TONOR TW450 UHF Wireless Microphone User Manual

June 14, 2024
TONOR

TONOR TW450 UHF Wireless Microphone User Manual
TONOR TW450 UHF Wireless Microphone

Thank you for purchasing TONOR wireless microphone. This manual is intended to help you understand all about this microphone and how to use it. TONOR always strives for the ultimate user experience. All our knowledge and passion for audio technology are incorporated into building microphones with high performance for you. The TONOR microphone is high quality and easy to use to achieve the best user experience.

Enjoy your microphone!

TONOR Team

OPERATING ENVIRONMENTS & NOTES

When using this device, keep it away from water.

Use the device in ventilated environment, keep it away from fire.

Since it’s a wireless device, please keep it away from other interfering sources. Don’t take apart the device.

 Please use the standard power supply, high voltage may damage the device.

Please place the used batteries into the recycle bin, don’t litter them.

SPECIFICATIONS

Frequency Response: 40hz-18khz
Maximum Radio-frequency Power Transmitted: 8.5 dBm
Operating Frequency(US): A MIC: 902.8-914MHz, B MIC: 915.6-926.8MHz
Operating Frequency(UK/EU): A MIC: 823-826.2MHz;B MIC: 827.8-831MHz
Operating Range: Up to 60m
Frequency Stability: ±10ppm
SNR: 96dB
Sound Distortion: 0.03%
Mic Input Sensitivity: -52dB±3dB
RF Sensitivity: -95dBm
Operating Temperature: 0ºC to +55ºC

MICROPHONE OPERATION INSTRUCTION

As shown in the pictures:

  1. Display Screen
  2. On/Off Switch
  3. Tail Tube
  4. HI-LO Button
  5. Battery Compartment
    Product Overview

*Install 2AA batteries before using the wireless microphone and installing instruction is as follows:**

  1. Take down the tail tube of mic.
  2. Install the batteries and tighten tail tube of mic.

Note: The positive and negative polarity of battery cannot be reversed.
Product Overview

Instruction:

  1. Press button 2 to turn on. Long press for 2 seconds to turn off.
  2. Press the HI-LO button 4, then the frequency on the screen wilI be changed.
    Product Overview

EU Declaration of conformity

RoHS Directive (2011/65/EU)

Hereby, Fujian East West Life wit Technology Co., LTD declares that the radio equipment type TW450 is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address:

https://www.tonormic.com/pages/eu-declaration-of-conformity

Conditions and restrictions for using frequencies

Conditions and restrictions for using frequencies There may be special conditions and restrictions for using frequencies in your country. Before putting the product into operation, find the information for your country at the following address:
https://www.tonormic.com/pages/permitted-frequency-bands

FCC Statement

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference.
  2. This device must accept any interference received, including interference that may cause undesired operation.

Frequency Range (US)

A MIC| 902.8-914MHz(902.8MHz, 903.6MHz, 904.4MHz, 905.2MHz, 906.0MHz, 906.8MHz, 907.6MHz, 908.4MHz, 909.2MHz, 910.0MHz,910.8MHz, 911.6MHz, 912.4MHz, 913.2MHz, 914MHz)
B MIC| 915.6-926.8MHz(915.6MHz, 916.4MHz, 917.2MHz, 918.0MHz, 918.8MHz, 919.6MHz, 920.4MHz, 921.2MHz, 922.0MHz, 922.8MHz,923.6MHz, 924.4MHz, 925.2MHz, 926.0MHz, 926.8MHz)
Frequency Range (UK/EU)
A MIC| 823-826.2MHz(823MHz, 823.8MHz, 824.6MHz, 825.4MHz, 826.2MHz)
B MIC| 827.8-831MHz(827.8MHz, 828.6MHz, 829.4MHz, 830.2MHz, 831MHz)
__| AT| BE| BG| CY| CZ| DE
---|---|---|---|---|---|---
DK| EE| EL| ES| FI| FR
HR| HU| IE| IT| LT| LU
LV| MT| NL| PL| PT| RO
SE| SI| SK| UK(NI)| |

https://www.tonormic.com
  support@tonormic.com

Vous êtes responsable de remettre tous les appareils électriques et électroniques usagés à des points de collecte correspondants.
Pour en savoir plus: www.quefairedemesdechets.fr

FUJIAN EASTWEST LIFEWIT TECHNOLOGY CO.,LTD | RM 1201-1205, BLD 18, 2ND PHASE OF INNOVATION PARK, FUZHOU 350108, CHINA

EASTWEST ELECTRONIC COMMERCE CO US LIMITED | 3500 SOUTH DUPONT HIGHWAY, SUITE G106 DOVER, DE 19901 UNITED STATES

LIFEWIT LIMITED | UNIT 2, VINCENT HOUSE, FIRCROFT WAY, EDENBRIDGE UNITED KINGDOM

Lifewit GmbH | Friedenstraße 5 97072 Wuerzburg Germany MADE IN CHINA

WEEE ID: DE 57064210

FCC Statement

Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help

FCC Radiation Exposure Statement

The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction.

ISED Radiation Exposure Statement

The device has been evaluated to meet general RF exposure requirement. The device can be used installed and operated with minimum distance 0mm between the radiator and your body.
Symbol

TONOR Logo

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

TONOR User Manuals

Related Manuals