Supply

Features

  • AC input range selectable by switch
  • Withstand 300VAC surge input for 5 second
  • Up to 200% peak power capability
  • Protections: Short circuit/Overload / Over voltage/ Over temperature
  • Forced air cooling by built-in DC fan
  • Built-in cooling Fan ON-OFF control
  • Compliance to IEC/BS EN/EN61558-1 and 62368-1
  • Withstand 5G vibration test
  • LED indicator for power on
  • No load power consumption<1W
  • Over voltage category III(OVC III)
  • High operating temperature up to 70°C
  • Operating altitude up to 2000 meters
  • High efficiency, long life and high reliability
  • 3 years warranty

Applications

  • Industrial automation machinery
  • Industrial control system
  • Mechanical and electrical equipment
  • Electronic instruments, equipments or apparatus For inductive and capacitive load

GTIN CODE

MW Search: hitps://wiw.meanvell.com/serviceGTIN.aspx

Description

LRS-350N2 series is a 350W single-output enclosed type power supply with 30mm of low profile design. Adopting the input of 115VAC or 230VAC (select by switch), the entire series provides an output voltage line of 12V, 24V, 36V and 48V. In addition to the high efficiency up to 89%, with the built-in long life fan LRS-350N2 can work under -25~+70°C with full load. Delivering an extremely low no load power consumption (less than 0.75W), it allows the end system to easily meet the worldwide energy requirement. LRS-350N2 has the complete protection functions and 5G anti-vibration capability; it is complied with the international safety regulations such as IEC/UL 62368-1. LRS-350N2 series serves as a high price-to-performance power supply solution for various industrial applications. Moreover, LRS-350N2 can provide 200% short-duration peak power for motor applications and electro mechanical loads requiring much higher power during start-up.

Model Encoding

Model Encoding

SPECIFICATION

MODEL| LRS-350N2-12| LRS-350N2-24| LRS-350N2-36| IRS- 350N2-48
---|---|---|---|---
OUTPUT| DC VOLTAGE| 12V| 24V| 36V| 48V
RATED CURRENT| 29A| 14.6A| 9.7A| 7.3A
CURRENT RANGE| 0 – 29A| 0 – 14.6A| 0 – 9.7A| 0 – 7.3A
RATED POWER| 348W| 350.4W| 349.2W| 350.4W
RIPPLE &NOISE (max.) Note/| 150mVp-p| 150mVp-p| 200mVp-p| 200mVp-p
VOLTAGE ADJ. RANGE| 10.2 – 13.8V| 21.6 – 28.8V| 32.4 – 39.6V| 432- 52.8V
VOLTAGE TOLERANCE| ±1.5%| ±1.0%| ±1.0%| ±1.0%
LINE REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION| ± 1.0%| ±0.5%| ±0.5%| ±0.5%
SETUP. RISE TIME| 1300ms. 50ms/230VAC               1300ms.50ms/115VAC at MI load
HOLD UP TIME (Typ.)| 16ms230VAC     12ms/115VAC al fili load
INPUT| VOLTAGE RANGE| 90- 132VAC / 180 – 264VAC by switch       240 – 370VDC (switch on 230VACI
FREQUENCY RANGE| 47 – 63Hz
EFFICIENCY (Typ.)| 85%                               188% 188.5%                                           189%
AC CURRENT (Typ.)| 6.8N115VAC                  3.8A/230VAC
INRUSH CURRENT (Typ.)| 60UV115VAC                60N230VAC
LEAKAGE CURRENT| <2mA/ 240VAC
PROTECTION| OVER LOAD| Output power >105% rated for more than 5 seconds then shot down ofp voltage. re-power on to recover
Output power >200% rated. hiccup mode. recovers automatically after fautt condition is removed
OVER VOLTAGE| 13.8 – 16.2’V                                     128.8 – 33.6V 141.4 – 46.8V                                     1552 -64.8V
Shut down and lalch off *village. re-power on to recover.
OVER TEMPERATURE| Shut down and latch off ofp voltage. re-power on to recover.
FUNCTION| FAN ON/OFF CONTROL (Typ.)| RTH3a50t FAN ON. 540’C FAN OFF
DVENIDIf| WORKING TEMP.| -25 – •70″C (Refer to ‘Berating Curve’)
WORKING HUMIDITY| 20 – 90% FtH non-ccodensing
STORAGE TEMP.. HUMIDITY| -40- +85C . 10 – 95% RH
TEMP. COEFFICIENT| ± o.onrc go – 50°C)
VIBRATION| 10 – 500Hz. 5G 10min./1cycle. 60min. each along X. Y.2 axes
OVER VOLTAGE CATEGORY| III:According to 801558. EN50178. EN60664-1. EN62477-1: altitude up to 2000 meters
SAFETY| SAFETY STANDARDS| IECAJL 62368-1. BSIAI CN514336-1.EAC TP TC 034.84S 1313252(Part1): 2010’IEC 60950-1:2005:BS ENIEN61558-1, BS EN61558-2-16 Designed by BS/ENIEN52368-1.ASNTS 61558.112.16. ASACS 62368.1
WITHSTAND VOLTAGE| UP-01P:3.75KVAC              UP-FG:2KVAC             OfP- FG:0.5KVAC
ISOLATION RESISTANCE| I/P-OrP. UP-FG, OR-PG:100M Ohms/500VDC / 25’C/ 70% RH
EMC EMISSION| Compliance to BSMI CNS13438. EAC TP TC 020
EMC IMMUNITY| Compliance to BS ENIEN55035. EAC TP TC 020
OTHERS| MTBF| 1857.9K ha min.               Telcordia SR-332 (Bellcore) : 226.2Khrs min.             MIL-HDBK-217F (25 CI
DIMENSION| 215’115’30mm (LIMN)

NOTE

  1. Al parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.

  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

  3. Length of set up time s measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.

  4. This power supply does not meet the harmonic current requirements outlined by BS EN/EN61000-3-2. Please do not use this power supply under the following conditions:
    a) the end-devices is used within the European Union, and
    b) the end-devices is connected to public mains supply with 220Vac or greater rated nominal votiage, and the power supply is:

    • installed in end-devices with average or continuous input power greater than 75W, or
    • belong to part of a lighting system
      Exception:
      Power supplies used within the following end-devices do not need to full BS EN/EN61000-3-2
      a) professional equipment with a total rated input power greater than 1000W;
      b) symmetrically controlled heating elements with a rated power less than or equal to 200W
  5. RCM is on voluntary basis and meets relevant IEC or ASINZS standards complying with ASNZS 4417.1
    Product Liability Disclaimer : For detailed information, please refer to hitps:/www.meanwell.comiserviceDisclaimer.aspx

Block Diagram

Block Diagram

Derating Curve

AMBIENT TEMPERATURE (℃)
Derating Curve

Static Characteristics

INPUT VOLTAGE (VAC) 60Hz
Static Characteristics

Function Manual

  1. Peak Power

P av : Average output power(W)
P pk : Peak output power(W)
P npk : Non-peak output power(W)
P rated : Rated output power(W) Peak power width(sec) Period(sec)
Function Manual

Input Voltage (VAC)
Function Manual

Peak Power / Rated Power
Function Manual

For example (24 model)
Vin=220VAC, Duty_max=10% Pav=Prated=350W Ppk=700W t≤5sec T≥ 5sec 10% =50sec Pnpk≤ TPav-tPpk T-t =311W

Mechanical Specification

Mechanical Specification

Terminal Pin No. Assignment:

Pin No. Assignment
1 AC/L
2 AC/N
3 FG
4~6 DC OUTPUT -V
7~9 DC OUTPUT +V

Installation Manual