Desoutter 6159920530 Bit Tray
Product Information
The Bit Tray (Part no: 6159360800) is a professional tool designed for use with the Desoutter CVI3 range of controllers. It is specifically designed to hold up to 8 different bits and is connected to the eBUS port of the controller. The Bit Tray is intended for professional use only.
Overall Dimensions
Dimensions: 141mm x 219mm x 190mm
Original instructions.
© Copyright 2022, Ets Georges Renault 44818 St Herblain, FR
All rights reserved. Any unauthorized use or copying of the contents or part
thereof is prohibited. This applies in particular to trademarks, model
denominations, part numbers and drawings. Use only authorized parts. Any
damage or malfunction caused by the use of unauthorised parts is not covered
by Warranty or Product Liability.
Statement of Use
The Bit Tray is designed for use with the Desoutter CVI3 range of controllers
and is only to be connected to the eBUS port. No other use is permitted.This
bit tray is designed for up to 8 different bits and is to be connected to the
eBUS port of the Desoutter CVI3 range of controllers.
No other use will be permitted.
For professional use only.
ON RECEIVING THE BIT TRAY
Check the following items are included in the packing box:
- Legend
- 1 Termination plug SubD 9-pt P/N 6159176250
- 2 Bit tray
Optional Accessories
Description | Part Number |
---|---|
eBus cable 1 m | 6159176210 |
eBus cable 3 m | 6159176220 |
eBus cable 5 m | 6159176230 |
eBus cable 15 m | 6159176240 |
OVERALL DIMENSIONS IN MM
Product Usage Instructions
Table Mounting
To secure the Bit Tray on a table, use M6 screws.
Dimensioning (bottom view)
Wall Mounting
To secure the Bit Tray on a wall, use 4 M6 screws.
Dimensioning (rear view)
eBus Cable Routing
It is possible to daisy-chain up to 15 accessories on the eBUS network. Before connecting, select how to pass the cable:
- On the side
- From below
Bit Tray Connection
The Bit Tray has two connections:
- Termination plug SubD 9-pt: Use this plug when the Bit Tray is unique on the eBUS network or when it is the last accessory on thenetwork.
- eBUS cable connection: Connect the eBUS cable to the bottompanel of the controller.
CONTROLLER CONNECTION
- Connect the eBUS cable to the bottom panel of the controller (see below).
- 24V-1A is supplied from the controller to power the bit tray.
- Max current: 110 mA @ 24V DC.
Bit Tray Position
Use the encoding wheel to set the position number of the Bit Tray on the eBUS cable. The position number ranges from 1 to 15 (1 being the first position, F being the last).
Legend
1 Encoding wheel
- Remove the cap from the encoding wheel.
- By using a screwdriver, select the position number of the bit tray on the eBUS cable:(1-9 and A-F), 1 being the first position, F the last (F=15).
- Do not put the accessory in use when the encoding wheel is set to “0”.
- Put the cap back on the wheel.
Bit Setting
Legend
- 1 Bit hole
- 2 Screw
To insert a bit into the Bit Tray:
- Insert the bit into the bit hole.
- Turn the screw clockwise for a heavier bit or counter-clockwisefor a lighter bit.
LABELING
Disassembly
To label the Bit Tray:
- Loosen the screws on the right side of the Bit Tray.
- Remove the label and write the description with a pencil.
- Add some glue and tighten the screws.
Reassembly
Ensure that the seal is correctly mounted.
Add some glue and tighten the screws as shown below.
Bit Tray Configuration
To configure the Bit Tray, you will need to use the CVI CONFIG software. Refer to the CVI CONFIG user manual at http://resource-center. desouttertools.com.
LIST OF SPARE PARTS
Item | P/N | Designation |
---|---|---|
1 | 6159190235 | Kit PCB connector |
2 | 6159183835 | Kit main board |
3 | 6159190745 | Kit LED board |
4 | 6153985075 | Kit bit module |
5 | 6159166095 | Kit flat cable 14-pt |