Eterna CHA18MW Colour and Wattage Adjustable LED Ceiling Light Instruction Manual
- June 4, 2024
- Eterna
Table of Contents
Everyday Lighting For Professional
INSTALLATION INSTRUCTIONS
A guide for qualified electricians
Model: CHA18MW
Power and Colour Temperature Selectable Circular LED
Ceiling/Wall Light With Microwave Sensor
These instructions are provided as a guideline to assist you.
PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLATION
AND RETAIN FOR FUTURE REFERENCE
Pack contents:
1 x LED ceiling fitting
1 x Fixing kit
READ THIS FIRST:
Check the pack and make sure you have all of the parts listed on the front of
this booklet. If not, contact the outlet where you bought this product.
This product must be installed by a competent person in accordance with the
current building and IEE wiring regulations.
As the buyer, installer, and/or user of this product it is your own
responsibility to ensure that this fitting is fit for the purpose for which
you have intended it. Eterna Lighting cannot accept any liability for loss,
damage, or premature failure resulting from inappropriate use.
This product is designed and constructed according to the principles of the
appropriate British Standards and is intended for normal domestic service.
Using this fitting in any other environment may result in a shortened working
life, for example where there are prolonged periods of use or higher than
normal ambient temperatures such as lighting public or shared spaces or in
nursing /care home facilities. Switch off the mains before commencing
installation and remove the appropriate circuit fuse or lock off MCB.
This product is suitable for use in living areas, Bathroom Zone 2, and
outsides of zones.
If being fitted in a bathroom a 30mA RCD must be used.
This product is designed for permanent connection to fixed wiring: this must
be a suitable circuit (protected with the appropriate MCB or fuse).
This product is suitable for installation on surfaces with normal flammability
e.g. wood, plasterboard, and masonry. It is not suitable for use on highly
flammable surfaces (e.g. polystyrene, textiles).
Before making fixing the hole(s), check that there are no obstructions hidden
beneath the mounting surface such as pipes or cables.
NOTE: In warm white (3000K) and daylight white (6500K) operation only one
set of LEDs will illuminate, in cool white (4400K) both sets of LEDs will
illuminate.
The chosen location of your new fitting should allow for the product to be
securely mounted (e.g. to a ceiling joist) and safely connected to the mains
supply (lighting circuit).
When making connections ensure that the terminals are tightened securely and
that no strands of wire protruding. Check that the terminals are tightened
onto the bared conductors and not onto any insulation.
This product is double insulated. Do not connect any part to Earth.
This product is not intended to be used by children and persons with sensory,
physical, and/or mental impairments that would prevent them from using it
safely.
You are advised at every stage of your installation to double-check any
electrical connections you have made. After you have completed your
installation there are electrical tests that should be carried out, these
tests are specified in the current IEE wiring and building regulations.
INTRODUCTION:
The ceiling/wall light incorporates a microwave sensing device that
continuously scans the operating zone and immediately switches the light on
when it detects movement in that area.
This means that whenever motion is detected within the range of the sensor the
light will switch on automatically and illuminate the area you have selected
to light. While there is a movement within range of the unit the light will
remain on.
A microwave sensor is an active motion detector emitting high-frequency
electromagnetic waves at 5.8GHz and receiving their echo. The sensor detects
a change in the echo pattern within its detection zone and the light is then
triggered. The wave can pass through doors, glass, and thin walls and will
continually monitor the signal within the detection area.
INSTALLATION:
Choose the location for your new fitting according to the conditions listed opposite.
-
Hold the base of the fitting and gently turn the diffuser and decorative trim anti-clockwise and lift off.
-
Loosen the screw on the LED turnbuckle and rotate to release the tray which will then hinge to allow access to the wiring terminals.
-
Drill holes in the back of your fitting for your fixing screws, take care and drill gently to ensure a clean hole through. Use a drill bit sized appropriately to your fixing screws.
-
Using the back of your fitting as a template, mark the position of your fixing holes on your mounting surface.
-
Prepare the holes in your mounting surface as appropriate for your fixings.
-
Pierce the rubber grommet in the back of your fitting making a hole just large enough to make a tight fit around the incoming mains cable.
