WARNING
WARNING (To reduce the risk of fire, electric shock, or personal injury):
-
We suggest installation by a licensed electrician.
-
Please read the instruction carefully and save it as you may need it at a later time.
-
Before you start, NEVER attempt any work without shutting off the electricity until the work is done.
» Go to the main fuse, or circuit breaker, box in your home.
Place the main power switch in the “OFF” position.
» Place the wall switch in the “OFF” position. -
Mounting surface should be clean, dry, flat, strong enough and 1/4” larger than the canopy on all sides. Any gaps between the mounting surface and canopy exceeding 3/16” should be corrected as required.
-
Make sure that the ceiling or wall can stand the weight of the lamp before installation.
-
Make sure the voltage you are using is 120V. The maximum wattage is Type B, Max 40W per bulb.
-
Keep the lamp away from acidic and alkaline substances in case of damaging the surface of the lamp.
-
When replacing bulbs, you should turn off or unplug the lamp and you must wait until it is cool as bulbs get hot quickly.
-
The safety instructions appearing in this manual are not meant to cover all possible conditions that may occur. It must be understood that common sense, caution and care must be used with any electrical products.
IMAGE FOR FINISHED PRODUCT:
TOOLS REQUIRED (NOT INCLUDED):
Before starting assembly and installation please prepare the needed tools as below picture
| | | |
---|---|---|---|---
Ladder| Philips Head or Flat Blade Screwdriver| Electrical Tape| Pliers| Wire
Cutter/Stripper
PARTS INCLUDING:
( C ) Green ground screw (1)
( D ) Mounting plate (1)
( E ) Back plate (1)
( F ) Knob nut (2)
( G ) Pipe (4)
( H ) Arm (4)
( I ) Nut (12)
( J ) Iron frame (4)
( K ) Glass shade (4)
ACCESSORIES ENCLOSED:
( A ) Mounting screw (2)
( B ) Plastic wire connector (3)
Make assembly
» Go to the main fuse, or circuit breaker, box in your home.
Place the main power switch in the “OFF” position.
» Place the wall switch in the “OFF” position.
(I) Nut (1) (spare part)
ASSEMBLY & INSTALLATION INSTRUCTIONS:
- Carefully remove the fixture from the carton and check that all parts and accessories are included as shown in the above illustration.
- Turn off power
Before you start the installation, NEVER attempt any work without shutting off the electricity until the work is done.
» Go to the main fuse, or circuit breaker, box in your home.
Place the main power switch in the “OFF” position.
» Place the wall switch in the “OFF” position.
Make assembly
| |
---|---|---
|
Step A1 »
Step A2 »
Step A3 »
Unscrew knob nuts (F) from back plate (E), then set them aside for later
installation.
Carefully pass the supply wires from the outlet box through mounting plate
(D).
Secure mounting plate (D) to the outlet box with mounting screws (A).
Make wire connections
Connect wires as below wires connection shown. PLEASE NOTE THAT GROUND WIRE IS
BARE
COPPER WIRE, NEVER CONNECT OTHER WIRES TO GROUND WIRES
Connect ground wires according to the below chart
Connect wir s according to the below chart
Connect Black or Red Supply Wire to: | Connect White Supply Wire to |
---|---|
Black | White |
*Parallel cord (round & smooth) | *Parallel cord (square & ridged) |
Clear, Brown, Gold or Black without tracer | Clear, Brown, Gold or Black with |
tracer
Insulated wire(other than green) with copper conductor| Insulated wire(other
than green) with silver conductor
Note: When parallel wires (SPT I& SPT ll) are used. The neutral wire is square
shaped or ridged and the other wire will be round in shape or smooth (see
illus.)|
Twist wires together with plastic wire connectors until tightly joined, and wrap each connector with approved electrical tape. Be sure that no wire strands are exposed and then carefully tuck all wires into the outlet box.
Step A4 » Align the holes in back plate (E) with the pre-assembled mounting screws, then attach back plate (E) to mounting plate (D) with the previously removed knob nuts (F). Hand tighten until snug.
NOTE: back plate (E) should be snug against the wall with knob nuts (F).
If not, remove back plate (E), adjust the threaded length of pre-assembled
mounting screws on mounting plate (D):
- Unscrew the pre-assembled hex nuts.
- Screw the pre-assembled mounting screws in or out of mounting plate (D).
- When the secure length is achieved, tighten the pre-assembled hex nuts and back to Step A4
Step A5 » 1) Screw pipes (G) to top of arms (H) as shown in the illustration.
2) Unscrew nuts (I) from iron frames (J).
3) Align holes of glass shades (K) with holes of iron frames (J).
4) Screw nuts (I) into holes to secure glass shades (K) and iron frames (J) as
shown in the
illustration.
5) Install bulbs (not included) (Please do not exceed the maximum wattage
recommended on the
socket.)
Check everything is installed properly, then you could turn on the light. Enjoy!
ORDERING PARTS
Keep this sheet for future reference in case you need to order replacement parts. All parts for this fixture can be ordered from the place of purchase. Be sure to use exact wording from illustration when ordering parts.
CLEANING
To clean, wipe the fixture with a soft cloth. Clean glass with a mild cleaner
(such as mild and non-abrasive soap). Do not use abrasive materials such as
scouring pads or powders, steel wool or abrasive paper.
Customer Service
+1 850 296 2377 Working hours : Mon – Fri 9:00 – 16:00 EST