ALLMATIC BIOS1 Programmable Control Board For Sliding Gates Installation Guide
- June 13, 2024
- ALLMATIC
Table of Contents
BIOS1 Programmable Control Board For Sliding Gates
Product Information:
The CONTROL UNIT BIOS1 is a programmable control board designed
for sliding gates. It is compatible with firmware version
BIOS1BT04. The control unit is equipped with various accessories
and safety devices to ensure efficient and safe operation.
Product Usage Instructions:
-
Installation: Before installing the control
unit, it is essential to read the instructions carefully. The
installation should only be performed by qualified personnel. -
Configuration: Ensure that the following
accessories and components are properly connected and adjusted:-
FUSE: Use a 0.5 A fuse for accessories and a 6.3 A fuse for the
power line. -
BLUETOOTH MODULE: Connect the Bluetooth module to the
designated connector. -
MEMORY: Utilize the memory function as required.
-
DIP SWITCH: Adjust the DIP switch settings according to the
desired configuration. -
ANT. C.A.: Connect the antenna for remote control
reception.
-
-
Connections: Connect the various components as
follows:-
MOTOR OUTPUT: Connect the motor common, phase 1, and phase 2 to
the corresponding clamps on the control unit. -
MOTOR CONDENSERS: Connect the motor capacitors to the
designated clamps on the control unit. -
LIMIT SWITCHES: Connect the normally closed contacts of the
limit switches to the control unit. -
POWER SUPPLY: Connect the power supply cable between clamp 1
and 2 of the control unit. Ensure proper disconnection from the
electric network. -
COURTESY LIGHT OUTPUT: Connect the courtesy light to clamps 3
and 4. -
FLASHING LIGHT OUTPUT: Connect the flashing light to clamps 3
and 5. -
PHOTOCELLS POWER SUPPLY: Connect the control unit’s clamp 6 to
the power supply of the photocells receiver. Connect clamp 7 to the
power supply of the photocells receiver and transmitter. Connect
clamp 8 to the power supply of the photocells transmitter. -
SAFETY EDGE INPUT: Connect the safety edge contacts to clamps 9
and 10. -
OPENING PHOTOCELL INPUT: Connect the normally closed contact of
the photocell (PHOTO 2) between clamps 11 and 18. -
CLOSING PHOTOCELL INPUT: Connect the normally closed contact of
the photocell (PHOTO 1) between clamps 12 and 18.
-
Please refer to the advanced menu for additional configuration
options and settings. For specific safety edge and photocell tests,
consult the respective manuals. Always ensure proper electrical
safety precautions when working with the control unit.
Compatible from firmware version BIOS1BT04
CONTROL UNIT BIOS1
Programmable Control board for sliding gates
Manual for installation
Compatible from firmware version BIOS1BT04
1. Introduction
The control unit BIOS1 is particularly indicated for the installation of 1 230
Vac motor with maximum power absorbed of 700W. The control unit equipped with
a display that allows a precise regulation of the thrust and sensitivity. The
control unit can memorize up to 8000 transmitters with the external memory,
with the step by step, partial opening, open and close functions. It is
supplied with inputs for interior and exterior photocell, possibility to
connect the buttons for step by step, partial opening, open, close and stop.
The outputs include a 230 Vac flashing light, courtesy light/zone light/ open
gate light, 24 Vdc accessories power supply.
ATTENTION: DO NOT INSTALL THE CONTROL UNIT WITHOUT READING THE INSTRUCTIONS
FIRST !!! THE INSTALLATION SHOULD BE PERFORMED ONLY BY QUALIFIED PERSONNEL.
2. Configuration
Accessories FUSE
F 0.5 A
Be sure that the limit switches are connected and correctly adjusted
Line FUSE
F 6.3 A
CONNECTOR FOR BLUETOOTH MODULE
MEMORY
SAFETY DEVICES
DIP SWITCH
ANT. C.A.
3. Connections
MOTOR OUTPUT Connect the common of the motor to the clamp motor COM of the control unit. Connect the phase 1 of the motor to the clamp motor L1 of the control unit. Connect the phase 2 of the motor to the clamp L2 of the control unit.
Motor condensers 230 Vac !Risk of electric shock!
CAPACITOR Connect the capacitor to the clamps COND of the control unit.
