TEiNNOVA fogair+ Cordless Nebulising Kit User Manual
- June 13, 2024
- TEiNNOVA
Table of Contents
- fogair+ Cordless Nebulising Kit
- introduction
- Training service
- Technical service
- table of contents
- symbols used
- know your equipment
- EQUIPMENT PARTS AND CONTENTS
- safety warnings
- Personal Protective Equipment
- operating instructions
- troubleshooting guide
- technical specifications
- maintenance and care
- waste management
- accessories and consumables
- guarantee conditions
- declaration of conformity “CE”
- Documents / Resources
Cordless nebulising kit for the
effective disinfection of surfaces.
fogair+ Cordless Nebulising Kit
user manual
© This instruction manual is protected by copyright. We reserve all rights, especially the rights to produce, translate and prepare it using electronic systems.
introduction
Dear Customer,
Thank you for placing your trust in a quality product from TEINNOVA.
This product has been made using modern manufacturing techniques and thorough
quality assurance measures.
We strive to do everything we can to make sure you are satisfied with this
product and can operate it without any issues.
Should you have any questions about this product, please contact either your
stockist or us directly.
Before use, carefully read the operating instructions for your equipment.
Treat this manual as part of the product and always keep it nearby for future
reference.
Training service
We offer companies optional training that is specific to our products and also teaches their operators how to provide the best service and thus contribute to the success of their end customers. Aspects such as knowing how to prepare a fair and objective quote, to respond to specific problems that may arise, or to offer a more professional and efficient service.
Technical service
Because we manufacture our own cleaning equipment we can constantly control
the quality and performance of each product we manufacture. This is what has
allowed us to maintain low-cost service rates which have always been settled
by quickly our own Technical Support Service who are managed by the same team
as our factory.
We have all kinds of spare parts for your equipment, as well as related
accessories.
table of contents
symbols used
All the symbols used in this manual, as well as those on the equipment itself,
are explained in this section. It is important to read the text associated
with these symbols carefully, since it is about personal safety and equipment
safety.
DANGER!
This symbol warns of a potentially dangerous situation that could result in
serious injury or even death if the given instructions are not followed
appropriately. Make sure you read all the instructions in the “Safety
Information” section.
WARNING!
This symbol warns of a potentially dangerous situation that could result in
minor or moderate injury, or damage to property resulting in injury to people
if the given instructions are not followed appropriately.
ATTENTION!
This symbol warns you of a situation that may cause damage to property,
without causing injury, if the given instructions are not followed
appropriately.
IMPORTANT!
This symbol highlights information relating to the best way to use the
equipment while avoiding any possible improper operation.
know your equipment
DESCRIPTION AND CONTENT
The ULV (ultra-low volume) electric nebuliser generates large volumes of air
at low pressure. The cold fog of small particles, between 10 and 80 microns,
that disperse in the air and land on all surfaces, without staining them,
using very little product in its application of disinfectants for eliminating
bacteria, fungi and viruses. It is a cordless device with a long-lasting
lithium battery, which allows the operator to move freely through any spaces
without having to plug it in.
APPLICATIONS
| Disinfection of spaces
---|---
| Disinfection of air ducts
| Vehicles of all kinds
| RECHARGEABLE LI-ION BATTERY
| PRODUCT TANK 8 litres
| SILENT
EQUIPMENT PARTS AND CONTENTS
Product tank
know your equipment
EQUIPMENT PARTS AND CONTENTS
A flat-head screwdriver is needed to change the misting nozzles.
INTERCHANGEABLE NOZZLES
OUTLET | DROPLET | FLOW RATE |
---|---|---|
0,5 mm | 10 micras | 30m1/min |
1,0 mm | 40 micras | 125m1/min |
1,5 mm | 80 micras | 300m1/min |
Come as standard with the equipment
USE OF THE EQUIPMENT’S BATTERY
Control panel, press the red TEST button to check the battery charge level, if
the light is red then the battery needs to be fully recharged.
The autonomy of the equipment is 100 to 120 minutes after a full battery
charge.
CHARGING THE BATTERY
- Disconnect the battery from the equipment disconnecting the connector.
- Remove the battery from the housing by pulling the top handle until it is outside the box.
- Connect the battery to the charger and wait for it to be 100% charged.
- Put the battery back into the equipment box with the TEST panel facing outwards, connect the battery cable to the equipment cable.
safety warnings
FOGAIR+ must not be used for anything other than the uses described in this manual.
Anyone who uses the FOGAIR must be properly trained and must use the appropriate protective equipment.
Store the equipment properly for transport.
Check the equipment regularly for breakages and to verify its condition.
In the event of a fault, please contact TEINNOVA Technical Assistance Service on +34 941 44 50 56.
Personal Protective Equipment
operating instructions
Before use:
Calibrate the flow regulator which is located at the end of the hose. To do
this, turn the flow regulator until it is completely closed. Once closed,push
the base of the regulator downwards and bring it in line with the groove of
the air output.
Operation:
Never overfill the 8-litre/2.1-gallon tank capacity.
Mix the chemicals in a separate container, then add them to the tank once
mixed.
During use:
Do not place the FOGAIR directly on the floor, so as to avoid contact with
dust and dampness. When working in a small area, do not leave the FOGAIR
running for more than 30 minutes. The amount of liquid misted will depend on
the type of nozzle fitted.
troubleshooting guide
problem | solution |
---|---|
Low fog potency. | Ensure the lid of the tank is tightly closed. |
Liquid forms around the motor casing and the bolts. | The equipment has been |
running for too long and this has made droplets form around the screws.
The nebuliser is behaving erratically, turning
itself on and off.| Check the battery is sufficiently charged. The motor could
be damaged or worn.
