ALLMATIC 1621090 Helios Kairos Instruction Manual
- June 14, 2024
- ALLMATIC
Table of Contents
HELIOS
KAIROS
Control unit for awnings with management of wireless sensors
1621090 Helios Kairos
MADE IN ITALY
Please read this instruction manual very carefully before installing and
programming your control unit.
After the installation keep this instruction in a safe place for any further
consultation.
- The device must not be used by people (children included), whose physical, sensory and mental capacities are reduced, or without experience or knowledge, unless they could benefit through the intermediation of a person responsible for their safety, of a surveillance or of instructions related to the use of the device.
- Children must be kept under surveillance to make sure that they do not play with the device.
- If the power supply’s cable is damaged, it must be replaced by the manufacturer or by his assistance service or in any case by a person with similar status in order to prevent any risk.
- This instruction manual is only for qualified technicians, who specialize in installations and automations.
- The contents of this instruction manual do not concern the final user.
- Every programming and/or every maintenance service should be done only by qualified technicians.
- The installer must provide the installation of a device (es. magnetothermical switch) that ensures the omnipolar sectioning of the equipment from the power supply.
INTRODUCTION
HELIOS KAIROS control units are universal devices suitable to handle the
activation and the control of awnings in a simple and complete way, designed
to meet any sort of requirements.
This product 230V motors in alternating current up to 500 W (max) power supply
and is provided with electric limit switches. HELIOS KAIROS control unit uses
the innovative rolling code decoding system: this choice makes it safe,
easily expandable and its installation is quick and intuitive. The logic of
the HELIOS KAIROS offers the possibility to manage the KAIROS wireless
climatic sensors (light, wind, rain and temperature), KAIROS DUO (light and
wind), KAIROS PERGOLA (wind, rain and temperature) and AXEM (wind and
inclination), all with broadcast radio frequency 433.92MHz.
These lets HELIOS KAIROS to open and / or close the awning fully
automatically, depending on weather conditions.
CONFIGURATION
ELECTRICAL CONNECTIONS AND DIP SWITCH
DIP | Function | DIP OFF | DIP ON |
---|---|---|---|
1 | Automatic reopening | Disabled | Enable |
2 | Cabled inputs | Dead man | Impulsive |
3 | Rain disabling | Cannot be disabled | Can be disabled |
4 | Transmitters keys | Direct | Reverse |
5 | Light sensor | Disabled | Enable |
6 | Wind sensor | Disabled | Enable |
7 | Rain sensor | Disabled | Enable |
8 | Snow sensor | Disabled | Enable |
LEARNING
4.1 Learning transmitter through the learning key of the control unit
HELIOS KAIROS control unit can be operated by all remotes B.RO 2/4WN, WALL 433
MHz and the CLARUS series.
- Press and release the learning key on the card; the red LED lights up.
- Press “a” or “a1” of the transmitter. The control unit also automatically memorize the key “b” or “b1” and the “c” keys to the series CLARUS (“a” or “a1” like button “open”, “b” or “b1” how “close” button and “c” as a “stop” button). The control unit signals the memorization of the channel with two flashings if the channel was not memorized, with one if the channel was already learned.
- Once memorized the channel, the control unit goes back to normal modality of functioning.
If no signal is transmitted by 20 seconds, the control unit automatically exits from the learning mode.
Warning: keys functions are only valid with the DIP4 OFF (see 6.2.4)
4.2 Learning subsequent transmitters with a transmitter already learned
Warning: Do not use this procedure if you have multiple units in
operation, since the store opening would affect all devices where the channel
is stored. In this case, disconnect the power supply of the control units
which shall not be involved.
- Opening of memory: to open the memory from the transmitter, refer to the instructions enclosed to the transmitter. Once you open the control unit memory, it indicates this by turning on the red LED.
- Press “a” or “a1” of the transmitter. The control unit also automatically memorize the key “b” or “b1” and the “c” key to the series CLARUS (“a” or “a1” like button “open”, “b” or “b1” how “close” button and “c” as a “stop” button). The control unit signals the memorization of the channel with two flashings if the channel was not memorized, with one if the channel was already learned.
