MICROCHIP PolarFire and PolarFire SoC DRI Icicle Kit User Guide
- June 10, 2024
- MICROCHIP
Table of Contents
Polarize® and PolarFire SoC DRI
User Guide
Introduction
Microchip’s PolarFire FPGAs are the fifth-generation family of non-volatile
FPGA devices, built on state-of-the-art 28 nm non-volatile process technology.
PolarFire FPGAs deliver the lowest power at mid-range densities. PolarFire
FPGAs lower the cost of mid-range FPGAs by integrating the industry’s lowest
power FPGA fabric, lowest power 12.7 Gbps transceiver lane, built-in low power
dual PCI Express Gen2 (EP/RP), and, on select data security (S) devices, an
integrated low-power crypto co-processor.
Microchip’s PolarFire SoC FPGAs are the fifth-generation family of non-
volatile SoC FPGA devices, built on state of-the-art 28 nm non-volatile
process technology. The PolarFire SoC family offers industry’s first RISC-V
based SoC FPGAs capable of running Linux. The PolarFire SoC family combines a
powerful 64-bit 5x core RISC-V Microprocessor Sub-System (MSS), based on
SiTime’s U54-MC family, with the PolarFire FPGA fabric in a single device.
Dynamic Reconfiguration Interface (DRI) is an embedded bus within PolarFire
and PolarFire SoC FPGAs. DRI is an APB target interconnect providing global
access to the following embedded blocks:
- Transceiver lanes
- Transmit PLLs
- PLLs/DLLs (Clock conditioning circuitry or CCCs)
DRI allows modification of these embedded blocks at power-up and during
operation. The embedded DRI bus provides dedicated connectivity and register
mapped addressing to all the features as APB target peripherals. The DRI
connectivity is a fixed dedicated resource that does not require any fabric
logic or routing resources. Each transceiver and CCC supports a DRI, which can
be enabled to configure its parameters without reprogramming the device. The
transceiver, PCIESS, and CCC reconfiguration is controlled by volatile
configuration registers that are loaded with values from the flash
configuration bits at power-up. It is recommended to carefully use DRI because
changing the factory or initialization settings can cause undesired results.
Note: DRI is not available to the user logic, when SmartDebug is being
used for debugging.
The following table summarizes DRI access in both PolarFire and PolarFire SoC
FPGAs.
Table 1.PolarFire and PolarFire SoC DRI
DRI Access | PolarFire | PolarFire SoC | Description |
---|---|---|---|
PF_DRI SgCore IP | ✓ | ✓ | The PF_DRI IP enables user access to the embedded APB |
target bus which provides a mirrored initiator APB target interface to the
FPGA fabric. This IP can be used in both PolarFire and PolarFire SoC FPGAs. In
PolarFire designs, the APB initiator can be implemented with the Mi-V soft
processor IP or the CoreABC IP for controlling and accessing the DRI target
peripherals. In PolarFire SoC designs, the APB initiator can be implemented
with the PolarFire SoC MSS, the Mi-V soft processor IP, or the
Core ABC IP for controlling and accessing
the DRI target peripherals.
This user guide describes how DRI is used in PolarFire and PolarFire SoC
FPGAs.
Note: AXI and APB protocol standards use the terminology “Manager” and
“Subordinate”. The equivalent Microchip terminology used in this document is
“Initiator” and “Target” respectively.
References
• For detailed information about the PolarFire register map, see PolarFire
Device Register Map.
• For detailed information about the PolarFire SoC register map, see
PolarFire SoC Device Register Map.
• For more information about PolarFire SoC MSS, see PolarFire SoC FPGA MSS
Technical Reference
Manual.
• For more information about configuring PolarFire SoC MSS, see PolarFire SoC
Standalone MSS Configurator
User Guide available at www.microsemi.com/product-directory/soc-design-
tools/5587-pfsoc-mss-configuratortool#documents.
PolarFire FPGA DRI Use Model
The following figure shows the high-level block diagram of the DRI implementation in PolarFire devices.
Figure 1-1. High-level Block Diagram of DRI Implementation
For information about the dynamic reconfiguration of transceiver and CCC using the PF_DRI IP, see AC475: PolarFire FPGA Dynamic Reconfiguration Interface Application Note.
