CAS PR-II PR-II Price Computing Scale User Manual

June 12, 2024
CAS

PR-II PR-II Price Computing Scale
User ManualCAS PR-II PR-II Price Computing Scale

PR-II PR-II Price Computing Scale

With this scale you have acquired a modern, highly technical measuring instrument. CAS scales are designed and manufactured under strict quality control to guarantee you the best performance, reliability and durability. This manual will help you to get the maximum benefit from your CAS scale. Please read it carefully before use and keep it handy during subsequent use to find quick solutions to problems.

NOTES ON COMMISSIONING AND INSTALLATION

Make sure you use the correct mains voltage. To obtain optimum performance, switch on the scale 30 minutes before starting work to warm it up.

Do not disassemble the scale! When any damage or defect occurs, contact  your CAS authorized dealer immediately for proper repair.CAS PR-II PR-II Price
Computing Scale - assemble 1Do not overload beyond the maximum weight limit. Scale must be grounded to minimize electricity static. This will minimize defect or electric shock. CAS PR-II PR-II Price
Computing Scale - assemble 3Do not pull by its cord when unplugging. Damaged cord could cause electric shock or fire.

To prevent from fire occurring, do not place or use the scale near flammable or corrosive gas.CAS PR-II PR-II Price Computing Scale - assemble
5To reduce electric shock or incorrect reading, do not spill water on the scale or place it in human condition. CAS PR-II
PR-II Price Computing Scale - assemble 6Avoid placing the scale near heater or in direct sunlight. CAS PR-II PR-II Price Computing Scale - assemble 7Insert plug firmly to wall outlet to prevent electric shock. Use proper adapter. Incorrect adapter could damage the scale. CAS PR-II PR-
II Price Computing Scale - assemble 9For consistent and accurate reading maintain periodical check by your CAS authorized dealer. CAS PR-II PR-II Price Computing Scale -
assemble 10Avoid sudden shock to the scale.
Grab on the bottom of the scale when moving.  Always remove the batteries from the scale if it is not going to be used for a long time. This prevents damage due to possible leakage. CAS PR-II PR-II Price Computing Scale - assemble
13Place the scale on firm and temperature consistent environment. By adjusting 4 corners of the scale, set the scale even using the built in scale levelling indicator. CAS PR-II PR-II Price
Computing Scale - assemble 15Keep the scale away from other electromagnetic enerating devices. This may interfere with accurate reading. Only use batteries approved by CAS! There is a risk of explosion with incorrect batteries or rechargeable batteries. CAS PR-II PR-II Price
Computing Scale - assemble 17 ■ Column installation (Typ PR-II P) CAS PR-II PR-II Price Computing Scale -
assemble 18

  1. Slide the rod into the holder.
  2. Screw the two fastening screws into the bracket. Make sure, that the cable is not pinched.

OVERVIEW

CAS PR-II PR-II Price Computing Scale - assemble 19

DISPLAY AND KEY BOARD

■ PR-II B – Front display CAS PR-II PR-II Price Computing Scale - DISPLAY
1 ■ PR-II B – Rear display
CAS PR-II PR-II Price Computing Scale - DISPLAY 2■ PR-II P – Displaycover CAS PR-II PR-II Price Computing Scale - DISPLAY
3 ■ KEY FUNCTIONS

KEYS FUNCTIONS

CAS PR-II PR-II Price Computing Scale - icon 1| Used to enter all the numeric data
| PLU key
| Function key (Back-light, Power Save)
Used to enter PLU setting
| Used to clear all the numeric price display
| Used to correct the zero point
| To set or clear tare value
| Double zero key
CAS PR-II PR-II Price Computing Scale - icon 8| Used to change back-light setting.(OFF, ON, AUTO)
| Power Save Mode

BASIC OPERATIONS

■ Turn on

  • Turn on the [ON/OFF] switch (below the scale) Then, the display will show all the segments and count up „9 “ to „0 “.
  • Once the weight is stable, the „ “ is displayed.

■ Zero tracking (manual)
During operation, deviations in the zero position may occur due to various influences such as temperature fluctuations or similar. By pressing the key, the current load is adopted as the zero position.
■ Simple weighing

  1. Place the goods on the platform. The weight is displayed at the top left.
    CAS PR-II PR-II Price Computing Scale - Simple weighing
1

  2. Remove the goods from the platform.CAS PR-II PR-II Price Computing Scale - Simple weighing 2

■ Tare function
Tare means the weight of container. You may use tare function when you weigh an item with container and measure only the weight of item.

