CAS PR-II Price Computing Scale User Manual

June 13, 2024
CAS

CAS PR-II Price Computing Scale

Product Information

Thank you for purchasing CAS PR series. These series have been designed with CAS reliability, under rigid quality control and with outstanding performance. Your special departments can enjoy these high-quality reliable CAS products. We believe that your needs will be satisfied, and you will have proper reliability. This manual will help you with proper operation and care of the PR. Please keep it handy for future reference.

Key Functions

Keys Functions
~ Used to enter all the numeric data
PLU key Used to enter PLU setting
Price Clear key Used to clear all the numeric price display
Total Clear key Used to clear sum total price
Daily Clear key Used to clear all the daily total prices
Zero Correction key Used to correct the zero point
Tare key To set or clear tare value
PLU Save key To make several sales transactions by adding up
Total Sales key To check total sales amount or finalize sales transaction
Decimal Point key Used to enter the decimal point when the price is entered
Backlight Setting key Used to change backlight setting (OFF, ON, AUTO)
Power Save Mode key Used to enter price per 100g ($/100g)

Product Usage Instructions

Chapter 1. Basic Operation

a. Zero function: Press the ZERO key to set Zero.

b. Tare function: Tare means the weight of the container. You may use the tare function when you weigh an item with a container and measure only the weight of the item.

One-time tare:

  1. Place a container on the platter (e.g., 200g of tare).

  2. Press the TARE key to set the zero point (e.g., 200g of tare).
    Successive tare:

  3. Place another container on the platter (e.g., 100g of tare).

  4. Press the TARE key to set the zero point.

  5. After weighing the item, remove all of the containers from the platter.

  6. Press the TARE key again to set zero.

NOTICE: To remove the TARE function, press the TARE Key again after removing the container from the platter.
Automatic tare clearing function may not be applied to all of the PR series.

Chapter 2. PLU Saving & Calling-up

a. Saving unit price on PLU: This section explains how to save unit price in PLU.

PLU NAME Number of PLU Range Remarks

Press the ‘Fn’ key for a few seconds then, Set-up menu will be
shown.| 7| 1~7|

b. Calling up PLU: After inputting the unit price, press the number of PLU that you want to set up.

Press M1 ~ M7 key to call up PLU (e.g., Press M1 key).

Press C key to clear and return to the normal weighing mode.

Chapter 3. User’s Set-up Mode

This section explains how to set up the following functions:

KEY Display FUNCTION
bL-At Use back-light when you put on the weight
bL-oFF Do not use a back-light
bL-on Use back-light always
ps – 0 Do not use power save mode Use power save mode
up- kg Used to price per kg
up-100g Used to price per 100g ($/100g)
rS-Co Continually mode
rS-PC
rS-St Command mode Stable mode

PRECAUTIONS

Warning
Precautions when installing the scale. To ensure that you get the most from your scale, please follow these instruction.

  • Do not disassemble the scale.
    When any damage or defect occurs, contact your CAS authorized dealer immediately for proper repair.

  • Do not overload beyond the maximum weight limit.

  • Scale must be grounded to minimize electricity static.
    This will minimize defect or electric shock.

  • Do not pull the plug by its cord when unplugging.
    Damaged cord could cause electric shock or fire.

  • To prevent from fire occurring, Do not place or use the scale near flammable or corrosive gas.

  • To reduce electric shock or incorrect reading,Do not spill water on the scale or place it in humid condition.

  • Avoid placing the scale near heater or in direct sunlight.

  • Insert plug firmly to wall outlet to prevent electric shock.

  • Use proper Adapter.
    Incorrect adapter could damage the scale.

  • Attention
    Make sure to plug your scal into the proper power outlet.
    For maximum performance, plug into a power outlet 30 minutes before the usage for warm up.

Attention
Make sure to plug your scal into the proper power outlet.
For maximum performance, plug into a power outlet 30 minutes before the usage for warm up.

  • For consistent and accurate reading, maintain perlodical check by your CAS authorized dealer.

  • Avold sudden shock to the scale.

  • Grab on the bottom of the scale when moving.

  • Keep the scale away from other electromagnetic enerating devices.
    This may interfere with accurate reading.

  • Place the scale on firm and temperature consistent environment.

  • By adjusting 4 comers of the scale, set the scale even using the built in scale leveling indicator.

  • Take the battery out when scale is not in use for long time. Leakage from the batteries is hazardous.

PREFACE
Thank you for purchasing CAS PRII series.
These series have been designed with CAS reliability, under rigid quality control and with outstanding performance. Your special departments can enjoy these high quality reliable CAS products.
We believe that your needs will be satisfied and you will have proper reliability.
This manual will help you with proper operation and care of the PRII.
Please keep it handy for future reference.

OVERALL VIEW

CAS-PR-II-Price-Computing-Scale-FIG- \(1\)

DISPLAY & KEY BOARD

PR II – B Front display

PR II – B Rear display

CAS-PR-II-Price-Computing-Scale-FIG- \(3\)

PR II – P Front cover & key

CAS-PR-II-Price-Computing-Scale-FIG- \(4\)

KEY FUNCTIONS

CAS-PR-II-Price-Computing-Scale-FIG- \(5\)

COLUMN INSTALLATION

CAS-PR-II-Price-Computing-Scale-FIG- \(6\)

OPERATIONS

Turn on the ON/OFF switch. Then, the display will show all the segments and count up “9” to “O”.

Basic Operation

CAS-PR-II-Price-Computing-Scale-FIG- \(7\)

  • Zero function
    1. Press ZERO key to set Zero.
  • Tare function
    Tare means the weight of container. You may use tare function when you weigh an item with container and measure only the weight of item.

