ETERNA CHA18SD Temperature Selectable Circular LED Ceiling Wall Light Instruction Manual
- June 4, 2024
- Eterna
Table of Contents
ETERNA CHA18SD Temperature Selectable Circular LED Ceiling Wall Light
LED LAMP SPECIFICATIONS
LED LAMP SPECIFICATIONS: | 9W | 14W | 18W |
---|
Luminaire lumens (with diffuser): Warm White, Cool White, Daylight White
| 3000K – 1000 lm
4400K – 1100 lm
6500K – 1100 lm
| 3000K – 1500 lm
4400K – 1670 lm
6500K – 1640 lm
| 3000K – 1880 lm
4400K – 2130 lm
6500K – 2050 lm
Lumens from chip (array): Warm White, Cool White, Daylight White
| 3000K – 1120 lm
4400K – 1220 lm
6500K – 1230 lm
| 3000K – 1680 lm
4400K – 1880 lm
6500K – 1850 lm
| 3000K – 2120 lm
4400K – 2400 lm
6500K – 2320 lm
Useful lumens (array): Warm White, Cool White, Daylight White
| 3000K – 900 lm
4400K – 1000 lm
6500K – 1000 lm
| 3000K – 1350 lm
4400K – 1500 lm
6500K – 1480 lm
| 3000K – 1700 lm
4400K – 1900 lm
6500K – 1860 lm
Rated Wattage| 9W| 14W| 18W
Rated luminous flux
| 3000K – 900 lm
4400K – 1000 lm
6500K – 1000 lm
| 3000K – 1350 lm
4400K – 1500 lm
6500K – 1480 lm
| 3000K – 1700 lm
4400K – 1900 lm
6500K – 1860 lm
Nominal life time of the lamp| 40,000 hrs| 40,000 hrs| 40,000 hrs
Colour temperature| 3000/4400/6500K| 3000/4400/6500K| 3000/4400/6500K
Number of switching cycles before premature lamp failure| ****
15000
| ****
15000
| ****
15000
Warm-up time up to 60% of the full light output| Instant full light| Instant
full light| Instant full light
Dimmable| No| No| No
Nominal beam angle| 120°| 120°| 120°
Rated power| 9W| 14W| 18W
Rated lamp lifetime| 40,000 hrs| 40,000 hrs| 40,000 hrs
Displacement factor| 0.96| 0.96| 0.96
Lumen maintenance factor at end of nominal life| ≥80| ≥80| ≥80
Starting time| Instant full light| Instant full light| Instant full light
Colour rendering| ≥80| ≥80| ≥80
Colour consistency| Within 6 step Macadam ellipse| Within 6 step Macadam
ellipse| Within 6 step Macadam ellipse
Rated peak intensity
| 3000K – 286cd
4400K – 310cd
6500K – 312cd
| 3000K – 432cd
4400K – 484cd
6500K – 746cd
| 3000K – 611cd
4400K – 621cd
6500K – 605cd
Rated beam angle| 120°| 120°| 120°
Voltage / Frequency| 240V~50-60Hz| 240V~50-60Hz| 240V~50-60Hz
Lumen efficacy
| 3000K – 111 lm / W
4400K – 122 lm / W
6500K – 122 lm / W
| 3000K – 107 lm / W
4400K – 119 lm / W
6500K – 117 lm / W
| 3000K – 104 lm / W
4400K – 118 lm / W
6500K – 114 lm / W
This product contains a Light Source of Energy Efficiency Class E
Not suitable for accent lighting
READ THIS FIRST
- Check the pack and make sure you have all of the parts listed on the front of this booklet. If not, contact the outlet where you bought this product.
- This product must be installed by a competent person in accordance with the current building and IEE wiring regulations.
- As the buyer, installer and/or user of this product it is your own responsibility to ensure that this fitting is fit for the purpose for which you have intended it. Eterna
- Lighting cannot accept any liability for loss, damage or premature failure resulting from inappropriate use.
- This product is designed and constructed according to the principles of the appropriate British Standards and is intended for normal domestic service. Using this fitting in any other environment may result in a shortened working life, for example where there is prolonged periods of use or higher than normal ambient temperatures such as lighting public or shared spaces or in nursing /care home facilities.
- Switch off the mains before commencing installation and remove the appropriate circuit fuse or lock off MCB.
- This product is suitable for use in living areas, Bathroom Zone 2 and outsides of zones.
- If being fitted in a bathroom a 30mA RCD must be used.
- This product is designed for permanent connection to fixed wiring: this must be a suitable circuit (protected with the appropriate MCB or fuse).
- This product is suitable for installation on surfaces with normal flammability e.g. wood, plasterboard and masonry.
- It is not suitable for use on highly flammable surfaces (e.g. polystyrene, textiles).
- Before making fixing hole(s), check that there are no obstructions hidden beneath the mounting surface such as pipes or cables.
- The chosen location of your new fitting should allow for the product to be securely mounted (e.g. to a ceiling joist) and safely connected to the mains supply (lighting circuit).
- When making connections ensure that the terminals are tightened securely and that no strands of wire protrude. Check that the terminals are tightened onto the bared conductors and not onto any insulation.
This product is double insulated. Do not connect any part to Earth.
- This product is not intended to be used by children and persons with sensory, physical, and/or mental impairments that would prevent them from using it safely.
- You are advised at every stage of your installation to double-check any electrical connections you have made. After you have completed your installation there are electrical tests that should be carried out, these tests are specified in the current IEE wiring and building regulations.
INTRODUCTION
- The ceiling/wall light incorporates a microwave sensing device that continuously scans the operating zone and immediately switches the light on when it detects movement in that area. This means that whenever motion is detected within the range of the sensor the light will switch on automatically and illuminate the area you have selected to light. While there is a movement within range of the unit the light will remain on.