  1. Place a container on the platter. EX) 200g of tare.
    CAS PR-II PR-II Price Computing Scale - Simple weighing
3

  2. Press Tare key to set zero point.CAS PR-II PR-II Price Computing Scale - Simple weighing 4 • Successive tare

  3. Place another container on the platter. EX: 100g of tare.
    CAS PR-II PR-II Price Computing Scale - Simple weighing
5

  4. Press TARE key to set zero point.CAS PR-II PR-II Price Computing Scale - Simple weighing 6

  5. After weighing item remove all of the container from the platter. EX: 300g Tara
    CAS PR-II PR-II Price Computing Scale - Simple weighing
7

  6. Press TARE key again to set zero.
    CAS PR-II PR-II Price Computing Scale - Simple weighing
8

NOTICE: To remove TARE funtion press “TARE” Key again after removing the container from the paltter.
Automatic tare clearing function may not be applied to all of PR series..
■ PLU Saving & Calling-up
This section explains how to save unit price in PLU.
• Saving unit price on PLU

  1. Use the number keys to enter the desired price per kilo.EX) 199€CAS PR-II PR-II Price Computing Scale - Simple weighing 9

  2. Now press and hold the PLU button you want to save for 5 seconds. A beep confirms that the key has been saved.EX) M1CAS PR-II PR-II Price Computing Scale - Simple weighing 9 • PLU call up

  3. Press the respective PLU key , until to call up the item. EX) M1 The deposited price is displayed at the top right.
    CAS PR-II PR-II Price Computing Scale - Simple weighing
11

  4. Press key to clear PLU mode and return to the normal weighing mode.
    CAS PR-II PR-II Price Computing Scale - Simple weighing
12

■ User’s Set-up Mode

KEY Display FUCTION

CAS PR-II PR-II Price Computing Scale - icon 8| bL-oFF| Do not use a back-light
bL- on| Use back-light always
| ps-0| Do not use power save mode
ps-1| Use power save mode
| rS-Co| Continually mode
rS-PC| Command mode
rS-St| Stable mode

  • RS232-Optional interface

■ Sales transaction
• Input the unit price through the numeric key

  1. Place an item on the platter and press appropriate numeric keys to input unit price. EX) 199 for unit price.
    CAS PR-II PR-II Price Computing Scale - Simple weighing
13

  2. Remove the item from the platter.
    CAS PR-II PR-II Price Computing Scale - Simple weighing
14

  3. Press key to clear and return to the normal weighing mode.CAS PR-II PR-II Price Computing Scale - Simple weighing 15Note: You can also place the item on the weighing platform first and enter the unit price on the scale in the second step.
    • Input the unit price through calling up PLU

  4. Press key can call up the PLU. EX) M1
    CAS PR-II PR-II Price Computing Scale - Simple weighing
16

  5. Place an item on the platter.
    CAS PR-II PR-II Price Computing Scale - Simple weighing
17

  6. Remove an item from the platter.
    CAS PR-II PR-II Price Computing Scale - Simple weighing
18

  7. Press key to clear PLU mode and return to the normal weighing mode.
    CAS PR-II PR-II Price Computing Scale - Simple weighing
19

Note: You can also place the item on the weighing platform first and enter the desired PLU key on the scale in the second step.

BATTERY MAINTANCE

■ Low battery warning

  • This product is a combination product dry battery and rechargeable battery.
  • When the battery is low the display shows the „bAt-Lo„ sign. You need to replace the battery with a new one. If you use a rechargeable battery, please charge it immediately, otherwise you can shorten the life of the battery. If you still use the scale without replacing the battery the scale may provide incorrect result on measurement.
  • If the display shows „Err b“, the battery must be changed or charged, otherwise incorrect weighing results may be delivered.

ERROR MASSAGE

Display Description Solution
Z-Err The „Z-Err“ occurs when a current zero point has
shifted from the last span calibration. Please call your CAS dealer.
Err 3 The Err 3 („oL“) is an overload error. Please remove the weight.
Err b The Err b („bAt-Lo“) is battery low Please change new battery. If

rechargeable battery, please charge immediately.

SPECIFICATIONS

PR-II

Capacity| 3 / 6 kg| 6 / 15 kg| 15 / 30 kg
Interval (e)| 1 / 2 g| 2 / 5 g| 5 / 10 g
External Resolution| Jan-00| Jan-00| Jan-00
MAX Tare| -2,999 kg| -5,998 kg| -14,995 kg
Display| 6/6/6 (Weight / Unit price/ Total price); 54 × 19 mm
Symbols| ZERO, TARE, kg/lb,100g/1oz, ADD, SUM, Low Battery, AC POWER
Keys| ZERO, TARE, M1~M7 KEY, FUCTION, ADD, SUM
Platter size| 330 (W) x 235 (D)[mm] / 129.92 (W) x 92.52 (D)[inch]
Dimensions| B TYPE : 341 (W) x 383 (D) x 102 (H)[mm] / 134 (W) x 151 (D) x 40 (H)[inch] P TYPE : 341 (W) x 435 (D) x 474 (H)[mm] / 134 (W) x 171 (D) x 186 (H)[inch]
Weight| Typ B: 2,8 kg / Typ P: 3,2 kg
Power| 1.5 V x 3 units (D size Battery), Pb 4V/4Ah, 6 V Adapter
Operation Time| Approx. 300 hours (Manganese Battery) / 600 hours  (Alkaline at 20 °C / 68 °F) / Backlight off
Operating Temperature| -10 °C ~ +40 °C / 14 °F ~ 104 °F
Option| RS232, USB, Manganese Battery, Pole Type

Specifications are subject to change or improvement without prior notice.
Your CAS dealer
DC-71111202
CAS DEUTSCHLAND AG
Brackestraße 1 ∙ 38159 Vechelde ∙ Germany

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals