CAS IE-1700 Digital Crane Scale User Manual
- June 13, 2024
- CAS
Table of Contents
INDUSTRIAL WEIGHING SOLUTION™ User Manual
SAFETY GUIDE
Read carefully the following instruction and advice before using this scale.
■ Over-loading this scale is harshly prohibited
■ Refrain from long-time loading that could lead to excessive fatigue on
loadcell used inside the scale. Excessive fatigue that on loadcell would
decrease the accuracy and shorten the life of scale.
■ Check the shackle and hook regularly.
■ Check the battery power level before/after use and recharge the scale in
time.
■ In order to maximize the battery life, periodic recharging is necessary for
scales even not in use for long time.
■ Do not try to repair the scale by yourselves.
■ Use privately attached charger only.
PRECAUTION
■ The crane scale is a kind of precise weighing instrument, pay attention on
operantion and maintenance.
■ Rotate the load instead of machine otself if necessary for operation.
■ Stop using the machine under the circumstances of thunder & rain.
■ Check periodicly if the clips/pins and screws of the machine are loose or
broken before use.
■ If low battery signal appeare & LED annunciator goes green while charging,
please check the battery.
■ Hang the machine instrad for storage while not in use in order to prevent
from unnecessary load in the weight sensor inside.
■ Do not subject the scale to sudden to sudden temperature changes.
■ Avoid from the shock of excessive weight.
PRODUCT CHARACTERISTICS
Model | Display | characteristics |
---|---|---|
IE Series | 30mm(1.2″)LED | High accuracy, small volume, easy to bring |
30mm(1.2″)LCD
■ High quality: The process management is operated according to OIML R76,
GB/T11883-2002, and get the European CE certificate.
■ Safty installation: Aluminum Die-Casting Case, high intensity hook and
shackle, special loadcell for safty installation.
■ High reliability: Using high quality components on PCB circul board to board
to insure long time stability.
■ Broad applicability: 30mm high character display, 25M distance eyeshot, can
be used in storage industry, textile industry, metallurgy industry etc.
■ Simple operation: Check battry voltage automatically, wireless remote
controller, separate battery space, small volume, easy to bring.
■ Complete function: Kg/Lb conversion, Hold, Tare, Division choice, Stablity
regulation, Accumulation/Search, Gross/Net conversion, parameter regulation
etc.
SPECIFICATION
Standard | GB/T11883-2002《Electrical Crane Scale》 |
---|---|
Accuracy class | OIML class III |
Display | 30mm(1.2″) 5digits LCD/LED |
Zero Range | 4% full capacity |
Tare Range | 100% Full capacity |
Stable Time | ≤10 seconds |
Overload Indication | 100% Max. capacity + 9e |
Max. Safety Load | 125% Max. capacity |
Ultimate Load | 400% Max. capacity |
Battery Life | ≥50 hours |
Battery Type | Fully sealed Lead-Acid battery, 6V/5Ah |
Adapter | DC9V/1500mA |
Operating Temp. | – 10℃ ~ + 40℃ |
Operating Humidity | ≤85% RH under 20℃ |
--- | --- |
Remote Controller Distance | Min. 10m |
Battery of Remote Controller | 5# battery, 1.5Vⅹ2 |
MODEL
**Model| Max. capacity (kg / lb)| Min. capacity
(kg / lb)| Division (kg / lb)| Total
display (kg / lb)
---|---|---|---|---
IE-100| 50/100| 0.5/1| 0.02/0.05| n=2000**
IE-200| 100/200| 1/2| 0.05/0.1| n=2000
IE-500| 200/500| 2/4| 0.1/0.2| n=2500
IE-1000| 500/1000| 4/10| 0.2/0.5| n=2000
IE-2000| 1000/2000| 10/20| 0.5/1| n=2000
SIZE AND NET WEIGHT
**Max.Capacity| L (mm)| A (mm)| B (mm)|
C (mm)| Net weight**
---|---|---|---|---|---
100kg| 335| 20| 65| 20| 4.0
200kg| 335| 20| 65| 20| 4.0
300kg| 335| 20| 65| 20| 4.0
500kg| 360| 25| 75| 20| 4.2
1000kg| 360| 25| 75| 20| 4.2
OPERATION
■ TURN ON
Operation | Display | Illustration |
---|---|---|
【OFF/ON】 | 【 8.8.8.8.8 】 | Display two times |
【 500.0 】 | Display capacity two times | |
【 U X.XX 】 | Display the voltage of battery | |
【 – – – – – 】 | Wait stable signal | |
【 0】 | “STB” light, can hang the weight |
※ Notice: To guarantee the accuracy, leave scale alone for 3~5 minutes after
turning on.