The nebuliser heats up during normal usage.| Clean the filters at the bottom
of the equipment.
technical specifications
TECHNICAL FEATURES
Nominal voltage Motor power | 24V- 30Ah 260 W |
---|---|
Coverage | 5 to 7 metres |
Droplet size | adjustable from 10 to 80 microns |
Injected flow rate | 30 a 300 ml/min |
Tank capacity | 8 litres / 2.1 gallons |
Hose length | 100 cm / 39,3inch |
Sound level | 60 dB |
Dimensions L x W x H
L xWx H| 980 x 150 x 250 mm 38,5 x 5,9 x 9,8 inch
Empty weight| 5,2 kg / 12 lb
maintenance and care
Inspect the venturi tube of your FOGAIR+ after use to check for any wear or damage. If the venturi tube shows signs of wear or damage, the droplet size will not be correct and it will have to be replaced.
Regularly examine all soft parts such as hoses and gaskets to check for wear. If they are broken or damaged, they should be changed.
Like any device for applying chemical products, you will always need to clean all the equipment’s parts to avoid the build-up of residues that may affect its performance.
Clean the filters, located in the motor’s lower cover, regularly.
Spare Parts:
TEINNOVA has spares for all the equipment parts.
If you need any part or consumable, please contact TEINNOVA Customer Service on +34 941 44 50 56.
Servicio Técnico |
Technical Service
+34 674 837 357
waste management
The materials used in the packaging are recyclable. Do not dispose of
the packaging in household waste, but hand it in at official collection points
for recycling.
Do not dispose of electrical equipment in the trash!
We recommend that electrical tools and accessories are subjected to an
environmentally friendly recovery process.
Please dispose of the materials in the appropriate container or go to your
local collection point.
Directive 2012/19/EU of 4 July 2012 on waste electrical and electronic
equipment (WEEE).
accessories and consumables
CONSUMABLES
AK-GERMA 100
Super concentrated disinfectant
for germs, fungi and viruses.
1 litre pack
CODE PQ8400113
BATTERY SPARE RECHARGEABLE
LI-ION.
CODE AC3304700
guarantee conditions
-
TEINNOVA” guarantees its products for a period of 15 days when dealing with aesthetic defects or product faults which are noticeable at first sight, and for a period of 1 year when dealing with all other manufacturing defects or product faults. The “Buyer” must report the existence of any defect as soon as they become aware of it and, in any case, within the maximum period of 5 days from when it becomes apparent. Any notification outside of this deadline shall lead to the non-application of the guarantee. “TEINNOVA” will collect and send the products to the factory or to the closest official Technical Support Service for inspection. At this point, it will be determined whether the guarantee can be applied or whether it falls under the guarantee exclusions. If the guarantee is applicable, the transport fees, both those for collecting the product from the client’s facilities and for returning it there will be paid by TEINNOVA. If it is excluded from the guarantee (section 2), the transport fees, both those for collecting the product from the client’s facilities and returning it there will be paid by the client. “TEINNOVA” reserves the right to dismiss the application of the guarantee in the event that there is no evidence of the product’s non-conformity, and it shall not apply said guarantee until coverage has been expressly approved. In the case that the product is covered, “TEINNOVA” can replace it or determine the necessary repair method.
All repair works that are carried out under the product guarantee must be carried out in “TEINNOVA” facilities or in those of the party it designates. The guarantee covers the materials and labour required to repair or replace the parts or elements considered as defective from origin.
The maximum guaranteed amount or value shall be the maximum price of the sale of the product to the “Buyer”.
Any claims made under the coverage of the guarantee shall not grant the right to delay and/or withhold payment of the corresponding invoice and/or any other pending invoices. -
Guarantee Exclusions: The following are excluded from the guarantee: Actions, alterations or manipulations of the product that are carried out without the prior express authorisation of the Seller; indirect and/or consequential damage; damage caused by negligence, by improper use or by usage that does not conform to the instructions and intentional damage; faults due to adaptations made to the products or the use of parts that were not previously and expressly certified or authorised by the Seller; costs for detection of the fault; costs for collection orreplacement (the latter two are unless the non-conformity is proven and within the limits established in section 1).
declaration of conformity “CE”
MODEL: FOGAIR +
SERIAL NUMBER: SD31402070000 – SD31402079999
MANUFACTURER INFORMATION:
Manufacturer name: tecai innova s.l.
Telephone number: +34 941 44 50 56
Fax: +34 941 25 24 71
Web: www.teinnova.net
TECAI INNOVA, SL, under its sole responsibility, certifies that the machine model described above complies with all the essential requirements of the following directives:
- Machinery directive 2006/42/CE
- Directive 2014/30/EU on electromagnetic compatibility and its amendments.
- Directive 2014/35/EU on the sale of electrical equipment.
RESPONSIBLE FOR THE TECHNICAL DOSSIER:
Technical Director
armando sáenz angulo
Pol. Ind. Cantabria, C/Las Balsas 16
26009 Logroño (La Rioja) ****
signature: armando sáenz angulo
Technical Director
Made in Logroño, 9 August 2020 teinnova.net
Documents / Resources
|
TEiNNOVA fogair+ Cordless Nebulising
Kit
[pdf] User Manual
QR FAP, fogair, fogair Cordless Nebulising Kit, Cordless Nebulising Kit,
Nebulising Kit, Kit
---|---
References
- Duct cleaning equipment - Air duct cleaning and Kitchen exhaust cleaning equipment
- Duct cleaning equipment - Air duct cleaning and Kitchen exhaust cleaning equipment
- Duct cleaning equipment - Air duct cleaning and Kitchen exhaust cleaning equipment
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>