westermo Viper-8 Series 50155 Managed Gigabit Routing Switch
General Information
Legal Information
The contents of this document are provided “as is”. Except as required by
applicable law, no warranties of any kind are made in relation to the accuracy
and reliability or contents of this document, either expressed or implied,
including but not limited to the implied warranties of merchantability and
fitness for a particular purpose. Westermo reserves the right to revise this
document or withdraw it at any time without prior notice. Under no
circumstances shall Westermo be responsible for any loss of data or income or
any special, incidental, and consequential or indirect damages howsoever
caused. More information about Westermo can be found at
www.westermo.com.
About This Guide
This guide is intended for installation engineers and users of the Westermo
products. It includes information on safety and regulations, a product
description, installation instructions and technical specifications.
Software Tools
Related software tools are available at https://www.westermo.com/support
/product-support.
License and Copyright for Included FLOSS
This product includes software developed by third parties, including
Free/Libre Open Source Software (FLOSS). The specific license terms and
copyright associated with the software are included in each software package
respectively. Please visit the product web page for more information. Upon
request, the applicable source code will be provided. A nominal fee may be
charged to cover shipping and media. Please direct any source code request to
your normal sales or support channel.
WeOS
This product runs WeOS 5 (Westermo Operating System). Instructions for quick
start, configuration and factory reset are found in the WeOS user
documentation at www.westermo.com.
Safety Information
Before installation:
Read this manual completely and gather all information available on the product. Make sure it is fully understood. Check that your application does not exceed the safe operating specifications for the product.
SAFETY DURING INSTALLATION
The product must be installed and operated by qualified service personnel and
installed into an apparatus cabinet or similar, where access is restricted to
service personnel only.
Refer to chapter Compliance Information to see the required level of qualified
service personnel according to safety standards. During installation, ensure a
protective earthing conductor is first connected to the protective earthing
terminal (only valid for metallic housings). Westermo recommends a cross-
sectional area of at least 4 mm2. Upon removal of the product, ensure that the
protective earthing conductor is disconnected last.
HAZARDOUS VOLTAGE
Do not open an energized product. Hazardous voltage may occur when connected to a power supply.
PROTECTIVE FUSE
The power supply wiring must be sufficiently fused. The fuse must be IEC 60127 certified and rated for T1.6 A and 250 V. It must be possible to disconnect manually from the power supply. Ensure compliance to national installation regulations. This product has no internal fuse and should be connected via an external fuse for protection.
REDUCE THE RISK OF FIRE
To reduce the risk of fire, use only telecommunication line cords with a cable diameter of AWG 26 or larger. Regarding power cable dimensions, see chapter Interface Specifications.
CABLE TEMPERATURE RATING FOR FIELD TERMINAL WIRES
There may be a requirement on the minimum temperature rating of the cable to be connected to the field wiring terminals, see chapter Interface Specifications.
ELECTROSTATIC DISCHARGE (ESD)
Prevent electrostatic discharge damage to internal electronic parts by discharging your body to a grounding point (e.g. use a wrist strap).
HOT SURFACE
Be aware that the surface of this product may become hot. When it is operated at high temperatures, the external surface may exceed Touch Temperature Limit according to the product’s relevant electrical safety standard.
Care Recommendations
Follow the care recommendations below to maintain full operation of the product and to fulfill the warranty obligations:
- Do not drop, knock or shake the product. Rough handling above the specification may cause damage to internal circuit boards.
- Use a dry or slightly water-damp cloth to clean the product. Do not use harsh chemicals, cleaning solvents or strong detergents.
- Do not paint the product. Paint can clog the product and prevent proper operation.
If the product is used in a manner not according to specification, the protection provided by the equipment may be impaired. If the product is not working properly, contact the place of purchase, the nearest Westermo distributor office or Westermo technical support.
Product Disposal
This symbol means that the product shall not be treated as unsorted municipal waste when disposing of it. It needs to be handed over to an applicable collection point for recycling electrical and electronic equipment. By ensuring the product is disposed of correctly, you will help to reduce hazardous substances and prevent potential negative consequences to both the environment and human health, which could be caused by inappropriate disposal.
