CAS IE-1700 Digital Crane Scale User Manual

June 13, 2024
CAS

INDUSTRIAL WEIGHING SOLUTION™ User Manual

SAFETY GUIDE

Read carefully the following instruction and advice before using this scale.
■ Over-loading this scale is harshly prohibited
■ Refrain from long-time loading that could lead to excessive fatigue on loadcell used inside the scale. Excessive fatigue that on loadcell would decrease the accuracy and shorten the life of scale.
■ Check the shackle and hook regularly.
■ Check the battery power level before/after use and recharge the scale in time.
■ In order to maximize the battery life, periodic recharging is necessary for scales even not in use for long time.
■ Do not try to repair the scale by yourselves.
■ Use privately attached charger only.

PRECAUTION

■ The crane scale is a kind of precise weighing instrument, pay attention on operantion and maintenance.
■ Rotate the load instead of machine otself if necessary for operation.
■ Stop using the machine under the circumstances of thunder & rain.
■ Check periodicly if the clips/pins and screws of the machine are loose or broken before use.
■ If low battery signal appeare & LED annunciator goes green while charging, please check the battery.
■ Hang the machine instrad for storage while not in use in order to prevent from unnecessary load in the weight sensor inside.
■ Do not subject the scale to sudden to sudden temperature changes.
■ Avoid from the shock of excessive weight.

PRODUCT CHARACTERISTICS

Model Display characteristics
IE Series 30mm(1.2″)LED High accuracy, small volume, easy to bring

30mm(1.2″)LCD

■ High quality: The process management is operated according to OIML R76, GB/T11883-2002, and get the European CE certificate.
■ Safty installation: Aluminum Die-Casting Case, high intensity hook and shackle, special loadcell for safty installation.
■ High reliability: Using high quality components on PCB circul board to board to insure long time stability.
■ Broad applicability: 30mm high character display, 25M distance eyeshot, can be used in storage industry, textile industry, metallurgy industry etc.
■ Simple operation: Check battry voltage automatically, wireless remote controller, separate battery space, small volume, easy to bring.
■ Complete function: Kg/Lb conversion, Hold, Tare, Division choice, Stablity regulation, Accumulation/Search, Gross/Net conversion, parameter regulation etc.

SPECIFICATION

Standard GB/T11883-2002《Electrical Crane Scale》
Accuracy class OIML class III
Display 30mm(1.2″) 5digits LCD/LED
Zero Range 4% full capacity
Tare Range 100% Full capacity
Stable Time ≤10 seconds
Overload Indication 100% Max. capacity + 9e
Max. Safety Load 125% Max. capacity
Ultimate Load 400% Max. capacity
Battery Life ≥50 hours
Battery Type Fully sealed Lead-Acid battery, 6V/5Ah
Adapter DC9V/1500mA
Operating Temp. – 10℃ ~ + 40℃
Operating Humidity ≤85% RH under 20℃
--- ---
Remote Controller Distance Min. 10m
Battery of Remote Controller 5# battery, 1.5Vⅹ2

MODEL

**Model| Max. capacity (kg / lb)| Min. capacity (kg / lb)| Division (kg / lb)| Total display (kg / lb)
---|---|---|---|---
IE-100| 50/100| 0.5/1| 0.02/0.05| n=2000**
IE-200| 100/200| 1/2| 0.05/0.1| n=2000
IE-500| 200/500| 2/4| 0.1/0.2| n=2500
IE-1000| 500/1000| 4/10| 0.2/0.5| n=2000
IE-2000| 1000/2000| 10/20| 0.5/1| n=2000

SIZE AND NET WEIGHT

CAS IE 1700 Digital Crane Scale - WEIGHT

**Max.Capacity| L (mm)| A (mm)| B (mm)| C (mm)| Net weight**
---|---|---|---|---|---
100kg| 335| 20| 65| 20| 4.0
200kg| 335| 20| 65| 20| 4.0
300kg| 335| 20| 65| 20| 4.0
500kg| 360| 25| 75| 20| 4.2
1000kg| 360| 25| 75| 20| 4.2

