Teinnova QR Ozoair Intelligent Ozone Generator Instruction Manual

June 13, 2024
TEiNNOVA

Teinnova QR Ozoair Intelligent Ozone Generator Instruction Manual
Teinnova QR Ozoair Intelligent Ozone Generator

introduction

Dear Client:

Thank you for placing your trust in a quality product from TEINNOVA. This product has been made using modern manufacturing techniques and thorough quality assurance measures.

We do everything possible to ensure that you are satisfied with this product and can operate it without any issues. Should you have any questions about this product, please contact your dealer or contact the company directly. Before starting up the machine, carefully read the instructions for use of your equipment.

Treat this manual as part of the machine and always keep it nearby for future reference

Training service

We offer the option of providing companies with training specific to our products as well as teaching their operators how to provide the best service and thus contribute to the success of their end customers. Aspects such as knowing how to prepare a fair and objective quote, to respond to specific problems that may arise, or to offer a more professional and efficient service.

Technical service

Because we manufacture our own cleaning equipment we can control at all times the quality and performance of every machine we manufacture, and this is what has allowed us to maintain low-cost service rates which have always been resolved by our own Technical Support Service who are managed by the same team as our factory, and in a short space of time.

We have all kinds of spare parts for your equipment, as well as related accessories

symbols used

All the symbols used in this manual, as well as those on the equipment, are explained in this section. It is important to read the text associated with these symbols carefully, since it is about personal safety and equipment safety

DANGER
This symbol warns you of a potentially dangerous situation that could result in serious injuries or death if instructions are not be properly followed. Make sure you read all the instructions in the “Safety information” section.

WARNING
This symbol warns you of a potentially dangerous situation that could result in minor or moderate injuries, or property damage resulting in injury to people if instructions are not properly followed.

ATTENTION!
This symbol warns you of a situation that may cause damage to property, without causing injury, if the instructions given are not followed properly.

IMPORTANT
This symbol alerts you to information about the best way to use the equipment avoiding any possible improper operation.

know your equipment

What is ozone?
OZONE is the molecule of three oxygen atoms, whose chemical formula is O3. OZONE’s germicidal activity is based on its high capacity for direct oxidation: thanks to this quality, all the macromolecular structures of the cells, microbial and [mould, bacteria, yeast, virus, etc.] are deeply altered, decompose and disappear, leaving no residue: only oxygen.

In conclusion, rapid, complete and residue-free germicidal action.

How Is It Produced?

Molecule of Oxygen (O2)

Energy divisions

Ozone forms (O3)

Dissociation atoms of oxygen and ozone

Ozone becomes oxygen

Applications
This OZO3 portable ozone generator has been designed to perform spot shock disinfection in environments and on surfaces, with the aim of disinfecting, deodorizing and purifying the air, surfaces, furniture, carpets etc. Suitable for treating spaces in healthcare, hospitality, shops, houses and vehicles of all kinds.

Ozone as a biocide

We suggest using it to sanitise workspaces that might be used by people, eliminating any microorganisms that may be present in the air and on surfaces.Although there are no conclusive studies nor an accurate description of the effect of ozone on the SARS-CoV-2 virus, there is a broad consensus on the effectiveness of its use in ensuring the agent is not present. Many studies carried out on similar microorganisms support this action for certain lengths of time and for certain air ozone concentrations.

Ozone, as an active biocidal substance generated in-situ, is under evaluation bythe European Union and is not yet included in the list of biocides, but its use as disinfectant is not banned, accordingly, the Ministry of Health’s only requirement are notification by the manufacturer, training in its use and the safety measures to apply

know your equipment

DESCRIPTION AND CONTENT

OZOAIR is a mobile, easy to use device for the disinfection of the air and indoor surfaces. The robust system is controlled automatically and is characterised by its high safety levels. The equipment incorporates unique system which consists of a two stage cycle that is capable of generating ozone and then eliminating it, enabling the immediate use of treated interior space.

In the first stage, an ozone-enriched atmosphere is generated from the air itself. The technology in your OZOAIR enables the production of ozone in homogeneous conditions and in a high concentration within a short period of time.

