MEAN WELL HLG-320H-C700 Constant Current Mode LED Driver Owner’s Manual
- June 13, 2024
- MEAN WELL
Table of Contents
- Features
- Applications
- Description
- Model Encoding
- SPECIFICATION
- BLOCK DIAGRAM
- DRIVING METHODS OF LED MODULE
- DIMMING OPERATION
- DALI Interface (primary side; for DA-Type)
- OUTPUT LOAD vs TEMPERATURE(Note.8)
- STATIC CHARACTERISTIC
- POWER FACTOR (PF) CHARACTERISTIC
- LIFE TIME
- MECHANICAL SPECIFICATION
- INSTALLATION MANUAL
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
MEAN WELL HLG-320H-C700 Constant Current Mode LED Driver Owner’s Manual
Features
- Constant Current mode output
- Metal housing with Class I design
- Built-in active PFC function
- IP67/IP65 design for indoor or outdoor installations
- Function options: output adjustable via potentiometer; 3in 1 dimming
- Typical lifetime>62000 hours
- 7 years warranty
Applications
- LED street lighting
- LED fishing lamp
- LED harbor lighting
- LED building architectural lighting
- LED greenhouse lighting
- LED bay lighting
- Type “HL” foruse in Class I, Division 2 hazardous (Classified) location.
GTIN CODE
MW Search:
htps:/u.meanwel.com/serviceGTiN.aspx
Description
HLG-320H-C series is a 320W LED AC/DC LED driver featuring the constant current mode and high voltage output. HLG-320H-C operates from 90~305VAC and offers models with different rated current ranging between 700mA and 3500mA. Thanks to the high efficiency up to 94%, with the finless design, the entire series is able to operate for -40°C ~ +85°C case temperature under free air convection. The design of metal housing and IP67/IP65 ingress protection level allows this series to fit both indoor and outdoor applications. HLG-320H-C is equipped with various function options, such as dimming methodologies, so as to provide the optimal design flexibility for LED lighting system.
Model Encoding
Type | IP Level | Function | Note |
---|---|---|---|
A | IP65 | Io adjustable through built-in potentiometer. | In Stock |
B | IP67 | 3 in 1 dimming function (0~10Vdc, 10V PWM signal and resistance) | In |
Stock
DA| IP67| DALI control technology.| In Stock
AB| IP65| Io adjustable through built-in potentiometer &3 in 1 dimming
function (0~10Vdc, 10V PWM signal and resistance)| In Stock
Dx| IP67| Built-in Smart timer dimming function by user request.| By request
D2| IP67| Built-in Smart timer dimming and programmable function.| In Stock
SPECIFICATION
MODEL| HLG-320H-C700| HLG-320H-C1050| HLG-320H-C1400|
HLG-320H-C1750| HLG-320H-C2100| HLG-320H-C2800| HLG-
320H-C3500
---|---|---|---|---|---|---|---
OUTPUT| RATED CURRENT| 700mA| 1050mA| 1400mA| 1750mA| 2100mA|
2800mA| 3500mA
RATED POWER| 299.6W| 320.25W| 320.6W| 320.25W| 319.2W| 319.2W|
318.5W
CONSTANT CURRENT REGION Note.2| 214 ~ 428V| 152 ~ 305V| 114
~ 229V| 91 ~ 183V| 76 ~ 152V| 57 ~ 114V| 46 ~ 91V
OPEN CIRCUIT VOLTAGE (max.)| 435V| 311V| 234V| 187V| 156V|
118V| 95V
**CURRENT ADJ. RANGE| Adjustable for A/AB-Type only (via
built-in potentiometer)
350 ~ 700mA| 525 ~ 1050mA| 700 ~ 1400mA| 875 ~ 1750mA| 1050 ~ 2100mA| 1400 ~
2800mA| 1750 ~ 3500mA
CURRENT RIPPLE| 5.0% max. @rated current
CURRENT TOLERANCE| ±5%
SET UP TIME Note.4| 1000ms/115VAC, or 500ms/230VAC
INPUT| VOLTAGE RANGE ****Note.3| 90 ~ 305VAC
127~417VDC(Please refer to “STATIC CHARACTERISTIC” section)
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR (Typ.)| PF≧0.98/115VAC, PF≧0.95/230VAC,
PF≧0.92/277VAC @full load(Please refer to “POWER FACTOR (PF) CHARACTERISTIC”
section)
TOTAL HARMONIC DISTORTION| THD< 20% (@ load≧50% /115VAC, 230VAC;
@ load≧70%/277VAC)(Please refer to “TOTAL HARMONIC DISTORTION (THD)” section)
EFFICIENCY (Typ.)| 94%| 94%| 94%| 94%| 94%| 94%| 94%
AC CURRENT (Typ.)| 3.5A / 115VAC 1.65A / 230VAC 1.45A
/ 277VAC
INRUSH CURRENT(Typ.)| COLD START 70A(twidth=1200μs measured at 50%
Ipeak) at 230VAC; Per NEMA 410
MAX. No. of PSUs on 16A CIRCUIT BREAKER| 2 units (circuit breaker of