LIMIT SWITCHES Connect the NORMALLY CLOSED contact of the limit switches to the control unit
During the learning of the stroke phase the control unit recognize itself the
opening and closing limit
switch.
6-1622241 rev.8 12/09/2022
ITA ENG FRA ESP DEU POR
2 / 12
Compatible from firmware version BIOS1BT04
POWER SUPPLY Connect the power supply cable between clamp 1 and 2 of the control unit
Power supply 230 Vac 50 Hz Do not connect the card directly to the electric
network. Put a device which can ensure the disconnection of each pole from the
power supply of
the control unit.
COURTESY LIGHT OUTPUT Connect the courtesy light to the clamps 3 and 4, 230Vac
100W MAX.
FLASHING LIGHT OUTPUT Connect the flashing light to the clamps 3 and 5.
It is possible to light up the action area of the automatism during each
motion. The functioning of the auxiliary light is controlled in the advanced
menu .
Use a flashing light without self flashing card 230Vac 60W MAX
PHOTOCELLS POWER SUPPLY Connect the clamp 6 of the control unit to the clamp + of the power supply of the photocells receiver. Connect the clamp 7 of the control unit to the power supply clamp – of the photocells receiver and of the transmitter. Connect the clamp 8 of the control unit to the power supply clamp of the trasnmitter of the photocells.
The photocells test is activated in the advanced menu . ATTENTION: the control
unit gives a voltage of 24 Vdc and can supply a maximum power of 4W.
For the safety edge test connect the test device of the safety edge on the
power supply pins of the TX (test activated wiht low logic signal 0Vdc).
Please refer to the manual of the safety edge.
SAFETY EDGE INPUT Connect the safety edge contacts to the clamps 9 and 10 of
the control unit.
OPENING PHOTOCELL INPUT Connect the NORMALLY CLOSED contact of the photocell
(PHOTO 2) between the clamps 11 and 18 of the control unit.
Select the type of security edge used (mechanical or 8K2) through the menu ,
select the type of functioning through the menu. If not used set the DIP
switch EDGE ON.
The functioning of the opening photocell is controlled in the advanced menu .
If not used set the DIP switch PH2 ON.
CLOSING PHOTOCELL INPUT Connect the NORMALLY CLOSED contact of the photocell (PHOTO 1) between the clamps 12 and 18 of the control unit.
The functioning of the closing photocell is controlled
in the advanced menu . If not used set the DIP switch PH1 ON.
STOP INPUT Connect the NORMALLY CLOSED contact of the STOP between the clamps 13 and 18 of the control unit.
If not used set the DIP switch STOP ON.
OPEN INPUT Connect the button OPEN between the clamps 14 and 18 of the control unit.
CLOSE INPUT Connect the button CLOSE between the clamps 15 and 18 of the control unit.
PARTIAL OPENING INPUT Connect the button PED between the clamps 16 and 18 of the control unit.
6-1622241 rev.8 12/09/2022
STEP BY STEP INPUT Connect the button SS between the clamps 17 and 18 of the control unit.
ANTENNA Connect the signal cable of the antenna to the
clamp 19 and the ground of the antenna to the clamp 20 of the control unit.
The presence of the metallic parts or humidity in the walls could have
negative influences on the range
of the system. We suggest therefore to not place the receiving antenna and/or
transmitters near big
metallic objects, near the floor or on the ground.
ITA ENG FRA ESP DEU POR
3 / 12
Compatible from firmware version BIOS1BT04
4. Remote control learning
4.1 Learning of one transmitter
The 1st memorized button performs the STEP by STEP function (opening and
closing of the gate), the 2nd button performs the partial opening, the 3rd
button performs the OPEN function, 4th button performs the CLOSE function. The
control unit exits from the learning phase if no new button or trasnmitter
command is given in 10 seconds.
1
Make sure that the board is out of any menus, press the button UP[+]
On the display will appear and the flashing light lights on
Press one button of the transmitter 2
If you want to memorize another button or a new transmitter repeat the
procedure
On the display will appear . If the transmitter was already
memorized will appear . After 2 seconds the display will show the memory
location of the memorized transmitter, for example
4.2 Learning with the hidden button of an already memorized transmitter
With the hidden button of a transmitter it is possible to enter the learning
phase in order to memorize new buttons or new transmitters. With the
automation still, with the aid of a clip press the hidden button of an already
memorized transmitter, the flashing light lights on, now it is possible to
memorize new buttons or transmitters.