In the second stage, residual ozone produced during treatment is decomposed in oxygen in order to reach regulated levels of habitability with the aim of being able to occupy the treated interior space immediately after ozonising the space

PARTS AND CONTENT OF THE EQUIPMENT

Parts Content
Parts Content

TOUCH CONTROL SCREEN

Control functions:

  • Automatic programs according to m3 of areas.
  • Manual fit at time of use.
  • Timer with adjustable date and time.
  • Indicator of filter lifespan.
  • Activation time delay

Never use the ozone generator when humans or pets are in the ozonised vicinity, as they may be exposed to a high ozone concentration which can be damaging to health. Ensure that all ozone is converted back into oxygen before entering a space. This process of ozone decomposition lasts approximately 30 minutes. It is convenient to ventilate the area by opening doors and windows in the ozonised area.

safety warning

  • Never use the ozone generator when humans or pets are in the space treated with ozone, as they may be exposed to a high ozone concentration.
  • Do not use the equipment in environments with a high relative humidity >90%, neither is allowed outdoors.
  • Do not block the air inlet, nor the ozone outlet, leave these spaces free so that block the flow of air necessary for the ozonization process.
  • The equipment is supplied with a grounding cable, always connect it to sockets with to prevent electrical shunts from the equipment.
  • Before activating, ensure that the there are no objects in the treated area that contain rubber because exposure to ozone can degrade it.
  • Do not use the equipment in hazardous, potentially explosive environments, or in the presence of flammable gases and vapours. Use the Equipment on a flat and smooth surface.

Personal Protective Equipment

The best prevention is not to enter the ozone treated spaces until the safety time shown in the table of ozone treatment and decay times has passed. In the event of the ozone treated areasneeding top be accessed, the Personal Protection Equipment listed below should be used:

Ozone gas detector and meter [03] Personal Protective

Sign warning of danger, to be placed on the access doors to the ozone treated area.
Sign Warning

OZONE ICSC: 0068 Aprill 2009

CAS:              10028-15-6       O 3 RTECS: RS8225000 Molecular mass: 48.0 CE / EINECS: 233-069-2Symbols
FIRE AND EXPLOSION| ACUTE DANGERS / SYMPTOMS| PREVENTION| FIRST AID / FIRE FIGHTING
FIRE| Non-combustible but facilitates the combustion of others substances. Many reactions can lead to fire or explosion. Risk of fire and explosionin contact with combustible substances.| Avoid flames, DO NOTproduce sparks and DO NOT smoke.NO put in contact with combustible substances. Closed system, ventilation, electrical and explosion-proof lighting.| In case of fire in the environment: use a suitable extinguishing agent. Fight the fire from a protected place.
EXPLOSION| Risk of fire and explosion in contact with combustible substances| Closed system, ventilation, explosion-proof electrical and lighting equipmen.t| Fighting the fire from a protected location
EXPOSURE| | STRICT HYGIENE!|
Inhalation| Sore throat. Cough. headache wheezing Difficulty breathing| Use ventilation, localised extraction or protection Respiratory| Clean air, rest. Semi-integrated position. Provide medical assistance.
Skin| IN CONTACT WITH LIQUID: FREEZING.| Cold insulating gloves.| IF FREEZING: rinse with plentyof water, DO NOT remove clothing. Provide medical assistance.
Eyes| Redness. Pain.| Use face shield or eye protection on combination with respiratory protection.| Rinse with plenty of water for several minutes (remove contact lenses if easily done), then provide medical assistance
Ingestion| | |
SPILLS AND LEAKS| PACKAGING AND LABELLING
Evacuate the danger zone! Consult an expert. Ventilate. Chemical protection suit, including self contained breathing apparatus| According to UN GHS criteria DangerMay cause or aggravate fire; oxidizer. Fatal if inhaled.Causes eye irritationCauses lung damage if inhaledCauses lung damage after prolonged or repeated exposure if inhaled
EMERGENCY RESPONSE| STORAGE
| Fireproof, if it’s indoors. Separated from all substances. Fresh. Keep cool
Prepared in the Context of Cooperation between the IPCS and the European Commission © CE, IPCS, 2009 IPCS InternationalProgramme on Chemical Safety Symbols

IMPORTANT DETAILS

PHYSICAL CONDITION; APPEARANCE
Colourless or blue gas with a characteristic odour.
PHYSICAL HAZARDS
Gas is denser than air.
CHEMICAL HAZARDS
The substance is irritating to the eyes and respiratory tract.
Substance may affect the central nervous system. This can lead
to alterations in attention and performance. Inhalation of the gas
may cause pulmonary oedema. See Notes. Effects may not be
immediate. Liquid may cause frostbite.

