Eterna BATL5FTEM3 4ft 5ft and 6ft Li-Ion Emergency LED Battens Instruction Manual

June 4, 2024
Eterna

INSTALLATION INSTRUCTIONS
A guide for qualified electricians
3 HOURS DURATION IN EMERGENCY MODE
Eterna BATL5FTEM3 4ft 5ft and 6ft Li-Ion Emergency LED
Battens
Model:
4ft, 5ft & 6ft Li-Ion Emergency LED Battens
BATL4FTEM3 / BATL5FTEM3 / BATL6FTEM3
5ft & 6ft Li-Ion Emergency High Output LED Battens
BATL5HOEM3 / BATL6HOEM3
These instructions are provided as a guideline to assist you.
PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLATION
AND RETAIN FOR FUTURE REFERENCE

BATL5FTEM3 4ft 5ft and 6ft Li-Ion Emergency LED Battens

Pack contents:
1 x Fitting with the emergency module fitted
1 x Fixing kit

READ THIS FIRST

Check the pack and make sure you have all of the parts listed on the front of this booklet. If not, contact the outlet where you bought this product.
This product must be installed by a competent person in accordance with the current building and IEE wiring regulations.
As the buyer, installer, and/or user of this product it is your own responsibility to ensure that this fitting is fit for the purpose for which you have intended it. Eterna Lighting cannot accept any liability for loss, damage, or premature failure resulting from inappropriate use.
This product is designed and constructed according to the principles of the appropriate British Standard and is intended for normal service. Using this fitting in any other environment may result in a shortened working life, for example where there are prolonged periods of use or higher than normal ambient temperatures.
Switch off the mains before commencing installation and remove the appropriate circuit fuse or lock off MCB. Disconnect the driver from the electrical supply before flash or high voltage testing.
Do not connect to a circuit that also has inductive loads connected; switching of inductive loads will generate spikes which may damage electronic components within your driver.
This unit is suitable for indoor use only.
This product is designed for permanent connection to fixed wiring: this must be a suitable circuit (protected with the appropriate MCB or fuse).
Before making fixing the hole(s), check that there are no obstructions hidden beneath the mounting surface such as pipes or cables.
Make sure that the fixings are strong enough to support the considerable weight of the fitting and hold it rigidly. The chosen location of your new fitting should allow for the product to be securely mounted (e.g. to a ceiling joist) and safely connected to the mains supply (lighting circuit).
When making connections ensure that the terminals are tightened securely and that no strands of wire protruding. Check that the terminals are tightened onto the bared conductors and not onto any insulation.
This product must be connected to earth termination.

This product is not intended to be used by children and persons with sensory, physical, and/or mental impairments that would prevent them from using it safely.
You are advised at every stage of your installation to double-check any electrical connections you have made. After you have completed your installation there are electrical tests that should be carried out, these tests are specified in the current IEE wiring and building regulations.

OPERATION CHECKS

Periodic testing should be carried out to ensure emergency lighting is operating correctly. Interruption of the supply, causing the fitting to be energized from the battery, should be carried out by the operation of a local key switch or another isolation device. During this period all fittings should be examined visually to ensure that they are functioning correctly. At the end of the test period, the supply shall be restored and all indicator lamps or devices checked to ensure that the normal supply has been restored.
DAILY:
Visual inspection of the battery charge LED.
EACH MONTH:
Isolate the power supply for a period sufficient to ensure that each lamp is illuminated. Endorse the test record form supplied.
ONCE EACH YEAR:
Isolate the power supply and check that the light is still illuminated after 3 hours. Endorse the test record form.
Because of the possibility of a failure of the normal lighting supply occurring shortly after a period of testing of the emergency lighting system or during the subsequent recharge period, all full-duration tests shall wherever possible be undertaken preceding time of low risk to allow for battery recharge.
NOTE: Please keep this instruction booklet and the test record in a safe place. A fire officer or other authorized person may want to see your record of inspection and testing.

EMERGENCY DOWNLIGHT

SPECIFICATION

ELF: 0.92

INSTALLATION

  1. Choose the location of your new fitting giving consideration to all of the conditions listed above and the position of the entry points for the mains cable supply.

  2. Carefully detach the LED tray from the main housing.

  3. Unclip the gear tray retaining straps, disconnect the driver plug and detach the earth spade; set the LED tray aside.

  4. Using the back of the fitting as a template, mark the location of the fixing holes on your mounting surface.

  5. Thread the supply cable through the large grommet hole in the back of the fitting.

  6. Secure the fitting in place using suitable fixings and ensure that cables are not trapped behind or inside the fitting.

  7. Make the connections of the supply cable to the terminals inside the fitting following the color coding below:
    PL Permanent Live (Brown)
    SL Switched Live (Brown)
    Earth (Yellow/Green)
    N Neutral (Blue)

  8. Clip the gear tray retaining straps back to the LED tray, re-connect the driver plug to the tray and re-attach the earth spade.