Compliance Information
Agency Approvals and Standards Compliance
Type | Approval/Compliance |
---|---|
Climate | • EN 50155 class OT4 / IEC 60571 class TX, Railway applications – |
Electronic equipment used on rolling stock
• IEEE 1478 class 1, condition E4 (incl Salt Mist), Environmental conditions for transit rail car electronic equipment
EMC| • EN/IEC 61000-6-2, Immunity industrial environments
• EN/IEC 61000-6-4, Emission industrial environments
• EN 50121-4/IEC 62236-4, Railway signaling and telecommunications apparatus
• EN 50121-3-2/IEC 62236-3-2 Railway applications – Rolling stock – apparatus
• Tested and verified for Class S1, DB EMC Regulation 06, Commodity team Radio compatibility in VDB Rev 1.0 (Shunting Radio)
• Tested and verified for FCC part 15b class A (CFR 47)
Mechanical (Shock and vibration)| • EN 61373 category 1, class A and B
• IEEE 1478 class 1, condition E4, including shock tests 10 g/30 ms and 20 g/11 ms in all directions
Insulation (Coordination and test)| • EN 50124-1, Railway applications – Insulation coordination
• EN 50155/IEC 60571, Railway applications – Electronic equipment used on rolling stock
Fire protection| • EN 45545-2, Fire protection on railway vehicles
• NFPA 130, Fire protection for fixed guideway transit and passenger rail system
Software| • EN 50657:2017 Software Onboard Rolling Stock (Basic Integrity)
Safety| • EN/IEC/UL 61010-1, -2-201, Safety requirements for electrical
equipment for measurement, control, and laboratory use
EN/IEC/UL 61010-2-201 Notice
This product has been tested and found compliant to EN/IEC/UL 61010-2-201,
Safety requirements for electrical equipment for measurement, control, and
laboratory use. In accordance with the definitions of the standard, this
product shall be handled by skilled service personnel.
FCC Part 15.105 Class A Notice
This product has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the product is operated in a commercial environment. This product generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the user manual, may cause harmful interference to radio communications. Operation of this product in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at the users own expense.
Simplified Declaration of Conformity
Hereby, Westermo declares that this product is in compliance with applicable EU directives and UK legislation. The full declaration of conformity and other detailed information is available at www.westermo.com/support/product- support.
Product Description
The Viper-8 series is a managed backbone routing switch optimized for the needs of the railway rolling stock market. Gbps ports cope with high bandwidth backbone, consist ring and end devices. The product is designed to withstand the tough environment on-board trains, exposing the switch to constant vibration, extreme temperatures, humidity and a demanding electrical environment. A GORE-TEX® membrane prevents internal condensation. Threading integrated in chassis provides for additional vibration resistance. High-level isolation between all interfaces enables direct connectivity to vehicle auxiliary power and protects against overvoltage and flashover. IP67 protection prevents ingress of water and dust. An overall optimized design results in an extremely compact package in combination with very high MTBF for easy integration and low lifecycle cost. Thorough type testing at independent ISO/IEC 17025 and ILAC MRA certified labs, accredited to a wide range of standards, show that the Viper series fulfills EN 50155 and other requirements. The state-of-the-art Westermo production facility ensures the quality of each individual unit, e.g. through temperature cycling burn-in testing. The WeOS operating system offers an extensive suite of IP networking features for resilient and flexible networks, e.g. the FRNT ring protocol with very fast failover. The powerful layer 3 routing capability ensures communication between the backbone and consist networks and offers full support for IEC 61375, including TTDP network inauguration and TRDP real-time data protocol. The backup device accessory matches the Viper in robustness and offers easy configuration update and backup.
Available Models
Art. no. | Model | Software | Gbps ports |
---|---|---|---|
3635-2210 | Viper-108-T8G | L2 | 8 |
3635-2220 | Viper-208-T8G | L3 | 8 |
Hardware Overview
No. | Description | No. | Description |
---|---|---|---|
1 | LED indicator | 2 | Gbps port (8 pcs) |
3 | GORE-TEX ventilation membrane on the rear side | 4 | Power connection |
5 | Console port | 6 | Protective earth connection |
7 | USB port |
Connector Pinout
LED Indicators
LED | Status | Description |
---|---|---|
ON | OFF | Product has no power |
GREEN | All OK, no alarm condition | |
RED | Alarm condition, or until product has started up. (Alarm conditions are |
configurable, see WeOS5 User Guide )
RSTP| OFF| RSTP disabled
GREEN| RSTP enabled
BLINK| Product selected as RSTP/STP root switch
FRNT| OFF| FRNT disabled
GREEN| FRNT OK
RED| FRNT error
FLASH| Product configured as FRNT focal point
DC| OFF| Product has no power
GREEN| Power OK on DC1 and DC2
RED| Power failure on DC1 or DC2
X1 to X8| OFF| No link
GREEN| Link established
GREEN FLASH| Data traffic indication
YELLOW| Port alarm, or port is set in blocking state by link redundancy
protocol
Dimensions
Dimensions are stated in mm and applies to both models.