OPERATION

■ TURN ON

Operation Display Illustration
【OFF/ON】 【 8.8.8.8.8 】 Display two times
【      500.0 】 Display capacity two times
【 U X.XX 】 Display the voltage of battery
【 – – – – – 】 Wait stable signal
【             0】 “STB” light, can hang the weight

※ Notice: To guarantee the accuracy, leave scale alone for 3~5 minutes after turning on.
■ ZERO

Operation Display Illustration
Press【→0←】on scale 【 0】 After turn on, generally display【 0】, if not for 【

Can operate like this0】


Press 【 ZERO 】 on controller| 【 0】

■ TARE

Operation Display Illustration
Press【→T←】on scale 【           0】 Press this key to deduct the weight of

Container, while “TARE” light on, the Scale will show the net weight of load
Press 【 TARE 】 on controller| 【           0】

※ Notice: As crane scale deduct the weight of container automatically, so it will show the net weight of load every time, you needn’t press this key to get net weight until you change the container or turn off.
※ OVERLOAD WARNING
The display will show【-OL-】once the load (Net + Tare) exceeds Max. capacity.
Make sure that the load are within the capacity range, otherwise it’s very dangerous.
■ CHECK BATTERY

Press【OFF/ON】on scale,whenturnonorturnoff,itshows【U   X.XX】

Press 【OFF】oncontroller2seconds
Stableafter15minute,itshow【 】,after60minutes,itturnoffautomatically.

■ HOLD THE WEIGHT READING
Press “HOLD” key on the remote controller to hold the displayed weight reading.
At this moment, “HOLD” light on, Press this key again will disable hold function.
■ LOW BATTERY WARNING
When the battery voltage lower then【U 5.8.0】, the display flash, but the scale can still work until the display show 【 -Lb- 】, one minute later, it will turn off automatically, you need to recharge the battery to use again.
■ POWER SAVING
The display will show 【 ━ 】when the load are at stable status in excess of 15 minutes and revert to normal weighing readings while load changes. When the load are at stable status in excess of 60 minutes, the scale will turn off automatically
■ RECHARGING BATTERY

  1. Turn off, connect the adapter with 220V AC power supply, also insert the plug in the socket which located in the rear of scale. The light become green, it means it’s recharging automatically, until the green light become red, that means recharging is finished.
  2. When you need to use crane scale hour after hour, take off the rear cover, change the battery with recharged battery.

Attention : Generally, the time of recharging should not lower than 8 hours, this scale have recharging protection function, long time recharging will not damage the battery.
■ TURN OFF

Press【OFF/ON】on scale 2 seconds

Press【OFF】on controller 2 seconds
Stable after 15minutes, it show【      】, after 60minutes, it turn off automatically.

ELECTRICAL PRINCIPLE DIAGRAM

CAS IE 1700 Digital Crane Scale - PRINCIPLE DIAGRAM

DISPLAY MESSAGE

Display Illustration
【 – – – – -】 Waiting stable
【 Err10】 Accumulated weight not exceed Min. Capacity
【 Err11】 Accumulated times exceed, (can’t accumulate after 30times)
【 Err12】 Accumulated weight exceed (can’t accumulate after 99999)
【 CLr】 Ask if you really want to delete accumulated weight, in case error

deletion
【 noCLr】| Give up deletion
【 88888】| Confirm deletion
【 noACC】| No any accumulated value (when you check)
【 SHIFt】| Conversion, when you press SHIFT in controller
【 UX.XX】| The voltage of current battery
【 SCALE】| Enter weight adjustment
【 SEtUP】| Enter parameter adjustment
【 UAdJ 】| Enter voltage adjustment
【 -OL- 】| Overload warning
【 -Lb- 】| Low battery warning
【 End 】| End, when parameter adjustment ready
【 OFF 】| Turn off