EXPOSURE LIMITS

  • TLV: (light duty): 0.1 ppm as TWA; (moderate duty): 0.08 ppm as
  • TWA; (heavy duty): 0.05 ppm as TWA
  • TLV: (less than 2 hours work): 0.2 ppm as TWA.
  • TLV: A4 (not classified as a human carcinogen)
  • MAK: carcinogenic: category 3B

EXPOSURE LINES
La sustancia se puede absorber por inhalación.

INHALATION RISK
When a gas leak occurs, a harmful concentration of gas in the air will be reached very quickly.

EFFECTS OF SHORT-TERM EXPOSURE
The substance irritates the eyes and respiratory tract. The substance can affect the central nervous system, leading to functional disturbances.

Gas inhalation at a concentration above 5 ppm, can cause pulmonary oedema (see Notes). The effects may be delayed. The liquid can cause frostbite.

EFFECTS OF LONG-TERM OR REPEATED EXPOSURE
The lungs can be affected by prolonged or repeated exposure to the gas

PHYSICAL FEATURES

  • Boiling point: -112°C
  • Melting point: -193°C
  • Solubility in water: none
  • Relative vapour density (air = 1): 1.6

ENVIRONMENTAL DATA
This substance can be hazardous to the environment; special attention should be paid to plants.

NOTES
The immediate administration of a suitable aerosol by a doctor or person authorised by them should be considered. This sheet was partially updated in April 2010: see Fire Fighting and GHS Classification.

ADDITIONAL INFORMATION

Occupational exposure limits (INSHT 2011):

  • VLA-ED (heavy duty): 0.05 ppm; 0.1 mg/m³
  • VLA-ED (moderate work): 0.08 ppm; 0.16 mg/m³
  • VLA-ED (light duty): 0.1 ppm; 0.2 mg/m³
  • VLA-ED (heavy, moderate or light work, for 2 hours or less): 0.2 ppm; 0.4 mg/m3

LEGAL NOTE
This file contains the collective opinion of the International Committee of Experts of the IPCS and is independent of any legal requirements. Its possible use is not the responsibility of the EC, the IPCS, their representatives or the INSHT, the author of the Spanish version

© IPCS, CE 2009

operating instructions

How to use

Before use:

It must be taken into account that ozone does not clean, it only disinfects, therefore the room must be cleaned with the usual cleaners before doing the ozone treatment.

Place the equipment in the centre of the area to be ozonised, verifying that both the air inlet and ozone outlet remain unobstructed. Connect the equipment to a grounded power supply.

Measure the area you wish to ozonise in cubic metres, in order to calculate the time needed to generate a sufficient amount of ozone and program the equipment.
How to Use

Applications

Interior spaces in hospitals, clinics, offices, air conditioning ducts

Air conditioning and extraction ducts.

Vehicles of all kinds.

CONTROL SCREEN

Control Screen

Programming the equipment:
Connect the equipment to an electrical source and select the program you wish to use on the control screen, depending on the size of the area to be ozonised (in cubic metres). When activated, the ozonising cycle of the equipment has a 60 second delay before starting, so that the area can be cleared and access blocked.

During use:
People, animals and plants should not remain in the area, keep windows and doors closed and place a warning sign at the entrances, stating that the area is being treated with ozone and DO NOT ENTER.

