REPOTEC 02-RP-IPG814-2F Hardened Industrial 16 Port Gigabit PoE Switch User Manual
- June 13, 2024
- REPOTEC
Table of Contents
REPOTEC 02-RP-IPG814-2F Hardened Industrial 16 Port Gigabit PoE Switch
Product Information
Section | Content |
---|---|
Introduction | This product is a network switch that complies with |
electromagnetic compatibility requirements. It supports wall mount
and din-rail mount installation. The package includes wall mount
brackets and a din-rail bracket.
Power Connection| Follow the power connecting procedure provided below.
LED Indicator| The device has LED indicators for P1, P2, and P3. Refer to the
provided information on LED states.
Specification| The product’s specifications include IEEE Standard compliance,
switch architecture, data processing, flow control, jumbo frame
support, MAC address table size, packet buffer size, network
connector, network cable protocol, LED features, reserve polarity
protection, and overload current protection.
Power Supply| The device is powered by PoE (Power over Ethernet) and has a
removable terminal block for power connection. Refer to the
provided information on power consumption and alarm relay
contact.
Operating Conditions| The product can operate within a specific temperature
and
humidity range. It is also suitable for storage within a certain
temperature range. The mean time between failure (MTBF) is provided
as an indication of reliability. The housing case is made of rugged
metal with IP30 protection. The dimensions of the case are 155 x 48
x 120 mm (LxWxD). The device can be installed using DIN Rail Mount
or Wall Mount methods.
Certifications| The product has obtained safety certifications such as UL
60950-1 and LVD (EN 62368-1). It also complies with EMC and EMI
requirements, including CISPR 32, FCC Part 15B Class A, and EN
55032/35. The device meets standards for vibration, shock, and free
fall resistance according to EN 60068-2-6, EN 60068-2-27, and EN
60068-2-32 respectively.
Product Usage Instructions
Power Connecting Procedure
- Ensure that the device is powered off and disconnected from the power source.
- Locate the power connection terminals on the device.
- Connect the power supply to the device using the provided removable terminal block. Ensure proper polarity.
- Once the power connection is secure, you can proceed to power on the device.
LED Indicator
The device has LED indicators for P1, P2, and P3. The following states
indicate their status:
- P1 (Green): ON – P1+ and P1- are connected.
- P2 (Green): ON – P2+ and P2- are connected.
- P3 (Amber): ON – P3 is connected via Power DIN.
FCC MARKING
This Equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received; including interference that may cause undesired operation.
CE MARKING
This equipment complies with the requirements relating to electromagnetic
compatibility, EN 55032/35 class A for ITE, the essential protection
requirement of Council Directive 2014/30/EU on the approximation of the laws
of the Member States relating to electromagnetic compatibility. The company
has an ongoing policy of upgrading its products and it may be possible that
the information in this document is not up-to-date. Please check with your
local distributors for the latest information. No part of this document can be
copied or reproduced in any form without written consent from the company.
Trademarks
All trade names and trademarks are the properties of their respective
companies. Copyright © 2022, All Rights Reserved.
Introduction
This Industrial PoE switch is designed with Hardened Ethernet and PoE controllers to ensure performance in harsh environments. It is equipped with 14 ports 30Watts Giga TX PSE and can deliver up to 300Watts of power to your PD devices. All 16 ports are independent and can all be used for easy expansion of your network application. Our unique Cold-Design technology, will not only power up your PD but also reduce its excessive heat to a minimum. It has been rigorously tested for your security, surveillance, and telco applications. This unit can also be cascaded/daisy-chained to other devices to cover wider areas through the SFP connection.
Installation package
This unit can be wall-mounted or din-rail mounted. Wall mount brackets and din-rail brackets are included.
Power connection
This unit provides a 6-pin terminal block. PoE functions can be operated from 48-56VDC power input. Always make sure your input voltage is within this supported voltage range for each model.
WARNING – Any exceeded input voltage will not make this unit function and may damage this unit. This unit comes with 3 power input sources. P1, P2, and P3. To connect power: Follow the printed polarity for P1+, P1-, P2+, P2-, and ground. Connect positive wires to P1+ and/or P2+, connect negative wires to P1- and/or P2-, and connect the neutral wire to the ground screw as shown.
Power DIN: This unit contains an extra P3 port for power DIN. This power
DIN can power the unit via an external power adapter.