PolarFire SoC FPGA DRI Block Diagram
In PolarFire SoC FPGAs, MSS accesses DRI via FIC_3 which is an APB interface.
The following block diagram shows how DRI is accessed using the PF_DRI IP from
the fabric in PolarFire SoC FPGAs.
Figure 2-1. DRI Accessed Using PF_DRI IP from Fabric
One of the processor cores is used to update the DRI registers of transceiver,
CCC, and the TX PLL blocks via the FIC3 interface. For more information about
configuring PolarFire SoC MSS, see PolarFire SoC Standalone MSS Configurator
User
Guide.
For detailed information about the PolarFire SoC register map, see PolarFire
SoC Device Register
Map.
For more information about updating the CCC PLL outputs dynamically using the
PF_DRI IP, see PolarFire SoC Bare Metal DRI Application.
PF_DRI Score IP
PolarFire Dynamic Reconfiguration Interface (PF_DRI) Score IP is available in
the Catalog under Peripherals as shown in the following figure.
Figure 3-1. The DRI IP with APB Interface
The following table lists the general ports of the PF_DRI Score.
Table 3-1. PF_DRI Ports
Port Name | Direction | Width | Description |
---|---|---|---|
PCLK | Input | 1 | Input clock source to DRI. This clock can be sourced from a |
CCC or
an external oscillator.
All transfers on the APB bus are clocked with respect to the rising edge of
PCLK.
PSTRB[3:0]| Input| 4| (Active-High) There is one write strobe for each byte of
the write data
(PWDATA 32-bit or 4 bytes). PSTRB signal indicates the byte lanes to be
updated during a write transfer.
PRESETN| Input| 1| (Active-Low) The APB Reset signal from the initiator.
PINTERRUPT| Output| 1| (Active-High) Interrupt can be handled by a soft
processor or can be handled by other user logic in the fabric. DRI_INTERRUPT
is the source of the INTERRUPT.
PTIMEOUT| Output| 1| (Active-High) Indicates to the fabric that the bus timed
out (no response received). Time-out can occur when accessing a target that is
not ready.
BUSERROR| Output| 1| (Active-High) Indicates to the fabric that a bus error
was detected.
Once asserted, this error signal stays active until PRESETN is asserted. Bus
error can occur if accessing locked or non-existent targets.
APBS (APB Bus Interface bus signals)| —| —| The APBS port is connected to APB
initiator. For example, CoreABC/Mi-V Soft Processor.
PADDR (input)| 29| This is the APB address bus driven by the initiator.
PENABLE (input)| 1| (Active-High) Enable signal from the initiator to trigger
APB transfer.
PRDATA (output)| 32| The selected target drives this data to the initiator
during read cycles when PWRITE is Low.
PREADY (output)| 1| (Active-High) This signal indicates that APB bus is ready
for transfer
to target. When PREADY is Low, the target initiates a transfer to DRI.
PSEL (input)| 1| (Active-High) The APB initiator generates this signal to each
DRI target. Indicates that the target device is selected and that a data
transfer is required. There is a PSELx signal for each target.
PSLVERR (output)| 1| (Active-High) This signal indicates a transfer failure.
PWDATA (input)| 32| (Active-High) This bus is driven by the APB initiator
during write cycles when PWRITE is High.
PWRITE (input)| 1| This signal indicates an APB write access when High and an
APB read access when Low.
The following sections describe DRI configuration for XCVR, TX PLL, PCIE, and CCC blocks using the PolarFire Dynamic Reconfiguration Interface Configurator window.
DRI Configuration for XCVR
In the XCVR tab, individual lanes (LANE_0 – 3) can be selected for each quad
lane (Qn Lanes, n = 0 – 5) as shown in Figure 3-2. For example, when Q0_LANE0
and Q0_LANE1 lane check boxes are selected in Q0 Lanes, Q0_LANE0 and Q0_LANE1
ports are added to the DRI IP block as shown in Figure 3-2.
Figure 3-2. The XCVR Tab
The DRI ports highlighted in the preceding figure are routed through hardwired
connections to the transceiver.
The following table describes the DRI ports.
Table 3-2. XCVR DRI Ports
Port Name | Libero BIF | Direction | Width | Description |
---|---|---|---|---|
DRI_ARST_N | — | Output | 1 | Active-Low asynchronous Reset signal |
from DRI to target.
DRI_CLK| —| Output| 1| Clock source to the target.
DRI_WDATA| —| Output| 32| DRI write data bus driven by DRI during
write cycles.
Q#_LANE#_DRI_CTRL| Q#_LANE#_DRI| Output| [10:0]| Embedded connection to
specified target
peripheral. Q# can be 0, 1, 2, 3, 4, 5,
LANE# can be 0, 1, 2, 3.
Q#_LANE#_DRI_INTERRUPT| Q#_LANE#_DRI| Input| —| Embedded connection to
specified target
peripheral. Q# can be 0, 1, 2, 3, 4, 5,
LANE# can be 0, 1, 2, 3.
Q#_LANE#_DRI_RDATA| Q#_LANE#_DRI| Input| [32:0]| Embedded connection to
specified target
peripheral. Q# can be 0, 1, 2, 3, 4, 5,
LANE# can be 0, 1, 2, 3.
For more information about user connections required while using DRI interface, see AC475: PolarFire FPGA Dynamic Reconfiguration Interface Application Note.
DRI Configuration for TX PLL
In the TX PLL tab, the required options per quad to enable DRI for both spread
spectrum generation capable transmit PLLs (Q#_TXPLL_SSC) and (Q#_TXPLLn)
without spread spectrum capabilities can be selected as shown in Figure 3-3.
The DRI option is provided for two Q#_TXPLLn (Q#_TXPLL0, Q#_TXPLL1) within
transceiver quad locations. For more information, see the “Transmit PLL”
section in UG0677: PolarFire FPGA Transceiver User
Guide.
Figure 3-3. The TX PLL Tab
The DRI target ports highlighted in the preceding figure are routed through hardwired connections to the transceiver PLL.
Table 3-3. TX PLL DRI Ports
Port Name | Libero BIF | Direction | Width | Description |
---|---|---|---|---|
Q#_TXPLL_SSC_DRI_CTRL | Q# TXPLL SSC DIRT | Output | [10:0] | Embedded connection |
to specified target peripheral. Q# can be 0, 1, 2, 3, 4, 5.
Q#_TXPLL_SSC_DRI_RDATA| Q#_TXPLLSSC DRI| Input| [32:0]| Embedded connection
to specified target peripheral. Q# can be 0, 1, 2, 3, 4, 5.
Q#_TXPLL_SSC_DRI_INTERRUPT| Q# TXPLL SSC Input
DIRT| Input| | Embedded connection to specified target peripheral. Q# can be
0, 1, 2, 3, 4, 5.
Q#_TXPLL_DRI_CTRL| Q#_TXPLL DRI| Output| [10:0]| Embedded connection to
specified target peripheral. Q# can be 3, 4, 5.
Q#_TXPLL_DRI_RDATA| Q#_TXPLL DRI| Input| [32:0]| Embedded connection to
specified target peripheral. Q# can be 3, 4, 5.
Q#_TXPLL_DRI_INTERRUPT| Q#_TXPLL DRI| Input| | Embedded connection to
specified target peripheral. Q# can be 3, 4, 5.
Q#TXPLLO_DRI_CTRL| Q#_TXPLLO DRI| Output| [10:0]| Embedded connection to
specified target peripheral. Q# can be 0, 1, 2.
Q#_TXPLLO_DRI_RDATA| Q#_TXPLLO DRI| Input| [32:0]| Embedded connection to
specified target peripheral. Q# can be 0, 1, 2.
Q#_TXPLL0_DRI_INTERRUPT| Q#_TXPLLO DRI| Input| | Embedded connection to
specified target peripheral. Q# can be 0, 1, 2.
Q#_TXPLL1_DRI_CTRL| Q#_TXPLL1_DRI| Output| [10:0]| Embedded connection to
specified target peripheral. Q# can be 0, 1, 2.
Q#_TXPLL1_DRI_RDATA| Q#_TXPLL1 DRI| Input| [32:0]| Embedded connection to
specified target peripheral. Q# can be 0, 1, 2.
Q#_TXPLL1_DRI_INTERRUPT| Q#_TXPLL1_DRI| Input| | Embedded connection to
specified target peripheral. Q# can be 0, 1, 2.
