Eterna HBCIR150PP 150W Dimmable LED Circular High Bay Instruction Manual
- June 4, 2024
- Eterna
Table of Contents
Everyday Lighting For professionals
INSTALLATION INSTRUCTIONS
A guide for qualified electricians
HBCIRDIF90 90° aluminum reflector for HBCIR100, HBCIR150, HBCIR150PP
| Pack contents: 1 x LED ceiling fitting Reflector fixing screws
---|---
Model: HBCIR150PP 150W Dimmable LED Circular High Bay With Lifud Driver
These instructions are provided as a guideline to assist you.
PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLATION AND RETAIN FOR FUTURE
REFERENCE
READ THIS FIRST:
Check the pack and make sure you have all of the parts listed on the front of
this booklet. If not, contact the outlet where you bought this product.
This product must be installed by a competent person in accordance with the
current building and IEE wiring regulations.
As the buyer, installer and/or user of this product it is your own
responsibility to ensure that this fitting is fit for the purpose for which
you have intended it. Eterna Lighting cannot accept any liability for loss,
damage or premature failure resulting from inappropriate use.
This product is designed and constructed according to the principles of the
appropriate British Standard.
Using this fitting in an environment where there are prolonged periods of use
or higher than normal ambient temperatures may result in a shortened working
life
Switch off the mains before commencing installation and remove the appropriate
circuit fuse or lock off MCB.
This product is designed for permanent connection to fixed wiring: this must
be a suitable circuit (protected with the appropriate MCB or fuse).
Make sure that the fixings are strong enough to support the weight of the
fitting and hold it securely.
This product must be connected to earth termination.
Live – Brown or Red
Neutral – Blue or Black
Earth – Green, and Yellow
When working at heights ensure you use a suitable platform.
The luminaire must be positioned so that there is at least 0.5m (500mm)
between the luminaire and any illuminated surface.
When making connections ensure that the terminals are tightened securely and
that no strands of wire protruding. Check that the terminals are tightened
onto the bared conductors and not onto any insulation.
You are advised at every stage of your installation to double-check any
electrical connections you have made. After you have completed your
installation there are electrical tests that should be carried out, these
tests are specified in the current IEE wiring and building regulations. If in
doubt, consult a qualified electrician.
LAMP REPLACEMENT:
The light source is designed to last the lifetime of the luminaire.
The light source contained in this luminaire shall only be replaced by the
manufacturer, service agent, or a similarly qualified person.
CAUTION, RISK OF ELECTRIC SHOCK.
INSTALLATION:
-
Choose the location for your new light fitting giving consideration to the opposite of the point.
-
Isolate the mains.
-
Secure fitting in place using the hanging hook.
Ensure the safety cable is suitably fixed. -
Terminate the loose ends of the wire to an appropriate junction box or similar, ensuring the below is observed:
Live – Brown/Red
Neutral – Blue/Black
Earth – Yellow/Green -
This luminaire is 1-10V dimmable as standard, if you wish to dim this fitting, ensure that you connect the 1-10V dimming control wires to a 1-10V dimming system only. If no dimming is required please leave the terminals isolated.
1-10V Dim + Blue
1-10V Dim – White -
Restore power and test the luminaire.
NOTE: If installing with a separately supplied reflector, please refer to the opposite picture for guidance.
Please note the aluminum reflector connects to the fitting with the three screws as shown opposite
LED LAMP SPECIFICATIONS:
Luminaire lumens (with diffuser) | 25400 Im |
---|---|
Lumens from the chip (no diffuser) a | 29000 Im |
Useful lumens | 21310 Im |
Sated Wattage | 150W |
Rated luminous flux a | 21310Im |
A nominal lifetime of the lamp a | 50,000 hrs |
Color temperature | 3500K |
Number of switching cycles before premature lamp failure | 25,000 |
Warm-up time up to 60% of the full light output a | Instant full light |
Dimmable | Yes |
Nominal beam angle s | 120° |
rated power | 150W |
Rated lamp lifetime | – a |
50,000 hrs
Lamp Lamp power factor| >0.9
Lumen maintenance factor at end of nominal life| ≥0.80
Starting time| <0.5s
Color rendering a| .≥70
Colour consistency a| Within a six-step Macadam ellipse
Rated peak intensity| 6994cd
Sated beam angle| 120°
Voltage / Frequency| 240V—SOHC
Not suitable for accent
EVENTUALLY, YOU MAY WANT TO REPLACE THIS PRODUCT:
Regulations require the recycling of Waste from Electrical and Electronic
Equipment (European “WEEE Directive” effective August 2005—UK WEEE
Regulations effective 2nd January 2007). Environment Agency Registered
Producer: WEE/ GA0248QZ.
WHEN YOUR PRODUCT COMES TO THE END OF ITS LIFE OR YOU CHOOSE TO REPLACE IT,
PLEASE RECYCLE IT WHERE FACILITIES EXIST – DO NOT DISPOSE OF WITH HOUSEHOLD
WASTE.
CLEANING:
Clean this product only with a soft dry cloth.
Disconnect the power and clean the exterior only of this fitting with a moist
(not wet) cloth.
Do not use any chemical or abrasive cleaners.
IF YOU EXPERIENCE PROBLEMS:
If you believe your product is defective, please return it to the place where
you bought it. Our Technical Team will gladly advise on any Eterna Lighting
product, but may not be able to give specific instructions regarding
individual installations.
Email: sales@eterna-lighting.co.uk
technical@eterna-lighting.co.uk
Visit our website: www.eterna-lighting.co.uk
Issue 0322
Made in China
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>