  9. Connect the plug between the battery and emergency control gear and write the commissioning date on the battery.

  10. Attach the LED tray, taking care that no cables are trapped between the tray and housing.

  11. Restore power and switch on.

  12. The emergency downlight will illuminate green during the normal operation which indicates the battery is charging. On mains power failure the emergency LED will illuminate white light continuously for a minimum of three hours.

www.eterna-lighting.co.uk
INSTALLATION, MAINTENANCE
AND OPERATION CHECK RECORD

Product Code: Product Description:

Product Location:
Installation Date:| Installation Test Duration:
Installed By:
Month| Test| Year:| Year:| Year:| Year:| Year:
---|---|---|---|---|---|---
Sign| Date| Sign| Date| Sign| Date| Sign| Date| Sign| Date
01| Short| | | | | | | | | |
02| Short| | | | | | | | | |
03| Short| | | | | | | | | |
04| Short| | | | | | | | | |
05| Short| | | | | | | | | |
06| Short| | | | | | | | | |
07| Short| | | | | | | | | |
08| Short| | | | | | | | | |
09| Short| | | | | | | | | |
10| Short| | | | | | | | | |
11| Short| | | | | | | | | |
12| 3 Hour Endurance| | | | | | | | | |

EVENTUALLY, YOU MAY WANT TO REPLACE THIS PRODUCT:
Regulations require the recycling of Waste from Electrical and Electronic Equipment (European “WEEE Directive” effective August 2005—UK WEEE Regulations effective 2nd January 2007). Environment Agency Registered Producer: WEE/GA0248QZ.
WHEN YOUR PRODUCT COMES TO THE END OF ITS LIFE OR YOU CHOOSE TO REPLACE IT, PLEASE RECYCLE IT WHERE FACILITIES EXIST – DO NOT DISPOSE OF IT WITH HOUSEHOLD WASTE.

INDUSTRIAL BATTERIES

Within certain products, Eterna Lighting Ltd places lead acid, lithium ion, nickel cadmium & nickel metal hydride batteries on the market. Industrial batteries are subject to waste regulation under the Waste Batteries and Accumulators Regulations 2009 and should be disposed of responsibly. Purchasers may be able to dispose of their waste industrial batteries locally via legitimate licensed trade waste contractors. Eterna is obliged to take back, free of charge and within a reasonable time, waste industrial batteries of the same chemistry supplied to a Purchaser, for treatment and recycling and is required to do this in any calendar year new industrial batteries are placed on the market. In certain circumstances, this may include batteries not originally supplied by Eterna. If any Purchaser requires Eterna to take back Industrial batteries, they should write to the Operations Director, Eterna Lighting Ltd, Huxley Close, NN8 6AB, who will then advise on the necessary arrangements for the receipt, proper treatment and recycling of, the waste industrial batteries.

LAMP REPLACEMENT
The light source of this luminaire is not replaceable; when the light source reaches its end of life the whole luminaire shall be replaced.

BATTERY REPLACEMENT:

If after a routine operation check, the lamp does not remain lit for the three-hour period, a new battery pack may be required.

  1. Switch off the electricity at the mains and allow batteries to fully discharge then reconnect to supply and allow charging for 24 hours.
  2. Test again for 3 hours, if the light does not remain lit, then change the battery pack as follows:
  3. Isolate from the mains supply and unplug the battery plug lead from the socket and re-plug the new battery.
  4. Restore power and allow charging for 24 hours.
  5. Perform full operation check and update test record.

REPLACEMENT BATTERY TYPE:

3.2V 1500mAh Li-Ion.

CLEANING:
Disconnect the power and clean the exterior only of this fitting with a moist (not wet) cloth.
Do not use any chemical or abrasive cleaners.

IF YOU EXPERIENCE PROBLEMS:

If you believe your product is defective, please return it to the place where you bought it. Our Technical Team will gladly advise on any Eterna Lighting product, but may not be able to give specific instructions regarding individual installations.

See the website for more information on replaceability and recycling

Email:sales@eterna-lighting.co.uk 
technical@eterna-lighting.co.uk
Visit our website: www.eterna-lighting.co.uk
Issue 0821
Made in China

Documents / Resources

| Eterna BATL5FTEM3 4ft 5ft and 6ft Li-Ion Emergency LED Battens [pdf] Instruction Manual
BATL4FTEM3, BATL5FTEM3, BATL6FTEM3, BATL5FTEM3 4ft 5ft and 6ft Li-Ion Emergency LED Battens, BATL5FTEM3, 4ft 5ft and 6ft Li-Ion Emergency LED Battens, Li-Ion Emergency LED Battens, LED Battens
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>