- Once memorized the channel, the control unit goes back to normal modality of functioning. If no signal is transmitted by 20 seconds, the control unit automatically exits from the learning mode.
Warning: keys functions are only valid with the DIP4 OFF (see 6.2.4)
4.3 Parameter reset to factory defaults
This deletes all parameters (position automatic opening, alarms) without
erasing all transmitters.
To restore the parameters to the factory default is sufficient to do the
following:
- Close the awning.
- Press and hold for almost 7 seconds the learning key until the red LED alarm / learning flashes rapidly.
- Release the button.
The red LED stops blinking. The restoration has been performed.
4.4 Resetting the memory and reset to factory settings
At any time it’s possible to reset the factory settings by resetting the card.
This also leads to the cancellation of all the remote controls, sensors and
automatic opening position.
To reset the board is sufficient to do the following:
- Remove power to the control unit.
- Press and hold the learning key while the control unit is powered up. The three LEDs red, green and yellow lights flash once and after that they stay on.
- Hold down the key until the red LED turns off.
- Release the key.
After this operation every remote control and any wireless sensor must be programmed again.
USING A TRANSMITTER
By closed awning, pressing the key “a” of opening, the awning will roll down. To stop the rolling down press the reverse key “b” or the “c” STOP (only for series CLARUS). A subsequent pression of “b” will reverse the rolling motion.
Warning: keys functions are only valid with the DIP4 OFF (see 6.2.4)
SETTINGS
6.1 Control unit behaviour
HELIOS KAIROS control unit drives motors with internal limit switches with an
admitted opening time of 7 minutes.
In case in which the awning is stopped for the intervention of a limit switch,
the control unit remains on the state of opening awning until the reaching of
the 7 minutes. In this interval of time 2 “CLOSE” commands will be necessary
to bring the awning on closing (because it will be necessary to pass for the
STOP state).
At the same way, in case in which the awning would be opened and the control
unit would find itself in the state of “STOP”, an order of closing would draw
back the awning for a time determined by the intervention of the limit
switches of the motor. Despite the awning has been totally closed, the
control unit will continue on the closing state until the reaching of the 7
minutes. For this reason in this interval of time 2 “OPEN” commands will be
necessary to bring the awning on opening (because it will be necessary to
pass for the STOP state).In conclusion, it is necessary to keep in mind that
the condition of open/close awning for the control unit do not always
correspond to the real condition of the open/close awning.
NOTA: in case that the control unit is on the closing position and,
through the manual override, the awning is brought to the opening position, an
intervention of the sensors (wind, light, rain, snow) will not make close the
awning as, the control unit is still under the closing position.
6.2 Control unit behaviour with light sensor enabled
The control HELIOS KAIROS, with the use of the light sensor, becomes fully
automatic and opens and closes depending on the light threshold set on sensor.
The light sensor has priority over user commands (transmitters and cabled
inputs).
The sensor status light is visible through the green LED of the control unit:
-
Off status: light below the set threshold (awning closed).
-
Blinking: light above the set threshold (open awning).
The state of the control unit is visible through the yellow LED of the control unit: -
1 flash per second: temporary exclusion of the sensors (see 8.2).
-
1 blink every 2 seconds: winter mode (see 8.3).
-
Flashing quickly: learning of automatic opening position (see 8.1).
6.3 Control unit behaviour during alarm (wind, rain, snow, disconnection)
The presence of an alarm will immediately close the awning and block the
operation of the transmitters and cabled inputs for 7 minutes after the
finishing of the alarm. A slow flashing red LED indicates to the user the
alarm condition.
The detection of the snow (snow alarm) occurs in different ways depending on
the type of sensor:
- Sensor powered from the mains (KAIROS): presence of rain and temperature below 4°C (sensor with heater).
