ALLMATIC IRIS IRIS LED Adjustable Photocells with Led Light Instructions
- June 14, 2024
- ALLMATIC
Table of Contents
ALLMATIC IRIS IRIS LED Adjustable Photocells with Led Light
DESCRIPTION
Modulated infrared photocell composed of transmitter and receiver (powered
from 12-24 Vac / Vdc source). The equipment is housed in a water-proof plastic
shockproof container. The optic is adjustable on frictioned and self-locking
joints both horizontally, being able to rotate 180°, and vertically with a
possible rotation of ± 10° with respect to the horizontal. Double relay
equipment with series exchanges, the NC contact complies with the standards of
category 3 of UNI EN ISO 13849-1 (update of EN 954-1). Possibility to connect
up to 8 pairs of photocells by synchronizing the transmission (multiplexed
system).
The models: IRIS, adjustable photocells; IRIS LED (integrated LED circuit
board on both devices, Tx and Rx), see figures n. 2, 5.
The package includes : 1 transmitter; 1 receiver; set of screws and gaskets.
POSSIBILITY OF USE
The IRIS photocell represents an efficient safety system for the protection of gates subject to automated installations of remote controlled doors and gates. The use and installation of these appliances must strictly comply with the indications provided by the manufacturer and the safety regulations in force.
DETAILS (FIG. 1)
A | Holes for surface mounting |
---|---|
B | Hole for cable passage from the back of the container |
C | Lockable rotation locking device, removable with a screwdriver |
D | Adjustable optics on horizontal and vertical axis |
E | Alignment signaling LED: OFF = Correct alignment |
F | Transmitter power supply input (Vdc / Vac) |
G | Connection for synchronized operation |
H | Dip switch for code selection and device type (master, slave) |
I | Receiver power supply input (Vdc / Vac) |
L | Contacts Receiver (COM – NC) / (COM – NO) |
N | Led board power supply input (Vdc / Vac)1 |
1 Only on IRIS LED model
DIP N. 4 TX | MASTER / SLAVE (6.1) |
---|---|
ON – MASTER | |
OFF – SLAVE | |
DIP N. 4 TX | MASTER / SLAVE (6.2) |
--- | --- |
ON – MASTER | |
OFF – SLAVE |
SURFACE FIXING
Fix the bottom of the box keeping in mind the dimensions indicated in Fig. 3 and 4.
CONNECTIONS
Make the connections following the instructions shown in the figure 1
Tx / Rx power supply: Power with a 12/24 Vac / Vdc source. Pay attention to
the polarity.
Pairs synchronization: If more than one pair of photo devices are used,
synchronize the transmitters by connecting them to terminals A, B ( Fig.
11 ). Configure a single device as MASTER. Assign each device a different
code.
Raggio libero
Free beam
Rayo libre
Rayon libre
Vrije straa
Alimentazione assente
No power supply
Only for IRIS LED model: Supply the LED boards ( Fig. 2 ) with a 24Vac / Vdc source of adequate power.
WARNING! The cables must be wired as short as possible, also avoiding passing close to other sources of disturbance (such as motors). To improve the immunity to disturbances of the photo devices, it is necessary to use a shielded cable for connection to the control unit and to earth the photocell (only if powered with DC current, Vdc).
ALIGNMENT
Slightly loosen the rotation block (C) with a screwdriver, then carefully adjust the optic (D) as shown in figures 6 and 7.
SYNCHRONIZED OPERATION
Multiplexed system (MAX 8 COUPLES)
-
Place all the transmitters on the same side;
-
Connect the SYNC inputs of the transmitters respecting the polarities, see figure 8.
-
Set the DIPs 1 to 3 (transmitter and receiver) on each pair progressively according to the configurations of the table Tab.1
Couple number| DIP 1, 2, 3 Tx, Rx| Code
---|---|---
1| | 1
2| | 2
3| | 3
4| | 4
5| | 5
6| | 6
7| | 7
8| | 8 -
Select a single pair of photocells as MASTER, set the other pairs as SLAVE, Tab. 1
-
Perform alignment of all pairs of photocells e check correct alignment (Fig. 6, 7).
See LED alignment (Fig. 1) -
Power all the photocell pairs: the multiplexed system is configured. Synchronized operation is useful if several pairs of photocells are installed, to prevent the transmitters and receivers of different pairs from interfering with each other.
WARNING! In case of rain, snow, fog or dust, the range of the photocell may decrease.
TEST FUNCTION SIGNAL QUALITY
By placing the DIP4 in OFF of the RX photocell you can activate the function
that allows you to visually understand the quality of the signal present
between the two photocells TX and RX.
The more the quality of the signal is good, the more the LED will be turned on
intensely; the more the quality of the signal is poor or absent, the weaker
the LED will be or off.
WARNING! When this function is active, the photocell is placed in the
committed state. By returning the DIP4 to ON, the normal functioning of the
photocell is restored, which is put in the committed/disengaged state
according to the presence or absence of the infrared signal received by the
TX.
TECHNICAL FEATURES
Power supply
(Tx / Rx)| Vac 50/60Hz| 10…30
---|---|---
Vdc| 10…35
Nominal range| 30 m
Horizontal orientation angle| -90°…+90°
Vertical orientation angle| -10°…+10°
Current absorption| RX
44 mA (12Vac)
27 mA (24Vac)
21 mA (12Vdc)
11 mA (24Vdc)| TX
13 mA (12Vac)
10 mA (24Vac)
6 mA (12Vdc)
3,5 mA (24Vdc)
Relay contact| 1A 24Vdc
Obstacle detection time| 100 ms
Synchronized operation| yes (8 pairs)
Frequency modulation| 100 kHz
Working temperature| -10°C…+55°C
Protection class| IP54
LED CIRCUIT BOARD (INTEGRATED ON Tx and Rx of IRIS LED
version)
Integrated Led type| 6 x 4500mcd 7000K
Led circuit board power supply| 13Vac…28Vac 13Vdc…35Vdc
Led circuit board current absorption| 30 mA (24Vac)
16 mA (24Vdc)
WARRANTY TERMS
The manufacturer’s warranty is valid legally from the date stamped on the
product and covers only the free repair or replacement of the pieces
acknowledged by the manufacturer to be faulty due to lack of essential quality
of materials or bad workmanship. The warranty does not cover damage or faults
due to external agents, bad maintenance, overloads, normal wear, bad assembly
or any other causes that cannot be put down to the manufacturer. Products that
have been tampered with shall be neither guaranteed nor repaired. The details
shown are merely approximate. No liability can be accepted for range drops or
malfunctions due to environmental interference.
The manufacturer shall only be liable for injury to persons caused by
accidents of any nature caused by faulty products to the extent laid down
irrevocably by Italian law.
DISPOSAL OF THE PRODUCT
This product is an integral part of the automation, and therefore, they must
be disposed of together. As for the installation operations, at the end of the
life of this product, the dismantling operations must be performed by
qualified personnel. This product is made from different types of materials:
some can be recycled, others must be disposed of. Please inform yourselves on
the recycling or disposal systems provided for by the laws in force in your
area, for this category of product.
CAUTION! Some parts of the product can contain polluting or dangerous
substances which, if dispersed in the environment, may cause serious harm to
the environment and human health. As indicated by the symbol at the side, it
is forbidden to throw this product into domestic refuse.
Therefore, follow the “separated collection” instructions for disposal,
according to the methods provided for by local regulations in force, or
redeliver the product to the retailer at the moment of purchase of a new,
equivalent product. CAUTION! The regulations in force at local level may
envisage heavy sanctions in case of abusive disposal of this product.
Read User Manual Online (PDF format)