DRI Configuration for PCIE
PCIE controllers do not connect directly to a DRI port, the associated XCVR lanes must be connected to the DRI for dynamic control of the XCVR features. The PCIE controllers have a dedicated APB port for access to the register control within the PCIE subsystem. For more information, see UG0685: PolarFire FPGA PCI Express User Guide.
DRI Configuration for CCC
In the CCC tab, the required PLLs and DLLs (in all four corners NW, NE, SE, and SW) can be selected to enable DRI on the selected options and the corresponding DRI target interface is exposed as shown in the following figure.
Figure 3-4. The CCC Tab
The DRI target ports highlighted in the preceding figure are routed through
hardwired connections to the CCC.
The following table lists the CCC DRI ports.
Table 3-4. CCC DRI Ports
Port Name | Libero BIF | Direction | Width | Description |
---|---|---|---|---|
PLL0_**_DRI_CTRL | PLL0_**_DRI | Output | [10:0] | Embedded connection to |
specified target peripheral. can be NW, NE, SW, SE.
PLL0__DRIRDATA| PLL0_DRI| Input| [32:0]| Embedded connection to
specified target peripheral. can be NW, NE, SW, SE.
PLL0__DRIINTERRUPT| PLL0DRI| Input| —| Embedded connection to specified
target peripheral. ** can be NW, NE, SW, SE.
PLL1_DRICTRL| PLL1DRI| Output| [10:0]| Embedded connection to
specified target peripheral. ** can be NW, NE, SW, SE.
PLL1_DRIRDATA| PLL1DRI| Input| [32:0]| Embedded connection to
specified Target peripheral. ** can be NW, NE, SW, SE.
PLL1_DRIINTERRUPT| PLL1DRI| Input| —| Embedded connection to specified
target peripheral. ** can be NW, NE, SW, SE.
DLL0_DRICTRL| DLL0DRI| Output| [10:0]| Embedded connection to
specified target peripheral. ** can be NW, NE, SW, SE.
DLL0_DRIRDATA| DLL0DRI| Input| [32:0]| Embedded connection to
specified target peripheral. ** can be NW, NE, SW, SE.
DLL0_DRIINTERRUPT| DLL0DRI| Input| —| Embedded connection to specified
target peripheral. ** can be NW, NE, SW, SE.
DLL1_DRICTRL| DLL1DRI| Output| [10:0]| Embedded connection to
specified target peripheral. ** can be NW, NE, SW, SE.
DLL1_DRIRDATA| DLL1DRI| Input| [32:0]| Embedded connection to
specified target peripheral. ** can be NW, NE, SW, SE.
DLL1_DRIINTERRUPT| DLL1_DRI| Input| —| Embedded connection to specified
target peripheral. ** can be NW, NE, SW, SE.
Dynamic Configuration of CCC
Each CCC has a DRI which can be enabled to configure CCC parameters without
reprogramming the device. The CCC configuration is controlled by the volatile
configuration registers that are loaded with values from the flash
configuration bits at power-up. An APB bus initiator must be interfaced to the
CCC using a DRI macro for dynamic configuration. The APB bus initiator is used
to dynamically modify the CCC configuration register values as per design
needs. For more information on CCC configuration registers and their bit
definitions, see PolarFire Device Register Map.
To meet all the datasheet specifications, certain requirements must be met
when configuring the PLL/DLL parameters. The Libero CCC configurator
implements all these requirements and creates a valid solution for the
requested output clock frequencies and phases. Hence, Microchip recommends
that users generate the required configuration using Libero CCC configurator
and use the generated parameters in their dynamic configuration solution.
The PLL_POWERDOWN_N input must be asserted before making changes to the PLL
configuration parameters.
Note: Asserting the PLL_POWERDOWN_N signal resets the PLL operation.
When the CCC is configured in internal Post-VCO feedback mode, if the
requirement is to change the phase or output divider configuration then the
clock start/stop (OUT#_EN) signals can be used to stop the clock output before
making the changes for a glitch free configuration.
The following steps describe how to perform dynamic configuration of CCC:
-
Select Enable Dynamic Reconfiguration Interface under the Features section of CCC configurator as shown in Figure 3-5.
