indicators
NOTE
The power status LED is green if both input power sources are available. The
LED lights up red if only one power input source is provided.
NOTE
Refer to management guide for detailed LED status indication.
Dimensions
Dimensions are stated in mm and are regardless of variants.
Figure 5. Dimensional drawing
Installation
Mounting
The product is fixed with the four fixing points located at the corners of the
product. M6 screws are used for the fixation of the product. The screws are
tightened with min. 3.0 Nm (fixing screw ISO 898/1, quality class 8.8).
NOTICE
All four specified fixing points must be used for fixing. The installation
surface should be flat to have all fixing points connected to the surface.
NOTE
For indoor installation, consider additional protection against dust to ensure
proper heat dissipation.
NOTE
For outdoor installation, consider additional protection against sun
radiation, dust and dirt to optimize ambient temperature range.
NOTE
Unused connectors must be covered by a protective cap (delivered with the
product), tightened to the specified torque in order to fulfill the specified
ingress protection code.
Factory Reset
To reset the product into factory default settings, a reset adapter is needed
which is plugged into one of the Ethernet ports X1 or X2 during startup.
Art. no. | Description |
---|---|
3623-0799 | Factory Reset Plug, X-coded |
Factory reset procedure
- Plug the factory reset adapter to one of the Ethernet interfaces.
- Power the product.
- Wait until factory reset adapter is detected. This is indicated by a solid RED ON LED.
- Remove factory reset adapter within 15 seconds.
- Successful initiation of the factory reset is indicated by blinking RED ON LED.
Earth connection
For correct function, the earth connection at the grounding point needs to be
properly connected to a solid ground. An M6 grounding screw at the housing is
used for grounding. A short wire with a cross section of at least 4 mm2 shall
be used. The grounding wire is set below the rip-lock washer. The nut is fixed
for good reliable grounding contact. The tightening torque of the grounding
nut should not exceed 10 Nm.
NOTICE
Do not use equipment without protective earth connection.
Connection of Cables
Recommended tightening torque for the M12 connectors is 0.6 Nm. All M12
connections are screw connections.
When connecting the power cable, ensure that the pins are connected correctly
before tightening the power cable to the unit.
NOTE
This product has no replaceable fuse and should be connected via an external
fuse for protection.
Cooling
This product uses convection cooling. Make sure that it is installed so that
the ambient temperature is within the specified temperature range, e.g. by
avoiding obstruction of the airflow around the product.
It is recommended to install the product in areas where the natural convection
airflow is not blocked and that there is enough spacing around the product.
When operating the product at high ambient temperatures, it is recommended to
mount the product to a metallic base plate to improve the heat dissipation.
The base plate increases the surface to spread the heat.
NOTICE
Limited air flow is rising the product temperature and may lower the upper
limit of the operating temperature range.
NOTICE
Temperature is dependent on the operational parameters, like RF output power,
amount of traffic.
NOTICE
This product has integrated temperature sensors for monitoring the internal
device temperatures. If temperature limits are exceeded, alarms are sent
through the SW interface.
NOTICE
The operating conditions shall be ensured so that the normal operation does
not cause temperature alarms. Improve installation conditions or RF parameters
in case of any temperature alarms.
Replacement of Product
The device cannot be repaired. In case of a malfunction, it must be replaced.
Disconnect all cables and unscrew the product from the wall. Mount the
replacement product and reconnect all cables, observing the instructions in
Connection of Cables.
MTTR (Mean Time To Repair), i.e. time for replacement of product is: < 10
minutes.
HOT SURFACE
Be aware that the surface of this product may become hot. When it is operated
at high temperatures, the external surface may exceed Touch Temperature Limit
according to the product’s relevant electrical safety standard.