When the ozone generation cycle and the recycling of ozone into oxygen ends, the illuminated signturns off, from that moment you can access the area and ventilate it by opening windows and doors

CONTROL ACCESS FOR USER

Control Access

NOTE: User ID and password are automatically shown on the screen

MAIN MENU

CONTROL MODE SELECTION
Operating Instructions

SETTINGS
Operating Instructions

PROGRAMMING CALENDAR STATUS STATUS OF FILTER LIFESPAN
Operating Instructions

ADJUSTING TIME, DAY, MONTH AND YEAR
Operating Instructions

NOTE: The date and time that you save will be updated even when the equipment is not connected to the mains.

PROGRAM SELECTION
Operating Instructions

ACTIVATION AND PROGRAM INFORMATION
Operating Instructions

PERSONALISATION
Personalization

PROGRAM SETTINGS WITH CALENDAR

Program Settings

TABLE OF USAGE TIMES BY AREA VOLUME

OZONE PER AREA
| MINUTES GENERATION OF OZONE
| MINUTES ELIMINATION OF OZONE
| TOTAL TIME
| PROGRAM TO USE

---|---|---|---|---
40 – 80 m3| 5| 15| 20 min| XS
80 – 150 m3| 10| 20| 30 min| S
150 – 250 m3| 15| 25| 40 min| M
250 – 500 m3| 30| 30| 60 min| L
500 – 1000 m3| 60| 50| 110 min| XL
1000 – 1500 m3| 90| 60| 150 min| Manual

Place the ozoniser in the middle of the area to be treated, dividing into closed and unobstructed areas.

DUCT DISINFECTION AIR-CONDITIONING

Connect the sleeve to the ozone outlet, then insert the other end on the inside of the duct.
Connect Sleeve

troubleshooting guide

problem solution
The equipment does not work having turned on the switch Check to see if the

power cord is not damage. Check the power input fuse.
The flow rate at which ozonised air is being produced is low| Clean the air inlet filter
The equipment does not generate, or generates very little ozone| Please contact our Technical Support Service

If the time of use of the equipment is exceeded, the warranty will not cover the damage caused.

The ceramic ozone plate can be operated continuously for a maximum period of 90 minutes.

Rest time of the equipment between uses for the plate to cool down is 1 hour.

TECHNICAL FEATURES

Power supply 220 V / 50Hz 110 v /60Hz
Ozone production 15 g/h
Ozone discharge flow rate 500 m3/h
Power 160 W
Power consumption 0,9 A 1,8 A
Control panel 7” HMI Touch screen
Construction material Painted steel and PEHD
Filter to deactivate O3 Photocatalytic
Retention filter for particles G4 Type
Noise level in ozone generation cycle 66 dB
Noise level in ozone decomposition cycle 64 dB
Acoustic warning of begin- ning and end of cycle 85 dB (2-3sec)
Dimensions (L x W x H) 420 x 395 x 880 mm16.5 x 15.5 x 34.6 inch
Weight 31 kg / 68 lb

Dimensions

saturation and decomposition curves

Saturation curve: The graphical representation of the increase in ozone concentration in ug/m3 as a function of time.
Saturation and Decomposition

Decomposition curve: The graphical representation of the decrease in ozone concentration in ug/m3 as a function of time
Decomposition Curve

maintenance and care

  • The device comes with a filter found within the air inlet (see p. 20) please check its condition frequently, clean it and replace it if necessary.
  • The equipment is equipped with a photocatalytic filter for the decomposition of the ozone for its conversion to oxygen, this filter must be replaced when the control screen of the equipment indicates [ver la pág. 20].
  • Keep the grilles found on the air inlet and ozone outlet clean, they can disassembled without tools if necessary and can be washed with water and neutral detergent.
  • The ozone generator has a ceramic crown that generates the electrical charge in the air. This technology has an approximate duration of 15,000 hours; when a replacement is required you should contact TEINNOVA’s  technical support service.

Repuestos:
TEINNOVA has spares for all the equipment parts.
If you need any part or consumable, please contact TEINNOVA Customer Service on +34 941 44 50 56.

PROCEDURE TO REPLACE FILTERS
The equipment uses two filters: 1 retention filter for particles in the air inlet, should be checked every 3 months, cleaned and replaced if necessary. 1 photocatalytic filter for ozone decomposition and conversion into oxygen, should be replaced every 300 hours. A timer recording time available can be viewed on the control panel (see page 12 ).