■ ZERO
Operation | Display | Illustration |
---|---|---|
Press【→0←】on scale | 【 0】 | After turn on, generally display【 0】, if not for 【 |
Can operate like this0】
Press 【 ZERO 】 on controller| 【 0】
■ TARE
Operation | Display | Illustration |
---|---|---|
Press【→T←】on scale | 【 0】 | Press this key to deduct the weight of |
Container, while “TARE” light on, the Scale will show the net weight of load
Press 【 TARE 】 on controller| 【 0】
※ Notice: As crane scale deduct the weight of container automatically, so it
will show the net weight of load every time, you needn’t press this key to get
net weight until you change the container or turn off.
※ OVERLOAD WARNING
The display will show【-OL-】once the load (Net + Tare) exceeds Max. capacity.
Make sure that the load are within the capacity range, otherwise it’s very
dangerous.
■ CHECK BATTERY
Press【OFF/ON】on scale,whenturnonorturnoff,itshows【U X.XX】
Press 【OFF】oncontroller2seconds
Stableafter15minute,itshow【
】,after60minutes,itturnoffautomatically.
■ HOLD THE WEIGHT READING
Press “HOLD” key on the remote controller to hold the displayed weight
reading.
At this moment, “HOLD” light on, Press this key again will disable hold
function.
■ LOW BATTERY WARNING
When the battery voltage lower then【U 5.8.0】, the display flash, but the scale
can still work until the display show 【 -Lb- 】, one minute later, it will turn
off automatically, you need to recharge the battery to use again.
■ POWER SAVING
The display will show 【 ━ 】when the load are at stable status in excess of 15
minutes and revert to normal weighing readings while load changes. When the
load are at stable status in excess of 60 minutes, the scale will turn off
automatically
■ RECHARGING BATTERY
- Turn off, connect the adapter with 220V AC power supply, also insert the plug in the socket which located in the rear of scale. The light become green, it means it’s recharging automatically, until the green light become red, that means recharging is finished.
- When you need to use crane scale hour after hour, take off the rear cover, change the battery with recharged battery.
Attention : Generally, the time of recharging should not lower than 8
hours, this scale have recharging protection function, long time recharging
will not damage the battery.
■ TURN OFF
Press【OFF/ON】on scale 2 seconds
Press【OFF】on controller 2 seconds
Stable after 15minutes, it show【 】, after 60minutes, it turn off
automatically.
ELECTRICAL PRINCIPLE DIAGRAM
DISPLAY MESSAGE
Display | Illustration |
---|---|
【 – – – – -】 | Waiting stable |
【 Err10】 | Accumulated weight not exceed Min. Capacity |
【 Err11】 | Accumulated times exceed, (can’t accumulate after 30times) |
【 Err12】 | Accumulated weight exceed (can’t accumulate after 99999) |
【 CLr】 | Ask if you really want to delete accumulated weight, in case error |
deletion
【 noCLr】| Give up deletion
【 88888】| Confirm deletion
【 noACC】| No any accumulated value (when you check)
【 SHIFt】| Conversion, when you press SHIFT in controller
【 UX.XX】| The voltage of current battery
【 SCALE】| Enter weight adjustment
【 SEtUP】| Enter parameter adjustment
【 UAdJ 】| Enter voltage adjustment
【 -OL- 】| Overload warning
【 -Lb- 】| Low battery warning
【 End 】| End, when parameter adjustment ready
【 OFF 】| Turn off
TROUBLESHOOTING
Phenomenon | Reason | Solution |
---|---|---|
No display when Turn on | Battery damaged | Check battery |
Battery contact loosed | Tighten the contact | |
Display flash | Low battery Min.Capacity | Recharge the battery |
Can’t trun on & off | 【OFF/ON】Abuttun damaged | Check & clean the buttun |
Can’t tare | 【TARE】Abuttun damaged | Check & clean the buttun |
**** Recharge indicator Light can’t turn on | The recharger damaged | Check the |
recharger
The recharger isn’t plugged ready| Insert plug again
Display isn’t stable| The load is unstable| Stablize the load
Loadcell cable damaged| Check and replace loadcell
The scale in damp Environment for a long time| Put the scale in dry
Environment
The display don’t show “0” when empty load| No enough time for
heatingthe scale after turn on| After turning on, heating3-5 minutes.
