EUROPLAST Eextra Series EET Electric Fans Instruction Manual

June 10, 2024
EUROPLAST

EUROPLAST -logo

EUROPLAST Eextra Series EET Electric Fans 

EUROPLAST-Eextra-Series-EET-
Electric-Fans-Product-image

Product Information: Model eextra, Series EET

  • Brand: Europlast
  • Power: 32W-40W
  • Voltage: 220-240V~
  • Frequency: 50Hz-100Hz
  • Airflow rate: 2100m3/h – 2550m3/h
  • Noise level: 34dB(A) – 43dB(A)
  • Weight: 0.43kg – 0.66kg
  • Dimensions: A-145mm – 195mm, B-145mm – 195mm, C-80mm, D-99mm – 149mm, E-35mm
  • Protection: IPX4

Product Usage Instructions:

  1. Before setting up the ventilator, turn off the power supply where you plan to set up the ventilator.

  2. Ensure that there are no damages to the ventilator while unpacking it.

  3. Keep the purchase receipt with the warranty card to claim warranty in case of any issues.

  4. Before installation, check if the voltage and frequency of the electrical supply match the specifications.

  5. When connecting the ventilator, pay attention to polarity.

  6. The product can be used by children above 8 years of age and people with physical or mental disabilities only if they are
    familiar with the instructions and safety rules. Children should not operate the device without adult supervision.

  7. The ventilator is equipped with two ball bearings of an electric motor.

  8. The ventilator is connected to the power supply socket using a retractable cord and a cable.

  9. The ventilator is turned on and off by pulling down the cord located at the bottom of the ventilator.

  10. The ventilator is turned on by an electric switch S1(Zm.4) or after the light is turned on in case of S(Zm.5). After turning off
    the light or switch, the ventilator continues to operate for a certain time period set by the regulator (Zm.6) which can range
    from 1 to 30 minutes. Do not use a LED light indicator to power the ventilator’s switch S1 (Zm.4, zm.5).

  11. The ventilator equipped with a timer is turned on and off using a retractable cord. It turns off after a set time interval. To adjust the timer, refer to the Timer T section.

  12. The ventilator equipped with a humid sensor, timer, cord, and switch functions are turned on using a retractable cord or after increasing the humidity level in the room. It turns off after a set time interval or when humidity levels decrease in the room. To adjust the humid sensor, refer to the Humidity Sensor HT section.

  13. The ventilator is equipped with a 12V motor and is designed to be set up with a 12V power supply block.

  14. Electronic control block ventilators must be adjusted before connecting them to the power supply.

Model extra Series EET

EUROPLAST-Eextra-Series-EET-Electric-Fans-01

www.europlast.lv

EUROPLAST-Eextra-Series-EET-Electric-Fans-02 EUROPLAST-Eextra-Series-EET-Electric-Fans-03

EUROPLAST-Eextra-Series-EET-Electric-Fans-04

EUROPLAST-Eextra-Series-EET-Electric-Fans-05

EUROPLAST-Eextra-Series-EET-Electric-Fans-06

Caution
Read the manual carefully before installing and using of the fan.

Caution
Make sure that there are no visual defects when unpacking the fan.

Caution
We do recommend you to save the bill of purchase with stamped guarantee coupon, for the purpose of possible reclamation. Otherwise guarantee will be not in legal force.

Caution
Before connecting to the mains supply ensure that mains voltage (V) and frequency (Hz) corresponds to the parameters on the rating plate.

Caution
When connecting the fan, it is important to follow the polarity (see Installation and Maintenance)

Caution
This device may be used by children starting from age of 8 as well as people with physical or mental disorders, given that they are familiar with the manual and safety provisions in respect to this device. It is prohibited for children to play with the device. Children may not carry out maintenance or cleaning of this device without supervision of adults.

Technical information| EET100| EET120| EET125| EET150
---|---|---|---|---
Voltage (V)| 220 – 240
Phase (Hz)| 50
Power (W)| 15| 16| 16| 20
Suction power (m3/h)| 100| 145| 150| 200
Noise level: 3m distance, Lp A dB(A)| 32| 34| 36| 40
Protection against environmental factor| IPX4
RPM| 2550| 2400| 2360| 2100
Ambient temperature| +5°C … +40°C
Weight (kg)| 0,43| 0,52| 0,52| 0,66
Sizes,

mm

| EET100| EET120| EET125| EET150
---|---|---|---|---
A| 145| 170| 170| 195
B| 145| 170| 170| 195
C| 80| 80| 80| 80
D| 99| 119| 124| 149
E| 35| 35| 35| 35

EUROPLAST-Eextra-Series-EET-Electric-Fans-06

Installation and Maintenance

Caution
Before installation, disconnect the power network where you are planning on installing the fan.