4.3 Cancellation of one transmitter
Enter the learning phase with the UP[+] button or with the hidden button of a
memorized transmitter (see 4.1 or 4.2). Press in the same time the hidden
button and 1st button of the transmitter that you want to cancel. The flashing
light bilnks 4 times and on the display will appear
5. Setting stroke 5.1 Easy settings of the stroke (parameter )
Be sure that the limit switches are connected and correctly adjusted
1
Unlock the gate and move it to the middle of the stroke
Press and keep pressed the buttons UP[+] e MENU
2
for at least 5 seconds.
3
When the gate reaches the opening limit switch it stops by itself
4
When the gate reaches the closing limit switch it stops by itself
5
When the gate reaches the opening limit switch it stops by itself
The gate moves in opening. If the gate moves in closing press the button DOWN
to stop and reverse the direction of movement and give a step by step command
(SS) to resume the procedure
The gate moves in closing
The gate moves in opening
The gate closes with the settings of slowing down set in the menu. When the
gate is closed the learning phase is ended.
Warning: in case of intervention of a safety device, the learning is stopped and will appear on the display the written Press Step by Step button to start again the learning from the 2nd point.
6-1622241 rev.8 12/09/2022
ITA ENG FRA ESP DEU POR
4 / 12
Compatible from firmware version BIOS1BT04
5.2 Advanced settings of the stroke (parameter = )
Be sure that the limit switches are connected and correctly adjusted In this
procedure is necessary to provide the positions of beginning of slowing down
with a step by step command (SS).
1
Unlock the gate and move it to the middle of the stroke
Press and keep pressed the buttons UP[+] e MENU
2
for at least 5 seconds.
3
When the gate reaches the opening limit switch it stops by itself
4
When the gate reaches the position of beginning of slowing down give a step by step command (SS)
5
When the gate reaches the closing limit switch it stops by itself
6
When the gate reaches the position of beginning of slowing down give a step by step command (SS)
7
When the gate reaches the opening limit switch it stops by itself
The gate moves in opening. If the gate moves in closing press the button DOWN
to stop and reverse the direction of movement and give a step by step command
(SS) to resume the procedure
The gate moves in closing
The gate begins the slowing down
The gate moves in opening
The gate begins the slowing down
The gate closes with the settings of slowing down set in this learning. When
the gate is closed the learning phase is ended.
Warning: in case of intervention of a safety device, the learning is stopped and will appear on the display the written Press Step by Step button to start again the learning from the 2nd point.
6-1622241 rev.8 12/09/2022
ITA ENG FRA ESP DEU POR
5 / 12
Compatible from firmware version BIOS1BT04
6. Menu
Entering the menu: To enter the base menu settings keep pressed the MENU
button for at least one second To enter the advanced menu settings keep
pressed the MENU button for at least five seconds
Navigation into the menu: It is possible to move from an entry to another one
using UP[+] e DOWN[-] buttons, To change a parameter keep pressed the MENU
button for at least 1 second until the parameter begins blinking, so release
the button. Use UP[+] and DOWN[-] buttons to change the parameter At the end
keep pressed MENU for al least 1 second until the parameter stops blinking to
save the change.
A quick pressure of the menu button is enough to leave a menu
Ex. Base menu Ex. Advanced menu
6.1 Base settings menu:
MENU
DESCRIPTION
Auto reclosing time (0 = disabled)
SELECTABLE VALUES min-max 0-900
DEFAULT UNITS
0
s
Auto reclosing time after transit(0 = disabled)
0-30
0
s
Obstacle sensitivity (0 = disabled 100 = maximum sensitivity)
0-100
0
%
Motor torque (running torque)
Slowing down mode 0 = normal 1 = fast with more torque
Step by step configuration 0 = normal (OP-ST-CL-ST-OP-ST…) 1 = alternated STOP
(OP-ST-CL-OP-ST-CL…) 2 = alternated (OP-CL-OP-CL…) 3 = condominium timer 4 =
condominium with immediate auto reclosing
After black-out 0 = no action 1 = closing
Soft start 0 = disabled 1 = enabled
Amplitude of slowing down P = personalized during learning 0…100% = percentage
of stroke
Deceleration ramp amplitude 0 = disabled 1:9 = ramp duration
10-100 0-1
0-4
0-1 0-1 0-100 0-9
100
%
0
0
0
0
15
%
5
*ATTENTION!
