TONOR TW840 UHF Wireless Microphones System Instruction Manual
- June 14, 2024
- TONOR
Table of Contents
TONOR TW840 UHF Wireless Microphones System Instruction Manual
UHF Wireless Microphone Instruction Manual
TW840
ABOUT THIS MANUAL
Thank you for purchasing TONOR wireless microphone. This manual is intended to help you understand all about this microphone and how to use it. TONOR always strives for the ultimate user experience. All our knowledge and passion for audio technology are incorporated into building microphones with high performance for you. The TONOR microphone is high quality and easy to use to achieve the best user experience.
Enjoy your microphone!
TONOR Team
Package Including
OPERATING ENVIRONMENTS & NOTES
When using this device, keep it away from water.
Use the device in ventilated environment, keep it away from fire.
Since it’s a wireless device, please keep it away from other interfering sources.
Don’t take apart the device.
Please use the standard power supply, high voltage may damage the device.
Please place the used batteries into the recycle bin, don’t litter them.
SPECIFICATIONS
Frequency Response: 40hz-18khz
Operating Frequency: 902.8-926.8MHz
Operating Range: Up to 60m
Frequency Stability: ±10ppm
SNR: 96dB
Sound Distortion: 0.03%
Mic Input Sensitivity: -52dB±3dB
RF Sensitivity: -95dBm
Operating Temperature: 0˚C to +55˚C
MICROPHONE OPERATION INSTRUCTION
As shown in the pictures:
- Display Screen
- On/Off Switch
- Tail Tube
- HI-LO Button
- Battery Compartment
Install 2*AA batteries before using the wireless microphone and installing instruction is as follows:
- Take down the tail tube of mic.
- Install the batteries and tighten tail tube of mic.
Note: The positive and negative polarity of battery cannot be reversed.
Instruction:
-
Press button 2 to turn on. Long press for 2 seconds to turn off.
-
Press the HI-LO button 4, then the frequency on the screen wilI be changed.
RECEIVER INSTRUCTION
- Receiving antenna
- Volume adjusting button for microphone A
- LCD display screen for microphone A and B
- Volume adjusting button for microphone B
- Power switch (Long press for 2 seconds to turn on/off)
- Volume adjusting button for microphone C
- LCD display screen for microphone C and D
- Volume adjusting button for microphone D
As shown in above pictures:
- ANT D
- ANT C
- BAL D
- BAL C
- MIX
- BAL B
- BAL A
- ANT B
- ANT A
- DC IN
Before using the device, take out the wireless receiver from the package, and connect the following cables: firstly use the 6.35 audio cable to connect the receivers MIX’s port and other audio devices (speaker, amplifier, mixer, etc,). Secondly, erect the antenna, and connect the power cable. Thirdly, check if microphone is connected to the receiver successfully after turning on the device.
RECEIVER DISPLAY SHOWS
As shown in above pictures:
- Signal levels of mic A
- Volume levels of mic A
- Signal receiving of mic A
- Current channel of mic A
- Current frequency of mic A
- Signal levels of mic B
- Volume levels of mic B
- Current channel of mic B
- Signal receiving of mic B
- Current frequency of mic B
As shown in above pictures:
- Signal levels of mic C
- Volume levels of mic C
- Signal receiving of mic C
- Current channel of mic C
- Current frequency of mic C
- Signal levels of mic D
- Volume levels of mic D
- Current channel of mic D
- Signal receiving of mic D
- Current frequency of mic D
When the receiver is connected to power supply successfully, but the batteries of microphone are not installed, LCD screen will display as following pictures:
When the receiver is connected to power supply successfully, and the batteries of microphone are also installed, LCD screen will display as following pictures:
TROUBLESHOOTING
No sound (The batteries of microphone have already been installed, but one of the microphone has on sound.)
Please turn off the microphone which can work normally, and you will find that the RF light on the receiver will disappear. Then follow the steps below to pair the micophone (no sound) with the receiver.
- Make sure that the receiver and microphone are turned OFF.
- Unscrew the microphone tail tube and install the batteries into the mic’s battery compartment.
- Make sure that the microphone is OFF, press and hold the HI/LO button and the power button simultaneously, do not release them, until the microphone screen flashes quickly, then release two buttons simultaneously.
- Turn on the receiver’s power button, wait for 5 seconds or so, then press the HI/LO button (on the microphone) once, until the microphone screen becomes steady and no longer flashes, the RF light on the receiver turns steady, indicating that the pairing is successful.
- Tum off the microphone, then tighten the microphone tail tube. Pairing is now completed.
Received signal with noise or interference
Change to other channels;
Check if receiving distance exceeds the maximum range.
Microphone cannot be tumed on
Check if batteries are installed reversely;
Change to new batteries.
WARRANTY
TONOR provides 2 years of after-sales service, free replacement to products that are NOT damaged resulting from accident, alteration, misuse, negligence, or abuse. If exceeding 30 days of Amazon return policy, you can still contact us through our Shopify TONORMIC. We will serve you with full sincerity!
FCC STATEMENT: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
EASTWEST ELECTRONIC COMMERCE CO., LIMITED
LEVEL 54 HOPEWELL CENTRE 183 QUEEN’S ROAD
EAST HONG KONG
EASTWEST ELECTRONIC COMMERCE CO US LIMITED
3500 SOUTH DUPONT HIGHWAY, SUITE G106
DOVER, DE 19901 UNITED STATES
LIFEWIT LIMITED
FLAT 237, 233 HIGH STREET CROYDON SURREY
ENGLAND CR0 1FY UNITED KINGDOM
Lifewit GmbH
Friedenstraße 5 97072 Wuerzburg Germany
MADE IN CHINA
References
- EU Declaration of Conformity – TONOR
- Professional USB Microphone and Wireless Microphone – TONOR
- EU Declaration of Conformity – TONOR
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>