-
Thread the cable through the grommet and offer the fitting to the ceiling/wall.
-
Secure the fitting in place. Note, if protection against ingress of moisture is required, the heads of screws must be covered with silicone or similar sealant.
-
Check that the grommet is still correctly fitted in the cable entry hole and around the incoming cable.
-
Make the electrical connections to the terminal block according to the markings:
Brown to live (L)
Blue to neutral (N) -
Set power to the desired option by selecting the appropriate switch setting on the driver: 9W / 14W / 18W options
-
Set color temperature to the desired option by selecting the appropriate switch setting on the driver.
DL| Daylight| 6500K
---|---|---
CW| Cool White| 4400K
WW| Warm White| 3000K -
Set desired settings on microwave.
-
Replace gear tray and secure in position.
-
Offer the diffuser and decorative trim onto the top of the fitting and turn clockwise until they are held securely.
-
Restore the power and switch it on.
UNDERSTANDING THE CONTROLS:
REFER TO THE MICROWAVE SENSOR PICTURE OPPOSITE
The sensor is an active motion detector: it emits a high-frequency
electromagnetic wave 5.8GHz and receives its echo. The sensor detects the
change in echo from movement in its detection zone. A microprocessor then
triggers the switch light ON command. Detection is possible through doors,
panels of glass, and thin walls.
DETECTION RANGE:
This determines the effective range of the motion detector and is set up by
DIP switches at the sensor itself, refer to figure. Note that reducing the
sensitivity will also narrow the detection range.
DETE CTIO N ARE A
| 1| 2| 3|
I| ON| ON| ON| 100%
II| –| ON| ON| 75%
III| ON| –| ON| 50%
IV| –| –| ON| 25%
V| –| –| –| 10%
HOLD TIME:
This determines the time the fitting remains at 100% level on motion detection
and is set with DIP switches at the sensor itself, refer to figure. The walk
test settings (5sec) is useful when installing the fitting to establish
correct operation and range.
H OLD T IME
| 4| 5| 6|
I| ON| ON| ON| 5s
II| –| ON| ON| The 30s
III| ON| –| ON| The 90s
IV| –| –| ON| 3 mins
V| ON| ON| –| 20 mins
VI| –| –| –| 30 mins
DAYLIGHT SENSOR:
This setting holds off the 100% light output should there be sufficient
daylight and is set using DIP switches at the sensor, refer to figure.
- If the daylight sensor is disabled the sensor will turn on light once motion is detected regardless of the ambient light level.
DAYL IGHT SENS OR
| 7| 8| 9|
I| ON| ON| ON| 2Lux
II| ON| ON| –| 10Lux
III| –| ON| –| 25Lux
IV| ON| –| –| 50Lux
V| –| –| –| Disable*
MICROWAVE SENSOR SPECIFICATIONS:
PRODUCT TYPE | MICROWAVE MOTION SENSOR |
---|---|
Operating Voltage | 220-240VAC 50/60Hz |
HF System | 5.8GHz |
Transmission Power | 1mW Max |
Detection Angle | 150 Degree |
Power Consumption | <0.5W |
Detection Range | Max. 6m adjustable |
Time Setting | 5s-30m |
Mounting | Indoors, ceiling and wall |
Light Control | 2-50lux, disable |
Working Temp | -20 to +60 degree |
Rated Load | 400W (Inductive load) 800W (Resistive load) 270W (LED) |
Eterna Lighting Ltd
RED DIRECTIVE – Microwave Occupancy Sensor
Full declaration available at: www.eterna-lighting.co.uk/red-
declaration
LAMP REPLACEMENT:
The light source is designed to last the lifetime of the luminaire.
The light source contained in this luminaire shall only be replaced by the
manufacturer, service agent, or a similarly qualified person.
CAUTION, RISK OF ELECTRIC SHOCK.
An Earth connection is not required for the operation of these Class II luminaires. The addition of the Earth terminal provides a loop-in/loop-out facility which allows connectivity through to other Class I luminaires in the same lighting circuit.
EVENTUALLY, YOU MAY WANT TO REPLACE THIS PRODUCT:
Regulations require the recycling of Waste from Electrical and Electronic
Equipment (European “WEEE Directive” effective August 2005—UK WEEE Regulations
effective 2nd January 2007). Environment Agency Registered Producer:
WEE/GA0248QZ.
WHEN YOUR PRODUCT COMES TO THE END OF ITS LIFE OR YOU CHOOSE TO REPLACE IT,
PLEASE RECYCLE IT WHERE FACILITIES EXIST – DO NOT DISPOSE OF IT WITH
HOUSEHOLD WASTE.
CLEANING:
Clean this fitting only with a soft dry cloth. Do not use any chemical or
abrasive cleaners.
IF YOU EXPERIENCE PROBLEMS:
If you believe your product is defective, please return it to the place where
you bought it. Our Technical Team will gladly advise on any Eterna Lighting
product, but may not be able to give specific instructions regarding
individual installations.
See the website for more information on replaceability and recycling
LED LAMP SPECIFICATIONS: | 9W | 14W | 18W |
---|
Luminaire lumens (with diffuser): Warm White, Cool White, Daylight
White| 3000K – 1000 lm
4400K – 1100 lm
6500K – 1100 lm| 3000K – 1500 lm
4400K – 1670 lm
6500K – 1640 lm| 3000K – 1880 lm
4400K – 2130 lm
6500K – 2050 lm
Lumens from the chip (array): Warm White, Cool White, Daylight White|
3000K – 1120 lm
4400K – 1220 lm
6500K – 1230 lm| 3000K – 1680 lm
4400K – 1880 lm
6500K – 1850 lm| 3000K – 2120 lm
4400K – 2400 lm
6500K – 2320 lm
Useful lumens (array): Warm White, Cool White, Daylight White| 3000K –
900 lm
4400K – 1000 lm
6500K – 1000 lm| 3000K – 1350 lm
4400K – 1500 lm
6500K – 1480 lm| 3000K – 1700 lm
4400K – 1900 lm
6500K – 1860 lm
Rated Wattage| 9W| 14W| 18W
Rated luminous flux| 3000K – 900 lm
4400K – 1000 lm
6500K – 1000 lm| 3000K – 1350 lm
4400K – 1500 lm
6500K – 1480 lm| 3000K – 1700 lm
4400K – 1900 lm
6500K – 1860 lm
A nominal lifetime of the lamp| 40,000 hrs| 40,000 hrs| 40,000 hrs
Color temperature| 3000/4400/6500K| 3000/4400/6500K| 3000/4400/6500K
Number of switching cycles before premature lamp failure| 5000| 15000| 15000
Warm-up time up to 60% of the full light output| Instant full light| Instant
full light| Instant full light
Dimmable| No| No| No
Nominal beam angle| 120°| 120°| 120°
Rated power| 9W| 14W| 18W
Rated lamp lifetime| 40,000 hrs| 40,000 hrs| 40,000 hrs
Displacement factor| 0.96| 0.96| 0.96
Lumen maintenance factor at end of nominal life| ≥80| ≥80| ≥80
Starting time| Instant full light| Instant full light| Instant full light
Color rendering| ≥80| ≥80| ≥80
Colour consistency| Within 6 step Macadam ellipse| Within 6 step Macadam
ellipse| Within 6 step Macadam ellipse
Rated peak intensity| 3000K – 286cd
4400K – 310cd
6500K – 312cd| 3000K – 432cd
4400K – 484cd
6500K – 746cd| 3000K – 611cd
4400K – 621cd
6500K – 605cd
Rated beam angle| 120°| 120°| 120°
Voltage / Frequency| 240V~50-60Hz| 240V~50-60Hz| 240V~50-60Hz
Lumen efficacy| 3000K – 111 lm / W
4400K – 122 lm / W
6500K – 122 lm / W| 3000K – 107 lm / W
4400K – 119 lm / W
6500K – 117 lm / W| 3000K – 104 lm / W
4400K – 118 lm / W
6500K – 114 lm / W
This product contains a Light Source of Energy Efficiency Class E
Not suitable for accent lighting
Email: sales@eterna-lighting.co.uk /
technical@eterna-lighting.co.uk
Visit our website: www.eterna-lighting.co.uk
Issue 1221
Made in China
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>