TROUBLESHOOTING

Phenomenon Reason Solution
No display when Turn on Battery damaged Check battery
Battery contact loosed Tighten the contact
Display flash Low battery Min.Capacity Recharge the battery
Can’t trun on & off 【OFF/ON】Abuttun damaged Check & clean the buttun
Can’t tare 【TARE】Abuttun damaged Check & clean the buttun
**** Recharge indicator Light can’t turn on The recharger damaged Check the

recharger
The recharger isn’t plugged ready| Insert plug again
Display isn’t stable| The load is unstable| Stablize the load
Loadcell cable damaged| Check and replace loadcell
The scale in damp Environment for a long time| Put the scale in dry Environment
The display don’t show “0” when empty load| No enough time for heatingthe scale after turn on| After turning on, heating3-5 minutes.
Put the scale on ground for too long time| Scale should be hung
The error is large| The scale isn’t hung properly| Check the scale and sling
**** Battery can’t recharge| Battery damaged| Replace battery
Outlet damaged| Replace the outlet
Remote distance shorten| Receiver window is too dirty| Check and clean
Low battery of controller| Replace controller battery

REMOTE CONTROLLER GUIDE

■ Lightness of display

Operation Illustration
【F1】 0~5, 0: no display, 1: Minimum light, 5: Maximum light (Default: 2)

■ ZERO

Operation Illustration
【ZERO】 display〖    0〗 when no load, “ZERO” light on

■ HOLD

Operation Illustration
【HOLD】 Hold the weight, “HOLD” light on
【HOLD】 Convert to weighing situation, “HOLD” light off

■ TARE

  1. Tare directly
    Operation| Illustration
    ---|---
    【TARE】| Display show net weight, “TARE” light on
    【TARE】| Display show gross weight, “TARE” light off
  2. Set tare weight in advance
    Operation| display| Illustration
    ---|---|---
    【 MR 】| 【SHIFT】|
    【TARE】| 【00000】| Current tare weight
    | 【 *】| Input the tare weight
    【 MR 】| 【 –
    】| Exit, “TARE” light on, it will deduct tare weight automatically when weighing.

■ ACCUMULATION

Operation display Illustration
【 M+ 】 【No **** Current accumulation times
【H Rear four digit of current accumulated value
【L Front four digit of current accumulated value

Attention: After display two times circlely, it will return to weigh situation automatically, you also can press MR to return directly.
■ SEARCH

Operation display Illustration
【 MR 】 【No **** Current accumulation times
【 M+ 】 *】 Current weight
【H Rear four digit of current accumulated value
【L Front four digit of current accumulated value
【 MR 】 【 0】 Return to weigh

Attention: Press【TAR E 】and 【→0←】can search every time weight and accumulated value, press 【 MR 】return.
■ CLEAR

Operation display Illustration
【CLEAR】 【 CLr 】 Display blink, please confirm if you want to delete

Accumulated value
【CLEAR】| 【noCLr】| Cancel deletion
【 MR 】| 【88888】| Confirm deletion

■ ZERO DISPLAY

Operation display Illustration
【 MR 】 【SHIFT】
【→0←】 【 **** Display current zero value

■ KG/LB CONVERSION

Operation display Illustration
【 MR 】 【SHIFT】 Un = 0 : kg “lb” light off

Un = 1 : kg “lb” light on,
【CLEAR】| 【Un= *】

■ SEARCH OVERLOAD TIMES

Operation display Illustration
【 MR 】 【SHIFT】
【CLEAR】 【OL= ***** 】 Display times of overload

■ VOLTAGE DISPLAY

Operation display Illustration
【 MR 】 【SHIFT】
【 F1 】 【U X.XX】 Display show current voltage of the battery
【 MR 】 【    0】 Return to weigh

■ TURN OFF

Operation display Illustration
【OFF】 【 OFF 】
【U X.XX】 Display show current voltage of battery then turn off

CAS BLDG., # 440-1, SUNGNAE-DONG,
GANGDONG-GU, SEOUL, KOREA
TEL 82 2 2225 3500 FAX 82 2 475 4668
www.gtobalcas.com
Specifications are subject to change for improvement without prior notice.
9002-1E0-0033-0 2008.06

Read User Manual Online (PDF format)