FORTIN Hyundai XG350 Remote Starters and Alarm Systems Installation Guide
- June 13, 2024
- FORTIN
Table of Contents
Hyundai XG350 Remote Starters and Alarm Systems
Product Information:
Product Name: Immobilizer Bypass T-Harness
Model: THAR-ONE-KHY1
Compatible Vehicles: Hyundai XG300, XG350 (2001-2005)
Firmware Version: 76.[60]
Required Parts (Not included):
- 2x Relay
- 2x Fuse
Mandatory Installations:
-
Hood Pin Switch: The hood pin switch must be installed if the
vehicle can be remote started with the hood open. -
Security Sticker: This module must be installed by a qualified
technician to avoid permanent damage to the vehicle.
Product Usage Instructions:
To add the firmware version and options, use the FLASH LINK
UPDATER or FLASH LINK MOBILE tool, sold separately.
Program Remote Starter Option:
- Function: 20
- Mode: 2
Wiring Connections:
Description | Connection | Wire Color | Location |
---|---|---|---|
(+) Ignition | Yellow In | AA11 | |
(-) Lock | Purple Out | AA22 | |
(-) Unlock | Purple/White Out | AA33 | |
Parking Lights | Pink Out | AA1122 | |
Trunk Release | Yellow/Black Out | AA1133 | |
Hood Pin | Pink/Black In | AA1155 | |
Accessory | Red In | EE33 | |
Starter | Yellow In | EE44 | |
Foot Brake | Black In | AA1111 | |
Ground | Black In | EE66 | |
PATS DATA | Lt.Blue/Black In/Out | AA1100 | |
Security Light | White/Black Out | AA1199 |
Note: Cut the loop for automatic transmission mode.
For detailed wiring connections, please refer to the user
manual’s page 2 and 3.
Immobilizer bypass Contournement d’immobilisateur T-Harness Harnais en T Lock Unlock Arm Disarm Parking Light Trunk (open) Door Status Trunk Status
ONE Page 1 / 6
REV.: 20211021
REGULAR INSTALLATION AND THAR-ONE-KHY1 INSTALLATION INSTALLATION RÉGULIÈRE ET INSTALLATION THAR-ONE-KHY1
Guide # 95901
ADDENDUM – SUGGESTED WIRING CONFIGURATION ADDENDA – SCHÉMA DE BRANCHEMENT
SUGGÉRÉ
Vehicle functions supported in this diagram (functional if equipped) | Fonctions du véhicule supportées dans ce diagramme (fonctionnelles si équipé)
VEHICLE VEHICULES HYUNDAI XG300 XG350
YEARS ANNÉES
2001 2002-2005
·
·
········
·
·
········
BYPASS FIRMWARE VERSION VERSION LOGICIELLE CONTOURNEMENT
76.[60] MINIMUM
To add the firmware version and the options, use the FLASH LINK UPDATER or
FLASH LINK MOBILE tool,
sold separately.
Pour ajouter la version logicielle et les options, utilisez l’outil FLASH LINK
UPDATER
ou FLASH LINK MOBILE, vendu séparément.
Program remote starter option:
Programmez l’option démarreur à distance:
FUNCTION FONCTION
20
MODE
2
DESCRIPTION
Tachless only. ( vehicles with automatic transmission only) Sans Tachymètre
seulement. (véhicules à transmission automatique seulement)
Parts required (Not included)
Pièce(s) requise(s) (Non incluse(s))
WIRE TO WIRE DIAGRAM | SCHÉMA DE BRANCHEMENTS FIL À FIL
PAGE
AUTOMATIC TRANSMISSION TRANSMISSION AUTOMATIQUE
2x Relay
2x Relais
Page 2
THARNESS DIAGRAM | SCHÉMA DE BRANCHEMENTS HARNAIS EN T
THARNESS THAR-ONEKHY1
AUTOMATIC TRANSMISSION TRANSMISSION AUTOMATIQUE
1x THAR-ONE-KHY1 2x Relay 2x Fuse
1x THAR-ONE-KHY1 2x Relais 2x Fusible
Page3
MANDATORY INSTALL | INSTALLATION OBLIGATOIRE
- HOOD PIN
HOOD STATUS : THE HOOD PIN SWITCH (INCLUDED) MUST BE INSTALLED IF THE VEHICLE CAN BE REMOTE STARTED WITH THE HOOD OPEN.