It is not advisable the disabling of the slowing downs and, if possible, use
the “soft start” function.
6-1622241 rev.8 12/09/2022
ITA ENG FRA ESP DEU POR
6 / 12
Compatible from firmware version BIOS1BT04
6.2 Advanced menu:
MENU
DESCRIPTION
First coupling between Bluetooth device and control unit
..
Electrical brake activation time
0 = disabled 1 – 100= enabled
..
Functioning of PHOTO1 moving from closed
0 = Check PHOTO1 1 = The gate opens also with PHOTO1 busy
..
Functioning of PHOTO2
0 = Enabled in opening and closing OP/CL 1 = Enabled only in opening OP
..
Photocells test 0 = disabled
1 = enabled PHOTO1 2 = enabled PHOTO2
3 = enabled PHOTO1 and PHOTO2
. . Safety edge type
0 = contact (NC)
1 = resistive (8k2)
..
Operation mode of safety edge
0= working only in closing with inversion of movement
1 = stops the automation (both opening and closing) and free the obstacle
(short inversion)
Safety edge test
.. 0 = disabled 1 = enabled
.. Partial opening
. . Auto reclosing time from partial opening (0 = disabled)
Blinker output mode
.. 0 = Fix 1 = Blinking
. . Pre-flashing time (0 = disabled)
..
Courtesy ligth settings 0 = At the end of movement for a TCY time
1 = On if the gate is not closed + TCY time
2 = On if courtesy light timer (TCY) not expired 3 = Open gate light on/off
4 = Open gate light with proportional flashing
. . Courtesy light time
.. .. ..
Dead-man 0 = disabled 1 = enabled
Setting threshold of cycles for assistance request. Once limit is reached the
next cycles will be done with fast blinking (only if enabled) (0 = disabled)
Continuous blinking for assistance request (done only with closed gate). 0 =
disabled 1 = enabled
Viewing of the memory location for a single transmitter
Cancellation of a single transmitter
.. ..
Restore defaul settings, enter to modify the parameter and then keep pressed
the MENU button, a count down appears that ends with on the display
Cancelling all transmitters, enter to modify the parameter and then keep
pressed the MENU button, a count down appears that ends with on the display
SELECTABLE VALUES min-max
DEFAULT UNITS
0-100 0-1 0-1
0-3
0-1 0-1 0-1 0-100 0-900 0-1 0-10
0-4
0-900 0-1
0-100 0-1
0-999 0-999
0
x0.01 s
1
0
0
0
0
0
30
%
20
s
1
0
s
0
0
s
0
0
x1000 cicli
0
6-1622241 rev.8 12/09/2022
ITA ENG FRA ESP DEU POR
7 / 12
Compatible from firmware version BIOS1BT04
6.3 Menu description: 6.3.1 Base settings menu
Auto reclosing time
Active when the gate is in the completely open position, the gate
automatically closes after seconds. In this phase the display shows with the
blinking dash, that during the last 10 seconds will be replaced by the count
down.
Auto reclosing time after transit
If in the opening phase or in the completely open position the beam of the photocells is obscured and freed, the gate automatically closes after
seconds when the completely open position is reached, In this phase the display shows seconds will be replaced by the count down.
with the blinking dash, that during the last 10
Obstacle sensitivity
Adjust the obstacle sensitivity to ensure a correct functioning of the gate,
it must stop if there is an obstacle but also it must ensure the complete
movement in the worst conditions (exp. winter, hardening of motors, etc).
After the adjustement of this parameter it is recommended to perform a
complete movimentation (opening and closing) before trying the obstacle
detection. The intervention of the obstacle sensitivity stops the gate and
makes a short inversion of the movement.
Motor torque
Adjust the motor torque to ensure a correct functioning of the gate, it is
possible to adjust the percentage of torque between 10% to 100%. After the
adjustement of this parameter it is recommended to perform a complete
movimentation (opening and closing) to ensure a correct functioning of the
gate.
Slowing down mode The control unit has 2 different type of slowing downs : standard or with higher torque and speed, for heavier gates.
Step by step configuration (SS)
·
= 0 Normal (OP-ST-CL-ST-OP-ST…)
Typical functioning of Step by Step. During the movement a SS command stops the gate.