Figure 3-5. DRI Option in CCC
This enables and exposes the DRI on the instantiated CCC component as shown in the above figure. -
Instantiate and configure a PF_DRI SgCore with the required PLL enabled into the Smartening. The dynamic reconfiguration interface macro converts the APB interface signals to CCC dynamic reconfiguration interface signals. The DRI interface for the selected PLL is exposed on the PF_DRI macro. The APB port of DRI are shown in Figure 3-4. The DRI ports cannot be monitored or altered in the Libero design. These ports are used to facilitate HDL simulation of changes made to the CCC over the DRI. The PF_DRI SgCore converts standard APB3 read/writes to DRI transactions.
-
Double click the DRI macro to configure.
-
In the PF_DRI configurator, under the CCC tab, select the PLLs and DLLs that need dynamic configuration. The DRI macro interface is shown in Figure 3-4.
-
Connect the APB initiator port from an APB initiator (for example, Core ABC) to the mirrored initiator port of PF_DRI as shown in the following figure.
Figure 3-6. CCC Dynamic Configuration System
Misc Tab
In the Misc tab, the CRYPTO option can be selected to enable DRI on CRYPTO as
shown in Figure 3-7.
Note: The Enable latency simulation option is currently not supported.
Figure 3-7. Enabling DRI on CRYPTO
The following table lists the CRYPTO DRI ports.
Table 3-5. CRYPTO DRI Ports
Port Name | Libero BIF | Direction | Width | Description |
---|---|---|---|---|
CRYPTO_DRI_CTRL | CRYPTO_DRI | Output | [10:0] | Embedded connection to specified |
target
peripheral.
CRYPTO_DRI_RDATA| CRYPTO_DRI| Input| [32:0]| Embedded connection to specified
target
peripheral.
CRYPTO_DRI_INTERRUPT| CRYPTO_DRI| Input| —| Embedded connection to specified
target
peripheral.
Note: The ports highlighted in the above table are routed through hardwired connections to the User Crypto Processor.
Functional Timing Diagram
Figure 3-8 shows the DRI timing diagram.
Figure 3-8. APB Initiator Timing Diagram
For more information about FPD_PCLK, see DS0141: PolarFire FPGA
Datasheet.
The SDC constraint is derived and generated automatically based on the
connection of the PF_DRI IP to its APB initiator and to the DRI peripherals.
Static Timing Analysis (STA) of PCLK (FPD_PCLK) with SmartPower gives the
minimum and maximum analysis of the APB interface Tus/thud parameters.
Revision History
The revision history table describes the changes that were implemented in the
document. The changes are listed by revision, starting with the most current
publication.
Table 4-1. Revision History
Revision | Date | Description |
---|---|---|
A | 06/2021 | The first publication of this document. |
The Microchip Website
Microchip provides online support via our website at
www.microchip.com/. This website is used to make
files and information easily available to customers. Some of the content
available includes:
- Product Support – Data sheets and errata, application notes and sample programs, design resources, user’s guides and hardware support documents, latest software releases and archived software
- General Technical Support – Frequently Asked Questions (FAQs), technical support requests, online discussion groups, Microchip design partner program member listing
- Business of Microchip – Product selector and ordering guides, latest Microchip press releases, listing of seminars and events, listings of Microchip sales offices, distributors and factory representatives
Product Change Notification Service
Microchip’s product change notification service helps keep customers
current on Microchip products. Subscribers will receive email notification
whenever there are changes, updates, revisions or errata related to a
specified product family or development tool of interest.
To register, go to www.microchip.com/pcn and
follow the registration instructions.
Customer Support
Users of Microchip products can receive assistance through several
channels:
- Distributor or Representative
- Local Sales Office
- Embedded Solutions Engineer (ESE)
- Technical Support
Customers should contact their distributor, representative or ESE for support. Local sales offices are also available to help customers. A listing of sales offices and locations is included in this document.
Technical support is available through the website at: www.microchip.com/support
Microchip Devices Code Protection Feature
Note the following details of the code protection feature on Microchip
devices:
- Microchip products meet the specifications contained in their particular Microchip Data Sheet.
- Microchip believes that its family of products is secure when used in the intended manner and under normal conditions.
- There are dishonest and possibly illegal methods being used in attempts to breach the code protection features of the Microchip devices. We believe that these methods require using the Microchip products in a manner outside the operating specifications contained in Microchip’s Data Sheets. Attempts to breach these code protection features, most likely, cannot be accomplished without violating Microchip’s intellectual property rights.