One time tare

CAS-PR-II-Price-Computing-Scale-FIG- \(8\)

CAS-PR-II-Price-Computing-Scale-FIG- \(9\)

  1. Place a container on the platter.
    EX) 200g of tare.

  2. Press TARE key to set zero point.
    EX) 200g of tare.
    Successive tare

  3. Place another container on the platter.
    EX) 100g of tare.

  4. Press TARE key to set zero point.

  5. After weighing item remove all of the container from the platter.

  6. Press TARE key again to set zero.

NOTICE: To remove TARE funtion press “TARE” Key again after removing the container from the paltter. Automatic tare clearing function may not be applied to all of PR series.

PLU Saving & Calling-up

Saving unit price on PLU
This section explains how to save unit price in PLU.

  Number of PLU Range Remarks
PLU NAME 7 1~7

CAS-PR-II-Price-Computing-Scale-FIG- \(10\)

  1. Press the ‘Fn’ key for a few seconds then, Set-up menu will be shown.
  2. After input unit of price, press number of  PLU that you want to set up.

Calling up PLU

CAS-PR-II-Price-Computing-Scale-FIG- \(11\)

  1. Press M1 ~ M7 key to call up PLU. e,g,Press M1 key.
  2. Press C key to clear and return to the normal weighing mode.
User’s Set-up Mode

This section explains how to set up the following functions.

CAS-PR-II-Price-Computing-Scale-FIG- \(12\)

Sales transaction

PR-Ⅱ can provide inputting the unit price through the numeric key and calling up PLU.

Input the unit price through the numeric key
This section explains how to input the unit price through the numeric key and complete the sales transaction.

CAS-PR-II-Price-Computing-Scale-FIG- \(13\)

  1. Place an item on the platter and press appropriate numeric keys to input unit price.
    EX) 1.99 for unit price.

  2. Remove the item from the platter.

Input the unit price through calling up PLU

CAS-PR-II-Price-Computing-Scale-FIG- \(14\)

  1. Press M1~M7 key can call up the PLU. EX) M1
  2. Place an item on the platter.
  3. Remove an item on the platter.

Adding up several sales transactions for weighed items

Use + key to makes the adding-up transactions.

You may either call up PLU or just input the unit price.

CAS-PR-II-Price-Computing-Scale-FIG- \(15\)

CAS-PR-II-Price-Computing-Scale-FIG- \(16\)

  1. Press M1~M7 key can call up the PLU. EX) M1

  2. Place an item on the platter.

  3. Press + key.

  4. Remove the item from the platter.

  5. Input a unit price.
    EX) 2.99 for Honey melon

  6. Place an item on the platter.

  7. Press + key. “Total Price” display says total price added, and “Unit Price” display says the number of sales transactions added.

  8. Remove the item from the platter.

CAS-PR-II-Price-Computing-Scale-FIG- \(17\)

You may also place the item on the platter first and then input unit price in the scale later.

Payment

Payment function on total sales amount

CAS-PR-II-Price-Computing-Scale-FIG- \(18\)CAS-PR-
II-Price-Computing-Scale-FIG- \(19\)

  1. Press Σ key to call up total price.
    (If you want to go back to sales mode, press zero key.)

  2. Input payment of consumer by numeric key.
    Ex) 120.00 payment

  3. Press Σ key to call up the change amount.

  4. After checking the change amount press Σ key to go back to normal weighing mode.

Deleting total sales data

CAS-PR-II-Price-Computing-Scale-FIG- \(20\)

  1. Press Σ key to call up total price.
    (If you want to go back to sales mode, press zero key.)

  2. Press C key to delete “② total sales” data.
    Clear account message shows up shortly, and then it goes to normal weighing mode.

  3. And then it goes to normal weighing mode.

Interface in Detail

This function is helpful to understand RS-232C Communication user setting.
The following is the communication information of RS-232C.

RS-232C Port Connection

CAS-PR-II-Price-Computing-Scale-FIG- \(21\)

  • 8-BIT ASCII code
  • None parity
  • 1 stop bit
  • baud rate 9600

USB INTERFACE(Device)

RS-232C Protocol

CAS-PR-II-Price-Computing-Scale-FIG- \(23\)

Transmission Data description

DATA Value(HEX) Description
SOH 01h Start of heading
STX 02h Start of text
STA S(53h),U(55h) S: Stable , U:Unstable
SIGN -(2Dh),SP(20h) Sign of the weight data
W5~W0   Weight data
UN1,UN2 KG,LB Unit of Weight
BCC   Block check character exclusive or(^)
ETX 03h End of text
EOT 04h End of transmission

COMMAND : DC2(0X12) SCALE - > PC DATA FORMAT

CAS-PR-II-Price-Computing-Scale-FIG- \(24\)

All Data Format (total price,weight,unit price)

MAINTENANCE

LOW BATTERY WARNING

  • This product is a combination product dry battery and rechargeable battery.
  • When the battery is low the display shows the ” bAt-Lo ” sign.
  • You can replace the battery new one.
  • If rechargeable battery, please charge immediately.
  • You can shorten battery life.
  • If you still use the scale without replacing the battery the scale may provide incorrect result on measurement.

ERROR MESSAGE

CAS-PR-II-Price-Computing-Scale-FIG- \(25\)

SPECIFICATIONS

MODEL : PRII

CAS-PR-II-Price-Computing-Scale-FIG-26

Notice: Specifications are subject to change for improvement without notice.

CAS BLDG., #1315, YANGJAE-DAERO,GANGDONG-GU, SEOUL, KOREA
TEL 82 2 2225 3500
FAX
82 2 475 4668
www.globalcas.com
9002-PRE-0033-0 2016.03

Specifications are subject to change for improvement without prior notice.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

CAS User Manuals

Related Manuals