Item Number: A04085
WARNING (To reduce the risk of fire, electric shock, or personal injury):
-
We suggest installation by a licensed electrician.
-
Please read the instruction carefully and save it as you may need it at a later time.
-
Before you start, NEVER attempt any work without shutting off the electricity until the work is done.
A) Go to the main fuse, or circuit breaker, box in your home. Place the main power switch in the “OFF” position.
B) Place the wall switch in the “OFF” position. -
The mounting surface should be clean, dry, flat, strong enough and 1/4” larger than the canopy on all sides. Any gaps between the mounting surface and canopy exceeding 3/16” should be corrected as required.
-
Make sure that the ceiling or wall can stand the weight of the lamp before installation.
-
Make sure the voltage you are using is 120V. The maximum wattage is 40W per bulb.
-
Keep the lamp away from acidic and alkaline substances in case of damaging the surface of the lamp.
-
When replacing bulbs, you should turn off or unplug the lamp and you must wait until it is cool as bulbs get hot quickly.
-
The safety instructions appearing in this manual are not meant to cover all possible conditions that may occur. It must be understood that common sense, caution, and care must be used with any electrical products.
IMAGE FOR FINISHED PRODUCT
TOOLS REQUIRED (NOT INCLUDED):
Before starting assembly and installation please prepare the needed tools as below picture
PARTS TYPE & QTY INCLUDING:
(C) Single bar (1) | (K) Knob nut (8) |
---|---|
(D) Green ground screw (1) | (L) Upper iron frame (1) |
(E) Canopy (1) | (M) Tube (4) |
(F) Collar ring (1) | (N) Stem (1) |
(G) Collar loop (1) | (O) Sockets assembly (1) |
(H) Quick link (2) | (P) Shorter wire (26) |
(I) Chain (1) | (Q) Longer wire (26) |
(J) Loop (1) | (R) The lower iron frame(1) |
ACCESSORIES & QTY ENCLOSED:
(A) Wire connector (3)
(B) Mounting screw (2)
(K) Knob nut (1) (spare parts)
ASSEMBLY & INSTALLATION INSTRUCTIONS
-
Carefully remove the fixture from the carton and check that all parts and accessories are included as shown in the above illustration.
-
Make pre-installation
Step A1: Attach the upper iron frame (L) and lower iron frame (R) to tubes (M) with knob nuts (K).
Step A2: Screw shorter wires (P) and longer wires (Q) to sockets assembly (O). (Screw the wires in the sequence of a long wire and a shorter wire.)
Step A3: Thread fixture wires through the upper iron frame (L) and loop (J), then screw loop (J) to stem (N) through the upper iron frame (L).
Step B1: By measuring, determine the correct number of links needed for proper hanging height. Using the chain pliers, disconnect and discard the unwanted part.
Step B2: Attach quick link (H) to chain (I) and loop (J) on the top of the upper iron frame (L).
Step B3: Carefully weave fixture wires through the chain (I) in and out of every other link and stop just when you reach the top of the chain (I). Gently pull the wires to ensure the wires are not stressed. -
Turn off power
Before you start the installation, NEVER attempt any work without shutting off the electricity until the work is done.
A) Go to the main fuse, or circuit breaker, box in your home. Place the main power switch in the “OFF” position.
B) Place the wall switch in the “OFF” position. -
Make installation
Step C1: Remove collar ring (F) from collar loop (G). Attach single bar (C) to the outlet box with mounting screws (B). Note: be sure that the side of the single bar marked “GND” must face out.
Step C2: Raise canopy (E) over collar loop (G) and screw collar ring (F) to measure a proper position.
Unscrew collar ring (F) from collar loop (G) and remove canopy (E). Refer to the following note, you would know the proper position where the collar loop (G) should be located.
Note: canopy (E) should be snug against the ceiling and collar loop (G) should be screwed with enough threads (no less than 6 threads) on the pre-assembled threaded nipple for more secure hanging. If not, adjust the collar loop (G) on the single bar assembly (C) by screwing the collar loop (G) in or out of the single bar (C) until the secure length is achieved.
Step C3: Pass chain (I) through collar ring (F) and then through the canopy (E).
Step C4: Open quick link (H), and attach quick link (H) to collar loop (G). Close quick link (H).
Pass the fixture wires through collar loop (G) to the top of the pre-assembled threaded nipple and gently pull them to ensure the wires are not stressed.
Step C5: If needed, shorten the length of the fixture wires. At this point, the remaining wire length measured above the single bar (C) is at least 6″.
Step C6: Make wire connections
Connect wires as below wires connection shown. PLEASE NOTE THAT GROUND WIRE IS BARE COPPER WIRE, NEVER CONNECT OTHER WIRES TO GROUND WIRES.
Connect ground wires according to the below chart
Connect wires according to the below chart
**** -
Check everything is already installed properly, then you could turn on the light. Enjoy!
CLEANING
To clean, wipe the fixture with a soft cloth. Do not use abrasive materials
such as scouring pads or powders, steel wool or abrasive paper.
ORDERING PARTS.
Keep this sheet for future reference in case you need to order replacement
parts. All parts for this fixture can be ordered from the place of purchase.
Be sure to use exact wording from illustrations when ordering parts.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>