- Microchip is willing to work with any customer who is concerned about the integrity of its code.
- Neither Microchip nor any other semiconductor manufacturer can guarantee the security of its code. Code protection does not mean that we are guaranteeing the product is “unbreakable.” Code protection is constantly evolving. We at Microchip are committed to continuously improving the code protection features of our products. Attempts to break Microchip’s code protection feature may be a violation of the Digital Millennium Copyright Act. If such acts allow unauthorized access to your software or other copyrighted work, you may have a right to sue for relief under that Act.
Legal Notice
Information contained in this publication is provided for the sole purpose
of designing with and using Microchip products. Information regarding device
applications and the like is provided only for your convenience and may be
superseded by updates. It is your responsibility to ensure that your
application meets with your specifications.
THIS INFORMATION IS PROVIDED BY MICROCHIP “AS IS”. MICROCHIP MAKES NO
REPRESENTATIONS OR WARRANTIES OF ANY KIND WHETHER EXPRESS OR IMPLIED, WRITTEN
OR ORAL, STATUTORY OR OTHERWISE, RELATED TO THE INFORMATION INCLUDING BUT NOT
LIMITED TO ANY IMPLIED WARRANTIES OF NON-INFRINGEMENT, MERCHANTABILITY, AND
FITNESS FOR A PARTICULAR PURPOSE OR WARRANTIES RELATED TO ITS CONDITION,
QUALITY, OR PERFORMANCE.
IN NO EVENT WILL MICROCHIP BE LIABLE FOR ANY INDIRECT, SPECIAL, PUNITIVE,
INCIDENTAL OR CONSEQUENTIAL LOSS, DAMAGE, COST OR EXPENSE OF ANY KIND
WHATSOEVER RELATED TO THE INFORMATION OR ITS USE, HOWEVER CAUSED, EVEN IF
MICROCHIP HAS BEEN ADVISED OF THE POSSIBILITY OR THE DAMAGES ARE FORESEEABLE.
TO THE FULLEST EXTENT ALLOWED BY LAW, MICROCHIP’S TOTAL LIABILITY ON ALL
CLAIMS IN ANY WAY RELATED TO THE INFORMATION OR ITS USE WILL NOT EXCEED THE
AMOUNT OF FEES, IF ANY, THAT YOU HAVE PAID DIRECTLY TO MICROCHIP FOR THE
INFORMATION. Use of Microchip devices in life support and/or safety
applications is entirely at the buyer’s risk, and the buyer agrees to defend,
indemnify and hold harmless Microchip from any and all damages, claims, suits,
or expenses resulting from such use. No licenses are conveyed, implicitly or
otherwise, under any Microchip intellectual property rights unless otherwise
stated.
Trademarks
The Microchip name and logo, the Microchip logo, Adaptec, AnyRate, AVR, AVR
logo, AVR Freaks, BesTime, BitCloud, chipKIT, chipKIT logo, Crypto Memory,
Cryptor, dsPIC, FlashFlex, flexPWR, HELDO, IGLOO, JukeBlox, KeeLoq, Kleer,
LANCheck, LinkMD, maXStylus, maXTouch, Medially, megaAVR, Microsemi, Microsemi
logo, MOST, MOST logo, MPLAB, OptoLyzer, PackeTime, PIC, picoPower, PICSTART,
PIC32 logo, PolarFire, Prochip Designer, QTouch, SAM-BA, SenGenuity, SpyNIC,
SST, SST Logo, SuperFlash, Symmetricom, SyncServer, Tachyon, TimeSource,
tinyAVR, UNI/O, Vectron, and XMEGA are registered trademarks of Microchip
Technology Incorporated in the U.S.A. and other countries.