Caution
Installation may be carried out only by a qualified electrician. Before mounting, the cover part of the ventilator must be removed by pressing with a screwdriver on two locks under the case (Image 1). The ventilator must be mounted in a ventilation duct by attaching the ventilator on the wall by the use of screws (Image 2). The base model ventilators, ventilators with a switch (W), ventilators with a timer (T), ventilators with a humidity sensor and timer (HT) must be connected to the electrical network. Under the cover, there are N-L or N-L-S clamps to which the electrical network must be properly connected (Images 3-5). When connecting the ventilator with the voltage, it is important to observe polarity and connect the line wire with L-clamp and neutral wire with N-clamp. When connecting the fan to electricity, it is important to take into account polarity and connect the live wire to the Terminal L and the neutral wire to the Terminal N. In case if the fan is directly connected to the electric power network, the power network must be equipped with a switch that ensures safe disconnection of the power supply.

Bearing B
In addition, the fan is equipped with two ball bearings inside of the electric motor. EN

Switch and Cable WP
A fan that is equipped with a pull-down switch and cable shall be connoted to a power outlet. The fan is turned on and off by pulling down the string that is located on the bottom of the fan.

Timer T
The fan is turned on by the S1 power switch (Drawing 4) or by turning on the light (Drawing 5). After turning off the light or the switch, the fan continues its operation for a specific time interval that is set up by a controller. This interval may be 1 to 30 minutes long.

Caution
The fan power switch S1 (Drawing 4, drawing 5) must not be equipped with an LED light indicator.

Humidity Sensor HT
The fan is equipped with a humidity level control that may be used to set the level of humidity from ~60%RH – ~90%RH and a delay control that may be used to set the delay from 1 to 30 min. The fan is turned on automatically when a certain humidity level is reached in the room or it may be turned on manually by a switch. Connection diagram is shown in Drawing 4-5. The fan is turned off after a pre-set time interval. Humidity “H” and delay “T” controllers are located on the control unit (Drawing 7). To set the maximum humidity level (~ 90% RH) for moisture regulator “H” need turned fully clockwise.

Caution
The fan power switch S1 (Drawing 4, drawing 5) must not be equipped with an LED light indicator.

Timer, Cable, and Switch TWP
A fan that is equipped with a timer, cable, and switch is turned on by a pull- down switch. It will turn off after the pre-set time interval. To adjust the timer, see section “Timer T”.

Humidity Sensor, Timer, Cable, and Switch HTWP
A fan that is equipped with a humidity sensor, cable, and switch is turned on by a pull-down switch or after a certain humidity level is reached in the room. It turns on after the pre-set time interval or if humidity in the room drops to a certain level. To adjust the humidity sensor, see section “Humidity Sensor HT”.

12V motor – 12
The fan is equipped with a 12V motor. A fan intended to be installed together with 12V power supply.

Caution
Fans with electronic control unit must be adjusted before they are connected to the power network.

Caution
If the potentiometer is set to “1 min”, the fan will turn on for a couple of seconds after connected it to the power network.

Guarantee

Producer guarantee is 24 months In the case of damages contact the place of trade. The guarantee does not cover:

  1. Noted mechanical or other damages
  2. Mechanical or other damages caused by incorrect or improper usage, misuse, abuse or neglect
  3. Mechanical or other damages caused by incorrect installation or by product’s incorrect fitting to insufficient or unsuitable power
  4. Mechanical or other damages caused by ignoring the instruction manual conditions
    A guarantee does not cover natural wear of the product.

Utilization
Information for Users on Disposal of Old Equipment. This symbol indicates that the electrical and electronic equipment should not be disposed of as general household waste at its end of life. Instead, the products should be handed over to the appliance collection points for the recycling of electrical and electronic equipment, recovery and recycling in accordance with your national legislation and the Directive 2002/96/EC and 2006/66/EC.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals