CAL-ROYAL CR3361 Carpet Special Purpose Threshold
INSTALLATION INSTRUCTIONS
- Measure width at the bottom of the frame and cut the threshold to exact full width of the opening.
- If necessary trim and notch the threshold ends to accommodate the side jamb stops
- Mark and drill pilot holes through the pre-drilled holes in the threshold and fasten with screws provided.
- Seal both ends and along the sides of the threshold.
- Operate the door multiple times to ensure proper adjustment so as not to prevent the door from self-closing and latching.
MATERIAL FOR USE IN LISTED STEEL FRAMES AND CLASSIFIED HOLLOW METAL STEEL COMPOSITE TYPE FIRE DOORS ARE RATED UP TO AND INCLUDING 3 HOURS, WOOD COMPOSITE TYPE FIRE DOORS ARE RATED UP TO AND INCLUDING 1-1/2 HOURS, AND WOOD CORE FIRE DOORS ARE RATED 20 MINUTES WITHOUT HOSE STREAM.