LNC A04976P3 Idaikos 3-Light Polished Gold and White Shaded Modern-Contemporary LED Dry Rated Chandelier Instruction Manual

June 13, 2024
LNC

LNC A04976P3 Idaikos 3-Light Polished Gold and White Shaded Modern-

Contemporary LED Dry Rated Chandelier

LNC-A04976P3-Idaikos 3-Light Polished Gold and White Shaded Modern-
Contemporary-LED Dry Rated Chandelier-product

Product Information

  • Item Number: A04976P3
  • Maximum Wattage: Type B, Max 40W per bulb
  • Voltage: 120V

Product Usage Instructions

  1. Before starting assembly and installation, make sure to prepare the following tools (not included):

Tools Required

Ladder
Philips Head or Flat Blade Screwdriver
Electrical Tape
Pliers
Wire Cutter/Stripper

  1. Assembly & Installation Instructions:

1. Carefully remove the fixture from the carton and check that all parts and accessories are included as shown in the above illustration.

2. Before starting the installation, turn off the power. NEVER attempt any work without shutting off the electricity until the work is done.

3. Adjusting the height of the mounted fixture:

  • Use Allen wrench (M) to unscrew the screws in strain reliefs (F).
  • Carefully pull and push cords (I) through canopy (E) and strain reliefs (F) to lengthen or shorten the length of cords (I).
  • Once the desired height of the fixture is achieved, carefully tighten the screws till snug.
  • Make sure the remaining wire length measured above canopy (E) is at least 6 inches.

4. Mounting the fixture:

  • Ensure that the mounting surface is clean, dry, flat, strong enough, and 1/4 larger than the canopy on all sides.
  • If there are any gaps between the mounting surface and canopy exceeding 3/16, correct them as required.
  • Make sure that the ceiling or wall can stand the weight of the lamp before installation.

5. Connecting the wires:

  • Connect ground wires according to the provided chart.
  • Connect black or red supply wire to the corresponding outlet box ground.
  • Connect white supply wire to the corresponding outlet box ground.
  • Never connect other wires to ground wires.

Contact Information

Customer Care: +1 850 296 2377 (Working hours: Mon – Fri 9:00 – 16:00 EST)

Email: homecustomercare@outlook.com

Item Number: A04976P3
WARNING (To reduce the risk of fire, electric shock, or personal injury):

  1. We suggest installation by a licensed electrician.

  2. Please read the instruction carefully and save it as you may need it at a later time.

  3. Before you start, NEVER attempt any work without shutting off the electricity until the work is done.
    » Go to the main fuse, or circuit breaker, box in your home.
    Place the main power switch in the “OFF” position.
    » Place the wall switch in the “OFF” position.

  4. Mounting surface should be clean, dry, flat, strong enough and 1/4” larger than the canopy on all sides. Any gaps between the mounting surface and canopy exceeding 3/16” should be corrected as required.

  5. Make sure that the ceiling or wall can stand the weight of the lamp before installation.

  6. Make sure the voltage you are using is 120V. The maximum wattage is Type B, Max 40W per bulb.

  7. Keep the lamp away from acidic and alkaline substances in case of damaging the surface of the lamp.

  8. When replacing bulbs, you should turn off or unplug the lamp and you must wait until it is cool as bulbs get hot quickly.

  9. The safety instructions appearing in this manual are not meant to cover all possible conditions that may occur. It must be understood that common sense, caution and care must be used with any electrical products.

IMAGE FOR FINISHED PRODUCT:

TOOLS REQUIRED (NOT INCLUDED)

Before starting assembly and installation please prepare the needed tools as below picture

LNC-A04976P3-Idaikos 3-Light Polished Gold and White Shaded Modern-
Contemporary-LED Dry Rated Chandelier-fig-2

PARTS TYPE & QTY INCLUDING

  • (C) Single bar (1)
  • (D) Green ground screw (1)
  • (E) Canopy (1)
  • (F) Strain relief (6)
  • (G) Nex nut (1)
  • (H) Cap nut (1)
  • (I) Cord (3)
  • (J) Socket (3)
  • (K) Iron shade (3)
  • (L) Socket ring (3)

LNC-A04976P3-Idaikos 3-Light Polished Gold and White Shaded Modern-
Contemporary-LED Dry Rated Chandelier-fig-3

ACCESSORIES & QTY ENCLOSED

  • (A) Plastic Wire Connector (3)
  • (B) Mounting screw (2)
  • (M) Allen wrench (1)

ASSEMBLY & INSTALLATION INSTRUCTIONS

  1. Carefully remove the fixture from the carton and check that all parts and accessories are included as shown in the above illustration.

  2. Turn off power
    Before you start the installation, NEVER attempt any work without shutting off the electricity until the work is done.

    • Go to the main fuse, or circuit breaker, box in your home. Place the main power switch in the “OFF” position.
    • Place the wall switch in the “OFF” position.
  3. Unscrew hex nut (G) and cap nut (H) from single bar (C).

  4. Adjust the length of cords (I) to achieve the desired height of the mounted fixture.

  5. Use Allen wrench (M) to unscrew the screws in strain reliefs (F), carefully pull and push cords (I) through canopy (E) and strain reliefs (F) to lengthen or shorten the length of cords (I).

  6. Once the desired height of fixture is achieved, carefully tighten the screws till snug.

  7. If needed, shorten the length of fixture wires. At this point, the remaining wire length measured above canopy (E) is at least 6″.

  8. Secure single bar (C) to the outlet box with mounting screws (B).
    NOTE: the side of single bar (C) marked “GND” must face out.

LNC-A04976P3-Idaikos 3-Light Polished Gold and White Shaded Modern-
Contemporary-LED Dry Rated Chandelier-fig-5

  1. Make wire connections
    Connect wires as below wires connection shown. REFER TO THE FOLLOWING CHARTS, NEVER CONNECT OTHER WIRES TO GROUND WIRES.

LNC-A04976P3-Idaikos 3-Light Polished Gold and White Shaded Modern-
Contemporary-LED Dry Rated Chandelier-fig-6

  * Twist wires together with plastic wire connector (A) until tightly joined.
  * Wrap each connector with approved electrical tape for a more secure connection,
  * Carefully tuck all wires into the outlet box.
  1. Raise canopy (E) to the ceiling and secure canopy (E) in place by tightening hex nut (G) and cap nut (H) onto the pre -assembled threaded nipple on single bar (C).

  2. Unscrew socket rings (L) from sockets (J).
    Carefully place iron shades (K) on sockets (J), then secure iron shades (K) with socket rings (L).
    Install bulbs (Not included) (Please do not exceed the maximum wattage recommended on the socket.)

  3. Check everything is already installed properly, then you could turn on the light. Enjoy!

ORDERING PARTS

Keep this sheet for future reference in case you need to order replacement parts. All parts for this fixture can be ordered from the place of purchase. Be sure to use exact wording from illustration when ordering parts.

CLEANING

To clean, wipe the fixture with a soft cloth. Do not use abrasive materials such as scouring pads or powders, steel wool or abrasive paper.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

LNC User Manuals

Related Manuals