Eterna KCIRSTD Colour Temperature Selectable Circular LED Ceiling Wall Light Installation Guide

June 13, 2024
Eterna

**Eterna KCIRSTD Colour Temperature Selectable Circular LED Ceiling Wall Light Installation Guide


**

READ THIS FIRST

Check the pack and make sure you have all of the parts listed on the front of this booklet. If not, contact the outlet where you bought this product.

This product must be installed by a competent person in accordance with the current building and IEE wiring regulations.

As the buyer, installer and/or user of this product it is your own responsibility to ensure that this fitting is fit for the purpose for which you have intended it. Eterna Lighting cannot accept any liability for loss, damage or premature failure resulting from inappropriate use.

This product is designed and constructed according to the principles of the appropriate British Standard and is intended for normal domestic service. Using this fitting in any other environments may result in a shortened working life, for example where there is prolonged periods of use or higher than normal ambient temperatures such as lighting public or shared spaces or in nursing /care home facilities.

Switch off the mains before commencing installation and remove the appropriate circuit fuse or lock off MCB.

This product is suitable for use in living areas, and Bathroom Zone 2 and outsides of zones.

If being fitted in a bathroom a 30mA RCD must be used.
Bathroom Zones Diagram

This product is designed for permanent connection to fixed wiring: this must be a suitable circuit (protected with the appropriate MCB or fuse).

This product is suitable for installation on surfaces with normal flammability e.g. wood, plasterboard and masonry. It is not suitable for use on highly flammable surfaces (e.g. polystyrene, textiles).

Before making fixing hole(s), check that there are no obstructions hidden beneath the mounting surface such as pipes or cables.

The chosen location of your new fitting should allow for the product to be securely mounted (e.g. to a ceiling joist) and safely connected to the mains supply (lighting circuit).

When making connections ensure that the terminals are tightened securely and that no strands of wire protrude. Check that the terminals are tightened onto the bared conductors and not onto any insulation.

This product is double insulated, do not connect any part to Earth.

This product is not intended to be used by children and persons with sensory, physical and/or mental impairments that would prevent them from using it safely.

You are advised at every stage of your installation to double-check any electrical connections you have made. After you have completed your installation there are electrical tests that should be carried out, these tests are specified in the current IEE wiring and building regulations.

LAMP REPLACEMENT

The light source is designed to last the lifetime of the luminaire.

The light source contained in this luminaire shall only be replaced by the manufacturer, service agent or a similar qualified person.


CAUTION, RISK OF ELECTRIC SHOCK.

INSTALLATION

Choose the location for your new fitting according to the conditions listed opposite.

  1. Hold the base of the fitting and gently turn the diffuser and decorative trim anti-clockwise and lift off.
  2. Loosen screw on LED turnbuckle and rotate to release the tray which will then hinge to allow access to the wiring terminals.
  3. Drill holes in the back of your fitting for your fixing screws, take care and drill gently to ensure a clean hole through. Use a drill bit sized appropriately to your fixing screws.
  4. Using the back of your fitting as a template, mark the position of your fixing holes on your mounting surface.
  5. Prepare the holes in your mounting surface as appropriate for your fixings.
  6. Pierce the rubber grommet in the back of your fitting making a hole just large enough to make a tight fit around the incoming mains cable.
  7. Thread the cable through the grommet and offer the fitting to the ceiling/wall.
  8. Secure the fitting in place. Note, if protection against ingress of moisture is required, the heads of screws must be covered with a silicone or similar sealant.
  9. Check that the grommet is still correctly fitted in the cable entry hole and around the incoming cable.
  10. Make the electrical connections to the terminal block according to the markings: Brown to live (L) Blue to neutral (N)
  11. Set colour temperature to the desired option by selecting appropriate switch setting on the driver.
    DL| Daylight| 6000K
    ---|---|---
    CW| Cool White| 4200K
    WW| Warm White| 3000K
  12. Replace gear tray and secure in position.
  13. Offer the diffuser and decorative trim onto the top of the fitting and turn clockwise until they are held securely.
  14. Restore the power and switch on.

NOTE: In warm white (3000K) and daylight white (6000K) operation only one set of LEDs will illuminate, in cool white (4200K) both sets of LEDs will illuminate.

EVENTUALLY, YOU MAY WANT TO REPLACE THIS PRODUCT

Regulations require the recycling of Waste from Electrical and Electronic Equipment (European “WEEE Directive” effective August 2005—UK WEEE Regulations effective 2nd January 2007). Environment Agency Registered Producer: WEE/ GA0248QZ.

WHEN YOUR PRODUCT COMES TO THE END OF ITS LIFE OR YOU CHOOSE TO REPLACE IT, PLEASE RECYCLE IT WHERE FACILITIES EXIST – DO NOT DISPOSE WITH HOUSEHOLD WASTE.

CLEANING

Clean this fitting only with a soft dry cloth.
Do not use any chemical or abrasive cleaners.

IF YOU EXPERIENCE PROBLEMS

If you believe your product is defective, please return it to the place where you bought it. Our Technical Team will gladly advise on any Eterna Lighting product, but may not be able to give specific instructions regarding individual installations.

An Earth connection is not required for the operation of these Class II luminaires. The addition of the Earth terminal provides a loop-in/loop out facility which allows connectivity through to other Class I luminaires in the same lighting circuit.
Earth connection

See website for more information on replacability and recycling.
Installation

LED LAMP SPECIFICATIONS

Luminaire lumens (with diffuser): Warm White, Cool White, Daylight White| 1560 lm 1670 lm 1600 lm
---|---
** Lumens from chip (array): Warm White, Cool White, Daylight White| 1760 lm 1880 lm 1800 lm
**
Useful lumens (array): Warm White, Cool White, Daylight White| 1400 lm 1500 lm 1440 lm
Rated Wattage| 14W
Rated luminous flux| 1400/1500/1440 lm
Nominal life time of the lamp| 50,000 hrs
Colour temperature| 3000/4200/6000K
Number of switching cycles before premature lamp failure| **** ≥15,000
Warm-up time up to 60% of the full light output| Instant full light
Dimmable| No
Nominal beam angle| 120°
Rated power| 14W
Rated lamp lifetime| 50,000 hrs
Displacement factor| ≥0.8
Lumen maintenance factor at end of nominal life| ≥0.8
Starting time| Instant full light
Colour rendering| ≥80 Ra
Colour consistency| Within 6 step Macadam ellipse
Rated peak intensity| 445cd
Rated beam angle| 120°
Voltage / Frequency| 240V~50Hz
Lumen efficacy: 111/119/114 lm / W
This product contains a Light Source of Energy Efficiency Class E

Symbols
Symbols

Email: sales@eterna-lighting.co.uk / technical@eterna-lighting.co.uk
Issue 1021 Visit our website: www.eterna-lighting.co.uk

Colour Temperature Selectable Circular LED Ceiling/Wall Light These instructions are provided as a guideline to assist you.
PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLATION AND RETAIN FOR FUTURE REFERENCE

Eterna Logo

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Eterna User Manuals

Related Manuals