·
= 1 Alternated STOP (OP-ST-CL-OP-ST-CL…)
Alternated functioning with STOP during the opening. During the opening phase a SS command stops the gate.
·
= 2 Alternated (OP-CL-OP-CL…)
The user cannot stop the gate during the movement with a SS command.
A SS command during the movement inverts the movement.
·
= 3 Condominium timer
A SS command only opens the gate. When the gate is completely open, if the command persist the control unit will wait until the opening of
the contact before beginning the contdown of the automatic reclosing (if enabled), onother SS command in this phase will restart the contdown of the automatic reclosing.
·
= 4 Condominium with immediate auto reclosing
Like condominium timer (previous point) but during the countdown a SS command will close the gate.
After black-out When the control unit turns on after a black-out,
·
= 0 No action when the control unit turns on the gate doesn’t move until the first command, the first movement is a slow opening.
·
= 1 Closing turning on the control unit it will perform a slow closing.
-
Soft start The movement begins with reduced torque, used in light gates.
-
Amplitude of slowing down With this parameter it is possible to adjust the amplitude of the slowing down and eventually disable it (=0). If you need more precise or different slowing down between opening and closing it is possible to set the parameter on (personalized) and perform an advanced learning of strokes (5.2) providing also the beginning of slowing downs during the learning.
Deceleration ramp amplitude With this parameter it is possible to define the amplitude of the deceleration ramp and possibly its exclusion ( = 0). It allows performing a deceleration from cruising speed to the retarding speed, more or less evident depending on the installation requirements.
*ATTENTION!
It is not advisable the disabling of the slowing downs and, if possible, use
the “soft start” function.
6-1622241 rev.8 12/09/2022
ITA ENG FRA ESP DEU POR
8 / 12
Compatible from firmware version BIOS1BT04
6.3.2 Advanced menu
.. Bluetooth Item of the menu needed to the first coupling between an Android device and the control unit. Refer to the Help of the Android application for the connection procedure.
.. Electrical brake
Short reverse movement with reduced torque to reduce the inertia of the gate.
The operation is performed at each stop of the movement except for fast
movement after the intervention of a safety devices.
.. Functioning of closing photocell PHOTO1 moving from closed position The closing photocell has the following functioning
·
Closing: immediate inversion of movement
·
Opening from an intermediate position: no intervention
·
Opening from closed position:
.. = 0 The gate doesn’t move if PHOTO1 beam is cut
.. = 1 The gate moves while PHOTO1 beam is cut
.. Functioning of opening photocell PHOTO2 The opening photocell has the following functioning
·
Opening: stops the movement and waits until the beam is freed, then moves in opening.
·
Closing:
.. = 0 Stops the movement and waits until the beam is freed, then moves in opening
.. = 1 No intervention
.. Photocells test
Enabling this function, before each movement starting from still gate, the
control unit performs a functional check of the photocells. The check will not
be performed in case of fast movement after the intervention of a safety
devices. Follow paragraph 3.6 for the connections of the photocells.
.. Safety edge type The control unit can work with two different type of safety edge:
·
..= 0 Mechanical with normally closed contact
·
..= 1 Resistive 8k2
.. Operation mode of safety edge To allow the installation of the safety edges in both the directions of movements, it is possible to choose 2 different functioning:
·
..= 0 Only in closing with total inversion of movement
·
..= 1 Both directions of movements, stop and short inversion to free the obstacle
.. Safety edge test
Enabling this function the control unit performs a functional check of the
safety edge. This function is used if the edge connected to the control unit
has an electronic self test (exp. radio edge R.CO.O). Connect the test contact
of the edge to the power supply of the trasmitter of the photocells
(paragraph 3.6) ad enable the self test with low voltage 0Vdc (for the
compatibility follow the instruction of the manual of the safety edge).
.. Partial opening Partial opening can be performed only starting from closed. The parameter sets the opening like a percentage of the total stroke of the first wing.
.. Auto reclosing time from partial opening
Active when the gate is in the partial opening, the gate automatically closes
after .. seconds. In this phase the display shows with the blinking dash, that
during the last 10 seconds will be replaced by the count down.
.. Flashing light output mode It is possible to choose 2 different functioning for the blinker output:
·
.. = 0 Fixed blinker output. It will be necessary to connect a self flashing blinker (B.RO LIGHT 230 Vac)
·
.. = 1 Flashing light blinker output. It will be necessary to connect a fix light blinker (B.RO LIGHT FIX 230 Vac)
.. Pre-flashing time Pre-flashing before each movement in both directions, .. seconds of pre-flashing
.. Courtesy light settings The control unit has 4 different functionings for courtesy light:
·
.. = 0 the light switches off at the end of a movement after .. seconds
·
.. = 1 the light switches off only with closed gate after .. seconds
·
.. = 2 lighted on for .. seconds from the beginning of a movement, indipendently of the condition of the gate
·
(the light could switch off before the end of movement)
·
.. = 3 open gate light – the light switches off immediately when the gate reaches the closed position
·
.. = 4 open gate light with proportional blinking:
opening slow blinking
closing fast blinking
opened light on
closed light off
stopped 2flash + long wait + 2flash + long wait +…
.. Courtesy light timer Courtesy light activation timer
6-1622241 rev.8 12/09/2022
ITA ENG FRA ESP DEU POR
9 / 12
Compatible from firmware version BIOS1BT04
.. Dead man
During dead man functioning mode the gate moves only with a permanent command.
The enabled commands are OPEN and CLOSE. SS and PED are disabled. During dead
man functioning all the automatic movements are disabled,
like short or total inversions. All safety devices are disabled except for
STOP.
.. Setting threshold of cycles for assistance request It is possible to set a
number of cycles before the request of assistance. Once the limit is reached
the next cycles will be done with fast blinking (only if
enabled)
.. Continuous flashing light for assistance request Once limit .. is reached the flashing light will blink also with the gate closed to show the request of assistance.
.. Viewing of the memory position for a single transmitter
With the item of the menu .. it is possible to view the memory location in
which a transmitter is memorized.
To perform the function, move to .. and then confirm by pressing the button
MENU. Keep pressed MENU button untill the display will show then release the
button.
At this point press a button of the memorized transmitter (it does not active any command). The display shows:
·
the memory location for 2 seconds, if is memorized;
·
the written
for 2 seconds, if is not memorized.
After 2 seconds the display returns to the screen
and it will be possible to perform this function with another transmitter.
To exit from the function, press MENU button. Otherwise after 15 seconds without transmission, the control unit exits from the function and shows the
written
.. Cancellation of a single transmitter
With the item of the menu .. it is possible to delete a single transmitter from the memory.
To perform the function, move to .. and then confirm by pressing the button MENU. Keep pressed MENU button untill the display will show 0, then
release the button. Select the memory location of the transmitter. Press and keep pressed MENU button untill the display will show
, then
release the button.
To exit from the function, press MENU button. If the display shows the written position or disconnected memory).
, there are problems with the memory (for example empty
.. Restore default settings With this parameter it is possible to restore the
default settings of the control unit. The reset will restore all the
parameters of the base and advanced menu, but doesn’t modify the learnt
strokes, the directions of motors and the transmitters.
Move to .. then keep pressed MENU button until the display shows 0, release
the button. Press again and keep pressed MENU button, the display
will show a count down ,,…,,don’t release the button until the display showns
.. Erasing of all transmitters With this parameter it is possible to erase all
the transmitters learnt.
Move to .. then keep pressed MENU button until the display shows 0, release
the button. Press again and keep pressed MENU button, the
display will show a count down ,,…,,don’t release the button until the display
showns
7. Display and control unit state 7.1 Input LED and safety devices
RED (normally on) RED (normally on) RED (normally on) RED (normally on) GREEN (normally off) GREEN (normally off) GREEN (normally off) GREEN (normally off)
6-1622241 rev.8 12/09/2022
ITA ENG FRA ESP DEU POR
10 / 12
7.2 Normal functioning:
Standby – Gate closed or after the switch on of the control unit
Opening phase
Closing phase
Gate closed by user during opening
Gate closed by user during closing
Gate stopped by an external event (photocells, stop)
Gate opened without automatic reclosing
Gate opened in partial opening position without automatic reclosing
Gate opened waiting for auto reclosing, last 10 seconds the dash will be
replaced by the countdown Gate opened in partial opening position waiting for
auto reclosing, last 10 seconds the dash will be replaced by the countdown
During the normal functioning and out from any menu, the pression of the
DOWN[-] button lets you see the number of cycles done, you will see units with
dots on the bottom of display and thousand without dot, another pression of
DOWN[-] or MENU button let you to leave the cycles visualization
Visualized during the learning of transmitters
Visualized when memorized a new transmitter or at the and of a reset
Visualized when memorized a button of a transmitter already memorized
Visualized when a trasmitter is erased Visualized during the learnign of
strokes to indicate that the control unit is opening the gate and waiting for
the command of opening mechanical stop Visualized during the learning of
strokes to indicate that the control unit is clkosign the gate and waiting for
the command of closing mechanical stop Visualized during the learning of
strokes if there is an intervention of safety devices Visualized when the
control unit waits a transmitter signal, during the function of viewing of the
memory location. Visualized when the transmitter is not stored on the memory,
during the function of viewing of the memory location. Visualized when the
control unit exits from the function of viewing of the memory location for
inactivity.
