PRECAUTIONS
To ensure that you get the most from your scale, please follow these instruction.
Warning
-
Do not disassemble the scale.When any damage or defect occurs, contact your CAS authorized dealer immediately for proper repair.
-
Do not overload beyond the maximum weight limit.
-
Scale must be grounded to minimize electricity static. This will minimize defect or electric shock.
-
Do not pull the plug by its cord when unplugging. Damaged cord could cause electric shock or fire.
-
To prevent from fire occurring, Do not place or use the scale near flammable or corrosive gas.
-
To reduce electric shock or incorrect reading, Do not spill water on the scale or place it in humid condition.
-
Avoid placing the scale near heater or in direct sunlight.
-
Insert plug firmly to wall outlet to prevent electric shock.
The socket-outlet shall be installed near the equipment and shall be easily accessible.Make sure to plug your scale into the proper power outlet. For maximum performance, plug into a power outlet 30 minutes before the usage for warm up.
-
For consistent and accurate reading, maintain periodical check by your CAS authorized dealer.
-
Avoid sudden shock to the scale.
Internal mechanism could be damaged. -
Grab on the bottom of the scale when moving. Do not hold by the platter.
-
Place the scale on firm and temperature consistent environment.
-
If the scale is not properly level, please adjust the 4 legsat the bottom of the scale (turn legs clockwise or counterclockwise) so as to center the bubble of the leveling gauge inside the indicated circle.
-
Keep the scale away from other electromagnetic generating devices. This may interfere with accurate reading.
PREFACE
Thank you for purchasing your CAS PD-II sacle.
CAS scales are designed and produced under rigid quality control to deliver
outstanding performance, reliability and long life.
This manual will help you with the proper operation and care of your new CAS
PD-II.
Please review the PD-II sacle manual before you use the scale and keep it
handy for future reference.
NAMES AND FUNCTIONS
OVERALL VIEW
KEYBOARD
DISPLAY
KEY FUNCTIONS
KEY | DESCRIPTION |
---|---|
Used to set the zero point to 0.00 or 0.000. Used as ESC key in Setup Mode. | |
Used as ENTER key in Setup Mode. | |
Used as Scroll key in Setup Mode. |
OPERATIONS
-
General Weighing
The display indicates ZERO symbol, if weight is at ZERO.
When the display is not zero though there is nothing on the platter, press the ZERO key.
1) Turn on the power. The display shows 0.00 or 0.000.
Make sure that ST(Stable) and ZERO lamps are On.
2) Place an item on the platter. When the ST(Stable) lamp is 0n, read the weight. -
ECR Interface
PD-II can interface with most ECRs by selecting TYPE 0 to TYPE 6
ECR Type Selection 1) Make sure that power is OFF. While pressing “#” key, turn on the power. “EcrSEt” is shown on the disply. And then current ECR type is shown on the display as “tYPE-2”.
2) If you select ECR type 5, press the ” ” key until the display shows “tYPE-5”. (Refer to Table 1.)
3) To save current ECR type, press the ZERO key
| MENU| Description
---|---|---
4-Bit Parallel| RS-232 Serial
key| ECR-TYPE 0| TEC 4 Digit 4Bit Parallel (New kg)| Most POS, ECRs and Some
TEC POS System
ECR-TYPE 1| TEC 4 Digit 4Bit Parallel (Old kg)
ECR-TYPE 2| Universal 4 Bit Parallel| Sharp ER-Axxx, New Sanyo ECRs using
RS-232 others
ECR-TYPE 3| Most POS System
ECR-TYPE 4| Samsung, CRS, NCR2170 and other ECRs
ECR-TYPE 5| NCI General.
Most POS Software
ECRTYPE 6| Samsung ER-670
Serial Communication
9600 Baud Rate, 7 Date bit, Even Parity. 1 Stop bit
ERROR MESSAGE
ERROR | REASONS | SOLUTIONS |
---|---|---|
Err | Failure of A / D Module | Call your CAS dealer |
Err 1 | An error of initial zero range | Set the platter empty Make sure there |
is a platter on the scale
SPECIFICATIONS
MODEL | 15 lb | 30 lb | 60 lb | 150 lb |
---|---|---|---|---|
DIVISION | DUAL INTERVAL | 6 lb 0.002 lb 15 lb 0.005 lb | 15 lb 0.005 lb 30 lb | |
0.01 lb | 30 lb 0.01lb 60 lb 0.02 lb | 60 lb 0.02 lb 150 lb 0.05 lb | ||
INTERNAL RESOLUTION | 1 / 90,000 | |||
EXTERNAL RESOLUTION | 1 / 3,000 DUAL | |||
DISPLAY | VFD 6 DIGITS | |||
DISPLAY LAMP | ST(STABLE), ZERO | |||
INTERFACE | RS-232C, 4-Bit Parallel Communication (ECR Interface) | |||
PRODUCT SIZE | 380(W) 280(D) 79(H) [mm] | |||
PLATTER SIZE | 380(W) 280(D) [mm] | |||
PRODUCT WEIGHT | 6.7kg | |||
TEMPERATURE RANGE | 10 ° C 40 ° C | |||
POWER SUPPLY | AC 120V / 60Hz |
ERROR MESSAGE
ERROR | REASONS | SOLUTIONS |
---|---|---|
Err | Failure of A / D Module | Call your CAS dealer |
Err 1 | An error of initial zero range | Set the platter empty |
Make sure there is a platter on the scale
Read User Manual Online (PDF format)