Specifications
Interface Specifications
DC, Power port
Connector| M12 A-coded male
Rated voltage| 24 to 110 VDC, Class 1
Operating voltage| 16.8 to 143 VDC
Rated power| 14 W
Rated frequency| DC
Startup current| 2 x rated current
Polarity| Reverse polarity protected
Redundant power input| Dual input port
Conductor cross section (flexible)| > 0.5 mm² (AWG 20)
Cable temperature rating| -40 to +70°C
Shielded cable| Not required
PoE (on X1)
Connector| M12 X-coded female
Device mode| A and B
Rated voltage| 48 VDC
Operating voltage| 37 to 57 VDC
Power classification| Class 4
Ethernet
Connector| M12 X-coded female
Electrical specification| IEEE std 802.3
Data rate| 10 Mbit/s, 100 Mbit/s, 1000 Mbit/s, 2500 Mbit/s manual or
auto
Duplex| Full or half, manual or auto
Transmission range| Up to 100 m with CAT5e cable or better
Cabling| Shielded cable CAT5e or better is recommended
Conductive chassis| Yes
NOTE
The product is to be connected to internal Ethernet networks without exiting a
facility and being subjected to TNVs.
NOTICE
To avoid damages on the Ethernet interfaces, ensure that the far end side of
the Ethernet cable shield itself is connected to protective earth.
Antenna WLAN (A1 to A2)
Connector| QMA female
Direction| Transmit and receive
Cabling| 50 Ohm coaxial cable and WLAN antenna required
Conductive chassis| Yes
WLAN interfaces| 2×2 MU-MIMO for 2.4 GHz and 5 GHz, 802.11a/g/n/ac/ax
Access Point
WLAN frequency bands| 2.400 to 2.4835 GHz
5.150 to 5.350 GHz, 5.470 to 5.725 GHz, 5.725 to 5.850 GHz
Transmitting power a.| 2.4 GHz and 5 GHz: up to 25 dBm, per port: 22 dBm
.Max. conducted transmit power within the whole frequency range and for all data rates
NOTICE
Depending on the installation country there are frequency/band restrictions
and output power limitations.
NOTICE
Unused antenna port must be terminated with 50 Ohm terminations.
NOTICE
To avoid damages on the antenna interfaces, ensure that the far end side of
the antenna cable and/or the antenna itself is connected to protective earth.
Type Tests and Environmental Conditions
Environmental phenomena| Basic standard| Description| Test
levels
---|---|---|---
ESD| EN 61000-4-2| Enclosure| Contact: ±6 kV Air: ±8 kV
Fast transients| EN 61000-4-4| DC power port| ± 2 kV, direct coupling
Ethernet ports| ± 2 kV, capacitive coupling clamp
Antenna ports
Surge| EN 61000-4-5| DC power port| L-E: ± 1 kV, 12 Ω, 9 µF, 1.2/50 µs
L-E: ± 2 kV, 42 Ω, 0.5 µF, 1.2/50 µs L-L: ± 1 kV, 12 Ω, 9 µF, 1.2/50 µs L-L: ±
2 kV, 42 Ω, 0.5 µF, 1.2/50 µs
Ethernet ports| Shield-E: ± 2 kV, 2 Ω, 1.2/50 µs
Antenna ports
Power frequency magnetic field| EN 61000-4-8| Enclosure| 300 A/m
continues, DC, 16.7 Hz, 50 Hz,
60 Hz
Radiated RF immunity| EN 61000-4-3| Enclosure| 20 V/m, 80% AM (1kHz) at 80 MHz to 6 GHz
30 V/m, PM 200 Hz square at 380 MHz to 385 MHz
30 V/m, PM 200 Hz square at 390 MHz to 395 MHz
Conducted RF immunity| EN 61000-4-6| DC power port| 10 V, 80% AM (1 kHz) from 0.15 to 80
MHz
Ethernet ports
Antenna ports
Radiated RF emission| EN 55032| Enclosure| Class A
Conducted RF emission| EN 55032| DC power port| Class A
Ethernet ports
Insulation resistance| EN 50155| Power port (DC) to all other ports| >
100 MOhm
Dielectric strength| EN 50155| Power port (DC) to all other ports| 2200
VDC, 60 s
Table 9. EMC and electrical conditions
Environmental phenomena| Basic standard| Description| Test
levels
---|---|---|---
Temperatures| EN 60068-2-1
EN 60068-2-2
EN 60068-2-14
| Operational| -40 to +70°C (-40 to +158°F)a.