Relay: This unit includes an additional 24V@1A relay circuit for special
purposes. When 2 powers are connected, the relay is in OPEN mode. If only one
of the power sources is connected, the relay changes to SHORT mode. This relay
will only work with P1 and P2. It is independent of P3.
Power connecting procedure
STEP 1 – Pull out 6 pin terminal block.
STEP 2 – Connect wire to P1+, P1-, P2+, P2-, and the neutral wire to the
ground screw.
STEP 3– Plug-connected 6-pin terminal block back into place. Or, Connect
the P3 power DIN from the external power adapter.
WARNING — Always SHUT OFF the power source to connect the power wire.
WARNING — Always ground the power source to maintain a clean power input.
Cheaply made power supplies create too much noise and will cause the power
input to fluctuate when connected to this unit. To avoid this, always ground
the power source to maintain a clean power input.
LED indicator
Specification
IEEE Standard
| IEEE 802.3 10Base-T Ethernet
IEEE 802.3u 100Base-TX Fast Ethernet IEEE 802.3ab 1000Base-T Gigabit Ethernet IEEE 802.3z 1000Base-X Gigabit Ethernet
IEEE 802.3x Flow Control and Back Pressure IEEE 802.3af PoE
IEEE 802.3at PoE+
---|---
Switch Architecture| Back-plane (Switching Fabric): 32Gbps
Data Processing| Store and Forward
Flow Control| IEEE 802.3x Flow Control and Back Pressure
Jumbo Frame| 9KB
MAC address Table Size| 8K
Packet Buffer Size| 4.1Mbits
Network Connector
| 14 x RJ-45 10/100/1000BaseT(X) auto negotiation, Auto MDI/MDI-X function, Full/Half duplex
14 x Gigabit POE+ 802.3at/af PSE port, 30W per port
2 x SFP 1000M
Network Cable| UTP/STP Cat.5e or above Cable
EIA/TIA-568 (100m)
Protocol| CSMA/CD
LED
| PW1 (Green): ON-Power 1 is detected PW2 (Green): ON-Power 2 is detected
PW3 (Amber): ON-Power 3 is detected for Power DIN RLY (Amber): ON-Connect only PW1 or PW2
OFF-Both PW1 and PW2 are connected
TX/RJ-45 port:
LNK (Link/Active) (Green): ON-TX port is detected
Flashing-TX data is transmitting/receiving
PoE (Amber): ON-PD is detected and PSE is activated
OFF-PD is not detected
SFP Fiber Per port:
F15/F16 (Green)
ON – F15 or F16 SFP fiber is detected Flashing – F15 or F16 SFP fiber is active
Reserve polarity protection| Present
Overload current protection| Present
Power Supply| Redundant Dual DC 48V-56V Power Input
---|---
Power Consumption| 5.76W@48 VDC full load, Without PoE
Alarm Relay Contact
| Relay outputs with current carrying capacity of 1 A @24VDC, Relay in open circuit mode when 2 powers are connected. in
short circuit mode when only one power supply is connected
PoE power
| PoE power per port 30watts.
Maximum total power 300Watts with 56VDC input, Supports IEEE 802.3af/at
Removable Terminal Block
| Provide 2 Redundant power , Alarm relay contact ,6 Pin Wire range: 0.34mm^2 to 2.5mm^2
Solid wire (AWG):12-24/14-22 Stranded wire(AWG): 12-24/14-22 Torque:5lb- In/0.5Nm/0.56Nm
Wire Strip length: 7-8mm
Operating Temperature| -40°C to +75°C
Operating Humidity| 5% to 95% (Non-condensing)
Storage Temperature| -40°C to 85°C
MTBF (mean time between
failure)
| ****
504739 hrs (Telcordia (Bellcore), GB) at 50°C
Housing| Rugged Metal, IP30 Protection
Case Dimension| 155 x 48 x 120 mm (LxWxD)
Installation| DIN Rail Mount or Wall Mount
Certifications:
Safety| UL 60950-1
Safety| LVD (EN 62368-1)
EMC| CE, FCC, EN 55032/35
EMI| CISPR 32, FCC Part 15B Class A
EMS
| IEC 61000-4-2 ESD: Contact: 6KV; Air: 8KV IEC 61000-4-4 EFT: Power: 2KV; Signal: 2KV
IEC 61000-4-5 Surge: Power: 2KV; Signal: 2KV
Vibration| EN 60068-2-6
Shock| EN 60068-2-27
Free Fall| EN 60068-2-32
Housing Dimension (mm)
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>