Disconnect your OZOAIR from the electricity supply before starting any maintenance tasks
Product Overawe
Product Overawe

Keep the grilles found on the air inlet and ozone outlet clean, they can disassembled without tools if necessary and can be washed with water and neutral detergent.

waste management

Symbols
The materials used in the packaging are recyclable. Do not dispose of the packaging in household waste, but hand it in at official collection points for recycling.

Do not dispose of electrical equipment in the trash! We recommend that electrical tools and accessories are subjected to an environmentally friendly recovery process. Please dispose of the materials in the appropriate container or go to your local collection point.

accessories and consumables

CONSUMABLES

PHOTOCATALYTIC FILTER
Deactivates the ozone and converts it into oxygen lasts 300 hours.
PHOTOCATALYTIC FILTER

NOZZLE HOSE
Connects to the ozone outlet in order to supply the pipes.
NOZZLE HOSE

ACCESSORIES

Warning plate that the zone is in the process of ozonization.

To be placed on the handles of the access doors to the zone.

guarantee conditions

“TEINNOVA” guarantees its products for a period of 15 days as regards aesthetic defects or faults which are noticeable with the naked eye. In terms of all other manufacturing defects and faults in the products, the guarantee is of 1 year.

The “Buyer” must report the discovery of any defect as soon as they become aware of it and, in any case, within the maximum period of 5 days from when it becomes apparent. Notification thereof outside of said deadline shall lead to the non-application of the guarantee. “TEINNOVA” will collect and send the products to the factory or to the nearest official Technical Assistance Service for their obligatory inspection. At this point, it will be determined whether the guarantee can be applied or whether it falls under the guarantee exclusions. If the guarantee is applicable, the transport fees, both those for collecting the product from the client’s facilities and returning it there will be paid by

TEINNOVA. If it is excluded from warranty (section 2 ), the transport, both collection at the customer’s premises and the return of the product, will be at the client’s expense. “TEINNOVA” reserves the right to dismiss the application of the guarantee in the event that the product shows no evidence of non-conformity. Equally, the application will not be accepted until the coverage has been explicitly approved. In the case that the product is covered, “TEINNOVA” can replace it or determine the necessary repair method.

All repair works that are carried out under the product guarantee must be carried out in “TEINNOVA” facilities or in those of the party it designates. The guarantee covers the materials and labour required to repair or replace the parts or elements considered as defective from origin. The maximum guaranteed amount or value shall be the  maximum price of the sale of the product to the“Buyer”.

Any claims made under the coverage of the guarantee shall not grant the right to delay and/or withhold payment of the corresponding invoice and/or any other pending invoices.

Guarantee Exclusions: The following are excluded from the guarantee: Intervening, handling and tampering with the product without the prior express authorisation of the Seller; indirect and/ or consequential damage; damage caused by negligence, by improper use or by usage that does not conform to the instructions and intentional damage; faults due to adaptations made to the products or the use of parts that were not previously and expressly certified or authorised by the Seller; costs for detection of the fault; costs for collection or replacement (the latter two are unless the non-conformity is proven and within the limits established in section 1).

declaration of conformity “CE”

MODEL: OZOAIR

SERIAL NUMBER: SD31401000000 – SD314010099999

MANUFACTURER INFORMATION:

Manufacturer name: tecai innova s.l.
Telephone number: +34 941 44 50 56
Fax: +34 941 25 24 71
Web: www.teinnova.net

TECAI INNOVA, SL, under its sole responsibility, certifies that the machine model described above complies with all the essential requirements of the following directives:

  • Machinery directive 2006/42/CE
  • Directive 2014/30/EU on electromagnetic compatibility and its amendments.
  • Directive 2014/35/EU on the sale of electrical equipment.

RESPONSIBLE FOR THE TECHNICAL DOSSIER:

Technical Director
armando sáenz angulo
Pol. Ind. Cantabria, C/Las Balsas 16
26009 Logroño (La Rioja)

Signature
signature: armando sáenz angulo Director Técnico Made in Logroño, 8 June 2020

© This instruction manual is protected by copyright. We reserve all rights, especially the right to produce, translate and process with electronic systems.