REPOTEC DRS1000 500VA-1KVA DIN RAIL UPS User Manual
- June 13, 2024
- REPOTEC
Table of Contents
REPOTEC DRS1000 500VA-1KVA DIN RAIL UPS
Introduction
General description
The continuity of electrical power is an essential requirement for critical load operations .The Uninterruptible Power System (UPS) is designed to meet the user‘s need for the distribution box of important equipment. For example: PLC, and battery switch. To choose the UPS as your equipment protector is a wise investment because it supplies reliable, pure and stable power at affordable price.
Key features
- Reliable power for critical load operations
- 500VA and 1000VA power capacity options
- Ideal for distribution boxes with essential equipment
- High-frequency full bridge true sine wave technology
- Stable and pure power at an affordable price
- Built-in Lead-Acid battery
- RS-485 communication interface for monitoring and control
- Support for various types of loads, including inductive
- Lightweight and compact for easy transportation
- Cost-effective solution for uninterrupted power supply
- Ensures stability and flexibility in applications
- Emphasis on safety and proper operation
- Longevity and reliability for electrical equipment protection
- Wise investment for critical equipment protection.
Important notices
To be sure that the UPS will be operated correctly, the following items should be noticed:
- Read instructions carefully before operating the UPS.
- UPS power connect instruction should be followed.
- Please don‘t open the case to prevent danger.
- If the UPS will be stored for long period, the battery must be charged once every 90 days.
- Retain the load within the rating of UPS to prevent faults.
- Handle unusual events according to the trouble-shooting guide.
- Keep the UPS clean and dry
Safety instruction
Transporting
- Disconnect all power cables if necessary.
- Be carefully not to damage the UPS while transporting.
- Don‘t move the UPS upside down.
- Please transport the UPS system only in the original packaging (to protect against shock and impact).
Positioning
- Do not put the UPS on rugged or declined surface.
- Do not install the UPS system near water or in damp environments.
- Do not install the UPS system where it would be exposed to direct sunlight or near heat.
- Do not block off ventilation openings in the UPS system’s housing and don’t leave objects on the top of the UPS.
- Allow a minimum distance of 10 cm in the rear and two sides of the UPS for ventilation.
- Keep the UPS far away from heat emitting sources.
- Do not expose it to corrosive gas.
- Ambient temperature : 0℃ – 40℃
Installation
- The UPS must be connected to distribution box which have the earthed shockproof and the protection against electric current.
- Do not connect the secondary power equipment in distribution box to the UPS.
Operation
- The UPS has its own internal power source (batteries). The output terminals may be live even when the UPS is not connected to the AC supply.
- Ensure that no fluids or other foreign objects can enter the UPS system.
Maintenance and service
-
Caution – risk of electric shock.
Even after the UPS is disconnected from the mains power supply, components inside the UPS system are still connected to the battery and are still electrically live and dangerous. Before carrying out any kind of servicing and/or maintenance, disconnect the batteries and verify that no voltage is present. -
Only persons adequately familiar with UPS and with the required precautionary measures may exchange batteries and supervise operations.
Any unauthorized persons do not open cover for maintenance. -
The UPS with high voltage may cause electric shock and have a high short-circuit current. Please take the precautionary measures specified below and any other measures necessary when maintenance the UPS:
– remove wristwatches, rings and other metal objects
– use only tools with insulated tools and insulated gloves.
UPS description
DIN RAIL UPS ( LED , 500VA/1KVA)
- Plug AC power: To indicate the AC power is applied to the UPS input ( AC output is available at this time). Green LED flashing, but without alarm sound (beep). Battery LED : Green LED flashing and the alarm sounds(beeps). The buzzer stops alarm sounds (beeps) after alarm sounds 7 times
- Power (on): Press Power (on/off) button at least 3 seconds, the UPS will start up after two beeps and green LED lights up to finish startup procedure.
- Power (off): Press Power (on/off) button at least 3 seconds under operation mode, the UPS will shut down after two beeps and put out the LED, then the LED light flashes to finish shutdown procedure.
Outline ( 500VA / 1KVA )
Case view description (500VA / 1KVA )
1. LED | 5. Terminal block (input/output) |
---|---|
2. Power (on/off) button | 6. Breaker |
3. RS-485 port | 7. Fan |
4. Emergency power off (optional) | 8. Hander |
Casing back view description (500VA / 1KVA )
9. Rail (no supply)|
---|---
Terminal block
10. Input GND (Ground)| 13. Output L (Line)
11. Input N (Neutral)| 14. Output N (Neutral)
12. Input L (Line)| 15. Output GND (Ground)
Cable connection
Inspection
- The UPS may be installed and wired only by qualified electricians in accordance with applicable safety regulations.