Put the scale on ground for too long time| Scale should be hung
The error is large| The scale isn’t hung properly| Check the scale and sling
**** Battery can’t recharge| Battery damaged| Replace battery
Outlet damaged| Replace the outlet
Remote distance shorten| Receiver window is too dirty| Check and clean
Low battery of controller| Replace controller battery
REMOTE CONTROLLER GUIDE
■ Lightness of display
Operation | Illustration |
---|---|
【F1】 | 0~5, 0: no display, 1: Minimum light, 5: Maximum light (Default: 2) |
■ ZERO
Operation | Illustration |
---|---|
【ZERO】 | display〖 0〗 when no load, “ZERO” light on |
■ HOLD
Operation | Illustration |
---|---|
【HOLD】 | Hold the weight, “HOLD” light on |
【HOLD】 | Convert to weighing situation, “HOLD” light off |
■ TARE
- Tare directly
Operation| Illustration
---|---
【TARE】| Display show net weight, “TARE” light on
【TARE】| Display show gross weight, “TARE” light off - Set tare weight in advance
Operation| display| Illustration
---|---|---
【 MR 】| 【SHIFT】|
【TARE】| 【00000】| Current tare weight
| 【 *】| Input the tare weight
【 MR 】| 【 – 】| Exit, “TARE” light on, it will deduct tare weight automatically when weighing.
■ ACCUMULATION
Operation | display | Illustration |
---|---|---|
【 M+ 】 | 【No **** 】 | Current accumulation times |
【H 】 | Rear four digit of current accumulated value | |
【L 】 | Front four digit of current accumulated value |
Attention: After display two times circlely, it will return to weigh
situation automatically, you also can press MR to return directly.
■ SEARCH
Operation | display | Illustration |
---|---|---|
【 MR 】 | 【No **** 】 | Current accumulation times |
【 M+ 】 | 【 *】 | Current weight |
【H 】 | Rear four digit of current accumulated value | |
【L 】 | Front four digit of current accumulated value | |
【 MR 】 | 【 0】 | Return to weigh |
Attention: Press【TAR E 】and 【→0←】can search every time weight and
accumulated value, press 【 MR 】return.
■ CLEAR
Operation | display | Illustration |
---|---|---|
【CLEAR】 | 【 CLr 】 | Display blink, please confirm if you want to delete |
Accumulated value
【CLEAR】| 【noCLr】| Cancel deletion
【 MR 】| 【88888】| Confirm deletion
■ ZERO DISPLAY
Operation | display | Illustration |
---|---|---|
【 MR 】 | 【SHIFT】 | |
【→0←】 | 【 **** 】 | Display current zero value |
■ KG/LB CONVERSION
Operation | display | Illustration |
---|---|---|
【 MR 】 | 【SHIFT】 | Un = 0 : kg “lb” light off |
Un = 1 : kg “lb” light on,
【CLEAR】| 【Un= *】
■ SEARCH OVERLOAD TIMES
Operation | display | Illustration |
---|---|---|
【 MR 】 | 【SHIFT】 | |
【CLEAR】 | 【OL= ***** 】 | Display times of overload |
■ VOLTAGE DISPLAY
Operation | display | Illustration |
---|---|---|
【 MR 】 | 【SHIFT】 | |
【 F1 】 | 【U X.XX】 | Display show current voltage of the battery |
【 MR 】 | 【 0】 | Return to weigh |
■ TURN OFF
Operation | display | Illustration |
---|---|---|
【OFF】 | 【 OFF 】 | |
【U X.XX】 | Display show current voltage of battery then turn off |
CAS BLDG., # 440-1, SUNGNAE-DONG,
GANGDONG-GU, SEOUL, KOREA
TEL 82 2 2225 3500 FAX 82 2 475 4668
www.gtobalcas.com
Specifications are subject to change for improvement without prior notice.
9002-1E0-0033-0 2008.06
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>