TESLA CD-24-20-001 Cybertruck Event Data Recorder Retrieval
Product Information
Specifications
- Product Name: Tesla Cybertruck Event Data Recorder
- Model Number: CD-24-20-001
- Date: 29 February 2024
Product Usage Instructions
Retrieving EDR Data from Tesla Cybertruck
The Tesla Cybertruck is equipped with an Event Data Recorder (EDR) that records data related to vehicle dynamics and safety systems in the event of a crash or crash-like situation. Follow the steps below to retrieve EDR data:
Step 1: Accessing the Restraint Control Module (RCM)
To access the RCM for data retrieval, the Cybertruck center console must be removed. Ensure the vehicle is powered off before proceeding.
Step 2: Establish a Direct-to-Module Connection
Connect the data transfer cables to the RCM using the special tools mentioned below:
- Tesla Part Number 1492139-00-A/B
Step 3: Retrieve EDR Data
Follow the instructions provided in the Service Manual for direct-to-module EDR data retrieval.
Tools Required
- Tesla Part Number 1492139-00-A/B
For Further Assistance
For technical support and assistance with EDR data retrieval, contact Crash Data Group:
- Email: crash@crashdatagroup.com
- Phone: (951) 252-9254
- Toll-Free: (800) 280-7940
FAQ
Q: Can I retrieve EDR data without removing the center console?
A: No, to retrieve EDR data from the RCM of a Tesla Cybertruck, the center console must be removed to establish a direct-to-module connection.
Introduction
The Tesla Cybertruck is equipped with an Event Data Recorder (EDR). The EDR records data related to vehicle dynamics and safety systems when the system senses a crash or a crash-like situation, such as hitting a road obstacle. This data is stored in the vehicle’s Restraint Control Module (RCM). This guide describes how to retrieve EDR data from the RCM of a Tesla Cybertruck.
This guide and other Tesla EDR information can be found at https://edr.tesla.com.
In order to retrieve EDR data using the direct-to-module connection method, the Cybertruck center console must be removed so that data transfer cables can be connected to the RCM. For more information about direct-to-module retrieval, refer to “Establish a Direct-to-Module Connection” section
Tools Required
To retrieve the data from the RCM, you will need the following special tools:
- PCAN-USB Adapter
- XP-10 Jump Pack
- A Windows computer running the Tesla EDR Retrieval Program, which you can download at https://edr.tesla.com/download.
- An appropriate data retrieval cable (cables and software are available at https://edr.tesla.com):
Tesla Part Number | Figure |
---|---|
1492139-00-A/B | ![TESLA-CD-24-20-001-Cybertruck-Event-Data-Recorder-Retrieval- |
fig-1](https://manuals.plus/wp-content/uploads/2024/03/TESLA-CD-24-20-001 -Cybertruck-Event-Data-Recorder-Retrieval-fig-1.png)
Table 1 – EDR Data Retrieval Cable Information
Establish a Direct-to-Module Connection
Instructions for direct-to-module EDR data retrieval can be found in the Service Manual. For Further Assistance For technical support, please contact the exclusive Tesla EDR hardware distributor, Crash Data Group: