MEAN WELL LCM-60DA 60W Multiple Stage Constant Current Mode LED Driver Series Owner’s Manual
- June 13, 2024
- MEAN WELL
Table of Contents
- MEAN WELL LCM-60DA 60W Multiple Stage Constant Current Mode LED Driver
- ■Features
- ■Description
- ■ GTlN CODE
- ■ Model Encoding
- SPECIFICATION
- BLOCK DIAGRAM
- DIP SWITCH TABLE
- SYNCHRONIZATION OPERATION
- Sensed Temperature(℃)
- Installation Manual
- Read More About This Manual & Download PDF:
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
MEAN WELL LCM-60DA 60W Multiple Stage Constant Current Mode LED Driver
Series Owner’s Manual
■Features
‧Constant Current mode output with multiple
levels selectable by dip switch
‧Emergency lighting application is available according to lEC61347-2-13
‧Built-in active PFC function and class ll design
Standby power consumption <0.5W
Functions: DALl interface(logarithm or linear
dimming curve selectable), push dimming
synchronization up to 10units
‧3 years warranty
■Description
‧LED indoor lighting
‧LED office lighting
‧LED commercial lighting
‧LED panel lighting‧lndustrial lighting
■ GTlN CODE
MW Search:
https://www.meanwell.com/serviceGTlN.aspx
LCM-60DA series is a 60W AC/DC constant current mode output LED driver
featuring
the multiple levels selectable by dip switch and the DALl interface with the
compliance to lEC62386. LCM-60DA operates from 180~295VAC and offers different
current
levels ranging between 500mA and 1400mA. Thanks to the high efficiency up to
92%, with the fanless design, the entire series is able to operate for
-30℃~+90℃ case temperature under free air convection. ln addition, LCM-60DA is
equipped with push dimming and
synchronization functions, so as to provide the optimal design flexibility for
LED lighting system
■ Model Encoding
Type | Function | Note |
---|---|---|
Blank | standby power consumption <0.5W | ln Stock |
AUX | standby power consumption <1.2W and Auxiliary DC output(12V/50mA) | By |
request
SPECIFICATION
MODEL | LCM-60 – |
---|
OUTPUT
| CURRENT LEVEL| Current level selectable via DIP switch, please refer to”DIP
SWITCH TABLE” section
500mA| 600mA| 700mA(default)| 900mA| 1050mA| 1400mA
RATED POWER| 60.3W
DC VOLTAGE RANGE| 2 ~ 90V| 2 ~ 90V| 2 ~ 86V| 2 ~ 67V| 2 ~ 57V| 2 ~ 42V
OPEN CIRCUIT VOLTAGE (max.)| 95V| 73V
CURRENT RIPPLE Note.5| 5.0% max. @rated current
CURRENT TOLERANCE| ±5%
AUXILIARY DC OUTPUT| Nominal 12V(deviation 11.4~12.6V)@50mA for AUX-Type only
SETUP TIME Note.3
Note.9
| 500ms / 230VAC
INPUT
| VOLTAGE RANGE Note.2| 180 ~ 295VAC 254 ~ 392VDC
(Please refer to “STATIC CHARACTERISTIC” section)
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR (Typ.)| PF≧0.975/230VAC, PF≧0.95/277VAC@full load
(Please refer to “POWER FACTOR (PF) CHARACTERISTIC” section)
TOTAL HARMONIC DISTORTION| THD< 20%(@load¾75%)
(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)
EFFICIENCY (Typ.) Note.4| 92%
AC CURRENT (Typ.)| 0.32A/230VAC 0.27A/277VAC
INRUSH CURRENT (Typ.)| COLD START 20A(twidth=270μs measured at 50% Ipeak) at
230VAC; Per NEMA 410
MAX. No. of PSUs on 16A CIRCUIT BREAKER| 25 units (circuit breaker of type B)
/ 32 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT| <0.5mA / 240VAC
STANDBY POWER CONSUMPTION Note.6| <0.5W for Blank-Type, <1.2W for AUX-Type
PROTECTION
| SHORT CIRCUIT| Constant current limiting, recovers automatically after fault
condition is removed
OVER VOLTAGE| 105 ~ 125V
Shutdown o/p voltage, re-power on to recover
OVER TEMPERATURE| Shutdown o/p voltage,re-power on to recover
FUNCTION
| DIMMING| Please refer to “DIMMING OPERATION” section
SYNCHRONIZATION| Please refer to “SYNCHRONIZATION OPERATION” section
TEMP. COMPENSATION| By external NTC, please refer to “TEMPERATURE COMPENSATION
OPERATION”section
ENVIRONMENT
| WORKING TEMP.| Tcase=-30 ~ +90℃ (Please refer to “ OUTPUT LOAD vs
TEMPERATURE” section)
MAX. CASE TEMP.| Tcase=+90℃
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +80℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z
axes
SAFETY & EMC
|
SAFETY STANDARDS
| UL8750(except for DA2-Type), CSA C22.2 No.250.13-12, ENEC BS EN/EN61347-1, BS EN/EN61347-2-13, BS EN/EN62384
independent,GB19510.14, GB19510.1,BIS IS15885(except for DA2-Type), EAC TP TC 004 approved; According to BS EN/EN61347-2-13 appendix J suitable for emergency installations(EL)(AC Input: 200-240Vac)(for DA2-Type only)
DALI STANDARDS| IEC62386-101, 102, 207,251
WITHSTAND VOLTAGE| I/P-O/P:3.75KVAC; I/P-DA:1.5KVAC; O/P-DA:1.5KVAC
ISOLATION RESISTANCE| I/P-O/P:>100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION Note.7| Compliance to BS EN/EN55015, BS EN/EN61000-3-2 Class
C(@load≧40%) ; BS EN/EN61000-3-3; GB17625.1,GB17743, EAC TP TC 020
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61547,
light industry level(surge immunity Line-Line 2KV), EAC TP TC 020
OTHERS
| MTBF| 2270.7K hrs min. Telcordia SR-332 (Bellcore) ; 193.7K hrs min.
MIL-HDBK-217F (25℃)
DIMENSION| 123.581.523mm (LWH)
PACKING| 0.24Kg ; 54pcs/15Kg/1.12CUFT
NOTE| 1. All parameters NOT specially mentioned are measured at 230VAC input,
rated current and 25℃ of ambient temperature.
2. De-rating may be needed under low input voltages. Please refer to “STATlC CHARACTERlSTlC” sections for details.
3. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.
4. Efficiency is measured at 900mA/67V output set by DlP switch.
5. Current ripple is measured 60%~100% of maximum voltage under rated power delivery.
6. Standby power consumption is measured at 180~230VAC.
7. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
8. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
9. Based on lEC 62386-101/102 DALl power on timing and interruption regulations, the set up time needs to test with a DALl controller which
can support for DALl power on function, otherwise the set up time will be higher than 0.5 second for DA2-type.
10. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently connected to the mains.
※ Product Liability Disclaimer:For detailed information, please refer to https://[www.meanwell.com/serviceDisclaimer.aspx](http://www.meanwell.com/serviceDisclaimer.aspx)
BLOCK DIAGRAM
DIP SWITCH TABLE
LCM-60DA/DA2 is a multiple-stage constant current driver, selection of output current through DIP switch is exhibited below
Io DIP S.W. | 1 | 2 | 3 | 4 | 5 | 6 |
---|---|---|---|---|---|---|
500mA | —- | —- | —- | —- | —- | —- |
600mA | ON | —- | —- | —- | —- | —- |
700mA(factory default) | ON | ON | —- | —- | —- | —- |
900mA | ON | ON | ON | —- | —- | ON |
1050mA | ON | ON | ON | ON | —- | ON |
1400mA | ON | ON | ON | ON | ON | ON |
DIMMING OPERATION
※PUSH dimming(primary side)
Action | Action duration | Function |
---|---|---|
Short push | 0.1~1 sec. | Turn ON-OFF the driver |
Long push | 1.5~10 sec. | Every Long Push changes the dimming direction, dimming |
up or down
Reset| >11 sec.| Set up the dimming level to 100%
‧The factory default dimming level is at 100%.
If the push action lasts less than 0.05 sec., it will not lead to a change for
the status of the driver.
‧Up to 10 drivers can perform the PUSH dimming at the same time when utilizing
one common push button.
‧The maximum length of the cable from the push button to the last driver is 20
meters.
‧The additive push button can be connected only between the PUSH terminal, as
displayed in the diagram,and AC/L (in brown or black); it will lead to short
circuit if it is connected to AC/N.
※DALI interface(primary side; for DA/DA2-Type)
‧Apply DALI signal between DA+ and DA-
‧DALI protocol comprises 16 groups and 64 addresses.
‧First step is fixed at 6% of output.
SYNCHRONIZATION OPERATION
LCM-60DA/DA2 have the built-in temperature compensation function ; by connecting a temperature sensor (NTC resistor) between the +NTC / -NTC terminal of LCM-60DA/DA2 and the detecting point on the lighting system or the surrounding environment, output current of LCM-60DA/DA2 could be correspondingly changed, based on the sensed temperature, to ensure the long life of LED.
Sensed Temperature(℃)
◎ LCM-60DA/DA2 can still be operated normally when the NTC resistor is not connected and the value of output current will be the current level selected through the DIP switch.
NTC reference:
NTC resistance | Output Current |
---|---|
220K | < 60℃, 100% of the rated current (corresponds to the setting current |
level)
60℃, output current begins to reduce, please refer to the curve for details.
330K| < 70℃, 100% of the rated current (corresponds to the setting current level)
70℃, output current begins to reduce, please refer to the curve for details.
470K| < 80℃, 100% of the rated current (corresponds to the setting current level)
80℃, output current begins to reduce, please refer to the curve for details.
Notes: 1. MEAN WELL does not offer the NTC resistor and all the data above are measured by using THINKING TTC03 series.
- If other brands of NTC resistor is applied,please check the temperature curve
◎ Dimming and synchronization function of the driver will be invalid when the “temperature compensation” function is in use.
OUTPUT LOAD vs TEMPERATURE
TOTAL HARMONIC DISTORTION (THD
Installation Manual
Please refer to : http://www.meanwell.com/manual.html