AgileSwitch, APT, ClockWorks, The Embedded Control Solutions Company,
EtherSynch, FlashTec, Hyper Speed Control, Hyperlight Load, Intel limos,
Libero, motorBench, mTouch, Powermite 3, Precision Edge, ProASIC, ProASIC
Plus, ProASIC Plus logo, Quiet-Wire, SmartFusion, SyncWorld, Timex,
TimeCesium, TimeHub, TimePictra, TimeProvider, WinPath, and ZL are registered
trademarks of Microchip Technology Incorporated in the U.S.A. Adjacent Key
Suppression, AKS, Analog-for-the-Digital Age, Any Capacitor, AnyIn, AnyOut,
Augmented Switching, BlueSky, BodyCom, CodeGuard, CryptoAuthentication,
CryptoAutomotive, CryptoCompanion, CryptoController, dsPICDEM, dsPICDEM.net,
Dynamic Average Matching, DAM, ECAN, Espresso T1S, EtherGREEN, IdealBridge,
In-Circuit Serial Programming, ICSP, INICnet, Intelligent Paralleling, Inter-
Chip Connectivity, JitterBlocker, maxCrypto, maxView, memBrain, Mindi, MiWi,
MPASM, MPF, MPLAB Certified logo, MPLIB, MPLINK, MultiTRAK, NetDetach,
Omniscient Code Generation, PICDEM, PICDEM.net, PICkit, PICtail, PowerSmart,
PureSilicon, QMatrix, REAL ICE, Ripple Blocker, RTAX, RTG4, SAM-ICE, Serial
Quad I/O, simpleMAP, SimpliPHY, SmartBuffer, SMART-I.S., storClad, SQI,
SuperSwitcher, SuperSwitcher II, Switchtec, SynchroPHY, Total Endurance,
TSHARC, USBCheck, VariSense, VectorBlox, VeriPHY, ViewSpan, WiperLock,
XpressConnect, and ZENA are trademarks of Microchip Technology Incorporated in
the U.S.A. and other countries.
SQTP is a service mark of Microchip Technology Incorporated in the U.S.A.
The Adaptec logo, Frequency on Demand, Silicon Storage Technology, and Symmcom
are registered trademarks of Microchip Technology Inc. in other countries.
GestIC is a registered trademark of Microchip Technology Germany II GmbH & Co.
KG, a subsidiary of Microchip Technology Inc., in other countries. All other
trademarks mentioned herein are property of their respective companies. ©
2021, Microchip Technology Incorporated, Printed in the U.S.A., All Rights
Reserved. ISBN: 978-1-5224-8315-1
Quality Management System
For information regarding Microchip’s Quality Management Systems, please visit
www.microchip.com/quality.
Worldwide Sales and Service
AMERICAS | ASIA/PACIFIC | ASIA/PACIFIC | EUROPE |
---|
Corporate Office
2355 West Chandler Blvd.
Chandler, AZ 85224-6199
Tel: 480-792-7200
Fax: 480-792-7277
Technical Support:
www.microchip.com/support
Web Address: www.microchip.com
Atlanta
Duluth, GA
Tel: 678-957-9614
Fax: 678-957-1455
Austin, TX
Tel: 512-257-3370
Boston
Westborough, MA
Tel: 774-760-0087
Fax: 774-760-0088
Chicago
Itasca, IL
Tel: 630-285-0071
Fax: 630-285-0075
Dallas
Addison, TX
Tel: 972-818-7423
Fax: 972-818-2924
Detroit
Novi, MI
Tel: 248-848-4000
Houston, TX
Tel: 281-894-5983
Indianapolis
Noblesville, IN
Tel: 317-773-8323
Fax: 317-773-5453
Tel: 317-536-2380
Los Angeles
Mission Viejo, CA
Tel: 949-462-9523
Fax: 949-462-9608
Tel: 951-273-7800
Raleigh, NC
Tel: 919-844-7510
New York, NY
Tel: 631-435-6000
San Jose, CA
Tel: 408-735-9110
Tel: 408-436-4270
Canada – Toronto
Tel: 905-695-1980
Fax: 905-695-2078| Australia – Sydney
Tel: 61-2-9868-6733
China – Beijing
Tel: 86-10-8569-7000
China – Chengdu
Tel: 86-28-8665-5511
China – Chongqing
Tel: 86-23-8980-9588