Visualized during the first coupling with the Bluetooth device.
Visualized when the control unit is connected to a Bluetooth device
Visualized when Bluetooth device is disconnecting from the control unit.
7.3 Errors:
Impact sensor intervention Safety edge intervention Limit switches error (both
opening and closing electrical limit switches busy in the same time)
Malfunctioning of photocells Thermical intervention to preserve the control
unit Memory error Full memory Memory error during functions viewing memory
location or cancellation of a single transmitter The visualization of an error
on the display persist until another command is given
6-1622241 rev.8 12/09/2022
ITA ENG FRA ESP DEU POR
11 / 12
Compatible from firmware version BIOS1BT04
Compatible from firmware version BIOS1BT04
8. Technical features
POWER SUPPLY AND CONSUMPTION Power supply voltage Absorption from line
(Standby) Standard configuration (2 couple of photocells, RX radio safety
edge) Line fuse
MOTOR POWER SUPPLY Number of motors Motor power supply voltage Maximum power
absorbed from motors
ACCESSORIES POWER SUPPLY Accessories power supply voltage Maximum current
absorbed from accessories Maximum power absorbed from accessories Accessories
fuse Blinker output Courtesy light output / open gate light
FUNCTIONALITY 433 MHz radio receiver Maximum transmitters Safety edge input
230 Vac – 50/60 Hz 45 mA @ 230 Vac
F6.3A
1 230 Vac – 50/60 Hz
700W
24 Vdc 170 mA
4 W F 0.5 A 230 Vac 60W max 230 Vac 100W max
Rolling code 1000 (up to 8000)
NC / 8k2
DISPOSAL OF THE PRODUCT This product is an integral part of the automation,
and therefore, they must be disposed of together. As for the installation
operations, at the end of the life of this product, the dismantling operations
must be performed by qualified personnel. This product is made from different
types of materials: some can be recycled, others must be disposed of. Please
inform yourselves on the recycling or disposal systems provided for by the
laws in force in your area, for this category of product.
CAUTION! some parts of the product can contain polluting or dangerous
substances which, if dispersed in the environment, may cause serious harm to
the environment and human health. As indicated by the symbol at the side, it
is forbidden to throw this product into domestic refuse. Therefore, follow the
“separated collection” instructions for disposal, according to the methods
provided for by local regulations in force, or redeliver the product to the
retailer at the moment of purchase of a new, equivalent product. CAUTION!
the regulations in force at local level may envisage heavy sanctions in case
of abusive disposal of this product.
GUARANTEE – In compliance with legislation, the manufacturer’s guarantee is
valid from the date stamped on the product and is restricted to the repair or
free replacement of the parts accepted by the manufacturer as being defective
due to poor quality materials or manufacturing defects. The guarantee does not
cover damage or defects caused by external agents, faulty maintenance,
overloading, natural wear and tear, choice of incorrect product, assembly
errors, or any other cause not imputable to the manufacturer. Products that
have been misused will not be guaranteed or repaired. Printed specifications
are only indicative. The manufacturer does not accept any responsibility for
range reductions or malfunctions caused by environmental interference. The
manufacturer’s responsibility for damage caused to persons resulting from
accidents of any nature caused by our defective products, are only those
responsibilities that come under Italian law.
ALLMATIC S.r.l 32026 Borgo Valbelluna – Belluno Italy
Via dell’Artigiano, n°1 Z.A.
Tel. 0437 751175 751163 r.a. http://www.allmatic.com
E-mail: info@allmatic.com
6-1622241 rev.8 12/09/2022
ITA ENG FRA ESP DEU POR
12 / 12