OPERATING INSTRUCTIONS AND INSTALLATION
Storage tank NAD type
OPERATIONAL MOUNTING REGULATIONS
DESCRIPTION
Storage tanks are used for accumulating of excessive heat received from the
heat source like, for example, a solid fuel boiler, a heat pump, solar
collectors, fireplace inserts, etc. Some tank types allow connecting more than
one heat source at a time.
NAD type storage tanks are used for accumulation of heat in heating systems.
Incorporation of the storage tank into a heating system with a boiler using
solid fuel allows for optimum running of the boiler at a favourable
temperature during boiler operation. The benefit comes mainly during the
optimum running period (i.e. with maximum effectiveness) when the excess heat
that has not been taken off is accumulated in the tank.
Tanks and also possible pipe exchangers are manufactured from steel with no
treatment of the internal surface, the outer surface has a protective coating.
Tanks are equipped with removable 80 mm insulation – NEODUL LB PP. Tanks are
manufactured with volumes of 500, 750 and 1000 litres. Individual versions are
also equipped with one or two 1.4 m² pipe exchangers including inspection
apertures with an inside diameter of 182 mm with the possibility for
installation of in-built TPK electric heating units.
The vessels are not intended for storage of HUW – hot utility water.
4.2 BASIC DIMENSIONS
Volume [l] | Diameter [mm] | Height [mm] |
---|---|---|
500 | 600 | max. 1974 |
750 | 750 | 2022 |
1000 | 850 | 2035 |
4.3 DESCRIPTION OF INDIVIDUAL VERSIONS
NAD v1
Storage tanks can be provided with one to three flanges. The flange with screw
gauge 210 mm can be used for mounting built-in TPK flange electric heating
units. The flange is blocked off in the standard version. The G 6/4″ extension
pipe cab be used for mounting of the TJ G 6/4″ electric heating unit. Supplied
with insulation with a thickness of 80 mm.
NAD v2
Storage tank can be provided with G 6/4″ extension pipe. The G 6/4″ extension
pipe cab be used for mounting of the TJ G 6/4″ electric heating unit. Supplied
with insulation with a thickness of 80 mm.
NAD v3
Storage tank with a flange with screw gauge 210 mm and extension pipes or only
with extension pipes. The flange with a screw gauge of 210 mm can be used for
mounting built-in TPK flange heating units. The flange is blocked off in the
standard version. Supplied with insulation with a thickness of 80 mm.
NAD v4
Storage tank with a flange with screw gauge 210 mm for mounting built-in TPK
flange heating units and one 1.4 m² exchanger for further heating system
connection (e.g. SOLAR). The flange is blocked off in the standard version.
Supplied with insulation with a thickness of 80 mm.
4.4 ILLUSTRATION OF NAD VERSIONS
Outlets:
1. Inlets for water to storage tank
3. Outlet for storage tank (air outlet)
4. Other outlet
5. Water inlet to storage tank (discharge)
6. Wells for sensors (thermometer, thermostat)
7. Water outlet from storage tank (return water)
8. Flange with screw gauge 210 for TPK mounting
11. Possibility for mounting TJ 6/4″ el. heating unit| internal G 5/4″
external G 1″
internal G 5/4″
external G 1″
internal G 1/2″
internal G 5/4″| 1. Inlets for water to storage tank 3. Outlet for storage
tank (air outlet)
5. Water inlet to storage tank (discharge)
6. Wells for sensors (thermometer, thermostat)
7. Water outlet from storage tank (return water)
11. Possibility for mounting TJ 6/4″ el. heating unit| internal G 5/4″
external G 1″
external G 1″
internal G 1/2′
internal G 5/4′
---|---|---|---
Outlets:
1. Outlets (inlets) for water to storage tank, possibility of mounting TJ
6/4″ el. heating unit
3. Outlet for storage tank (air outlet) external G 1″
6. Wells for sensors (thermometer, thermostat) internal G 1/2″
8. Flange with screw gauge 210 for TPK mounting
Outlets:
1. Inlets for water to storage tank 3. Outlet for storage tank (air outlet)
4. Other outlet 5. Water inlet to storage tank (discharge) 6. Wells for
sensors (thermometer, thermostat) 7. Water outlet from storage tank (return
water) 8. Flange with screw gauge 210 for TPK mounting separate heating system
– sol. Heat pump 9. Inlet for heating water 10. Outlet for heating water 11.
Possibility for mounting TJ 6/4″ el. heating unit| internal G 5/4″ external G
1″ internal G 5/4″ external G 1″ internal G 1/2″ internal G 5/4″
external G1″ external G1″
---|---
4.5 PROPOSAL FOR SIZE AND CONNECTION OF THE STORAGE TANK TO A HEATING
SYSTEM
Proposal for the optimum size of the storage tank is made by the designer or a
person with sufficient knowledge for design of heating systems.
Mounting is carried out by a specialist company or person who can confirm
mounting in on the guarantee certificate.
4.6 BASIC TECHNICAL PARAMETERS
Maximum operational pressure in the tank is 0,3 MPa. Maximum temperature of
heating water in the tank is 90 °C.
For versions 4 and 5 also:
Maximum operational pressure in the exchanger is 1 MPa, maximum temperature of
heating water in the exchanger is 110 °C.
We recommend you use the product indoors with an air temperature of +2 °C to
+45 °C and relative humidity of max. 80 %.
No stop fitting can be put between the security fitting of the heating circuit
and the accumulation tank!!!
The appliance has to be mounted at a convenient place, it means that the
appliance must be easily available for potential necessary maintenance, repair
or replacement, as the case may be.
Heat insulation
80 mm thick insulation NEODUL LB PP. The top cover covers of flanges and hole
caps are integral components. Insulation is supplied in separate packing.
We recommend you use insulation for operation at room temperature. At
temperatures markedly lower than 20 °C the insulation shrinks and cannot be
fitted.
Product Fiche
| NAD 500 v1| NAD 500 v2| NAD 500 v3| NAD 500 v4
---|---|---|---|---
The standing loss (W)| 83| 83| 83| 80
| 475| 475| 475| 475
The standing loss (W)| 122| 122| 122| 119
| 772| 772| 772| 772
The standing loss (W)| 135| 135| 135| 133
| 999| 999| 999| 999