REPOTEC RPT-5715DU Line Interactive UPS User Guide

June 13, 2024
REPOTEC

REPOTEC RPT-5715DU Line Interactive UPS

Product Information

The product is an Automatic Voltage Regulation UPS with Line Interactive design and Microprocessor control. It is equipped with 2-Steps Boost & 1-Step Buck AVR to stabilize utility voltage. The UPS has a built-in DC start function that allows it to be started up without AC power supplied. It also features UPS Green Mode (Energy Saving Function), Off-mode Charging, and Modem/Phone line surge protection. The UPS has Over/Low Voltage, Short- Circuit, and Lightning/Surge(Optional) Protection. It includes a built-in CCCV (Constant Current, Constant Voltage) battery Charger for extended battery life.

Product Usage Instructions

  1. Read the Manual: Please read and understand the instructions manual provided with the product. It contains important safety, installation, and operation instructions for the best performance and safe usage of the equipment.
  2. Keep the Manual: Please keep the manual for future reference and to obtain the manufacturer’s support if needed.
  3. Recycle Packaging Materials: Please keep or recycle the packaging materials as they are necessary in case the equipment needs to be shipped back for service. Damage that occurs during shipment is not covered by the product’s warranty.
  4. Qualified Technician: The UPS contains potentially hazardous voltage. Only a qualified or certified technician should proceed with repairs and maintenance.
  5. Power On/Off: To turn on the UPS when connected to the city utility but not powered on, press the main switch on the front panel for 1 second. To turn off the UPS when under AC mode, press the main switch on the front panel for 4 seconds. To turn off the UPS when under battery mode, press the main switch and the UPS will shut down completely in 10 seconds. If you want to power off the UPS completely, remove the input power cord from the city utility.
  6. DC Start: In the event of a blackout, press the main switch for 4 seconds to turn on the UPS and enter backup mode. To turn off the UPS, press the main switch for 4 seconds again. If you want to turn on the UPS again, wait for 10 seconds before pressing the main switch for 4 seconds again.
  • Please read and understand this instructions manual!
  • This manual provides safety, installation, and operation instructions that will guide you to the best performance of your equipment.
  • Please keep this manual!
  • It includes important instructions for the safe usage of the equipment and to obtain manufacturer’s support in case of need.
  • Please keep or recycle the packaging materials!
  • Packaging materials used in our products are designed to provide protection from transportation
  • These materials are necessary in case the equipment needs to be shipped back for service
  • Damage that may occur during the shipment is not covered by the product’s warranty.

INTRODUCTION

System Description

  • The product is a line interactive UPS with LED indicators, the newest technology, and powerful function.
  • The Line Interactive UPS is designed with 2-Steps Boost and 1-Step Buck AVR to stabilize input voltage. Input voltage range is -30% +25%, but output regulation is +/-10%.
  • The Line Interactive UPS provides you with the ability of perfect protection for your critical devices.

Features

  • Line Interactive design
  • Microprocessor control guarantees high reliability
  • Frequency 50/60Hz auto-sensing
  • Equipped with 2-Steps Boost & 1-Step Buck AVR to stabilize utility voltage
  • Built-in DC start function enables UPS to be started
  • up without AC power supplied
  • UPS Green Mode (Energy Saving Function)
  • Off-mode Charging
  • Modem/Phone line surge protection
  • Over/Low Voltage, Short-Circuit, and Lightning /Surge (Optional) Protection
  • Built-in CV (Constant Current, Constant Voltage) Battery Charger

CAUTION

  • The UPS contains voltage that is potentially hazardous. Qualified or certified technicians should proceed with all repairs and maintenance.
  • The UPS has its own internal energy source (battery). The output receptacles may be active even when the UPS is not connected to an AC supply.
  • The UPS is suitable for computers and electronic equipment with substantial rectifier or capacitive loads, but not suitable for electronic equipment with significant inductive loads, such as motors & fluorescent lamps.
  • Be sure to operate within the power rating of the UPS. Below 1/2 or 1/3 of the rated power is recommended for longer backup time & longer battery life.
  • Do not place the UPS near excessive humidity, under sunshine, or close to heat-emitting sources.
  • If the UPS is out of order, detach the power cord and consult your dealer right away. Do not remove the cover; there is no serviceable part inside.
  • The unit should be supplied by a grounded source. Do not operate the unit without a ground source.
  • The socket should be installed near the equipment and be easily Accessible.
  • Do not plug the UPS’s power cord into itself.
  • That will result in a safety hazard.
  • A qualified technician or electrician in accordance with the local electrical code should perform the installation.

INSTALLATION

  • The UPS must be installed in a protected environment away from heat-emitting appliances such as a radiator or heater. Do not install this product where excessive moisture is present.
  • CAUTION: Never connect a laser printer or plotter to the UPS. A laser printer or plotter periodically draws significantly more power than its idle status and may overload the UPS.

OVERVIEW

Front Panel

  1. Main Power Switch: On/Off or Silence Button
  2. 0n-Line LED: AC normal
  3. Back-Up LED: Battery in backup
  4. Cut-Off LED: Overload or Fault

Rear Panel

  1. AC Input: Connect to the input power cord
  2. AC Fuse/ Circuit Breaker
  3. Back-up/ AVR Outlets
  4. Surge Protection Outlets
  5. RJ-45 port (Optional)
  6. Communication interface: USB port (Optional)

OPERATION

  • When UPS is connected to city utility, but UPS is not powered on, UPS will charge the battery automatically and the Green LED will flash every 2 seconds.
  • Please press main switch on front panel for 1 second to turn on UPS.
  • To turn off UPS when UPS is under AC mode, please press main switch on front panel for 4 seconds.
  • To turn off UPS when UPS is under battery mode, please press main switch and then UPS will shut down completely in 10 seconds.
  • This UPS is designed with “Off-mode charging”, so UPSwill charge battery continuously when UPS is under AC normal. If users intend to power off UPS completely, users have to remove input power cord from city utility.

DC Start:

  • Press on main switch for 4 seconds when city utility is black out, UPS will be turned on and then go to back up mode. To turn off UPS, please press main switch for 4 seconds again.If users want to turn on UPS again,please wait for 10 seconds to press main switch for 4 seconds again.
  • When UPS is under battery mode and battery voltage is too high or low, buzzer will beep.
  • Buzzer will beep twice every 8 seconds when city utility is black out. To silence alarm, please simply press main switch. To re-start alarm, please press main switch again.

STORAGE

  • To ensure battery lifetime, please kindly read and also follow below instruction completely.
  • This unit is shipped from the factory with its interna battery fully charged, however, some charge maybe lost during shipping and the battery should be recharged prior to use. Plug the unit into an appropriate power supply and allow the UPS to charge fully by leaving it plugged in for at least 10 hours.

Extended StorageREPOTEC-RPT-5715DU-Line-Interactive-UPS-
fig-12

BASIC INDICATION TABLE

REPOTEC-RPT-5715DU-Line-Interactive-UPS-
fig-10

R-LED: Depends on the fault conditionREPOTEC-RPT-5715DU-Line-
Interactive-UPS-fig-11

TROUBLESHOOTING

  • Upon UPS failure, please kindly check UPS by following the below steps. If there is no problem with the below points, please kindly send UPS for service
  • Is the main power switch turned on?
  • Is the UPS plugged into a working wall outlet?
  • Is the line voltage within the rating specified?
  • Is the fuse blown (at the rear panel)?
  • Is the UPS overloaded?
  • Is the battery not fully charged?
  • Please provide the following information when calling for service.
  1. Model number, serial number.
  2. Date of the problem occurred, date of purchase.
  3. Full description of the problem including load, LED, and alarm status, installation condition, and working environment at

INSTRUCTION TO CHANGE BATTERY

  1. Please place the UPS device as below picture.
  2. On the cover of the battery compartment, there is a round button
    • Please press the round button and then push the cover out till the arrows on the cover are aligned with the arrows on the UPS housing
    • After the arrows on the cover are aligned with the arrows on the UPS housing, the cover can be dismantled from the UPS housing easily.
  3. After the cover is dismantled, please pull out the battery and then disconnect wires from the battery’s positive and negative terminals.
    • Get a new battery and then connect wires to the positive and negative terminals of a new battery.
    • Please make sure to connect wires to positive and negative terminals correctly, otherwise UPS device might be damaged.
    • It is normal to have a small spark when connecting wires.
  4. Please take cover of the battery compartment and then align the arrows on the cover with the arrows on the UPS housing.
    • After the arrows are all aligned, push the cover in and then double-check if the cover is well-locked.
    • The cover has to be well-locked, otherwise battery might fall out under operation and cause danger.

SPECIFICATIONS