Installation
Wall Mounting
The product can be wall-mounted vertically or horizontally. There are four pieces of 7 mm bores for this. Use four M5, M6 or 1/4″ screws with 12 mm washers on a flat and stable surface.
Protective Earth Connection
For correct function, the earth connection needs to be properly connected to a designated PE rail. See the figure below. Torx: T25 and torque: 3.2 Nm.
Connection of Cables
Recommended tightening torque for the M12 connectors is 0.6 Nm. All M12 connections are screw connections. When connecting the power cable, ensure that the pins are connected correctly before tightening the power cable to the unit.
Cooling
This product relies on convection cooling. Make sure that it is installed so that the ambient temperature is within the specified temperature range. Avoid obstruction of the airflow around the product.
Replacement of Product
Disconnect all cables and unscrew the product from the wall. Mount the replacement product and reconnect all cables, observing the instructions in Connection of Cables [15]. For easy replication of the configuration of the original product, it is recommended to have the Westermo USB plug permanently connected to the USB port and move it over to the replacement product before it is powered up. MTTR (Mean Time To Repair), i.e. time for replacement of product is: < 8 minutes.
EN 45545-2 Mounting Notes
Two products can be mounted together and as a single interior non-listed group in the sense of EN 45545-2 definitions. For multiple product, the spacing requirements for interior non-listed groups must be met.
Specifications
Interface Specifications
DC, Power port
Rated voltage| 24 to 110 VDC
Operating voltage| 16.8 to 143 VDC (14.4 VDC for 100 ms and 154 VDC
for 1 s)
Rated current| Max 460 mA at 24 VDC, max 110 mA at 110 VDC
Rated frequency| DC
Inrush current| 80 mA²s at 24 VDC, 140 mA²s at 110 VDC
Startup current| Max 560 mA at 16.8 VDC
Polarity| Reverse polarity protected
Redundant power input| Yes
Isolation| To all other ports
Connector| 4-pin, male, M12 screw connection, A-coded, recommended
Westermo cables:
3146-1106 for 1.5 m
3146-1107 for 5 m
Cable size| M12, recommended power cable area 0.5 mm² (minimum 0.25 mm²), which correlates to AWG 21 or larger
Cable dimensions depend on choice of M12 connector
Cable temperature rating| For minimum temperature rating of the cable to
be connected to the field wiring terminals: -40 to +70 °C
Circuit type| Secondary circuit hazardous voltage, OVC II
Gbps ports
Electrical specification| IEEE std 802.3
Data rate| 10 Mbps, 100 Mbps, 1 Gbps, manual or auto
Duplex| Full or half, manual or auto
Transmission range| Up to 150 m with CAT5e cable or better
Isolation| To all other ports
Connector| 8-pin, female, M12 screw connection, X-coded
Cabling| Shielded cable CAT5e or better is recommended
Conductive chassis| Yes
FRNT reconfiguration time| Typically below 20 ms
Circuit type| TNV-1
USB port
Electrical specification| USB 2.0 host interface
Data rate| Up to 480 Mbps (high-speed mode)
Maximum supply current| 500 mA
Isolation| To all Ethernet and DC ports
No isolation to CON or protective earth
Connector| 5-pin, female, M12 screw connection, A-coded, recommended Westermo USB plug
3641-0190
Circuit type| SELV
Console port
Electrical specification| RS-232
Data rate| 115.2 kbit/s
Data format| 8 data bits, no parity, 1 stop bit, no flow control
Isolation| To all Ethernet and DC ports
No isolation to USB or protective earth
Connector| 5-pin, female, M12 screw connection, B-coded, recommended Westermo cables:
