NIGHTSTICK XPP-5422B Dual Light Flashlight Instruction Manual
- June 13, 2024
- NIGHTSTICK
Table of Contents
**NIGHTSTICK XPP-5422B Dual Light Flashlight Instruction Manual
**
WARNINGS – INTRINSICALLY SAFE
-
Warning: Use only the approved non-rechargeable batteries listed below.
-
Warning: Do NOT attempt to use rechargeable AA batteries with this light.
-
Warning: To prevent ignition of a hazardous atmosphere, do not open the lens bezel in the hazardous environment. This task must ONLY be performed in an area known to be non-hazardous.
Warning: When exchanging batteries, use only Duracell PC1500, Energizer EN91 or Energizer L91 batteries. -
Warning: To prevent ignition of a hazardous atmosphere, the AA batteries must only be exchanged in an area known to be non-hazardous.
-
Warning: To reduce the risk of explosion, do not mix new non-rechargeable batteries with used non-rechargeable batteries, or mix non-rechargeable batteries from different manufacturers.
-
Warning: Substitution of components may impair intrinsic safety.
SPECIAL INSTRUCTIONS FOR INTRINSIC SAFETY
For personal safety, always confirm the rating of any known hazardous or potentially hazardous location where the light is to be used.
BATTERY INSTALLATION\
WARNING: In order to maintain the Intrinsically Safe rating, the only AA batteries certified for use with this light are the Duracell PC1500, Energizer EN91 or Energizer L91 batteries.
- Do not attempt to use any other brand or model of AA batteries with this light.
- Do not attempt to use any type of rechargeable AA batteries with this light.
Warning: To prevent ignition of a hazardous atmosphere, do not remove the lens bezel or the reflector / battery carrier in the hazardous environment. This task must ONLY be done in an area known to be non-hazardous.
- Loosen the locking screw located on the side of the lens cap. NOTE: Do NOT attempt to completely remove the locking screw. Doing so is not necessary and may damage the threads. The screw simply needs to be loosened enough to allow the lens bezel to unscrew.
- Unscrew the lens bezel from the housing in a counter-clockwise direction.
- Turn the light upside down and carefully shake the light in order to remove the reflector / battery carrier. Allow the reflector / battery carrier to slide into your hand. WARNING: Do NOT touch the reflector surface with your finger. Doing so may damage the reflector surface.
- Using 3 – AA Duracell PC1500, Energizer EN91 or Energizer L91 batteries (make sure that all 3 batteries are of the same model), install the batteries in the carrier paying close attention to the markings on the battery carrier for proper battery terminal polarity alignment.
- Align the reflector / battery carrier so that the switches on the carrier are aligned with the switches on the housing. Carefully insert the reflector / battery carrier back into the flashlight housing until it is fully seated in the housing. WARNING: Be careful to not touch the reflector surface with your finger. Doing so may damage the reflector surface.
- Replace the lens bezel by screwing it onto the housing in a clockwise direction.
- Tighten locking screw. CAUTION: Do not over-tighten. Doing so may damage the threads and impact the light’s Intrinsic Safety.
OPERATION
THE FLASHLIGHT HAS FOUR SEPARATE LIGHTING MODES:
MOMENTARY FLASHLIGHT MODE
Lightly press the top body switch for momentary operation. Release the switch
to turn the light off.
CONSTANT-ON FLASHLIGHT MODE
Press the top body switch until it clicks and then release for constant-on
mode. Press and release the top body switch again to turn the light off.
FLOODLIGHT MODE
Press the bottom body switch until it clicks and then release for floodlight
mode. Press and release the bottom body switch again to turn the light off.
DUAL-LIGHT MODE
Dual-Light allows the user to turn on both the Flashlight and the
Floodlight, at the same time. Press the top body switch until it clicks and
then release for constant-on mode Flashlight Mode. Next press and release the
bottom switch to activate the Floodlight. Both the Flashlight and the
Floodlight are now running. Press and release both the top and bottom body
switches to turn the lights off.
WARRANTY
LIMITED LIFETIME WARRANTY
Bayco Products, Inc. warrants this product to be free from defects in
workmanship and materials for the original purchaser’s lifetime. The Limited
Lifetime Warranty includes the
LEDs, housing and lenses. Rechargeable batteries, chargers, switches,
electronics and included accessories are warranted for a period of two years
with proof of purchase. Normal wear and failures which are caused by
accidents, misuse, abuse, faulty installation and lightning damage are
excluded.
We will repair or replace this product should we determine it to be defective. This is the only warranty, expressed or implied, including any warranty of merchantability or fitness for a particular purpose.