CONTACT DE CAPOT
STATUT DE CAPOT : LE CONTACT DE CAPOT (INCLUS), DOIT ÊTRE INSTALLÉ SI LE VÉHICULE PEUT DÉMARRER À DISTANCE, LORSQUE LE CAPOT EST OUVERT.
SECURITY STICKER
AUTOCOLLANT DE SÉCURITÉ
WARNING ATTENTION
Included Inclus
Notice: the installation of safety elements are mandatory. The hood pin and the sticker are essential security elements and must be installed. Notice: l’installation des éléments de sécurité est obligatoire. Le contact de capot et l’autocollant de sécurité sont des éléments de sécurité essentiels et doivent absolument être installés.
THIS MODULE MUST BE INSTALLED BY A QUALIFIED TECHNICIAN. A WRONG
CONNECTION CAN CAUSE PERMANENT DAMAGE TO THE VEHICLE.
CE MODULE DOIT ÊTRE INSTALLÉ PAR UN TECHNICIEN QUALIFIÉ, TOUTE
ERREUR DANS LES BRANCHEMENTS PEUT OCCASIONNER DES DOMMAGES
PERMANENTS AU VÉHICULE.
This guide may change without notice. See www.fortin.ca for latest version. Ce
guide peut faire l’objet de changement sans préavis. Voir www.fortin.ca pour
la récente version.
WIRING CONNECTION | GUIDE DE BRANCHEMENTS
Page 2 / 6
HOOD PIN MANDATORY CONTACT CAPOT OBLIGATOIRE
(+)Ignition
Yellow In AA11
(-)Lock
Purple Out AA22
(-)Unlock Purple/White Out AA33
Green Out AA44
White Out AA55
(-)Disarm
Orange Out AA66
Orange/Black Out AA77
Dk.Blue Out AA88
Red/Blue In AA99
(~) PATS DATA Lt.Blue/Black In/Out AA1100
(+)Foot Brake
Black In AA1111
(-)Parking Lights
Pink Out AA1122
(-)Trunk Release Yellow/Black Out AA1133
Brown/White In AA1144
(-)Hood Pink/Black In AA1155
Purple/Yellow In/Out AA1166
Green/White In/Out AA1177
Green/Red In/Out AA1188
White/Black Out AA1199
Lt.Blue In/Out AA2200
(+)Accessory
(+)12V
(-)Ground (+)Ignition (+)Starter
White Out EE11 Orange Out EE22
Red In EE33 Black In EE44 Pink In/Out EE55 Yellow Out EE66
CUT LOOP FOR AUTOMATIC TRANSMISSION MODE. COUPEZ LA BOUCLE POUR LE MODE TRANSMISSION AUTOMATIQUE.
