LNC A04988P3 3-Light Chandelier Instruction Manual

June 13, 2024
LNC

LNC A04988P3 3-Light Chandelier

LNC A04988P3 3-Light Chandelier

Introduction

WARNING (To reduce the risk of fire, electric shock, or personal injury):

  1. We suggest installation by a licensed electrician.

  2. Please read the instruction carefully and save it as you may need it at a later time.

  3. Before you start, NEVER attempt any work without shutting off the electricity until the work is done.
    » Go to the main fuse, or circuit breaker, box in your home.
    Place the main power switch in the “OFF” position.
    » Place the wall switch in the “OFF” position.

  4. Mounting surface should be clean, dry, flat, strong enough and 1/4” larger than the canopy on all sides. Any gaps between the mounting surface and canopy exceeding 3/16” should be corrected as required.

  5. Make sure that the ceiling or wall can stand the weight of the lamp before installation.

  6. Make sure the voltage you are using is 120V. The maximum wattage is Type B, Max 40W per bulb.

  7. Keep the lamp away from acidic and alkaline substances in case of damaging the surface of the lamp.

  8. When replacing bulbs, you should turn off or unplug the lamp and you must wait until it is cool as bulbs get hot quickly.

  9. The safety instructions appearing in this manual are not meant to cover all possible conditions that may occur. It must be understood that common sense, caution and care must be used with any electrical products.

IMAGE FOR FINISHED PRODUCT

TOOLS REQUIRED (NOT INCLUDED)

Before starting assembly and installation please prepare the needed tools as below picture.

| | | |
---|---|---|---|---

Ladder

| Philips Head or Flat
Blade Screwdriver| Electrical Tape| Pliers|

Wire Cutter/Stripper

PARTS TYPE & QTY INCLUDING

(C) Mounting plate (1)
(D) Green ground screw (1)
(E) Canopy (1)
(F) Strain relief (6)
(G) Hex nut (1)
(H) Cap nut (1)
(I) Cord (3)
(J) Iron frame (3)
(K) Nut (9)
(L) Glass shade (3)
ACCESSORIES & QTY ENCLOSED
(A) Plastic Wire Connector (3)
(B) Mounting screw (2)
(M) Allen wrench (1)
(K) Nut (1) (spare part)
Parts Type & Qty Including

ASSEMBLY & INSTALLATION INSTRUCTIONS

  1. Carefully remove the fixture from the carton and check that all parts and accessories are included as shown in the above illustration.

  2. Turn off power
    Before you start the installation, NEVER attempt any work without shutting off the electricity until the work is done
    .

    • Go to the main fuse, or circuit breaker, box in your home.
      Place the main power switch in the “OFF” position.

    • Place the wall switch in the “OFF” position.

  3. » Unscrew hex nut (G) and cap nut (H) from mounting plate (C) as shown in the illustration.

  4. » Adjust the length of cords (I) to achieve the desired height of the mounted fixture.

  5. Use Allen wrench (M) to unscrew the screw in strain reliefs (F), carefully pull and push cords (I) through canopy (E) and strain reliefs (F) to lengthen or shorten the length of cords (I).

  6. Once the desired height of fixture is achieved, carefully tighten the screw till snug.

  7. » If needed, shorten the extra length of the fixture wires from cords (I) so that they all are at least 6 inches (152.4 mm) long above canopy (E) within the outlet box.

  8. » Carefully pass supply wires through mounting plate (C).
    Secure mounting plate (C) to the outlet box with mounting screws (B).
    Assembly & Installation Instructions

  9. » Make wire connections
    Connect wires as below wires connection shown. REFER TO THE FOLLOWING CHARTS, NEVER CONNECT OTHER WIRES TO GROUND WIRES.
    Connect Ground Wires According To The Below Chart

Connect Black or Red Supply Wire to: Connect White Supply Wire to:
Black White
*Parallel cord (round & smooth) *Parallel cord (square & ridged)
Clear, Brown, Gold or Black without tracer Clear, Brown, Gold or Black with

tracer
Insulated wire(other than green) with copper conductor| Insulated wire(other than green) with silver conductor

  • Note : When parallel wires (SPT I& SPT ll) are used. The neutral wire is square shaped or ridged and the other wire will be round in shape or smooth (see illus.)
    Connect Ground Wires According To The Below Chart
    Twist wires together with plastic wire connectors (A) until tightly joined, and wrap each connector with approved electrical tape for a more secure connection, then carefully tuck all wires into the outlet box.

    1. Fix canopy (E) to mounting plate (C) and secure with the previously removed hex nut (G) and ball nut (H).
      Assembly & Installation Instructions
      NOTE : The canopy (E) should be snug against the ceiling and cap nut (H).
      If not, adjust the threaded length of the preassembled threaded nipple on mounting plate(C):
      • Unscrew the pre-assembled hex nut.
      Screw the pre-assembled threaded nipple in or out of mounting plate(C).
      • When the secure length is achieved, tighten the pre-assembled hex nut and
      • back to step 8.

    2. » 1) Unscrew nuts (K) from iron frames (J).

  1. Align holes of glass shades (L) with holes of iron frames (J).
  2. Screw nuts (K) into holes to secure glass shades (L) and iron frames (J) as shown in the illustration.
  3. Install bulbs (not included) (Please do not exceed the maximum wattage recommended on the socket.)
    Assembly & Installation Instructions
  1. Check everything is already installed properly, then you could turn on the light. Enjoy!

ORDERING PARTS

Keep this sheet for future reference in case you need to order replacement parts. All parts for this fixture can be ordered from the place of purchase. Be sure to use exact wording from illustration when ordering parts.

CLEANING

To clean, wipe the fixture with a soft cloth. Clean glass with a mild cleaner (such as mild and non-abrasive soap). Do not use abrasive materials such as scouring pads or powders, steel wool or abrasive paper.