- Sensor powered by photovoltaic panel (KAIROS SA): only temperature lower than 2°C regardless of the presence of rain (sensor not equipped with heater).
- AXEM sensor: inclination of the awning more than 2° compared to the memorized position.
A rapid flashing of the red LED indicates a disconnection alarm of the sensors, the awning can be activated only by disabling all sensors (DIP 5, 6, 7, 8 OFF); in this case, however, the awning will not be closed by the presence of wind, rain or snow alarm.
6.4 Control unit behaviour after power failure
The control unit after a power failure, returns to automatic operation,
starting as from the position of the awning before the blackout, data,
setting, transmitters and sensors will remain memorized.
6.5 Selection of functions
The selection of functions are set through 8 DIP SWITCH.
CLIMATIC SENSOR
7.1 Learning a climatic sensor
- Press and release the learning key on the control unit, the red LED lights up.
- Press and release the key on the sensor, the control unit signals the correct memorization with two flashes of the red LED.
Once memorized the sensor, you can test the transmission by pressing the key on the sensor. The control unit shows the reception of the broadcast with a rapid flashing of the yellow LED.
7.2 Checking the motor direction during in alarm
This procedure is necessary to verify correct wiring of the motor, so that the
awning will be closed in case of alarm.
- Temporarily disable the operation of the light sensor DIP 5 OFF.
- With a transmitter or cabled inputs move the awning at about halfway and stop it.
- On the KAIROS sensor, adjust the trimmer to minimum wind (TEST) and rotate the blades of the sensor at a constant speed for few seconds. On the used AXEM sensor,shake the awning until the intervention of the sensor.
- The control unit will show the alarm with the blinking of the red LED and will reclose the awining.
If the awning moves in opening remove power to the control unit and swap the motor cables 14-15 and make again the test above. If the awning moves in closing, wait until it is completely closed, press and hold the learning key until the red LED start blinking faster, release the button.
Set the desired speed of wind on the sensor with the trimmer and re-able the light sensors DIP 5 ON.
7.3 Deleting a climatic sensor
- Press and release the learning key on the card, the red LED lights up.
- Press and release the key on the sensor, the control unit shows the deletion with four long flashes of the red LED.
7.4 Behaviour of the AXEM sensor
The alarms of the AXEM sensor are disabled for all the working time of the
control unit and for more:
- 10 seconds, for the wind alarms;
- 15 minutes, for the tilt alarms.
To delete the waiting time and enable the sensor immidiately, press the learning button on the Axem device.
ADVANCED SETTINGS
8.1 Setting the partial open position (only with light sensor enabled)
You can set a desired position for automatic opening due to the light sensor,
this procedure can only be done if the light sensor is present and enabled
(DIP 5 ON):
- Close the awning.
- Upon reaching the closed position, press and hold the learning key on the control unit until the red LED flashes rapidly, release the key.
- Press and hold the open key of a transmitter or (only with DIP 2 ON) a cabled input until the yellow LED flashes quickly, the awning begins to open, release the button.
- To set the position it’s sufficient to stop the awning (with a stop or a close input).
8.2 Temporary exclusion of the rain and light sensors
This mode is used to temporarily disable the light and rain sensors (the rain
sensor can be temporarily disabled only if DIP switch 3 ON):
- Move the awning to the desired position.
- With the awning still in motion press and hold for 5 seconds the stop key (CLARUS) or the key of opposite movement with B.RO 2/4WN WALL or cabled inputs.
- The control unit shows the disabling of the sensors with 1 flash per second of the yellow LED.
The rain sensor, if the DIP 3 ON is disabled for 2 hours, if DIP switch 3 OFF is never disabled.
The light sensor is disabled for a full cycle of light (night-day, day-night). To exit the disabling sensors, it’s sufficient to provide an open or close command and the control unit will return to automatic mode.
8.3 Winter mode
This mode allows you to inhibit all the automatic movements of the control
unit, which is useful during the winter:
- Awning must not be in movement, it can be stopped at any position.
- Press and hold the close button for 5 seconds.