C5 Brown C4 Gray/Black C3 Gray C2 Orange/Brown C1 Orange/Green
DD66 White/Red D5 White/Blue D4 White/Green D3 Yellow/Red D2 Yellow/Blue D1 Yellow/Green
(-)Security Light (-)Security Light
Ground Masse
XG300 XG350
CUT CUT CUT
A3
87
85
86 87a
30
87
85
86 87a 30
30
A2
87
85
86 87a 30
30
87 87a 85
86 30
D4
Fuse Fusible
A11 (+)FOOT BRAKE
Blue Bleu
A13 (-)TRUNK RELEASE
Blue Bleu
A6 (-)DISARM
Lt. Green Vert Pâle
87a 87
85
86 87a
30
(REVERSE) UNLOCK
Tan Beige
87a 87
85
86 87a
30
(REVERSE) LOCK
Gray Gris
A10 (~)PATS DATA
Green Vert
D6
(-)SECURITY LIGHT
A12
(-)PARKING LIGHT
Brown/White Lt. Blue Brun/Blanc Bleu Pâle
E3 (+)12 V
Red Rouge
E5/A1 (+) IGNITION
Pink Rose
E2 (+) ACCESSORY
Orange Orange
E6 (+)STARTER
Yellow Jaune
12
34
5 6 7 8 9 10
10
9
8
7
6
5
4
3
2
1
20 19 18 17 16 15 14 13 12 11
At Brake switch
Au Commutateur de frein
At Driver’s kick panel
Au Panneau latéral côté conducteur
At Driver’s door panel
Au Panneau de la portiêre
côté conducteur
Back view White 10-pin
connector Next to OBDII
connector Vue de dos Connecteur Blanc de 10-pins À côté du connecteur
d’OBDII
Back view White 20-pin
connector Left of the steering column Vue de dos Connecteur Blanc de 20-pins À
gauche de la colonne de direction
At Parking light switch
Au Commutateur des feux de stationne-
ment
At ignition switch
Au commutateur d’Ignition
This guide may change without notice. See www.fortin.ca for latest version. Ce
guide peut faire l’objet de changement sans préavis. Voir www.fortin.ca pour
la récente version.
THAR-ONE-KHY1 | WIRING CONNECTION | GUIDE DE BRANCHEMENTS
Page 3 / 6
HOOD PIN MANDATORY CONTACT CAPOT OBLIGATOIRE
(+)Ignition
Yellow In AA11
(-)Lock
Purple Out AA22
(-)Unlock Purple/White Out AA33
Green Out AA44
White Out AA55
(-)Disarm
Orange Out AA66
Orange/Black Out AA77
Dk.Blue Out AA88
Red/Blue In AA99
(~) PATS DATA Lt.Blue/Black In/Out AA1100
(+)Foot Brake
Black In AA1111
(-)Parking Lights
Pink Out AA1122
(-)Trunk Release Yellow/Black Out AA1133
Brown/White In AA1144
(-)Hood Pink/Black In AA1155
Purple/Yellow In/Out AA1166
Green/White In/Out AA1177
Green/Red In/Out AA1188
White/Black Out AA1199
Lt.Blue In/Out AA2200
(-)Ground (+)Ignition
White Out EE11 Orange Out EE22
Red In EE33 Black In EE44 Pink In/Out EE55 Yellow Out EE66
CUT LOOP FOR AUTOMATIC TRANSMISSION MODE. COUPEZ LA BOUCLE POUR LE MODE TRANSMISSION AUTOMATIQUE.
C5 Brown C4 Gray/Black C3 Gray C2 Orange/Brown C1 Orange/Green
DD66 White/Red D5 White/Blue D4 White/Green D3 Yellow/Red D2 Yellow/Blue D1 Yellow/Green
(-)Security Light (-)Security Light
GMraosusned
T-HARNESS – HARNAIS EN T
THAR-ONE-KHY1
XG300 XG350
CUT CUT CUT T-HARNESS – HARNAIS EN T
MALE T-HARNESS IGNITION PLUG CONNECTEUR D’IGNITION MÂLE DU T-HARNAIS
FEMALE T-HARNESS IGNITION PLUG CONNECTEUR D’IGNITION FEMELLE DU T-HARNAIS MALE
VEHICLE IGNITION PLUG CONNECTEUR MÂLE D’IGNITION DU VÉHICULE
A3
87
85
86 87a
30
A2
(+)12V
87
85
86 87a 30
30
87
85
86 87a 30
30
87 87a 85
86 30
(+)12V
D4
A11 (+)FOOT BRAKE
Blue Bleu
A13 (-)TRUNK RELEASE
Blue Bleu
A6 (-)DISARM
Lt. Green Vert Pâle
87a 87
85
86 87a
30
(REVERSE) UNLOCK
Tan Beige
87a 87
85
86 87a
30
(REVERSE) LOCK
Gray Gris
A10 (~)PATS DATA
Green Vert
D6
(-)SECURITY LIGHT
A12
(-)PARKING LIGHT
Brown/White Lt. Blue Brun/Blanc Bleu Pâle
12
34
5 6 7 8 9 10
10
9
8
7
6
5
4
3
2
1
20 19 18 17 16 15 14 13 12 11
At Brake switch
Au Commutateur de frein
At Driver’s kick panel
Au Panneau latéral côté conducteur
At Driver’s door panel
Au Panneau de la portiêre
côté conducteur
Back view White 10-pin
connector Next to OBDII
connector Vue de dos Connecteur Blanc de 10-pins À côté du connecteur
d’OBDII
Back view White 20-pin
connector Left of the steering column Vue de dos Connecteur Blanc de 20-pins À
gauche de la colonne de direction
At Parking light switch
Au Commutateur des feux de stationne-
ment
At ignition switch
Au commutateur d’Ignition
This guide may change without notice. See www.fortin.ca for latest version. Ce guide peut faire l’objet de changement sans préavis. Voir www.fortin.ca pour la récente version.