type B) / 3 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT| <0.75mA / 277VAC
PROTECTION| SHORT CIRCUIT| Constant current limiting, recovers
automatically after fault condition is removed
OVER VOLTAGE| 436 ~ 460V| 320 ~ 352V| 235 ~ 252V| 192 ~ 211V| 160 ~
175V| 120 ~ 132V| 96 ~ 105V
Shut down and latch off o/p voltage, re-power on to recover
OVER TEMPERATURE| Shut down and latch off o/p voltage, re-power on
to recover
ENVIRONMENT| WORKING TEMP.| Tcase=-40 ~ +85℃(Please refer to
“OUTPUT LOAD vs TEMPERATURE” section)
MAX. CASE TEMP.| Tcase=+85℃
WORKING HUMIDITY| 20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +80℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X,
Y, Z axes
SAFETY & EMC| SAFETY STANDARDS| UL8750(type”HL”), CSA
C22.2 No. 250.13-12; ENEC BS EN/EN61347-1, BS EN/EN61347-2-13, BS EN/EN62384
independent;GB19510.1,GB19510.14,EAC TP TC 004, IP65 or IP67 approved
DALI STANDARDS| Compliance to IEC62386-101,102,(207 by request) for
DA Type only
WITHSTAND VOLTAGE| I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC /
25℃/ 70% RH
EMC EMISSION| Compliance to BS EN/EN55015, BS EN/EN61000-3-2 Class C
(@ load≧50%) ; BS EN/EN61000-3-3,GB17743 andGB17625.1,EAC TP TC 020
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS
EN/EN61547, light industry level (surge immunity Line-Earth 4KV, Line-Line
2KV), EAC TP TC 020
OTHERS| MTBF| 1847.6K hrs min. Telcordia SR-332 (Bellcore) ;
182.3K hrs min. MIL-HDBK-217F (25℃)
DIMENSION| 2529043.8mm (LWH)
PACKING| 1.88Kg; 8pcs/16Kg/0.92CUFT
NOTE**| 1. All parameters NOT specially mentioned are measured at 230VAC
input, rated current and 25℃ of ambient temperature.2. Please refer to
“DRIVING METHODS OF LED MODULE”.3. De-rating may be needed under low input
voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.4.
Length of set up time is measured at first cold start. Turning ON/OFF the
driver may lead to increase of the set up time.5. The driver is considered as
a component that will be operated in combination with final equipment. Since
EMC performance will be affected by the complete installation, the final
equipment manufacturers must re-qualify EMC Directive on the complete
installation again.6. To fulfill requirements of the latest ErP regulation for
lighting fixtures, this LED driver can only be used behind a switch without
permanently connected to the mains.7. This series meets the typical life
expectancy of >62,000 hours of operation when Tcase, particularly tc point (or
TMP, per DLC), is about 75℃ or less.8. Please refer to the warranty statement
on MEAN WELL’s website at
http://www.meanwell.com9. The ambient temperature
derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for
operating altitude higher than 2000m(6500ft).10. For any application note and
IP water proof function installation caution, please refer our user manual
before using.
https://www.meanwell.com/Upload/PDF/LED_EN.pdf※
Product Liability Disclaimer:For detailed information, please refer to
https://[www.meanwell.com/serviceDisclaimer.aspx](http://www.meanwell.com/serviceDisclaimer.aspx)
BLOCK DIAGRAM
Fosc(PFC) : 45KHz
Fosc(PWM) : 70KHz
DRIVING METHODS OF LED MODULE
This series works in constant current mode to directly drive the LEDs.
Typical output current normalized by rated current (%)
DIMMING OPERATION
-
Output constant current level can be adjusted by applying one of the three methodologies between DIM+ and DIM-:
0 ~ 10VDC, or 10V PWM signal or resistance. -
Direct connecting to LEDs is suggested. It is not suitable to be used with additional drivers.
-
Dimming source current from power supply: 100μA (typ.)
Dimming input: Additive voltage
Applying additive 10V PWM signal (frequency range 100Hz ~ 3KHz):
Duty cycle of additive 10V PWM signal dimming input
Applying additive resistance:
(N=driver quantity for synchronized dimming operation)
Dimming input: Additive resistance
Note :
- Min. dimming level is about 6% and the output current is not defined when 0%< Iout<6%.
- The output current could drop down to 0% when dimming input is about 0kΩ or 0Vdc, or 10V PWM signal with 0% duty cycle.
DALI Interface (primary side; for DA-Type)
- Apply DALI signal between DA+ and DA-.
- DALI protocol comprises 16 groups and 64 addresses.
- First step is fixed at 8% of output. Please contact MEAN WELL for other setup.
Smart timer dimming function (for Dxx-Type by User definition)
MEAN WELL Smart timer dimming primarily provides the adaptive proportion dimming profile for the output constant current level to perform up to 14 consecutive hours. 3 dimming profiles hereunder are defined accounting for the most frequently seen applications. If other options may be needed, please contact MEAN WELL for details.
Ex : ◎ D01-Type: the profile recommended for residential lighting
Set up for D01-Type in Smart timer dimming software program:
| T1| T2| T3| T4
---|---|---|---|---
TIME| 06:00| 07:00| 11:00| —
LEVEL| 100%| 70%| 50%| 70%
**: TIME matches Operating Time in the diagram whereas LEVEL matches Dimming
Level.
Example: If a residential lighting application adopts D01-Type, when turning
on the power supply at 6:00pm, for instance:
- The power supply will switch to the constant current level at 100% starting from 6:00pm.
- The power supply will switch to the constant current level at 70% in turn, starting from 0:00am, which is 06:00 after the power supply turns on.
- The power supply will switch to the constant current level at 50% in turn, starting from 1:00am, which is 07:00 after the power supply turns on.
- The power supply will switch to the constant current level at 70% in turn, starting from :00am, which is 11:00 after the power supply turns on.
The constant current level remains till 8:00am, which is 14:00 after the power supply turns on.
Ex: ◎ D02-Type: the profile recommended for street lighting
Set up for D02-Type in Smart timer dimming software program:
| T1| T2| T3| T4| T5
---|---|---|---|---|---
TIME| 01:00| 03:00| 8:00| 11:00| —
LEVEL| 50%| 80%| 100%| 60%| 80%
**: TIME matches Operating Time in the diagram whereas LEVEL matches Dimming Level.
Example: If a street lighting application adopts D02-Type, when turning on the power supply at 5:00pm, for instance:
- The power supply will switch to the constant current level at 50% starting from 5:00pm.
- The power supply will switch to the constant current level at 80% in turn, starting from 6:00pm, which is 01:00 after the power supply turns on.
- The power supply will switch to the constant current level at 100% in turn, starting from 8:00pm, which is 03:00 after the power supply turns on.
- The power supply will switch to the constant current level at 60% in turn, starting from 1:00am, which is 08:00 after the power supply turns on.
- The power supply will switch to the constant current level at 80% in turn, starting from 4:00am, which is 11:00 after the power supply turns on. The constant current level remains till 6:30am, which is 14:00 after the power supply turns on.
Ex: ◎ D03-Type: the profile recommended for tunnel lighting
Set up for D03-Type in Smart timer dimming software program:
| T1| T2| T3
---|---|---|---
TIME| 01:30| 11:00| —
LEVEL| 70%| 100%| 70%
**: TIME matches Operating Time in the diagram whereas LEVEL matches Dimming
Level.
Example: If a tunnel lighting application adopts D03-Type, when turning on the
power supply at 4:30pm, for instance:
- The power supply will switch to the constant current level at 70% starting from 4:30pm.
- The power supply will switch to the constant current level at 100% in turn, starting from 6:00pm, which is 01:30 after the power supply turns on.
- The power supply will switch to the constant current level at 70% in turn, starting from 5:00am, which is 11:00 after the power supply turns on.
The constant current level remains till 6:30am, which is 14:00 after the power supply turns on.
OUTPUT LOAD vs TEMPERATURE(Note.8)
AMBIENT TEMPERATURE, Ta ( )
Tcase ( )
STATIC CHARACTERISTIC
INPUT VOLTAGE (V) 60Hz
POWER FACTOR (PF) CHARACTERISTIC
TOTAL HARMONIC DISTORTION (THD)
EFFICIENCY vs LOAD
HLG-320H-C series possess superior working efficiency that up to 94% can be reached in field applications.
1050mA Model, Tcase at 75℃
LIFE TIME
MECHANICAL SPECIFICATION
A-Type
AB-Type
B/DA/D2-Type
INSTALLATION MANUAL
Please refer to: http://www.meanwell.com/manual.html
Downloaded from Arrow.com
File Name:HLG-320H-C-SPEC 2022-03-16
Read User Manual Online (PDF format)