- A microwave sensor is an active motion detector emitting high-frequency electro-magnetic waves at 5.8GHz and receiving their echo. The sensor detects a change in the echo pattern within its detection zone and the light is then triggered. The wave can pass through doors, glass, and thin walls and will continually monitor the signal within the detection area.
INSTALLATION
Choose the location for your new fitting according to the conditions listed opposite.
- Hold the base of the fitting and gently turn the diffuser and decorative trim anti-clockwise and lift off.
- Loosen screw on LED turnbuckle and rotate to release the tray which will then hinge to allow access to the wiring terminals.
- Drill holes in the back of your fitting for your fixing screws, take care and drill gently to ensure a clean hole through. Use a drill bit sized appropriately to your fixing screws.
- Using the back of your fitting as a template, mark the position of your fixing holes on your mounting surface.
- Prepare the holes in your mounting surface as appropriate for your fixings.
- Pierce the rubber grommet in the back of your fitting making a hole just large enough to make a tight fit around the incoming mains cable.
- Thread the cable through the grommet and offer the fitting to the ceiling/wall.
- Secure the fitting in place. Note, if protection against ingress of moisture is required, the heads of screws must be covered with a silicone or similar sealant.
- Check that the grommet is still correctly fitted in the cable entry hole and around the incoming cable.
- Make the electrical connections to the terminal Make the electrical connections to the terminal
- Set power to the desired option by selecting the appropriate switch setting on the driver: 9W / 14W / 18W options
- Set color temperature to the desired option by selecting the appropriate switch setting on the driver.
DL| Daylight| 6500K
---|---|---
CW| Cool White| 4400K
WW| Warm White| 3000K - Set desired settings on microwave.
- Replace gear tray and secure in position.
- Offer the diffuser and decorative trim onto the top of the fitting and turn clockwise until they are held securely.
- Restore the power and switch on.
UNDERSTANDING THE CONTROLS
REFER TO STEP DIM MICROWAVE SENSOR PICTURE ON FRONT PAGE / BELOW:
The motion detector can turn on the light based on movement. With this detector built in, light is automatically on when needed and dimmed to preset level before it is totally off.
SENSITIVITY / DETECTION RANGE
| 1|
---|---|---
I| ON| 100%
II| OFF| 50%
Sensitivity can be adjusted by selecting the combination on the DIP switches for different applications.
HOLD-TIME
| 2| 3|
---|---|---|---
I| ON| ON| 5sec
II| ON| OFF| 90sec
III| OFF| OFF| 180sec
IV| OFF| ON| 10min
Hold-time refers to the time period that the light remains 100% on if no more movement is detected.
CORRIDOR FUNCTION / STANDBY TIME
| 4|
---|---|---
I| ON| Disable
II| OFF| 10Lux
This is the time period that the light remains at a low level before it is completely turned off.
CORRIDOR DIMMING LEVEL / STAND-BY DIMMING LEVEL
| 5| 6|
---|---|---|---
I| ON| ON| 0Sec
II| ON| OFF| 10Sec
III| OFF| ON| 10Min
IV| OFF| OFF| +
Light can be dimmed to different levels after hold-time.
| 7|
---|---|---
I| ON| 10%
II| OFF| 30%
STEP DIM MW SENSOR SPECIFICATIONS
PRODUCT TYPE | STEP DIM MICROWAVE MOTION SENSOR |
---|---|
Operating Voltage | 220-240VAC 50/60Hz |
HF System | 5.8GHz |
Transmission Power | <0.2mW |
Detection Angle | 150° Max |
Power Consumption | <0.3W |
Detection Range | Max. 6m adjustable |
Dectection sensitivity | 50% / 100% |
Hold time | 5s / 90s /180s / 10 min |
Corridor function | 0s / 10s / 10 min / Disable |
Corridor Dimming Level | 10% / 30% |
Daylight sensor | 10 lux / Disable |
Mounting | Indoors, ceiling and wall |
Light Control | 10lux, disable |
Working Temp | -20 to +60 degree |
Rated Load
| 400W (Inductive load) 800W (Resistive load) 270W (LED)
Eterna Lighting Ltd RED DIRECTIVE – Microwave Occupancy Sensor Full declaration available at: www.eterna-lighting.co.uk/red- declaration
LAMP REPLACEMENT
The light source is designed to last the lifetime of the luminaire.
The light source contained in this luminaire shall only be replaced by the
manufacturer, service agent or a similar qualified person.
CAUTION, RISK OF ELECTRIC SHOCK.
An Earth connection is not required for the operation of these Class II luminaires. The addition of the Earth terminal provides a loop-in/loop out facility which allows connectivity through to other Class I luminaires in the same lighting circuit.
EVENTUALLY, YOU MAY WANT TO REPLACE THIS PRODUCT
-
Regulations require the recycling of Waste from Electrical and Electronic Equipment (European
“WEEE Directive” effective August 2005—UK WEEE Regulations effective 2nd January 2007). Environment Agency Registered Producer: WEE/GA0248QZ. -
WHEN YOUR PRODUCT COMES TO THE END OF ITS LIFE OR YOU CHOOSE TO REPLACE IT, PLEASE RECYCLE IT WHERE FACILITIES EXIST – DO NOT DISPOSE WITH HOUSEHOLD WASTE
CLEANING
Clean this fitting only with a soft dry cloth. Do not use any chemical or abrasive cleaners.
IF YOU EXPERIENCE PROBLEMS
If you believe your product is defective, please return it to the place where you bought it. Our Technical Team will gladly advise on any Eterna Lighting product, but may not be able to give specific instructions regarding individual installations.
See the website for more information on replacability and recycling
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>