1211-2215 (serial port) or 1211-4073 (USB)
Circuit type| SELV
Type Tests and Environmental Conditions
Environmental phenomena| Basic standard| Description|
Test levels
---|---|---|---
ESD| EN 61000-4-2| Enclosure| Contact: ±6 kV Air: ±8 kV
Fast transients| EN 61000-4-4| Power port| ± 2 kV
Signal ports
Earth port
Surge| EN 61000-4-5| Power port| L-E: ± 2 kV, 42 Ω, 0.5 µF, 1.2/50 µs
L-E: ± 0.5 kV, 12 Ω, 9 µF, 1.2/50 µs L-L: ± 2 kV, 42 Ω, 0.5 µF, 1.2/50 µs L-L:
± 0.5 kV, 2 Ω, 18 µF, 1.2/50 µs
Ethernet port| L-E: ± 2 kV, 2 Ω
Radiated RF immunity| EN 61000-4-3| Enclosure| 20 V/m at (80 MHz
to 2 GHz)
10 V/m at (2-6 GHz)
1 kHz sine, 80% AM
Conducted RF immunity| EN 61000-4-6| Power port| 10 V, 80% AM, 1
kHz; (0.15-80) MHz
Ethernet ports
Earth port
Radiated RF emission| CISPR 16-2-3| Enclosure| EN 61000-6-4 (30-6000
MHz)
ANSI C63,4
(FCC Part 15b)
| Class A
Conducted RF emission| CISPR 16-2-1| Power port| EN 61000-6-4
CISPR 32| Ethernet ports| EN 61000-6-3
Insulation resistance| EN 50155| All ports| ≥20 MΩ at 500 VDC
Dielectric strength| EN 50155| Power port to all other ports| 2250
VDC, 1 min
Ethernet ports to all other ports| 2250 VDC, 1 mina
Environmental phenomena| Basic standard| Description|
Test levels
---|---|---|---
Temperatures| EN 60068-2-1
EN 60068-2-2
| Operational| -40 to +70°C (-40 to +158°F)ab
Storage and transport| -55 to +85°C (-67 to +185°F)
Humidity| EN 60068-2-30| Operational| 5-95% relative humidity
Storage and transport
Altitude| | Operational| 2000 m/80 kPa
Service life| | Operational| 20 years according to IEC/TR 62380
MTBF| 1: MIL- HDBK-217F- N2, GB,
+25°C/ +77°F 2: IEC 62380
| | 1: 659,000 hrs, 2: 603,000 hrs
Vibration| IEC 60068-2-6
(sine)
| Operational| 5 sweeps cycles:
7.5 mm 5-8 Hz 2g, 8-500 Hz
IEC
60068-2-64
(random)
| Non-operational long-life simulation| 11.44 m/s² RMS 5-150 Hz, 5 hours
20 m/s² RMS 5-150 Hz, 30 min operational
Shock| IEC
60068-2-27
| Operational| 10 g, 30 ms, half-sine
20 g, 11 ms, saw tooth
Weight| | | 1.45 kg
Degree of protection| IEC 60529| Enclosure| IP67, no ingress of
dust and protection against water immersion up to 1 m. Also passes IP66
tests.c
Cooling| | | Convection
Overvoltage category| EN/IEC/UL 61010-1| | OVC II
Pollution degree| EN/IEC/UL 61010-1| | PD3 macro environment and PD2
micro environment
EN 50124-1| | PD2
Location| EN/IEC/UL 61010-1| | Outdoor, wet locations
IEEE 1478| | Class 1, condition E4. Indoor
Revision Notes
Revision | Date | Change description |
---|---|---|
Rev. F | 2022-06 | 1.3 Software Tools; link updated, 3.3 Hardware Overview; |
illustration updated, 3.6 Dimensions; illustration updated, 4.1 Wall Mounting;
illustration updated, 4.2 Protective Earth Connection; torque added and
illustration updated.
Rev. E| 2022-03| 3.4 Connector Pinout; Faulty footnote at Gbps connector
removed.
Rev. D| 2022-01| 2.2 Safety Information updated (Warning – Safety during
installation), 2.5.2 EN/IEC/UL 61010-2-210 Notice added, 5.2 Type Tests and
Environmental Conditions updated (UL added to EN/IEC 61010-1)
Rev. C| 2021-12| 5.1 Interface Specification updated (DC Power port; operating
voltage)
Rev. B| 2021-12| E-mark removed from 2.5.1 Agency Approvals and Standards
Compliance
Rev. A| 2021-10| First version
References
- Westermo ᐅ Robust and Secure Industrial Networking Solutions
- Product support, user guides and software downloads ᐅ Westermo
- Product support, user guides and software downloads ᐅ Westermo
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>