Storage and transport| -55 to +85°C (-67 to +185°F)
Humidity| EN 60068-2-30| Operational| 5-95 % relative humidity
Storage and transport
Altitude| | Operational| 3000 m
MTBF| IEC TR 62380| | 424,000 hours
538,000 hours (PoE product variant only)
Vibration| EN 60068-2-64
(random)
| Operational, endurance test| 11.44 m/s2 random, 5 to 150 Hz, 3 x 5 h
Shock b.| EN 60068-2-27| Operational| 100 m/s2, 30 ms, 3 x 6 shocks (half
sine)
MIL STD 810, M516.7| 20 g, 11 ms, 3 x 6 shocks (saw tooth)
Weight| | | 1450 gr
Degree of protection| EN 60529| Enclosure| IP66c.
Cooling| | | Convection
Pollution degree| EN 61010-1| | PD2
Conformal coating type| IPC-A-610| Electronic modules| AR (Acrylic)
- Refer to “Safety and Regulations” chapter regarding touch temperature
- The power and Ethernet cables need to be fastened 200 mm or closer to the unit. The same recommendation applies to the Antenna cables.
- Provided all connectors are connected with IP66 cabling or fitted with protective caps (delivered with the unit) and tightened to the specified torque
Table 10. Environmental and mechanical conditions
Abbreviations and Terms
Abbreviation | Description |
---|---|
AM | Amplitude Modulation |
AREMA | American Railway Engineering and Maintenance-of-Way Association |
AWG | American Wire Gauge |
CAT5e | Category 5 Enhanced Cable |
CE | Conformité Européenne |
CPU | Central Processing Unit |
DC | Direct Current |
EMC | Electromagnetic Compatibility |
EN | European Standard |
ERR | Error |
ESD | Electro Static Discharge |
ETSI | European Telecommunications Standards Institute |
FCC | Federal Communication Commission |
FLOSS | Free/Libre Open Source Software |
IEC | International Engineering Consortium |
IC | Industry Canada |
ID | Identification |
I/O | Input / Output |
IP | Ingress Protection |
ISO | International Standardization Organisation |
LAN | Local Area Network |
LED | Light Emitting Diode |
MIMO | Multiple Input, Multiple Output |
MTBF | Mean Time between Failure |
MTTR | Mean Time to Repair |
OPR | Operation |
QR | Quick Response |
RF | Radio Frequency |
SN | Serial Number |
SNMP | Simple Network Management Protocol |
TNV | Telephone Network Voltage |
WebAPI | Web Application Programming Interface |
Abbreviation | Description |
--- | --- |
WebGUI | Web Graphical User Interface |
WeConfig | Westermo Configuration Tool |
WEEE | Waste Electrical and Electronics Equipment |
Wi-Fi | Wireless Fidelity |
WLAN | Wireless Local Area Network |
Table 11. Abbreviations and terms
Revision Notes
Revision | Date | Change description |
---|---|---|
Rev. A | 2024-02 | First revision |
Westermo • Metallverksgatan 6, SE-721 30 Västerås, Sweden
- Tel +46 16 42 80 00 Fax +46 16 42 80 01
- E-mail: info@westermo.com
- www.westermo.com
6628-2220 REV. A 2024 02 @ Westermo Network Technologies AB, Sweden
References
- Westermo ᐅ Robust and Secure Industrial Networking Solutions
- Product support, user guides and software downloads ᐅ Westermo
- Product support, user guides and software downloads ᐅ Westermo
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>