Revitive Essential Circulation Booster and Foot and Leg Cream User Guide
- June 16, 2024
- REVITIVE
Table of Contents
Revitive Essential Circulation Booster and Foot and Leg Cream
Product Information
Specifications
- Product Name: Revitive
- Function: Electrical Stimulation Device for Feet
- Intensity Levels: Up to 50
- Power Source: AC Adaptor
Product Usage Instructions
Troubleshooting Steps
Issue: Unable to Feel Electrical Stimulation
Possible Cause: Not placing both bare feet on the foot-pads at the same time.
Solution
- Ensure that your feet are bare.
- Place each foot on each of the foot-pads at the same time.
- Keep increasing the intensity up to a maximum of 50 until you feel the stimulation.
Possible Cause: Your feet may be dry.
Solution
- Moisturize the soles of your feet to improve conductivity and stimulation.
- Try the procedure again, increasing the intensity level if necessary.
Possible Cause: You may be dehydrated.
Solution
- Drink plenty of water before and after using the device to ensure proper hydration.
Possible Cause: The intensity level may be on too low a setting.
Solution
- Keep increasing the intensity level towards 50 until you feel the stimulation.
- Find a setting that is comfortable for you, rather than aiming for maximum intensity.
Possible Cause: Electrode cord is connected to the device.
Solution
- Disconnect the Electrode cord as the foot-pads will not work while it is plugged in.
If, having tried the solutions above, you still cannot feel the stimulation:
- Test the device by placing one hand across both footpads at the same time (preferably at the heel end of the footpads).
- With your other hand, start from zero and increase the intensity level until you can feel the stimulation through your hand.
- If you can feel the stimulation through your hand, the device is working.
- If you still cannot feel the stimulation on intensity level 50, please contact your authorized dealer.
Issue: No Power or Lights to Revitive
Possible Cause: AC Adaptor not switched on at the electrical socket or not plugged into the device properly.
Solution
- Check if the AC Adaptor is switched on at the electrical socket.
- Ensure that the AC Adaptor is properly plugged into the device.
Issue: Revitive is Not Vibrating
Solution: REVITIVE IS NOT DESIGNED TO VIBRATE.
It functions through electrical stimulation rather than vibration.
Issue: Legs Aching After Treatment
Possible Cause: Intensity set too high, causing overworked muscles.
Solution
- Leave adequate time after each treatment for the muscles to recover, similar to after vigorous exercise.
- On your next session, start on a lower intensity setting where you can feel mild electrical stimulation and it i comfortable.
- Gradually reduce the duration of the session until your muscles have acclimatized to the stimulation.
FAQ (Frequently Asked Questions)
-
Q: Is Revitive safe to use?
A: Yes, Revitive is a very safe device to use. -
Q: How do I increase the intensity level?
A: Keep increasing the intensity level towards 50 until you feel the stimulation. Find a setting that is comfortable for you. -
Q: Can I use Revitive with socks on?
A: No, for optimal conductivity and stimulation, ensure that your feet are bare when using Revitive. -
Q: What should I do if I still cannot feel the stimulation?
A: Test the device by placing one hand across both footpads. If you can feel the stimulation through your hand, the device is working. If not, please contact your authorized dealer. -
Q: How long should I wait between treatments?
A: Leave adequate time for the muscles to recover after each treatment, similar to after vigorous exercise.
TROUBLESHOOTING STEPS
Revitive is on but I cannot feel the electrical stimulation through the foot pads
Possible Cause | Solution |
---|---|
Not placing both bare feet on the foot-pads at the same time. | Ensure that |
your feet are bare and each foot is placed on each of the foot-pads at the
same time. Keep increasing the intensity up to a maximum of 50 until you feel
the stimulation.
Your feet may be dry.| Moisturise the soles of your feet to improve
conductivity and stimulation and try the procedure again. You may also have to
increase the intensity level.
You may be dehydrated.| Drink plenty of water before and after using the
device. The device uses your body to create the electrical circuit. Water is
an excellent conductor of electricity and if your body is less hydrated (below
60%) then the stimulation may be less, therefore it is important to always
remain well hydrated.
The intensity level may be on too low a setting.| This is a very safe device.
Keep increasing the intensity level towards 50 until you feel the stimulation.
You may find that you have to increase the intensity level as you get used to
the therapy. The aim is not to get to 50 but to find a setting that is
comfortable for you.
Electrode cord is connected to device.| Disconnect the Electrode cord – the
foot-pads will not work while the Electrode cord is plugged in.
If, having tried the solutions above, you still cannot feel the stimulation:|
Test the device by placing one hand across both footpads at the same time (The
heel end of the footpads is easiest). With your other hand, and starting from
zero, increase the intensity level until you can feel the stimulation. If you
can feel the stimulation through your hand then the device is working. If on
50 you still cannot feel the stimulation then please contact your authorised
dealer.
No power or lights to Revitive when it is switched on.
Possible Cause | Solution |
---|
AC Adaptor not switched on at the electrical socket or AC Adaptor not plugged into device properly.| Check electrical socket power is switched on and the AC Adaptor is plugged into the device correctly. If still not working – contact your authorised dealer.
Revitive is not vibrating.
- REVITIVE IS NOT DESIGNED TO VIBRATE.
My legs are aching after treatment.
Possible Cause | Solution |
---|
You may have the intensity on too high a setting and your muscles are being overworked.| Leave adequate time after each treatment to allow the muscles to recover ( just like after vigorous exercise!). On your next session start on a lower setting (where you can feel the mild electrical stimulation and it is comfortable) and reduce the duration until your muscles have acclimatized to the stimulation.