China – Dongguan
Tel: 86-769-8702-9880
China – Guangzhou
Tel: 86-20-8755-8029
China – Hangzhou
Tel: 86-571-8792-8115
China – Hong Kong SAR
Tel: 852-2943-5100
China – Nanjing
Tel: 86-25-8473-2460
China – Qingdao
Tel: 86-532-8502-7355
China – Shanghai
Tel: 86-21-3326-8000
China – Shenyang
Tel: 86-24-2334-2829
China – Shenzhen
Tel: 86-755-8864-2200
China – Suzhou
Tel: 86-186-6233-1526
China – Wuhan
Tel: 86-27-5980-5300
China – Xian
Tel: 86-29-8833-7252
China – Xiamen
Tel: 86-592-2388138
China – Zhuhai
Tel: 86-756-3210040| India – Bangalore
Tel: 91-80-3090-4444
India – New Delhi
Tel: 91-11-4160-8631
India – Pune
Tel: 91-20-4121-0141
Japan – Osaka
Tel: 81-6-6152-7160
Japan – Tokyo
Tel: 81-3-6880- 3770
Korea – Daegu
Tel: 82-53-744-4301
Korea – Seoul
Tel: 82-2-554-7200
Malaysia – Kuala Lumpur
Tel: 60-3-7651-7906
Malaysia – Penang
Tel: 60-4-227-8870
Philippines – Manila
Tel: 63-2-634-9065
Singapore
Tel: 65-6334-8870
Taiwan – Hsin Chu
Tel: 886-3-577-8366
Taiwan – Kaohsiung
Tel: 886-7-213-7830
Taiwan – Taipei
Tel: 886-2-2508-8600
Thailand – Bangkok
Tel: 66-2-694-1351
Vietnam – Ho Chi Minh
Tel: 84-28-5448-2100| Austria – Wels
Tel: 43-7242-2244-39
Fax: 43-7242-2244-393 Denmark – Copenhagen Tel: 45-4485-5910 Fax:
45-4485-2829 Finland – Espoo Tel: 358-9-4520-820 France – Paris Tel:
33-1-69-53-63-20
Fax: 33-1-69-30-90-79
Germany – Garching
Tel: 49-8931-9700
Germany – Haan
Tel: 49-2129-3766400
Germany – Heilbronn
Tel: 49-7131-72400
Germany – Karlsruhe
Tel: 49-721-625370
Germany – Munich
Tel: 49-89-627-144-0
Fax: 49-89-627-144-44 Germany – Rosenheim
Tel: 49-8031-354-560
Israel – Ra’anana
Tel: 972-9-744-7705
Italy – Milan
Tel: 39-0331-742611
Fax: 39-0331-466781
Italy – Padova
Tel: 39-049-7625286
Netherlands – Drunen
Tel: 31-416-690399
Fax: 31-416-690340
Norway – Trondheim
Tel: 47-72884388
Poland – Warsaw
Tel: 48-22-3325737
Romania – Bucharest
Tel: 40-21-407-87-50
Spain – Madrid
Tel: 34-91-708-08-90
Fax: 34-91-708-08-91
Sweden – Gothenberg
Tel: 46-31-704-60-40
Sweden – Stockholm
Tel: 46-8-5090-4654
UK – Wokingham
Tel: 44-118-921-5800
Fax: 44-118-921-5820
© 2021 Microchip Technology Inc.
DS60001711A-page 19
Documents / Resources
|
MICROCHIP PolarFire and PolarFire SoC DRI Icicle
Kit
[pdf] User Guide
PolarFire and PolarFire SoC DRI Icicle Kit, PolarFire SoC DRI Icicle Kit, DRI
Icicle Kit, Icicle Kit
---|---
References
- {波多野42部无码喷潮在线,18禁美女裸身无遮挡免费网站,国产成人精品一区二三区在线观看,久久精品国产亚洲AⅤ无码}
- Empowering Innovation | Microchip Technology
- Empowering Innovation | Microchip Technology
- Microchip Lightning Support
- Downloads | Other | SoC | Internal Documents | Microsemi
- Microsemi_PolarFire_FPGA_DRI.pdf
- Downloads | Other | SoC | Internal Documents | Microsemi
- microsemi.com/index.php?option=com_docman&task=doc_download&gid=1245725
- microsemi.com/index.php?option=com_docman&task=doc_download&gid=136531
- Document Details | | Microsemi
- Microsemi | Semiconductor & System Solutions | Power Matters
- apps/baremetal_applications/DRI at master · polarfire-soc/apps · GitHub
- microsemi.com/document-portal/doc_download/136519-ds0141-polarfire-fpga-datasheet
- PolarFire® SoC MSS Configurator | Microchip Technology
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>