Page 4 / 6
KEY BYPASS PROGRAMMING PROCEDURE | PROCÉDURE DE PROGRAMMATION CONTOURNEMENT DE CLÉ
1
x1
HOLD
2
RELEASE
G F A E
J H B C D
I
Press and hold the programming button: Connect the 6-PIN Main harness (White
connector).
The LEDs will alternate between BLUE, YELLOW, RED and BLUE & RED flashes.
Appuyez et maintenir le bouton de programmation enfoncé: Branchez le harnais
Principal à 6-Pins (connecteur Blanc).
Les DELs alterneront entre un flash BLEU, JAUNE, ROUGE, et BLEU et ROUGE.
Release the programming button when the RED LED is ON.
Relâchez le bouton de programmation quand la DEL ROUGE est allumée.
H B C D
J
I
H B C D
I
J
G F
A E
E
G F A
ON
RED ROUGE
If the RED LED is not ON solid disconnect the 6 Pin Main connector and go back to step 1.
Si la DEL ROUGE n’est pas allumée, débranchez le connecteur Principal à 6-broches et retournez à l’étape 1.
3
J H B C D
I
Insert the required remaining connectors.
Insérez les connecteurs requis restants.
I
J H B C D
J H B C D
J H B C D
G F A E
I
G F A E
G F A E
G F
A E
I I I
4
x3
PRESS
5
TURN ON/RUN
6
TURN OFF
LOCK
LOCK
G F A E
J H B C D
I
PRESS X3
FLASH X2
ON
Press and release the programming button 3 times (3x).
…
The RED LED will flash
twice and pause.
Appuyez et relâchez 3 fois le bouton de programmation.
La DEL ROUGE clignote 2 fois et pause.
ACC ON
IGN
START
PUSH
OFF
ACC ON PUSH
START
G J
F
G
J
F
A
A
H
H
B
E
C
B C E D
D
IGNITION ON FLASH 10X
FLASH 10X
OFF
Turn the key to the Ignition ON/RUN position.
The Red LED will flash 10 times rapidly. The key bypass is programmed.
Tournez la clé à Ignition.
La DEL Rouge clignotera 10 fois rapidement. Le contournement de la clé est
programmé.
IGNITION OFF
OFF
Turn the key to the OFF position.
The LEDs will turn off.
Tournez la clé à la position Arrêt (OFF).
Les DELs s’éteindront.
The module is now programmed.
Le module est programmé.
This guide may change without notice. See www.fortin.ca for latest version. Ce guide peut faire l’objet de changement sans préavis. Voir www.fortin.ca pour la récente version.
Page 5 / 6
REMOTE STARTER PROGRAMMING PROCEDURE | PROCÉDURE DE PROGRAMMATION DU DÉMARREUR À DISTANCE
REFER TO THE QUICK INSTALL GUIDE INCLUDED WITH THE MODULE FOR THE REMOTE
STARTER PROGRAMMING.
RÉFÉREZ-VOUS AU GUIDE D’INSTALLATION RAPIDE INCLUS AVEC LE MODULE POUR LA
PROGRAMMATION DU DÉMARREUR À DISTANCE.
REMOTE STARTER FUNCTIONALITY | FONCTIONNALITÉS DU DÉMARREUR À DISTANCE
Start
UNLOCK
TURN ON/RUN
ON
All doors must be closed. Toutes les
portes doivent être fermées.
Remote start the vehicle.
Démarrez à distance.
Unlock the doors with the remote-starter remote or the OEM remote.
Déverrouillez les portes avec la télécomande du démarreur à distance ou
la télécommande d’origine.
Insert and Turn the key to the Ignition ON/RUN
position. Insérez et tournez la clé à la position “ON/RUN”.
Press the brake pedal.
Appuyez sur la pédale de
frein.
The vehicle can now be put in to gear and driven.
Vous êtes maintenant prêt à
embrayer et prendre la route.
Page 6 / 6
ONE
HARDWARE VERSION FIRMWARE VERSION
Date: xx-xx
INTERFACE MODULE
PATENTS PENDING US: 2007-228827-A1
Made in Canada www.fortinbypass.com
Service No : 000 102 04 2536
Module label | Étiquette sur le module
Notice: Updated Firmware and Installation Guides Updated firmware and
installation guides are posted on our web site on a regular basis. We
recommend that you update this module to the latest firmware and download the
latest installation guide(s) prior to the installation of this product.
Notice: Mise à jour microprogramme et Guides d’installations Des mises à jour
du Firmware (microprogramme) et des guides d’installation sont mis en ligne
régulièrement. Vérifiez que vous avez bien la dernière version logiciel et le
dernier guide d’installation avant l’installation de ce produit.
WARNING The information on this sheet is provided on an (as is) basis with no
representation or warranty of accuracy whatsoever. It is the sole
responsibility of the installer to check and verify any circuit before
connecting to it. Only a computer safe logic probe or digital multimeter
should be used. FORTIN ELECTRONIC SYSTEMS assumes absolutely no liability or
responsibility whatsoever pertaining to the accuracy or currency of the
information supplied. The installation in every case is the sole
responsibility of the installer performing the work and FORTIN ELECTRONIC
SYSTEMS assumes no liability or responsibility whatsoever resulting from any
type of installation, whether performed properly, improperly or any other way.
Neither the manufacturer or distributor of this module is responsible of
damages of any kind indirectly or directly caused by this module, except for
the replacement of this module in case of manufacturing defects. This module
must be installed by qualified technician. The information supplied is a guide
only. This instruction guide may change without notice. Visit
www.fortinbypass.com to get the latest version.
MISE EN GARDE L’information de ce guide est fournie sur la base de
représentation (telle quelle) sans aucune garantie de précision et
d’exactitude. Il est de la seule responsabilité de l’installateur de vérifier
tous les fils et circuits avant d’effectuer les connexions. Seuls une sonde
logique ou un multimètre digital doivent être utilisés. FORTIN SYSTÈMES
ÉLECTRONIQUES n’assume aucune responsabilité de l’exactitude de l’information
fournie. L’installation (dans chaque cas) est la responsabilité de
l’installateur effectuant le travail. FORTIN SYSTÈMES ÉLECTRONIQUES n’assume
aucune responsabilité suite à l’installation, que celle-ci soit bonne,
mauvaise ou de n’importe autre type. Ni le manufacturier, ni le distributeur
ne se considèrent responsables des dommages causés ou ayant pu être causés,
indirectement ou directement, par ce module, excepté le remplacement de ce
module en cas de défectuosité de fabrication. Ce module doit être installé par
un technicien qualifié. L’information fournie dans ce guide est une
suggestion. Ce guide d’instruction peut faire l’objet de changement sans
préavis. Consultez le www.fortinbypass.com pour voir la plus récente version.
Copyright © 2006-2018, FORTIN AUTO RADIO INC ALL RIGHTS RESERVED PATENT
PENDING
TECH SUPPORT Tél: 514-255-HELP (4357)
1-877-336-7797
ADDENDUM GUIDE
www.fortinbypass.com
WEB UPDATE | MISE À JOUR INTERNET
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>