For a complete copy of the warranty, go to www.baycoproducts.com/bayco- productsupport/warranties. Retain your receipt for proof of purchase.
EU / UK Declaration of Conformity
Model(s):| XPP-5420BA / GA / GXA XPP-5422BA / GA / GXA XPP-5422GMA / GMXA|
Declaration Number:| 20140104-F
---|---|---|---
Product Type:| Portable Flashlight
Company Name:| Bayco Products Inc.
---|---
Address:| 640 S. Sanden Blvd.
City, State, Postcode:| Wylie, Texas 75098 USA
Phone / Website:| 001-469-326-9400 /
www.nightstick.com
We hereby declare that the product identified above meets the requirements of the Directives listed below. Therefore, they qualify for free movement within markets comprising the European Union (EU), the European Economic Area (EEA) and the United Kingdom (UK). This declaration is issued under the sole responsibility of the manufacturer.
The following EU harmonized, UK designated standards and technical
specifications have been applied
and evaluated by:
Directives:| ATEX Directive 2014/34/EU| UKSI 2016 No. 1107| Article 34 of the
Industrial Safety and Health Act and Article 58-4,Paragraph 4 of the
Enforcement Rule of thesame Act.
---|---|---|---
Notified Body:| INTERTEK ITALIA SPA Via Guido Miglioli, 2/A 20063
Cernusco sul Naviglio (MI)Italy| INTERTEK TESTING & CERTIFICATION
LTDAcademy Place, 1-9 Brook St.Brentwood, Essex, CM14 5NQ United Kingdom|
Korea Occupational Safety and Health Agency
Notified Body Number:| 2575| 0359| N/A
Certificate Number:| ITS13ATEX27837X| ITS21UKEX0264X| 21-AV4BO-0137X
Standards:| EN 60079-0: 2018| IEC 60079-0: 2018
EN 60079-11: 2012 (ia)| IEC 60079-11: 2012
EN 60079-26: 2015| IEC 60079-26: 2015
EN 50303: 2000|
Type Approval:| IM1 Ex la op is I
Ma 1 G Ex la op is IIC T3 Ga
| For 5420GXA / 5422GXA
5422GMXA
These Products are fully compliant and do not contain the restricted substances above levels noted in EU and UK RoHS.
Name: Mark Situ
Title: Quality Director
Date: 9th August 2022
THE XPP-5422 IS APPROVED FOR USE
Bayco Products, Inc. XPP-5422B
640 S. Sanden Blvd.
ylie, TX 75098
640 S. Sanden Blvd
Permissible Nightstick 5422 Flashlight
APPROVAL No. 20-A130001-0
TESTED FOR INTRINSIC SAFETY IN METHANE-AIR MIXTURES ONLY
WARNINGS:
- MSHA approved for use with three AA Duracell Type PC1500, Energizer Type EN91, and Energizer Type L91 batteries only.
- Replace the batteries in fresh air only and replace all batteries at the same time. Do not mix batteries from different manufacturers or of different types.
- Energizer Lithium (Type L91) batteries are to be replaced by a qualified technician only.
- The Model Nightstick 5422 must not be opened in areas where permissibility is required.
ID 4003544
INTRINSICALLY SAFE
SECURITE INTRINSEQUE
CLASS I DIV 1 GRPS A-D T3
CLASS II & III DIV 1 GRPS E-G T135C
CLASS I ZONE 0 IIC T3
CLASS II ZONE 20 IIIC T135C
-20ºC ≤ Tamb ≤ +40ºC
1.5V/Cell AA Alkaline
ID 4003544
INTRINSICALLY SAFE
SECURITE INTRINSEQUE
Ex ia op is I Ma
Ex ia op is IIC T3 Ga
Intertek ITS 13 ATEX 27837X
ITS21UKEX0264X
IECEx ITS 16.0067X
-20ºC ≤ Tamb ≤ +40ºC
1.5V/Cell AA Alkaline
2575
CLASS I DIV 1 GRPS A-D T3
CLASS II & III DIV 1 GRPS E-G T135C
CLASS I ZONE 0 AEx ia IIC T3 Ga
CLASS I ZONE 0 Ex ia IIC T3 Ga
M 1 Ex ia op is I Ma
1 G Ex ia op is IIC T3 Ga
0359
Conforms to:
ANSI/UL STD 913, ANSI/UL 60079-0,
ANSI/UL 60079-11 ANSI/ISA 60079-26
Certified to:
CAN/CSA STD C22.2 No 157
CAN/CSA STD C22.2 No 60079-0
CAN/CSA STD C22.2 No 60079-11
CSA STD C22.2 No 25
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>