- The yellow LED indicates the entry of the winter mode with a blink every 2 seconds.
- Once the awning has reached the closure, it inhibit any automatism.
To exit the winter mode, it’s sufficient to provide an opening command and the control unit will return to the automatic mode.
Note: the function can be used only if a light sensor is already memorized and it is enabled.
8.4 “Clock” function
The clock function cannot be used with dead man modality (DIP 2 OFF) and with
the light sensor enabled (DIP 5 ON).
This mode allows you to open and close the awning at specific times using a
timer, which maintains closed the wired contact “open” for more than 4
minutes. The awning will remain open until the contact is closed.
An alarm will close the awning and once the alarm stops, the awning is getting
opened, regardless of the position of the DIP 1.
8.5 LED indicator
The control unit is equipped with 8 LEDs for indicating the status of the
sensors, and handling operations.
LED1 ON: light above the set threshold
LED2 ON: wind speed above the set threshold
LED3 ON: rain detected
LED 4 ON: snow detected (see 6.3)
LED5 ON: the control unit is using the internal memory
LED6 ON: clock function
LED7 ON: awning is closing
LED8 ON: awning is opening
TROUBLESHOOTING
Problem | Possible causes | Solutions |
---|
When power up the
control unit no LED come up| • Missing power supply
• Plug is not connected
• Power failure| • Wait until it comes back
• Insert the plug
• Check the connections, see paragraph 3
Transmitters keys doesn’t
work| • Transmitter isn’t learnt on the control unit
• Transmitter isn’t compatible with the control unit
• Low battery on the transmitter
• Radio module not present or broken| • Follow the procedure on paragraph 4.1
• Check if transmitter is a B.RO o
CLARUS series
• Change the battery
• Insert the radio module or change it
Red LED continues
blinking| • One or more sensors in allarm
• Broken or low power on sensor
• Sensor disconnection| • Check the 8 LEDs to understand which sensor is in
alarm
• Need a technical intervention
• In case of disconnection (fast blinking of red LED) and need to move the
awning, set to OFF DIPs 5,6,7,8
REMOVING A TRANSMITTER
10.1 Removing a transmitters from the control unit
REMOVING transmitter series B.ro:
Press the hidden key “e” on the transmitter; the red LED turns on. This
operation is equivalent to press the learning key, but without access to the
control unit.
Press at the same time for some seconds the hidden key and “a” key of the
radio transmitter to erase (“e”+ “a”). The control unit signals the happened
erasing with 4 long blinks. After that the control unit goes back to the
normal modality of functioning.
REMOVING transmitter series CLARUS
To delete one channel or the whole transmitter it is necessary to access to
the internal menu of the transmitter.
To do this refer to the instructions of the transmitter in use.
Warning: Do not use this procedure if you have multiple units in operation, since the store opening would affect all the devices where the channel is stored. In this case, disconnect the power supply of the control units which shall not be involved
GUARANTEE
In compliance with legislation, the manufacturer’s guarantee is valid from the
date stamped on the product and is restricted to the repair or free
replacement of the parts accepted by the manufacturer as being defective due
to poor quality materials or manufacturing defects. The guarantee does not
cover damage or defects caused by external agents, faulty maintenance,
overloading, natural wear and tear, choice of incorrect product, assembly
errors, or any other cause not imputable to the manufacturer. Products that
have been misused will not be guaranteed or repaired.
Printed specifications are only indicative. The manufacturer does not accept
any responsibility for range reductions or malfunctions caused by
environmental interference. The manufacturer’s responsibility for damage
caused to persons resulting from accidents of any nature caused by our
defective products, are only those responsibilities that come under Italian
law.
ALLMATIC S.r.l
32026 Borgo Valbelluna – Belluno – Italy
Via dell’Artigiano, n°1 – Z.A.
Tel. 0437 751175 – 751163 r.a. Fax 0437 751065
http://www.allmatic.com – E-mail:
info@allmatic.com
Read User Manual Online (PDF format)