- When installing the electrical wiring, please note the nominal amperage of your incoming feeder.
- Inspect the packaging carton and its contents for damage. Please inform the supplier should you find signs of damage.
Connection
- UPS input and output connection Connect AC input wires and wires of load to terminal block of the UPS. (About the terminal block, please refer to page 7)
UPS operation
Check prior to start up
- Ensure the UPS is in a suitable positioning.
- Check input cord is secured.
- Make sure the load is disconnected or in the “OFF” position.
- Check if input voltage meets the UPS rating required.
Operation procedure
Please follow the instructions below for the UPS operation.
- Once the AC source is connected, the LED is flashing immediately to indicate charging (AC output exits). LED is blinking if the AC source is abnormal.
- By pressing the Power (on/off) button at least 3 seconds until the buzzer beeps twice, the UPS will start up and LED lights up to finish startup procedure and the UPS is under Line mode.
Storage instruction
Disconnect input power in rear panel if you will not use it for long period.
If the
UPS is stored over 3 months, please keep supplying power to the UPS for at
least 24 hours to ensure battery fully recharged.
Trouble shooting guide
The following guideline may be helpful for basic problem solving
No. | UPS Status | Action |
---|---|---|
1 | AC source is normal, but the UPS can’t start successfully. | |
LED is flashing once every 2 seconds, but without buzzing. | Please check if |
turn on the UPS successfully.
2| AC source is normal, but the UPS is overload up to 110%.
LED is flashing and alarm sound (beeps) once every 0.4 seconds. LED put out
the light after 15
Seconds and the alarm sound (beeps) continuously.| Please reduce the load to
<100%.
3| AC source is normal, but the UPS is overload up to 120%. LED put out the
light and the alarm sounds (beeps) immediately.| Please reduce the load to
<100%.
4| AC source fails. The load is supplied by battery power. LED is flashing
once every 2 seconds and the alarm sound (beeps) once every 2.5 seconds. The
alarm sound stops beeping after 7 times.| If AC source fails, reduce the load
in order to extend backup time. If it is not abnormal power failure, please
check the rated input voltage or connected line.
---|---|---
5| AC source fails. The UPS is under battery mode and battery power is
approaching low level. The LED is flashing and buzzing once every 0.4
seconds.| The UPS will shut down automatically. Please save data soon.
6| AC source fails and battery runs out. The UPS has shut down automatically.|
The UPS will restart up when AC source is restored. If AC source failure is
more than 6 hours, please follow storage instruction.
Operation modes
UPS system block diagram
Normal operation
There are two main loops when AC power is normal: the AC loop and the battery charging loop. The AC output power comes from AC power input and passes through output replay to support power to load. The battery charging voltage comes from AC power input and converted by AC/DC charger to support battery- charging power.
AC source failure
The AC output comes from battery, passing through DC/AC inverter and static switch within the battery backup time.
Specification
Model | RP-DRS500 | RP-DRS1000 |
---|---|---|
Capacity | 500VA / 300W | 1KVA / 500W |
Input | Nominal voltage | 110/115/120Vac or 220/230/ 240Vac |
Acceptable voltage range | 85 ~ 135Vac / 170~ 270Vac | |
Frequency | 50Hz / 60Hz Auto sensing | |
Frequency range | 63Hz ~ 40Hz | |
Line low transfer | 170Vac ± 5% ; 85Vac ± 5% | |
Line low return | 180Vac ± 5% ; 90Vac ± 5% | |
Line high transfer | 270Vac ± 5% ; 135Vac ± 5% | |
Line high return | 260Vac ± 5% ; 130Vac ± 5% | |
Output | Voltage | 110/115/120Vac or 220/230/240Vac |
Waveform | Pure sine wave | |
Line mode | Short circuit protection : circuit breaker | |
Battery mode | Short circuit protection: electronic circuit | |
DC start | Cold start | Yes |
Transfer time | Typical | 10ms |
Battery | Battery voltage | 12Vdc |
Battery type | Lead-Acid 7Ah | Lead-Acid 7.5Ah |
Indicator | LED | AC mode (green lighting), Inverter mode (green flashing) |
Audible alarm | Battery mode | Sounding every 7 seconds |
Low battery | Sounding every second | |
UPS fault | Continuously sounding | |
Interface | RS-485 | |
Environment | Operation temperature | 0-40 degree C; 32-104 degree F |
Relative humidity | 0-90% non-condensing | |
Physical | ( W x H x D )mm | 250 135 115 |
Net weight (kgs) | 2.8 kgs | 3.1 kgs |
* Specifications are subjected to change without prior notice.